I want to search for...
Permit #2025080419
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7034-00200-0140 |
| Block: 00200 |
| Subdivision: 7034 - |
| Job Phone: 386-283-7851 |
| Location Address: 18 EAGLE CREST PATH |
| Type: DR - DRIVEWAY |
| Issue Date: 09/18/2025 |
| NOC: RECORDED |
| Applicant name: MICHAEL MENENDEZ |
| Owner: REIDER ALAN PAUL & GAYLE DARLENE TRUSTEES |
|
Address PO BOX 354307 PALM COAST, FL 32135 |
| Lot: 0140 |
| Contracted Stated Job Value: ¤28,000.00 |
| Job Description: PAVER DRIVEWAY |
| Type: CN |
Contractor
ROYAL CONSTRUCTION INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
211 S COOPERS HAWK WAY PALM COAST, FL 32164 |
RB29003957 (Exp: 08/31/2027) | 386-283-7851 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROW - FINAL INSPECTION | 10/20/2025 | APPROVED | FSLADISH |
| Note: 10/20/25 Correction completed at thetime of this inspection. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. 10/17/2025 - PREVIOUS INSPECTION NOTES 10/17/25 PLEASE READ PREVIOUS INSPECTION NOTES. YOU HAVE A LOOSE PAVER THAT NEEDS TO BE RESET ON THE RIGHT SIDE OF THE RIGHT SIDE DRIVEWAY AT THE EDGE OF ROAD. I WILL HOLD UP THE FINAL UNTIL THIS IS REPAIRED. PHOTO FOR REFERENCE 10/14/2025 - PREVIOUS INSPECTION NOTES 10/14/25 YOU HAVE A LOOSE PAVER THAT NEEDS TO BE RESET ON THE RIGHT SIDE OF THE RIGHT SIDE DRIVEWAY AT THE EDGE OF ROAD. I WILL HOLD UP THE FINAL UNTIL THIS IS REPAIRED. | |||
| ROW - FINAL INSPECTION | 10/17/2025 | Disapproved -FEE REQUIRED | FSLADISH |
| Note: 10/17/25 PLEASE READ PREVIOUS INSPECTION NOTES. YOU HAVE A LOOSE PAVER THAT NEEDS TO BE RESET ON THE RIGHT SIDE OF THE RIGHT SIDE DRIVEWAY AT THE EDGE OF ROAD. I WILL HOLD UP THE FINAL UNTIL THIS IS REPAIRED. PHOTO FOR REFERENCE 10/14/2025 - PREVIOUS INSPECTION NOTES 10/14/25 YOU HAVE A LOOSE PAVER THAT NEEDS TO BE RESET ON THE RIGHT SIDE OF THE RIGHT SIDE DRIVEWAY AT THE EDGE OF ROAD. I WILL HOLD UP THE FINAL UNTIL THIS IS REPAIRED. | |||
| U -UTILITY RESIDENTIAL FINAL | 10/14/2025 | FINAL APPROVED | BHAINES |
| ROW - FINAL APRON (AFTER POUR) | 10/14/2025 | APPROVED - AS NOTED | FSLADISH |
| Note: 10/14/25 I AM GOING TO APPROVE THIS AFTER POUR AS NOTED THAT YOU HAVE A LOOSE PAVER THAT NEEDS TO BE RESET ON THE RIGHT SIDE OF THE RIGHT SIDE DRIVEWAY AT THE EDGE OF ROAD. I WILL HOLD UP THE FINAL UNTIL THIS IS REPAIRED. | |||
| ROW - FINAL INSPECTION | 10/14/2025 | Disapproved - NO FEE | FSLADISH |
| Note: 10/14/25 YOU HAVE A LOOSE PAVER THAT NEEDS TO BE RESET ON THE RIGHT SIDE OF THE RIGHT SIDE DRIVEWAY AT THE EDGE OF ROAD. I WILL HOLD UP THE FINAL UNTIL THIS IS REPAIRED. | |||
| ROW- PRE-APRON (PRE-POUR) | 09/26/2025 | APPROVED | FSLADISH |
| Note: 9/26/25 YOU ARE APPROVED TO LAY PAVERS AS OF THIS INSPECTION. ______________________________________________________________________________________________________________________ 9/23/2025 - PREVIOUS INSPECTION NOTES 9/23/25 CULVERTPIPES NOW BOTH WITHIN COPC SWALE PLAN DIAGRAM TOLERANCE. AT THE TIME OF THIS INSPECTION YOU ARE PARTIALLY APPROVED TO POUR YOUR DRIVEWAY APRON AND PAVER RESTRAINTS. **** DO NOT LAY ANY PAVERS UNTIL AFTER A SECONDARY SPREAD AND COMPACTION INSPECTION HAS BEEN SCHEDULED AND PASSED**** BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS 9/19/2025 - PREVIOUS INSPECTION NOTES 9/19/25 LEFT SIDE CULVERT PIPE IS (BACKPITCHED) OUT OF TOLERANCE TO THE SWALE PLAN AT THE TIME OF THIS INSPECTION. RIGHT SIDE CULVERT PIPE IS GOOD AT THIS TIME. ROADSIDE SWALE AND CULVERT SET WITHIN 0.10 Section 300.01 C(3) V-17 3) The driveway culvert(s) must be set within the range established by the Swale Plan. The culvert cannot be sloped against the drainage flow, nor shall it be sloped more than 0.10 of a foot in thedirection of the drainage flow | |||
| ROW- PAVER RESTRAINTS | 09/23/2025 | APPROVED | FSLADISH |
| Note: AT THE TIME OF THIS INSPECTION YOU ARE PARTIALLY APPROVED TO POUR YOUR PAVER RESTRAINTS. **** DO NOT LAY ANY PAVERS UNTIL AFTER A SECONDARY SPREAD AND COMPACTION INSPECTION HAS BEEN SCHEDULED AND PASSED**** BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS | |||
| ROW- PRE-APRON (PRE-POUR) | 09/23/2025 | PARTIALLY APPROVED | FSLADISH |
| Note: 9/23/25 CULVERTPIPES NOW BOTH WITHIN COPC SWALE PLAN DIAGRAM TOLERANCE. AT THE TIME OF THIS INSPECTION YOU ARE PARTIALLY APPROVED TO POUR YOUR DRIVEWAY APRON AND PAVER RESTRAINTS. **** DO NOT LAY ANY PAVERS UNTIL AFTER A SECONDARY SPREAD AND COMPACTION INSPECTION HAS BEEN SCHEDULED AND PASSED**** BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS 9/19/2025 - PREVIOUS INSPECTION NOTES 9/19/25 LEFT SIDE CULVERT PIPE IS (BACKPITCHED) OUT OF TOLERANCE TO THE SWALE PLAN AT THE TIME OF THIS INSPECTION. RIGHT SIDE CULVERT PIPE IS GOOD AT THIS TIME. ROADSIDE SWALE AND CULVERT SET WITHIN 0.10 Section 300.01 C(3) V-17 3) The driveway culvert(s) must be set within the range established by the Swale Plan. The culvert cannot be sloped against the drainage flow, nor shall it be sloped more than 0.10 of a foot in thedirection of the drainage flow | |||
| ROW- PRE-APRON (PRE-POUR) | 09/19/2025 | Disapproved -FEE REQUIRED | FSLADISH |
| Note: 9/19/25 LEFT SIDE CULVERT PIPE IS (BACKPITCHED) OUT OF TOLERANCE TO THE SWALE PLAN AT THE TIME OF THIS INSPECTION. RIGHT SIDE CULVERT PIPE IS GOOD AT THIS TIME. ROADSIDE SWALE AND CULVERT SET WITHIN 0.10 Section 300.01 C(3) V-17 3) The driveway culvert(s) must be set within the range established by the Swale Plan. The culvert cannot be sloped against the drainage flow, nor shall it be sloped more than 0.10 of a foot in thedirection of the drainage flow |
Review History
| Department | Status | Date In | Date Out |
| ZON | HOLD | 08/18/2025 | 08/18/2025 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Bring in original ROW agreement for processing | |||
| ENGIN1 | COMPLETE | 08/18/2025 | 08/18/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| UTL | COMPLETE | 08/18/2025 | 08/19/2025 |
| Note: Released By: LARRY FITZGERALD - (386)286-2041 - LFITZGERALD@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 08/18/2025 | 08/18/2025 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 08/15/2025 | 08/15/2025 |
| Note: Marked INFORMATION By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM RENAME FILE NAME TO SITE PLAN.PDF | |||
| ENGIN1 | COMPLETE | 08/12/2025 | 08/12/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| UTL | COMPLETE | 08/12/2025 | 08/12/2025 |
| Note: Released By: LARRY FITZGERALD - (386)286-2041 - LFITZGERALD@PALMCOASTGOV.COM | |||
| ZON | HOLD | 08/12/2025 | 08/12/2025 |
| Note: Held By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM Cannot add paver patio on a driveway permit - must be separate Driveway width is cut off on site plan - rescan and upload for recording purposes the original RIGHT-OF-WAY UTILIZATION AGREEMENT needs to be handed in and corrected at the bottom where agreement is must be the name of the trust | |||
| SWALE | COMPLETE | 08/12/2025 | 08/14/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| RSI REINSPECTION 1 | ¤35.00 | 10/19/2025 |
| SW ENG REINSPECTION 30 | ¤30.00 | 10/12/2025 |
| SW ENG RES REVIEW 200 | ¤200.00 | 09/18/2025 |
| SITE PLAN 15 | ¤15.00 | 09/18/2025 |
| SW ENG INSPECTION 40 | ¤40.00 | 09/18/2025 |
| SW ENG PRE APRON | ¤30.00 | 09/18/2025 |
| ADJUSTMENT 10% | (¤3.00) | 09/18/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 09/18/2025 |
| RECORDING FEE REIMBURSE DOC | ¤44.00 | 09/18/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤421.00 |