I want to search for...

Permit #2025080520

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7025-00150-0210
Block: 00150
Subdivision: 7025 -
Job Phone: 856-776-3930
Location Address: 66 PERROTTI LN
Type: DR - DRIVEWAY
Issue Date: 08/22/2025
NOC: RECORDED
Applicant name: NEFTALI DEJESUS III
Owner: HART HEATHER

Address

66 PERROTTI LANE

PALM COAST, FL 32164

Lot: 0210
Contracted Stated Job Value: ¤12,931.25
Job Description: Remove and replace existing driveway and culvert
Type: CN

Contractor

1621 BUILDING AND REMODELING LLC
Status Location Address State License Number Phone
ACTIVE

389 PALM COAST PARKWAY SW UNIT 3-N

PALM COAST, FL 32137

CGC1534626 (Exp: 08/31/2026) 386-597-5984

Inspection History

Type Request Date Result Inspector
ROW - FINAL APRON (AFTER POUR) 10/07/2025 APPROVED - AS NOTED GBERTOLA
Note: 10/7/25= AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. 10/3/2025 - PREVIOUS INSPECTION NOTES THIS INSPECTION IS CANCELED DUE TO GABE OUT OF THE OFFICE TILL 10/7/25
ROW - FINAL INSPECTION 10/07/2025 APPROVED - AS NOTED GBERTOLA
Note: 10/7/25= AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. 10/3/2025 - PREVIOUS INSPECTION NOTES THIS INSPECTION IS CANCELED DUE TO GABE OUT OF THE OFFICE TILL 10/7/25
U -UTILITY RESIDENTIAL FINAL 10/03/2025 FINAL APPROVED BWRIGHT
ROW - FINAL INSPECTION 10/03/2025 CANCELLED BY APPLICANT PFLANAGAN
Note: THIS INSPECTION IS CANCELED DUE TO GABE OUT OF THE OFFICE TILL 10/7/25
ROW - FINAL APRON (AFTER POUR) 10/03/2025 CANCELLED BY APPLICANT PFLANAGAN
Note: THIS INSPECTION IS CANCELED DUE TO GABE OUT OF THE OFFICE TILL 10/7/25
ROW- PRE-APRON (PRE-POUR) 09/15/2025 APPROVED - AS NOTED GBERTOLA
Note: 9/15/25= The builder needs to pump the water out at the end of the miter end before adding the concrete AT THE TIME OF THE INSPECTION, THE CULVERT PIPE IS GOOD AND READY TO POUR. IF IT RAINS, PLEASE BUILD THE DOUBLE THE CULVERT ELEVATIONS TO MAKE SURE IT IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ New inspection due to canceled inspection 9/10/2025 - PREVIOUS INSPECTION NOTES 9/10/25=THE CULVERT PIPE IS SECURE, AND THE INVERT IS WITHIN CITY TOLERANCE. THE APRON AND DRIVEWAY ARE SOFT IN SOME AREAS, TECHNICAL MANUAL SEC 900.04 (A). REMOVE AT LEAST 1 INCH OF DIRT ACROSS THE FRONT OF THE GARAGE ENTRANCE, WITH A MINIMUM OF 4 INCHES. SEE ATTACHED PICTURES. DRAWING# 300 G (10). THE MITER ENDS ARE FILLED WITH WATER. THE PIPE SHOULD BE DUG OUT 6 INCHES DEEP AND 6 INCHES LONG UNDER EACH END OF THE PIPE. Only Gbertola and Robert Martin, Can do this inspection.
ROW- PRE-APRON (PRE-POUR) 09/12/2025 CANCELLED BY APPLICANT WEB
Note: 9/10/2025 - PREVIOUS INSPECTION NOTES 9/10/25=THE CULVERT PIPE IS SECURE, AND THE INVERT IS WITHIN CITY TOLERANCE. THE APRON AND DRIVEWAY ARE SOFT IN SOME AREAS, TECHNICAL MANUAL SEC 900.04 (A). REMOVE AT LEAST 1 INCH OF DIRT ACROSS THE FRONT OF THE GARAGE ENTRANCE, WITH A MINIMUM OF 4 INCHES. SEE ATTACHED PICTURES. DRAWING# 300 G (10). THE MITER ENDS ARE FILLED WITH WATER. THE PIPE SHOULD BE DUG OUT 6 INCHES DEEP AND 6 INCHES LONG UNDER EACH END OF THE PIPE. Only Gbertola and Robert Martin, Can do this inspection.
ROW- PRE-APRON (PRE-POUR) 09/12/2025 CANCELLED BY APPLICANT WEB
Note: New inspection due to canceled inspection 9/10/2025 - PREVIOUS INSPECTION NOTES 9/10/25=THE CULVERT PIPE IS SECURE, AND THE INVERT IS WITHIN CITY TOLERANCE. THE APRON AND DRIVEWAY ARE SOFT IN SOME AREAS, TECHNICAL MANUAL SEC 900.04 (A). REMOVE AT LEAST 1 INCH OF DIRT ACROSS THE FRONT OF THE GARAGE ENTRANCE, WITH A MINIMUM OF 4 INCHES. SEE ATTACHED PICTURES. DRAWING# 300 G (10). THE MITER ENDS ARE FILLED WITH WATER. THE PIPE SHOULD BE DUG OUT 6 INCHES DEEP AND 6 INCHES LONG UNDER EACH END OF THE PIPE. Only Gbertola and Robert Martin, Can do this inspection.
ROW- PRE-APRON (PRE-POUR) 09/10/2025 Disapproved - NO FEE GBERTOLA
Note: 9/10/25=THE CULVERT PIPE IS SECURE, AND THE INVERT IS WITHIN CITY TOLERANCE. THE APRON AND DRIVEWAY ARE SOFT IN SOME AREAS, TECHNICAL MANUAL SEC 900.04 (A). REMOVE AT LEAST 1 INCH OF DIRT ACROSS THE FRONT OF THE GARAGE ENTRANCE, WITH A MINIMUM OF 4 INCHES. SEE ATTACHED PICTURES. DRAWING# 300 G (10). THE MITER ENDS ARE FILLED WITH WATER. THE PIPE SHOULD BE DUG OUT 6 INCHES DEEP AND 6 INCHES LONG UNDER EACH END OF THE PIPE. Only Gbertola and Robert Martin, Can do this inspection.

Review History

Department Status Date In Date Out
ZON COMPLETE 08/21/2025 08/21/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ENGIN1 COMPLETE 08/21/2025 08/21/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
UTL COMPLETE 08/21/2025 08/22/2025
Note: Released By: LARRY FITZGERALD - (386)286-2041 - LFITZGERALD@PALMCOASTGOV.COM
SWALE COMPLETE 08/21/2025 08/25/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
ENGIN1 HOLD 08/13/2025 08/15/2025
Note: Held By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM Site plan does not match your scope of work. On the site plan, include the dimensions and material of the new driveway, as well as the material and diameter of the new culvert. Culverts must me a 15" equivalent (13"x17" eliptical or 15" round) and be HDPE or CMP.
UTL COMPLETE 08/13/2025 08/15/2025
Note: Released By: LARRY FITZGERALD - (386)286-2041 - LFITZGERALD@PALMCOASTGOV.COM
ZON HOLD 08/13/2025 08/14/2025
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Site plan mark up does not match your scope of work. Please provide material being used for driveway

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADJUSTMENT 10% (¤3.00) 08/22/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 08/22/2025
SW ENG INSPECTION 40 ¤40.00 08/22/2025
SW ENG PRE APRON ¤30.00 08/22/2025
SW ENG RES REVIEW 200 ¤200.00 08/22/2025
SITE PLAN 15 ¤15.00 08/22/2025
Fees Total Due: ¤0.00 Total Paid: ¤312.00