I want to search for...

Permit #2025080862

Permit Details

Status: COED

Parcel Id: 07-11-31-7032-00820-0070
CONDITIONED SPACE: 1851 sqft
GARAGE: 411 sqft
OPENED PORCH (WITH ROOF) : 39 sqft
OPENED PORCH (WITH ROOF) : 74 sqft
Total Square Footage: 2375 sqft
Block: 00820
Subdivision: -
Job Phone: 904-531-5923
Location Address: 2 ROLLS ROYCE CT N
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 09/12/2025
NOC: RECORDED
Applicant name: MATTHEW C BROWN
Owner: BRIGHTLAND HOMES OF FLORIDA LLC

Address

15725 N DALLAS PARKWAY

ADDISON, TX 75001

Address

SUITE 300

ADDISON, TX 75001

Lot: 0070
Contracted Stated Job Value: ¤250,000.00
Job Description: SINGLE FAMILY RESIDENCE REF#2024060591
Type: CN
Original Permit #: 2024060591

Contractor

BRIGHTLAND HOMES OF FLORIDA, LLC
Status Location Address Mailing Address State License Number Phone
ACTIVE

3505 EAST FRONTAGE RD

ADDISON, TX 75001

STE 145

TAMPA, FL 33607

CGC1527097 (Exp: 08/31/2026) 904-531-5923

Sub Contractors

GREGORY WILLIAM FARIS
Status Location Address State License Number Phone
ACTIVE

531 CODISCO WAY

SANFORD, FL 32771

CAC1822274 (Exp: 08/31/2026) 407-333-2665
OLIN MARSHALL CANNON
Status Location Address State License Number Phone
INACTIVE

1794 ROGERO RD #2

JACKSONVILLE, FL 32211

CFC1426140 (Exp: 08/31/2026) 904-343-4344
JAMES M GREENSLADE
Status Location Address State License Number Phone Fax
ACTIVE

311 S BAY ST

BUNNELL, FL 32110

EC13006083 (Exp: 08/31/2026) 386-263-2960 386-263-2980
DUSTIN L ESTEP
Status Location Address State License Number Phone Fax
ACTIVE

2041 N HIAWASSEE RD

APOPKA, FL 32703

CCC1330971 (Exp: 08/31/2026) 407-702-0206 352-988-6629
DUSTIN L ESTEP
Status Location Address State License Number Phone Fax
ACTIVE

2041 N HIAWASSEE RD

APOPKA, FL 32703

CCC1330971 (Exp: 08/31/2026) 407-702-0206 352-988-6629
OLIN MARSHALL CANNON
Status Location Address State License Number Phone
INACTIVE

1794 ROGERO RD #2

JACKSONVILLE, FL 32211

CFC1426140 (Exp: 08/31/2026) 904-343-4344
JAMES M GREENSLADE
Status Location Address State License Number Phone Fax
ACTIVE

311 S BAY ST

BUNNELL, FL 32110

EC13006083 (Exp: 08/31/2026) 386-263-2960 386-263-2980

Inspection History

Type Request Date Result Inspector
ROW - FINAL APRON (AFTER POUR) 02/11/2026 APPROVED FSLADISH
Note: 2/12/26 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. Inspector Notes from Inspection 9465 2/4/26 WHILE YOU HAVE REMOVED THE TREES AND REPAIRED THE AREA ABUTTING THE WATER METER YOU WILL NEED TO LAY SOD TO GRADE AT THE WATER METER REPAIR AREA AND ALSO SOD TO GRADE THE ENTIRE BARE AREA WHERE THE TREES WERE BEFORE ROW FINAL PASSAGE. SOD AT ROAD EDGE IS GOOD AT THE TIME OF THIS INSPECTION. I AM APPROVING THIS INSPECTION AS NOTED TO ALLOW YOU TO MOVE FORWARD WITH INSPECTIONS. PLEASE MAKE REQUIRED CORRECTIONS BEFORE RESUBMITTING FOR ROW FINAL. PHOTO FOR REFERENCE. _________________________________________________________________________________________________________________________ 1/28/2025 - PREVIOUS INSPECTION NOTES 1) ALL SOD ALONG THE EDGE OF ROAD NEEDS TO BE BELOW EDGE OF PAVEMENT SO WATER CAN FLOW INTO SWALE. DRAWING 300.F FINISH GRADE TO BE 2 INCHES BELOW THE EDGE OF THE PAVEMENT BEFORE THE SOD IS LAID 2) BOTH CRAPE MYRTLE ON THE LEFT SIDE OF HOUSE NEED TO REMOVE OUT OF THE DRAINAGE PATTERN. 3) NEED TO REPAIR HOLE BY THE WATER METER.
ROW - STORMWATER FINAL 02/11/2026 APPROVED FSLADISH
Note: 2/12/26 REQUIRED CORRECTIONS COMPLETED AT THE TIME OF THIS INSPECTION. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED ______________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9465 2/4/26 WHILE YOU HAVE REMOVED THE TREES AND REPAIRED THE AREA ABUTTING THE WATER METER YOU WILL NEED TO LAY SOD TO GRADE AT THE WATER METER REPAIR AREA AND ALSO SOD TO GRADE THE ENTIRE BARE AREA WHERE THE TREES WERE BEFORE ROW FINAL PASSAGE. SOD AT ROAD EDGE IS GOOD AT THE TIME OF THIS INSPECTION. I AM APPROVING THIS INSPECTION AS NOTED TO ALLOW YOU TO MOVE FORWARD WITH INSPECTIONS. PLEASE MAKE REQUIRED CORRECTIONS BEFORE RESUBMITTING FOR ROW FINAL. PHOTO FOR REFERENCE. _________________________________________________________________________________________________________________________ 1/28/2025 - PREVIOUS INSPECTION NOTES 1) ALL SOD ALONG THE EDGE OF ROAD NEEDS TO BE BELOW EDGE OF PAVEMENT SO WATER CAN FLOW INTO SWALE. DRAWING 300.F FINISH GRADE TO BE 2 INCHES BELOW THE EDGE OF THE PAVEMENT BEFORE THE SOD IS LAID 2) BOTH CRAPE MYRTLE ON THE LEFT SIDE OF HOUSE NEED TO REMOVE OUT OF THE DRAINAGE PATTERN. 3) NEED TO REPAIR HOLE BY THE WATER METER.
U -UTILITY RESIDENTIAL FINAL 02/11/2026 FINAL APPROVED BHAINES
ROW FIELD SURVEY /GRADING CERTIFICATION 02/04/2026 APPROVED - AS NOTED FSLADISH
Note: 2/4/26 WHILE YOU HAVE REMOVED THE TREES AND REPAIRED THE AREA ABUTTING THE WATER METER YOU WILL NEED TO LAY SOD TO GRADE AT THE WATER METER REPAIR AREA AND ALSO SOD TO GRADE THE ENTIRE BARE AREA WHERE THE TREES WERE BEFORE ROW FINAL PASSAGE. SOD AT ROAD EDGE IS GOOD AT THE TIME OF THIS INSPECTION. I AM APPROVING THIS INSPECTION AS NOTED TO ALLOW YOU TO MOVE FORWARD WITH INSPECTIONS. PLEASE MAKE REQUIRED CORRECTIONS BEFORE RESUBMITTING FOR ROW FINAL. PHOTO FOR REFERENCE. _________________________________________________________________________________________________________________________ 1/28/2025 - PREVIOUS INSPECTION NOTES 1) ALL SOD ALONG THE EDGE OF ROAD NEEDS TO BE BELOW EDGE OF PAVEMENT SO WATER CAN FLOW INTO SWALE. DRAWING 300.F FINISH GRADE TO BE 2 INCHES BELOW THE EDGE OF THE PAVEMENT BEFORE THE SOD IS LAID 2) BOTH CRAPE MYRTLE ON THE LEFT SIDE OF HOUSE NEED TO REMOVE OUT OF THE DRAINAGE PATTERN. 3) NEED TO REPAIR HOLE BY THE WATER METER.
BLD - BUILDING FINAL 01/21/2026 Approval - Private Provider PPROVIDER
Note: 1/19/2026 10:56:21 PM- PREVIOUS INSPECTION NOTES 12/26/2025 11:50:35 AM- PREVIOUS INSPECTION NOTES
BLD - BUILDING FINAL 01/16/2026 Disapproved- Private Provider PPROVIDER
Note: 12/26/2025 11:50:35 AM- PREVIOUS INSPECTION NOTES
U-CROSS CONNECTION 12/26/2025 APPROVED BWRIGHT
BLD - BUILDING FINAL 12/15/2025 Disapproved- Private Provider PPROVIDER
ROW- FINAL SURVEY/GRADING CERTIFICATION 01/28/2025 APPROVED PFLANAGAN
ROW FIELD SURVEY /GRADING CERTIFICATION 01/28/2025 Disapproved - NO FEE PFLANAGAN
Note: 1) ALL SOD ALONG THE EDGE OF ROAD NEEDS TO BE BELOW EDGE OF PAVEMENT SO WATER CAN FLOW INTO SWALE. DRAWING 300.F FINISH GRADE TO BE 2 INCHES BELOW THE EDGE OF THE PAVEMENT BEFORE THE SOD IS LAID 2) BOTH CRAPE MYRTLE ON THE LEFT SIDE OF HOUSE NEED TO REMOVE OUT OF THE DRAINAGE PATTERN. 3) NEED TO REPAIR HOLE BY THE WATER METER.
GRAVITY SEWER TEST 12/27/2024 Approval - Private Provider PPROVIDER
Note: Inspector Notes from Inspection 2095 THIS WAS A VIRTUAL INSPECTION
SEWER TIE IN 12/27/2024 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
ROW- PRE-APRON (PRE-POUR) 12/19/2024 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. 12/17/2024 - PREVIOUS INSPECTION NOTES 12/17/24 TPOLACEK*** POUR AREA IS WASHED OUT AND TOO SOFT. BUILDER MUST REESTABLISH POUR AREA. AT THE TIMEOF THIS INSPECTION THE CULVERT ELEVATION AND ALL FORM BOARDS ARE GOOD. YOU ONLY NEED TO REESTABLISH THE BASE. PLEASE CHECK PRE POUR INSPECTIONS IN THE MORNING AFTER RAIN TO CANCEL IF SITE IS NOT READY.
ROW- PRE-APRON (PRE-POUR) 12/17/2024 Disapproved -FEE REQUIRED TPOLACEK
Note: 12/17/24 TPOLACEK*** POUR AREA IS WASHED OUT AND TOO SOFT. BUILDER MUST REESTABLISH POUR AREA. AT THE TIMEOF THIS INSPECTION THE CULVERT ELEVATION AND ALL FORM BOARDS ARE GOOD. YOU ONLY NEED TO REESTABLISH THE BASE. PLEASE CHECK PRE POUR INSPECTIONS IN THE MORNING AFTER RAIN TO CANCEL IF SITE IS NOT READY.
ELECTRIC - EARLY POWER 11/22/2024 Approval - Private Provider PPROVIDER
LATH/BRICK/ WATER BARRIER 11/12/2024 CANCELLED BY APPLICANT WEB
LATH/BRICK/ WATER BARRIER 11/12/2024 Approval - Private Provider PPROVIDER
INSULATION 10/14/2024 Approval - Private Provider PPROVIDER
WATER METER INSTALLATION REQUEST 10/08/2024 APPROVED CBOWERMASTER
LATH/BRICK/ WATER BARRIER 10/08/2024 Approval - Private Provider PPROVIDER
Note: 10/6/2024 8:40:39 PM- PREVIOUS INSPECTION NOTES
INSULATION 10/07/2024 CANCELLED BY APPLICANT WEB
ALL ROUGH 10/02/2024 Approval - Private Provider PPROVIDER
ELECTRIC-TUG 09/24/2024 Approval - Private Provider PPROVIDER
LATH/BRICK/ WATER BARRIER 09/19/2024 CANCELLED BY APPLICANT PPROVIDER
ROOF VALLEY & METAL 09/18/2024 Approval - Private Provider PPROVIDER
WALL SHEATHING 09/17/2024 Approval - Private Provider PPROVIDER
ROOF SHEATHING / BRACES/TIES/DOWN CELL 09/17/2024 Approval - Private Provider PPROVIDER
FOUND SURVEY APPROVED (OFFICE) 09/16/2024 APPROVED TBAKER
MONOLITHIC SLAB 08/23/2024 Approval - Private Provider PPROVIDER
Note: 8/21/2024 2:15:07 PM- PREVIOUS INSPECTION NOTES
MONOLITHIC SLAB 08/20/2024 CANCELLED BY APPLICANT PPROVIDER
PLUMBING 1ST ROUGH UNDERGROUND 08/16/2024 Approval - Private Provider BBEMBRY
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 08/01/2024 APPROVED JMUNSON

Review History

Department Status Date In Date Out
BADMIN INFORMATION 01/22/2026 01/22/2026
Note: Marked INFORMATION By: JAZMIN ROSARIO - - JROSARIO@PALMCOASTGOV.COM FINAL SUMMARY MISSING INFORMATION
BADMIN INFORMATION 01/22/2025 01/22/2025
Note: Marked INFORMATION By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM could not process as there is an inspection with higher priority
BADMIN INFORMATION 01/22/2025 01/22/2025
Note: Marked INFORMATION By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM could not process as there is an inspection with higher priority
ENGIN1 COMPLETE 09/13/2024 09/16/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 09/13/2024 09/13/2024
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD COMPLETE 07/31/2024 08/01/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
SW1 COMPLETE 06/21/2024 06/24/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM Please lower proposed FFE to be no more than 1.83' above crown of road.
ENGIN1 COMPLETE 06/21/2024 06/24/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 06/21/2024 06/21/2024
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BADMIN COMPLETE 06/13/2024 06/18/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 06/13/2024 06/18/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
CUSVC COMPLETE 06/13/2024 06/14/2024
Note: Released By: CYNTHIA SCHWEERS - - CSCHWEERS@PALMCOASSTGOV.COM
ELEC COMPLETE 06/13/2024 06/17/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 06/13/2024 06/13/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 06/13/2024 06/17/2024
LOCATE COMPLETE 06/13/2024 06/21/2024
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 06/13/2024 06/18/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 HOLD 06/13/2024 06/13/2024
Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM Please lower proposed FFE to be no more than 1.83' above crown of road.
ZON COMPLETE 06/13/2024 06/13/2024
Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM
SWALE COMPLETE 06/13/2024 10/04/2024
Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADJUSTMENT 10% (¤3.00) 09/12/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 09/12/2025
ADMINISTRATIVE - RESID PP ¤225.00 09/12/2025
CONTRACTOR CHANGE ¤20.00 09/12/2025
CONTRACTOR CHANGE ¤20.00 09/12/2025
SURCHARGE FS 533.721 ¤2.52 09/12/2025
SURCHARGE - FS 468.631 ¤3.78 09/12/2025
WASTEWATER PERM INSPECTION ¤80.00 09/12/2025
Fees Total Due: ¤0.00 Total Paid: ¤378.30