I want to search for...

Permit #2025080435

Permit Details

Status: INSPECT

Parcel Id: 07-11-31-7011-00010-1140
Block: 00010
Subdivision: 7011 -
Job Phone: 904-382-8852
Location Address: 130 BELLEAIRE DR
Type: PO - POOL
Issue Date: 08/28/2025
NOC: RECORDED
Applicant name: SCOTT F GRIFFITHS
Owner: DIOSI ANIKO

Address

130 BELLEAIRE DRIVE

PALM COAST, FL 32137

Lot: 1140
Contracted Stated Job Value: ¤79,000.00
Job Description: Pool W/ Screen
Type: CN

Contractor

PINCH A PENNY
Status Location Address State License Number Phone
ACTIVE

7 OLD KINGS ROAD

PALM COAST, FL 32164

CPC1460307 (Exp: 08/31/2026) 904-382-8852

Sub Contractors

JOSEPH DEREK CARTWRIGHT
Status Location Address State License Number Phone Fax
ACTIVE

151 RODEO ROAD

ORMOND BEACH, FL 32174

SCC131150000 (Exp: 08/31/2026) 386-310-7962 (386)615-3713
CHRISTOPHER I HALL
Status Location Address State License Number Phone
ACTIVE

60 COOPER LANE

PALM COAST, FL 32137

EC13008029 (Exp: 08/31/2028) 386-225-1937

Inspection History

Type Request Date Result Inspector
POOL FINAL 02/10/2026 FINAL APPROVED MCONTRYMAN
Note: 2/5/2026 - PREVIOUS INSPECTION NOTES 1.General purpose Receptacles that fall within the required 6ft of the edge of the pool will need to be Removed and or possibly relocated to be in the required 1 GFCI Protected Receptacle within 6ft to 20ft of the pool. Current receptacles are within 4' 10" and is not GFCI protected. NEC 680.22 2. Please tighten side tension cable to spec. per plan.
POOL FINAL 02/05/2026 Disapproved - NO FEE JSTEWART
Note: 1.General purpose Receptacles that fall within the required 6ft of the edge of the pool will need to be Removed and or possibly relocated to be in the required 1 GFCI Protected Receptacle within 6ft to 20ft of the pool. Current receptacles are within 4' 10" and is not GFCI protected. NEC 680.22 2. Please tighten side tension cable to spec. per plan.
U -UTILITY RESIDENTIAL FINAL 01/29/2026 FINAL APPROVED BWRIGHT
ROW- FINAL SURVEY/GRADING CERTIFICATION 01/28/2026 APPROVED TPOLACEK
Note: 1/22/2026 - PREVIOUS INSPECTION NOTES 01-22-26 TPOLACEK** THE APPROVED SITE PLAN HAS FLOW ARROWS INDICATING DRAINAGE WOULD BE DIRECTED TO THE FRONT SWALE. THE PROPERTY HAS TYPE B DRAINAGE AND SPLITS DRAINAGE TO BOTH FRONT AND BACK. YOU MUST UOLOAD A REVISED SITE PLAN SHOWING THE DRAINAGE SPLITTING AS SHOWN ON FINAL SURVEY. YOU WILL NOT NEED TO HAVE A NEW SURVEY SHOT. ONCE YOU GET THE APPROVED REVISED SITE PLAN YOU MAY RELOAD THE SAME SURVEY FOR REVIEW.
ROW FIELD SURVEY /GRADING CERTIFICATION 01/28/2026 APPROVED TPOLACEK
Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW - FINAL INSPECTION 01/28/2026 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW- FINAL SURVEY/GRADING CERTIFICATION 01/22/2026 Disapproved - NO FEE TPOLACEK
Note: 01-22-26 TPOLACEK** THE APPROVED SITE PLAN HAS FLOW ARROWS INDICATING DRAINAGE WOULD BE DIRECTED TO THE FRONT SWALE. THE PROPERTY HAS TYPE B DRAINAGE AND SPLITS DRAINAGE TO BOTH FRONT AND BACK. YOU MUST UOLOAD A REVISED SITE PLAN SHOWING THE DRAINAGE SPLITTING AS SHOWN ON FINAL SURVEY. YOU WILL NOT NEED TO HAVE A NEW SURVEY SHOT. ONCE YOU GET THE APPROVED REVISED SITE PLAN YOU MAY RELOAD THE SAME SURVEY FOR REVIEW.
ELECTRIC AND ALARM 11/14/2025 APPROVED - AS NOTED MKRASKI
Note: 1. Heat pump requires 4 tie downs, check at final
POOL DECK 10/01/2025 APPROVED FWILLIS
STEEL AND GROUND 09/17/2025 APPROVED FWILLIS
SUBGRADE - FIBERGLASS POOL

Review History

Department Status Date In Date Out
BFLOOD CANCEL 01/22/2026 01/26/2026
RSI COMPLETE 01/22/2026 01/27/2026
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 01/22/2026 01/22/2026
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
ZON COMPLETE 08/18/2025 08/18/2025
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
BLD COMPLETE 08/18/2025 08/21/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BFLOOD CANCEL 08/12/2025 08/13/2025
BLD HOLD 08/12/2025 08/15/2025
Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM 1. Please indicate in pool plans which footer will be utilized. 2. Enclosure plans needs to have footer details.
ELEC COMPLETE 08/12/2025 08/18/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 08/12/2025 08/13/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
RSI COMPLETE 08/12/2025 08/12/2025
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON HOLD 08/12/2025 08/13/2025
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Door pad not shown on site plan. Site plan and pool plan must match.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADJUSTMENT 10% (¤25.50) 08/28/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 08/28/2025
INSPECTION- POOL ¤160.00 08/28/2025
PLAN REVIEW - RESIDENTIAL ¤65.00 08/28/2025
SURCHARGE FS 533.721 ¤2.30 08/28/2025
SURCHARGE - FS 468.631 ¤3.44 08/28/2025
SW ENG INSPECTION 40 ¤40.00 08/28/2025
SW ENG - REVIEW 20 ¤20.00 08/28/2025
SITE PLAN 30 ¤30.00 08/28/2025
Fees Total Due: ¤0.00 Total Paid: ¤325.24