I want to search for...
Permit #2025080450
Permit Details
Status: INSPECT
| Parcel Id: 07-11-31-7065-00550-0300 |
| CONDITIONED SPACE: 2877 sqft |
| GARAGE: 969 sqft |
| OPENED PORCH (WITH ROOF) : 454 sqft |
| Total Square Footage: 4300 sqft |
| Block: 00550 |
| Subdivision: - |
| Job Phone: 386-237-5837 |
| Location Address: 2 KARAS TRL |
| Type: DU - DUPLEX |
| Issue Date: 03/14/2026 |
| NOC: RECORDED |
| Applicant name: MARSEL GILMANSHIN |
| Owner: MEZA JUAN J |
|
Address 110 RICKENBAKER DRIVE B PALM COAST, FL 32164 |
| Lot: 0300 |
| Contracted Stated Job Value: ¤300,000.00 |
| Job Description: Duplex |
| Type: CN |
Contractor
GILMANS DEVELOPMENT CORP
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4873 PALM COAST PARKWAY NW #4 PALM COAST, FL 32137 |
CBC1263180 (Exp: 08/31/2026) | 386-237-5837 |
Sub Contractors
MARSEL GILMANSHIN
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4873 PALM COAST PARKWAY NW #4 PALM COAST, FL 32137 |
CBC1263180 (Exp: 08/31/2026) | 386-237-5837 |
FERNANDO MEZA SR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
457 CHELSEA PLACE AVE ORMOND BEACH, FL 32174 |
EC13003906 (Exp: 08/31/2026) | 386-241-5211 |
MICHAEL FRANK MORELLO
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2 HARGROVE GRADE PALM COAST, FL 32164 |
CAC1819466 (Exp: 08/31/2026) | 386-445-5023 | 386-446-4614 |
JUAN CARLOS GONZALEZ
| Status | Location Address | State License Number |
| ACTIVE |
1328 COUNTY ROAD 308 CRESCENT CITY, FL 32112 |
RF11067806 (Exp: 08/31/2027) |
Inspection History
| Type | Request Date | Result | Inspector |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 06/10/2026 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 6/10/2026 10:00:53 AM *** 6/10/26: Incomplete inspection due to incomplete plans and missing information. 1). Plans (in permit box). do not show firewall framing details above CMU wall. FBC [A]107.3.1 2). Plans do not indicate bearing walls. FBC [A]107.3.1 3). Missing address. R319.1 - Address identification. New and existing buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that it is visible from the street or road fronting the property. Address identification characters shall contrast with their background. Each character shall be a minimum of 4 inches (102mm) high with a minimum stroke width of 1/2" (12.7mm). Address Identification shall be maintained. FBCR 319.1 4). No truss layout plan in permit box or on site. FBC [A]107.3.1 6/4/2026 - PREVIOUS INSPECTION NOTES 1. The house is not ready for inspection. *When everything that is associated with this inspection is finished, please call back the inspection. | |||
| WATER METER INSTALLATION REQUEST | 06/04/2026 | APPROVED | ISANDERSON |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 06/04/2026 | Disapproved - NO FEE | HCAMACHO |
| Note: 1. The house is not ready for inspection. *When everything that is associated with this inspection is finished, please call back the inspection. | |||
| TIE BEAM / LINTEL | 05/18/2026 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 5/18/2026 3:04:16 PM *** Approved | |||
| MONOLITHIC SLAB | 05/04/2026 | APPROVED | KSANDOE |
| PLUMBING 1ST ROUGH UNDERGROUND | 04/29/2026 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 4/29/2026 1:31:59 PM *** 4/29/26: MUST BE COMPLETE BY NEXT INSPECTION. 1). Need address posted as required: FBCR 319.1 | |||
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 04/28/2026 | APPROVED | JMUNSON |
| FORMBOARD SURVEY (OFFICE USE ONLY) | 04/20/2026 | APPROVED | RRICKS |
| WILDLIFE CHECK - ENVIRONMENTAL | 08/19/2025 | APPROVED | DRODRIGUEZ |
| PEP TANK INSTALLATION REQUEST | |||
| U-CROSS CONNECTION | |||
| ROW- PRE-APRON (PRE-POUR) | |||
| ROW - FINAL APRON (AFTER POUR) | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | |||
| ROW - FINAL INSPECTION | |||
| U -UTILITY RESIDENTIAL FINAL | |||
| LATH/BRICK/ WATER BARRIER | |||
| GRAVITY SEWER TEST | |||
| SEWER TIE IN | |||
| ELECTRIC - EARLY POWER | |||
| ALL ROUGH | |||
| FIREWALL FRAMING | |||
| FIREWALL DRYWALL NAILING | |||
| FIREWALL FINAL | |||
| WALL SHEATHING | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | |||
| Note: 6/10/2026 - PREVIOUS INSPECTION NOTES 6/10/26: Incomplete inspection due to incomplete plans and missing information. 1). Plans (in permit box). do not show firewall framing details above CMU wall. FBC [A]107.3.1 2). Plans do not indicate bearing walls. FBC [A]107.3.1 3). Missing address. R319.1 - Address identification. New and existing buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that it is visible from the street or road fronting the property. Address identification characters shall contrast with their background. Each character shall be a minimum of 4 inches (102mm) high with a minimum stroke width of 1/2" (12.7mm). Address Identification shall be maintained. FBCR 319.1 4). No truss layout plan in permit box or on site. FBC [A]107.3.1 6/4/2026 - PREVIOUS INSPECTION NOTES 1. The house is not ready for inspection. *When everything that is associated with this inspection is finished, please call back the inspection. | |||
| ROOF VALLEY & METAL | |||
| INSULATION | |||
| BLD - BUILDING FINAL |
Review History
| Department | Status | Date In | Date Out |
| BLD | PENDING | 06/10/2026 | |
| BADMIN | INFORMATION | 04/27/2026 | 04/27/2026 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Fernando cannot sign the notice of commencement. The notarized signature must match the name of the property owner. | |||
| BLD | HOLD | 04/27/2026 | 04/27/2026 |
| Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM Invalid NOC cant complete inspection | |||
| BLD | COMPLETE | 04/22/2026 | 04/27/2026 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 04/20/2026 | 04/20/2026 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 04/20/2026 | 04/20/2026 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 04/15/2026 | 04/15/2026 |
| Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM There is a typo on the back left corner on the formboard survey. Please revise. | |||
| ZON | COMPLETE | 04/15/2026 | 04/15/2026 |
| Note: Released By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 02/26/2026 | 03/04/2026 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 02/26/2026 | 02/27/2026 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 02/18/2026 | 02/24/2026 |
| Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Previous comments not addressed: - There is still a flat spot over 20' in between lot 30 and 29. There is a 23.80 going to a 23.80. - There shall not be proposed elevations along the CL of the road or at the edge of pavement. These are existing conditions and does not change. Again, please feel free to call if there is still confusion. | |||
| SW1 | HOLD | 02/12/2026 | 02/13/2026 |
| Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Previous comments not addessed: The interior swale between lot 29 shall have positive fall every 20'. | |||
| ENGIN1 | COMPLETE | 02/12/2026 | 02/13/2026 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 01/30/2026 | 02/03/2026 |
| Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Repeat Comments: - There shall be positive fall every 20'. There are still proposed elevations trapping water in the front of yard. - There is still a proposed elevation of 22.40' that doesn't agree with surrounding elevations and 1 lower than the edge of pavament at the edge of pavement. - Front property line shall be even with or higher than the edge of pavament. Again, please feel free to call me at 386-986-4726. We can go over what is required and this will mitigate any more delays. | |||
| SW1 | HOLD | 01/20/2026 | 01/26/2026 |
| Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Grading comments: - How are you lowering the edge of pavement elevations by more than 8" in some areas. - There are slopes greater than 4:1 between lot 29 and this lot. - Lot 31 cannot impact this lot pass the 5' easement in the back yard. - This lot shall drain to Karat Path, as proposed the water is being trapped by higher elevations along the Karat path and diverting water to Karas Trail. Please ensure there is consistent positive fall to Karat Path. Please feel free to call me at 386-986-4726 and we can go over the grading plan to ensure there are no more delays. | |||
| SW1 | HOLD | 12/02/2025 | 12/08/2025 |
| Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Grading comments: - Along the back of the lot shall be a minimum of 0.3' from the lot line to the drainage swale. Based on the information provided there is only 0.2'. - Please provide the distance from the side of the home and the common lot line between this lot and lot 29. This will help determine 4:1 slope requirements are met. - 2nd Request - Please provide road center line and edge of pavement elevations on a 20' grid. Please feel free to call or email if there are any questions or concerns. | |||
| SW1 | HOLD | 11/06/2025 | 11/06/2025 |
| Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Grading Plan Comments: - Based on the infromation provided this lot is still negatively impacting both adjacent lots. - The front property line shall be even with or higher than the edge of pavement - Please provde existing centerline elevations and edge of pavement elevations on a 20' grid - There shall be positve fall (0.1' every 20') Please feel free to call 386-986-4726 or email to mitigate any further dealys | |||
| ENGIN1 | COMPLETE | 11/06/2025 | 11/07/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 10/27/2025 | 10/27/2025 |
| Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Additional Comment: - Please attached only one Grading Plan. Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Grading Plan Comments: - Proposed elevations along improved lots shall match existing grade ± 0.1'. - There shall be 0.1' of fall every 20' - Per building codes R401.3 and R404.1.6, the grade shall drop a minimum of 4 inches (0.33') for masonry or block construction and 6 inches (0.5') for wood-frame construction adjacent to the foundation, with an additional 6-inch drop within the first 10 feet away from the home’s foundation. - Please provide more elevations along the left side of the homes. As depicted there are elevations, proposed elevations are 4' off of the lot line resulting in this lot negatively impacting lot 29. Please feel free to call if there are any questions, this will help mitigate any further delays. 386-986-4726 | |||
| SW1 | HOLD | 10/27/2025 | 10/27/2025 |
| Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 10/23/2025 | 10/23/2025 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 10/23/2025 | 10/27/2025 |
| Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Grading Plan Comments: - Proposed elevations along improved lots shall match existing grade ± 0.1'. - There shall be 0.1' of fall every 20' - Per building codes R401.3 and R404.1.6, the grade shall drop a minimum of 4 inches (0.33') for masonry or block construction and 6 inches (0.5') for wood-frame construction adjacent to the foundation, with an additional 6-inch drop within the first 10 feet away from the home’s foundation. - Please provide more elevations along the left side of the homes. As depicted there are elevations, proposed elevations are 4' off of the lot line resulting in this lot negatively impacting lot 29. Please feel free to call if there are any questions, this will help mitigate any further delays. 386-986-4726 | |||
| BLD | COMPLETE | 10/23/2025 | 10/27/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 10/23/2025 | 10/27/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 10/15/2025 | 10/20/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| ZON | HOLD | 10/15/2025 | 10/15/2025 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Please submit a floor plan with the correct placement of the ac | |||
| SW1 | HOLD | 10/15/2025 | 10/20/2025 |
| Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Grading Plan Comments: - Portions of the grading plan is not legible. - Address previous hold comments. Note: Refer to the Grading Plan Example to assist when the grading plan for this lot. Please feel free to call if there are any questions or concerns. 386-986-4726. | |||
| BLD | HOLD | 10/15/2025 | 10/20/2025 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM . Truss plan packet cover sheet or first page needs include the design professional of record (building design engineer or architect) approval stamp indicating acceptance and approval of truss design (Not wet seal) | |||
| SWALE | COMPLETE | 09/12/2025 | 09/12/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 09/08/2025 | 09/09/2025 |
| Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Grading Comments: - Please depict the whether the adjacent lots are improved or vacant. If adjacent lots are improved FFE is needed. - There are slopes greater than 4:1 conflicting the with summary grading comments. - Edge of parliament and CL elevations shall be depicted on a 20' grid as well. - At all locations of proposed elevations, there shall be existing elevations as well. - There is a 1' drop adjacent to the foundation when the foundation plan is calling for a 16" slab. - There is no FFE for the front porch. - There are no proposed or existing elevations along the front property line. Please look at the Example Grading Plans and read through the SW Information Packet to fully understand what is needed. If there are any questions please feel free to call or email me. | |||
| ZON | HOLD | 09/08/2025 | 09/08/2025 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM REPEAT COMMENT: AC pad location on site plan does not match location on landscape plan and floor plan | |||
| MECH | COMPLETE | 09/08/2025 | 09/09/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | HOLD | 09/08/2025 | 09/11/2025 |
| Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM 1. Truss plan packet cover sheet or first page needs include the design professional of record (building design engineer or architect) approval stamp indicating acceptance and approval of truss design (Not wet seal) 2. Product Approval FL# 41886.5 not a door FL# 17676.1 not valid FL# 34321 not valid 3. Roofing worksheet FL# 34321 not valid 2nd Request | |||
| ELEC | COMPLETE | 09/08/2025 | 09/11/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 09/08/2025 | 09/09/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| PLENV | COMPLETE | 08/13/2025 | 08/19/2025 |
| Note: Released By: DYLAN RODRIGUEZ - - DRODRIGUEZ@PALMCOASTGOV.COM Staff conducted a site visit on 08/19/25 and found no Gopher Tortoise or their burrows. Staff suggests placing silt fence as soon as possible to prevent tortoise from moving into the lot. If any gopher tortoises are located in the future further coordination may be necessary. | |||
| BADMIN | COMPLETE | 08/12/2025 | 08/14/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | HOLD | 08/12/2025 | 08/14/2025 |
| Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM 1. Truss plan packet cover sheet or first page needs include the design professional of record (building design engineer or architect) approval stamp indicating acceptance and approval of truss design (Not wet seal) 2. Product Approval FL# 41886.5 not a door FL# 17676.1 not valid FL# 34321 not valid 3. Roofing worksheet FL# 34321 not valid | |||
| CUSVC | COMPLETE | 08/12/2025 | 08/18/2025 |
| Note: Released By: MICHELLE MCPARTLAND - - | |||
| ELEC | HOLD | 08/12/2025 | 08/18/2025 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need correct outlet spacing in Bed 2 and 3 on right side. NC 2020 210.52 2. Need correct outlet spacing in bed 2 left side. NEC 2020 210.52 3. Washer and dryer need to be GFCI protected. NEC 2020 210.8 4. | |||
| ENGIN1 | HOLD | 08/12/2025 | 08/13/2025 |
| Note: Held By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM Benchmark needs to be shown on the grading/drainage plan. | |||
| GAS | CANCEL | 08/12/2025 | 08/13/2025 |
| LOCATE | COMPLETE | 08/12/2025 | 08/14/2025 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | HOLD | 08/12/2025 | 08/13/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM State card is page with preparers signature. Upload this page only for both side of duplex. Use drop down menu State card and file name state card. State Card needs to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2023 | |||
| SW1 | HOLD | 08/12/2025 | 08/13/2025 |
| Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM - Please provide on-site benchmark on grading plan. - Please provide FFEs for adjacent lots, concrete walks, and front porches. - Please provide EP and CL elevations on a 20' grid - There shall positive fall to the conveyance swale behind the house. Please feel free to call or email if there are any questions or concerns. | |||
| ZON | HOLD | 08/12/2025 | 08/13/2025 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM AC pad location on site plan doesn't match landscape plan and plans Color sheet should state the material of the exterior not the paint type House layout would make this have two front setbacks and two rear House doesn't meet the minimum 10' of the left side |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| FC IMPACT FEE EMS | ¤124.00 | 03/14/2026 |
| IMPACT FEE FIRE | ¤869.02 | 03/14/2026 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤436.00 | 03/14/2026 |
| FC IMPACT FEE LIBRARY | ¤536.00 | 03/14/2026 |
| IMPACT FEE PARKS | ¤3,656.02 | 03/14/2026 |
| IMPACT FEE SCHOOL | ¤10,900.00 | 03/14/2026 |
| IMPACT FEE TRANSPORTATION | ¤2,974.00 | 03/14/2026 |
| PEP TANK INSTALL | ¤1,513.48 | 03/14/2026 |
| WASTEWATER MAIN EXTENSION IMPA | ¤4,770.00 | 03/14/2026 |
| SURCHARGE FS 533.721 | ¤18.51 | 03/14/2026 |
| SURCHARGE - FS 468.631 | ¤27.76 | 03/14/2026 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 03/14/2026 |
| SW ENG INSPECTION 80 | ¤80.00 | 03/14/2026 |
| SW ENG PRE APRON | ¤30.00 | 03/14/2026 |
| SW ENG REINSPECTION 30 | ¤30.00 | 03/14/2026 |
| SW ENG - REVIEW 20 | ¤20.00 | 03/14/2026 |
| SW ENG RES REVIEW 200 | ¤200.00 | 03/14/2026 |
| WATER METER W/ TAP | ¤4,653.86 | 03/14/2026 |
| SEWER CREDIT | (¤3,068.41) | 03/14/2026 |
| WASTEWATER PERM INSPECTION | ¤80.00 | 03/14/2026 |
| WASTEWATER PERM REVIEW | ¤100.00 | 03/14/2026 |
| SEWER CAPITAL FACILITY | ¤8,830.00 | 03/14/2026 |
| WATER CAPITAL FACILITY FEE | ¤7,580.98 | 03/14/2026 |
| WATER PERMIT INSPECTION | ¤80.00 | 03/14/2026 |
| WATER MAIN EXTENSION IMPACT | ¤1,834.54 | 03/14/2026 |
| SITE PLAN 30 | ¤30.00 | 03/14/2026 |
| WATER- TURN ON | ¤100.00 | 03/14/2026 |
| ADJUSTMENT 10% | (¤205.62) | 03/14/2026 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 03/14/2026 |
| INSPECTION - RESIDENTIAL | ¤1,578.50 | 03/14/2026 |
| PLAN REVIEW - RESIDENTIAL | ¤447.72 | 03/14/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | |