I want to search for...
Permit #2025080040
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7028-00460-0080 |
| Block: 00460 |
| Subdivision: 7028 - |
| Job Phone: 904-924-5225 |
| Location Address: 15 PORT ROYAL DR |
| Type: SD - SIDING |
| Issue Date: 08/04/2025 |
| NOC: RECORDED |
| Applicant name: LESLIE CONRAD KOEHLER |
| Owner: WHITEHEAD TERRENCE R & CINDY E MCNAIRY H&W |
|
Address 15 PORT ROYAL DRIVE PALM COAST, FL 32164 |
| Lot: 0080 |
| Contracted Stated Job Value: ¤8,000.00 |
| Job Description: SIDING |
| Type: CN |
Contractor
KOEHLER HOMES INC
| Status | Location Address | State License Number | Phone |
| INACTIVE |
5538 COASTAL LANE S JACKSONVILLE, FL 32258 |
CBC056153 (Exp: 08/31/2026) | 904-924-5225 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL - BUILDING MISC | 09/16/2025 | FINAL APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 9/16/2025 12:39:55 PM *** 8/27/2025 - PREVIOUS INSPECTION NOTES 8/27/25: 1). Right front gable between brick columns: Right side has an excessive gap that may allow water to enter behind siding, etc. Cannot verify if original flashing is in tact and if water barrier beneath siding covers the area sufficiently to prevent water infiltration. This are will need to be sealed in the same manner as done on the left side. >>> This deficiency was previously listed as item 3 (shown below) on the Final inspection performed on 8/14/25. Please resolve before rescheduling inspection. 3). Right front gable: trim is too short creating an excessive gap between brick and trim which will allow water to penetrate into wall space. FBCR 609.9 / FBC-R903.2 __________________________________________________________________________________________________________________________ Inspector Notes from Inspection 2320 Water barrier was covered up, met contractor onsite and demoed locations to check water barrier. Call final back in once job is complete and ready for inspection | |||
| FINAL - BUILDING MISC | 08/27/2025 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 8/27/2025 2:09:11 PM *** 8/27/25: 1). Right front gable between brick columns: Right side has an excessive gap that may allow water to enter behind siding, etc. Cannot verify if original flashing is in tact and if water barrier beneath siding covers the area sufficiently to prevent water infiltration. This are will need to be sealed in the same manner as done on the left side. >>> This deficiency was previously listed as item 3 (shown below) on the Final inspection performed on 8/14/25. Please resolve before rescheduling inspection. 3). Right front gable: trim is too short creating an excessive gap between brick and trim which will allow water to penetrate into wall space. FBCR 609.9 / FBC-R903.2 __________________________________________________________________________________________________________________________ Inspector Notes from Inspection 2320 Water barrier was covered up, met contractor onsite and demoed locations to check water barrier. Call final back in once job is complete and ready for inspection | |||
| LATH/BRICK/ WATER BARRIER | 08/26/2025 | APPROVED - AS NOTED | MKRASKI |
| Note: Water barrier was covered up, met contractor onsite and demoed locations to check water barrier. Call final back in once job is complete and ready for inspection | |||
| FINAL - BUILDING MISC | 08/14/2025 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 8/14/2025 2:36:45 PM *** 8/14/25: Partial list due to missed inspection. 1). Water barrier inspection was never completed and is required prior to scheduling the Final Inspection. FBC-[A] 110.1. Coordination with the City Building Department to resolve this will be required. 2). Missing 'kick outs' at the front of the house (3 areas) allowing water to penetrate behind the Hardie siding and potentially into wall space. FBC-R903.2 3). Right front gable: trim is too short creating an excessive gap between brick and trim which will allow water to penetrate into wall space. FBCR 609.9 / FBC-R903.2 4). Back left side (when facing house) trim is too short creating an excessive gap between brick and trim which will allow water to penetrate into wall space. FBC-R903.2 |
Review History
| Department | Status | Date In | Date Out |
| ZON | COMPLETE | 08/04/2025 | 08/04/2025 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 08/01/2025 | 08/04/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| ZON | HOLD | 08/01/2025 | 08/01/2025 |
| Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM The entire body of the home must be one color. Please provide a note on the plans that this is the case. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 08/26/2025 |
| SURCHARGE FS 533.721 | ¤2.00 | 08/04/2025 |
| SURCHARGE - FS 468.631 | ¤2.00 | 08/04/2025 |
| SITE PLAN 15 | ¤15.00 | 08/04/2025 |
| ADJUSTMENT 10% | (¤12.25) | 08/04/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 08/04/2025 |
| INSPECTION - RESIDENTIAL | ¤60.00 | 08/04/2025 |
| PLAN REVIEW - MISC 32.50 | ¤32.50 | 08/04/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤169.25 |