I want to search for...
Permit #2025080593
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7035-00310-0240 |
| Block: 00310 |
| Subdivision: 7035 - |
| Job Phone: (386)627-0927 |
| Location Address: 7 BUTTERFIELD DR |
| Type: PO - POOL |
| Issue Date: 09/04/2025 |
| NOC: RECORDED |
| Applicant name: JASON BRET PAVLOW |
| Owner: KORB GERALD K & MARY JANE MORGAN JTWROS |
|
Address 7 BUTTERFIELD DR PALM COAST, FL 32137 |
| Lot: 0240 |
| Contracted Stated Job Value: ¤58,950.00 |
| Job Description: POOL/EXISTING FENCE |
| Type: CN |
Contractor
WATERSIDE POOLS INC
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| ACTIVE |
15 HARGROVE LANE PALM COAST , FL 32137 |
#3K PALM COAST , FL 32137 |
CPC1457358 (Exp: 08/31/2026) | (386)447-3390 | (386)447-3391 |
Sub Contractors
CHRISTOPHER I HALL
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
P. O. Box 2413 Bunnell, FL 32110 |
EC13002161 (Exp: 08/31/2028) | (386) 437-2966 | 386-437-5042 |
Inspection History
| Type | Request Date | Result | Inspector |
| POOL FINAL | 02/13/2026 | FINAL APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 2/13/2026 2:10:00 PM *** | |||
| U -UTILITY RESIDENTIAL FINAL | 02/12/2026 | FINAL APPROVED | BHAINES |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 02/11/2026 | APPROVED - AS NOTED | TPOLACEK |
| Note: 02-11-26 TPOLACEK*** MET ON SITE WITH P, FLANAGAN F, SLADISH AND CAT FROM WATERSIDE POOLS. SURVEY DID NOT CAPTURE ALL THE LADSCAPING AND DRAINAGE PATTERNS OF THE PROPERTY. THE ADJOIING PROPERTY TO THE LEFT HAS AN INSIDE SWALE AS WELL AND THERE WILL NOT BE ANY ADVERSE CONDITIONS DUE TO POOL BUILD. APPROVING AS NOTED THE ROW INSPECTIONS. UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED 1/30/2026 - PREVIOUS INSPECTION NOTES 01-30-26 TPOLACEK** APPROVED SITE PLAN INDICATES DRAINAGE WILL FLOW AROUND LEFT SIDE AND OUT TO FRONT SWALE. FINAL SURVEY INDICATES DRAINAGE WILL NEGATIVELY IMPACT ADJOINING PROPERTY TO THE LEFT. THERE MUST BE A DRAINAGE FEATURE CREATED THAT WILL DIRECT WATER TO THE FRONT AND NOT GO OVER THE PROPERTY LINE. Finished Floor Elevations (FFE):REAR YARD DRAINAGE Section 300.01 D(6) V-17 6) The top of slope of “W” swales along the property lines shall be a minimum of 0.30 of a foot higher than the toe of slope. Section 300.01 D(6) V-17 1/29/2026 - PREVIOUS INSPECTION NOTES 01-29-26 TPOLACEK*** THE DOCUMENT THAT WAS UPLOADED TO THE FINAL SURVEY IS NOT THE FINAL SURVEY DOCUMENT REQUIRED. PLEASE SUBMIT A TOPO SURVEY FOR INSPECTION | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 02/11/2026 | APPROVED | TPOLACEK |
| Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVEDInspector Notes from Inspection 9463 02-11-26 TPOLACEK*** MET ON SITE WITH P, FLANAGAN F, SLADISH AND CAT FROM WATERSIDE POOLS. SURVEY DID NOT CAPTURE ALL THE LADSCAPING AND DRAINAGE PATTERNS OF THE PROPERTY. THE ADJOIING PROPERTY TO THE LEFT HAS AN INSIDE SWALE AS WELL AND THERE WILL NOT BE ANY ADVERSE CONDITIONS DUE TO POOL BUILD. APPROVING AS NOTED THE ROW INSPECTIONS. UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED 1/30/2026 - PREVIOUS INSPECTION NOTES 01-30-26 TPOLACEK** APPROVED SITE PLAN INDICATES DRAINAGE WILL FLOW AROUND LEFT SIDE AND OUT TO FRONT SWALE. FINAL SURVEY INDICATES DRAINAGE WILL NEGATIVELY IMPACT ADJOINING PROPERTY TO THE LEFT. THERE MUST BE A DRAINAGE FEATURE CREATED THAT WILL DIRECT WATER TO THE FRONT AND NOT GO OVER THE PROPERTY LINE. Finished Floor Elevations (FFE):REAR YARD DRAINAGE Section 300.01 D(6) V-17 6) The top of slope of “W” swales along the property lines shall be a minimum of 0.30 of a foot higher than the toe of slope. Section 300.01 D(6) V-17 1/29/2026 - PREVIOUS INSPECTION NOTES 01-29-26 TPOLACEK*** THE DOCUMENT THAT WAS UPLOADED TO THE FINAL SURVEY IS NOT THE FINAL SURVEY DOCUMENT REQUIRED. PLEASE SUBMIT A TOPO SURVEY FOR INSPECTION | |||
| ROW - FINAL INSPECTION | 02/11/2026 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW- PROJECT STATUS | 02/11/2026 | Status Check | TPOLACEK |
| Note: 02-11-26 TPOLACEK*** MET ON SITE WITH P, FLANAGAN F, SLADISH AND CAT FROM WATERSIDE POOLS. SURVEY DID NOT CAPTURE ALL THE LADSCAPING AND DRAINAGE PATTERNS OF THE PROPERTY. THE ADJOIING PROPERTY TO THE LEFT HAS AN INSIDE SWALE AS WELL AND THERE WILL NOT BE ANY ADVERSE CONDITIONS DUE TO POOL BUILD. APPROVING AS NOTED THE ROW INSPECTIONS. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 01/30/2026 | Disapproved - NO FEE | TPOLACEK |
| Note: 01-30-26 TPOLACEK** APPROVED SITE PLAN INDICATES DRAINAGE WILL FLOW AROUND LEFT SIDE AND OUT TO FRONT SWALE. FINAL SURVEY INDICATES DRAINAGE WILL NEGATIVELY IMPACT ADJOINING PROPERTY TO THE LEFT. THERE MUST BE A DRAINAGE FEATURE CREATED THAT WILL DIRECT WATER TO THE FRONT AND NOT GO OVER THE PROPERTY LINE. Finished Floor Elevations (FFE):REAR YARD DRAINAGE Section 300.01 D(6) V-17 6) The top of slope of “W” swales along the property lines shall be a minimum of 0.30 of a foot higher than the toe of slope. Section 300.01 D(6) V-17 1/29/2026 - PREVIOUS INSPECTION NOTES 01-29-26 TPOLACEK*** THE DOCUMENT THAT WAS UPLOADED TO THE FINAL SURVEY IS NOT THE FINAL SURVEY DOCUMENT REQUIRED. PLEASE SUBMIT A TOPO SURVEY FOR INSPECTION | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 01/29/2026 | Disapproved - NO FEE | TPOLACEK |
| Note: 01-29-26 TPOLACEK*** THE DOCUMENT THAT WAS UPLOADED TO THE FINAL SURVEY IS NOT THE FINAL SURVEY DOCUMENT REQUIRED. PLEASE SUBMIT A TOPO SURVEY FOR INSPECTION | |||
| ELECTRIC AND ALARM | 12/01/2025 | APPROVED | MCONTRYMAN |
| POOL DECK | 11/13/2025 | APPROVED | MCONTRYMAN |
| Note: 11/12/2025 - PREVIOUS INSPECTION NOTES Rang doorbell camera, Knocked at door No answer. Gates closed. please reschedule if unable to be home please have a gate in the full propped open position granting access, and ensuring no pets. FBC[A] 110.5 | |||
| POOL DECK | 11/12/2025 | Disapproved - NO FEE | JSTEWART |
| Note: Rang doorbell camera, Knocked at door No answer. Gates closed. please reschedule if unable to be home please have a gate in the full propped open position granting access, and ensuring no pets. FBC[A] 110.5 | |||
| STEEL AND GROUND | 10/28/2025 | APPROVED | FWILLIS |
| Note: 10/27/2025 - PREVIOUS INSPECTION NOTES | |||
| STEEL AND GROUND | 10/27/2025 | CANCELLED BY APPLICANT | FWILLIS |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 08/26/2025 | 08/29/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 08/21/2025 | 08/21/2025 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 08/21/2025 | 08/25/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | HOLD | 08/21/2025 | 08/25/2025 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. If there are no footers then please circle that detail on page 4 of your master file. | |||
| RSI | COMPLETE | 08/21/2025 | 08/21/2025 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| BFLOOD | CANCEL | 08/15/2025 | 08/18/2025 |
| BLD | HOLD | 08/15/2025 | 08/20/2025 |
| Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM 1. Please add fence to the site plan with self closing gates swinging outward and latches at 54 inches. 2. On pool plans, please circle the footer that will be used. | |||
| ELEC | COMPLETE | 08/15/2025 | 08/18/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | HOLD | 08/15/2025 | 08/18/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM TDH shows a heater loss. Provide manufacturers specs on pool heater | |||
| RSI | COMPLETE | 08/15/2025 | 08/15/2025 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | HOLD | 08/15/2025 | 08/15/2025 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM show on the site plan how the pool will be enclosed on the property if there is no screening enclosure |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADJUSTMENT 10% | (¤25.50) | 09/04/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 09/04/2025 |
| INSPECTION- POOL | ¤160.00 | 09/04/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤65.00 | 09/04/2025 |
| SURCHARGE FS 533.721 | ¤2.30 | 09/04/2025 |
| SURCHARGE - FS 468.631 | ¤3.44 | 09/04/2025 |
| SW ENG INSPECTION 40 | ¤40.00 | 09/04/2025 |
| SW ENG - REVIEW 20 | ¤20.00 | 09/04/2025 |
| SITE PLAN 30 | ¤30.00 | 09/04/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤325.24 |