Permit #2025081132

Permit Details

Status: INSPECT

Parcel Id: 07-11-31-7035-01400-0120
CONDITIONED SPACE: 333 sqft
OPENED PORCH (WITH ROOF) : 183 sqft
Total Square Footage: 516 sqft
Block: 01400
Subdivision: 7035 -
Job Phone: 856-776-3930
Location Address: 5 BILTWELL PL
Type: BA - BUILDING ADDITION
Issue Date: 09/29/2025
NOC: RECORDED
Applicant name: NEFTALI DEJESUS III
Owner: PENICK LEIGH ANN LIFE ESTATE

Address

5 BILTWELL PLACE

PALM COAST, FL 32137

Lot: 0120
Contracted Stated Job Value: ¤117,000.00
Job Description: ADDITION
Type: CN

Contractor

1621 BUILDING AND REMODELING LLC
Status Location Address State License Number Phone
ACTIVE

389 PALM COAST PARKWAY SW UNIT 3-N

PALM COAST, FL 32137

CGC1534626 (Exp: 08/31/2026) 386-597-5984

Sub Contractors

DANIEL J LUSINSKI
Status Location Address Mailing Address State License Number Phone
ACTIVE

389 PALM COAST PARKWAY SW

PALM COAST, FL 32137

#4

PALM COAST, FL 32137

CCC1330133 (Exp: 08/31/2026) 386-338-7926
DANIEL JOSEPH SCHWARZKOPF
Status Location Address State License Number Phone
ACTIVE

4601 E MOODY BLVD D6

PALM COAST, FL 32164

EC13010351 (Exp: 08/31/2026) 386-313-6211
SCOTT H STILLWELL
Status Location Address State License Number Phone
ACTIVE

4500 US 1 UNIT 206

BUNNELL, FL 32110

CAC1819433 (Exp: 08/31/2026) 386-864-4404
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996

Inspection History

Type Request Date Result Inspector
GRAVITY SEWER TEST 05/21/2026 APPROVED MCONTRYMAN
Note: Inspector Notes from Inspection 2060 PLANS ARE LOCATEDB BY FRONT DOOR
SEWER TIE IN 05/21/2026 APPROVED MCONTRYMAN
Note: Inspector Notes from Inspection 2060 PLANS ARE LOCATEDB BY FRONT DOOR
DRYWALL NAILING 04/23/2026 APPROVED HCAMACHO
Note: 4/20/2026 - PREVIOUS INSPECTION NOTES 4/20/26 1. Shower walls are not completed. Will need to inspect once walls are up
DRYWALL NAILING 04/20/2026 PARTIALLY APPROVED MCONTRYMAN
Note: 4/20/26 1. Shower walls are not completed. Will need to inspect once walls are up
INSULATION 04/16/2026 APPROVED MCONTRYMAN
Note: Inspector Notes from Inspection 2320 Note: Previous Notes from all rough, Spoke with Contractor there have been changes to the original plans, Eliminating the Kitchen sink, and W/D. A Letter was submitted to the City. Inspector Notes from Inspection 2420 1. Plumbing incomplete, Main supply capped off in attic,(No connection to existing) (Air Pressure Test) 2. No water supply lines to Kitchen sink, or W/D. per plan pg. EP1.01 (Plumbing floor plan). 3. Kitchen sink DWV capped inside of CMU wall. pg.EP1.01 (Sanitary floor plan) 4. W/D DWV Unable to locate. per plan pg.EP1.01 (Sanitary floor plan) 5. No 5ft head test on DWV. FBCR P2503.5 Please have work completed prior to Insulation Inspection, and Locations will require to be open and Preassure test. With a 5ft Head test on DWV. .
LATH/BRICK/ WATER BARRIER 03/30/2026 APPROVED - AS NOTED JSTEWART
Note: Note: Previous Notes from all rough, Spoke with Contractor there have been changes to the original plans, Eliminating the Kitchen sink, and W/D. A Letter was submitted to the City. Inspector Notes from Inspection 2420 1. Plumbing incomplete, Main supply capped off in attic,(No connection to existing) (Air Pressure Test) 2. No water supply lines to Kitchen sink, or W/D. per plan pg. EP1.01 (Plumbing floor plan). 3. Kitchen sink DWV capped inside of CMU wall. pg.EP1.01 (Sanitary floor plan) 4. W/D DWV Unable to locate. per plan pg.EP1.01 (Sanitary floor plan) 5. No 5ft head test on DWV. FBCR P2503.5 Please have work completed prior to Insulation Inspection, and Locations will require to be open and Preassure test. With a 5ft Head test on DWV. .
ALL ROUGH 03/26/2026 APPROVED - AS NOTED JSTEWART
Note: 1. Plumbing incomplete, Main supply capped off in attic,(No connection to existing) (Air Pressure Test) 2. No water supply lines to Kitchen sink, or W/D. per plan pg. EP1.01 (Plumbing floor plan). 3. Kitchen sink DWV capped inside of CMU wall. pg.EP1.01 (Sanitary floor plan) 4. W/D DWV Unable to locate. per plan pg.EP1.01 (Sanitary floor plan) 5. No 5ft head test on DWV. FBCR P2503.5 Please have work completed prior to Insulation Inspection, and Locations will require to be open and Preassure test. With a 5ft Head test on DWV.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/17/2026 APPROVED KSANDOE
Note: 2/17/2026 - PREVIOUS INSPECTION NOTES 2/17/26: NO CHANGE FROM PREVIOUS INSPECTION! 1). Porch area framing is not completed. FBC [A]107.4 2). Plans are missing details on overvalley framing anchoring. FBC [A]107.4 3). Revised plans are only accepted. Need to be approved, stamped by the City and be on site for inspection. FBC [A]107.3.1 A full inspection will need to be completed once approved and stamped plans are complete and on site. Revision required for missing information. ____________________________________________________________________________________________________________________ 2/13/2026 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY RSIMS 2/13/2026 2:47:54 PM *** A full inspection will need to be completed once approved and stamped plans are complete and on site. Revision required for missing information. 2/13/26: 1). Porch area framing is not completed. FBC [A]107.4 2). Plans are missing details on overvalley framing anchoring. FBC [A]107.4 3). Revised plans are only accepted. Need to be approved, stamped by the City and be on site for inspection. FBC [A]107.3.1
ROOF VALLEY & METAL 03/17/2026 APPROVED KSANDOE
ROOF SHEATHING / BRACES/TIES/DOWN CELL 02/17/2026 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 2/17/2026 2:54:22 PM *** 2/17/26: NO CHANGE FROM PREVIOUS INSPECTION! 1). Porch area framing is not completed. FBC [A]107.4 2). Plans are missing details on overvalley framing anchoring. FBC [A]107.4 3). Revised plans are only accepted. Need to be approved, stamped by the City and be on site for inspection. FBC [A]107.3.1 A full inspection will need to be completed once approved and stamped plans are complete and on site. Revision required for missing information. ____________________________________________________________________________________________________________________ 2/13/2026 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY RSIMS 2/13/2026 2:47:54 PM *** A full inspection will need to be completed once approved and stamped plans are complete and on site. Revision required for missing information. 2/13/26: 1). Porch area framing is not completed. FBC [A]107.4 2). Plans are missing details on overvalley framing anchoring. FBC [A]107.4 3). Revised plans are only accepted. Need to be approved, stamped by the City and be on site for inspection. FBC [A]107.3.1
ROOF SHEATHING / BRACES/TIES/DOWN CELL 02/13/2026 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 2/13/2026 2:47:54 PM *** A full inspection will need to be completed once approved and stamped plans are complete and on site. Revision required for missing information. 2/13/26: 1). Porch area framing is not completed. FBC [A]107.4 2). Plans are missing details on overvalley framing anchoring. FBC [A]107.4 3). Revised plans are only accepted. Need to be approved, stamped by the City and be on site for inspection. FBC [A]107.3.1
TIE BEAM / LINTEL 01/07/2026 APPROVED JSTEWART
MONOLITHIC SLAB 12/11/2025 APPROVED MCONTRYMAN
Note: 12/3/2025 - PREVIOUS INSPECTION NOTES 1. Depth of base/mono footing per plan is 36" from FF (currently 30"). 2. reinforcment at base footing per plan required 16" OC thru out Base footing. 3. No approved plans onsite. FBC [A]107.3.1 4. Per notes by engineer on plans and mono slab requirement need to have a compaction report (onsite) indicating a 90% compaction fill under slab. 11/14/2025 - PREVIOUS INSPECTION NOTES 11/14/25: Footers and rebar are still not installed as required on plans. 1). Rebar into existing footer needs to be connected to hook rods per plan detail. FBC [A]107.4 2). Missing rebar embed and rebar along with thickened footer for patio area. FBC [A]107.4 3). No size detail for lower main footer. Also, we need to know how the inner #5 rebar shown (at CMU AT CONC POURDOWN FDN) in the thickened edge footer portion of the footer will be secured. Additionally, the plan shows 6mil vapor barrier at the top left detail and 10mil vapor barrier at the footer detail. Please identify which is required. Lastly, the engineer will need to identify if the sub-footer and thickened edge footer will need to be poured seperately to maintain installation requirements. .Revision required. FBC [A]107.4. Please call with questions. 11/13/2025 - PREVIOUS INSPECTION NOTES Missing horizontal reinforcement, hook reinforcement tied wrong location should be tied to the missing reinforcement. if have questions please schedule an appointment with inspector to go over the details on the Plans. 386-986-5407 11/7/2025 - PREVIOUS INSPECTION NOTES Missing footing dowels at corners and openings per plan (Highlighted). Missing reinforcement per plans for CMU wall footing, and porch footing. Please install per the approved plans. 11/5/2025 - PREVIOUS INSPECTION NOTES Footings not installed per plan details. Please install per plan /or/ submit a revision of footing plans showing detail to be used and also need footing plans to indicate locations of footings dowels required by engineered drawing.
MONOLITHIC SLAB 12/03/2025 Disapproved -FEE REQUIRED JSTEWART
Note: 1. Depth of base/mono footing per plan is 36" from FF (currently 30"). 2. reinforcment at base footing per plan required 16" OC thru out Base footing. 3. No approved plans onsite. FBC [A]107.3.1 4. Per notes by engineer on plans and mono slab requirement need to have a compaction report (onsite) indicating a 90% compaction fill under slab. 11/14/2025 - PREVIOUS INSPECTION NOTES 11/14/25: Footers and rebar are still not installed as required on plans. 1). Rebar into existing footer needs to be connected to hook rods per plan detail. FBC [A]107.4 2). Missing rebar embed and rebar along with thickened footer for patio area. FBC [A]107.4 3). No size detail for lower main footer. Also, we need to know how the inner #5 rebar shown (at CMU AT CONC POURDOWN FDN) in the thickened edge footer portion of the footer will be secured. Additionally, the plan shows 6mil vapor barrier at the top left detail and 10mil vapor barrier at the footer detail. Please identify which is required. Lastly, the engineer will need to identify if the sub-footer and thickened edge footer will need to be poured seperately to maintain installation requirements. .Revision required. FBC [A]107.4. Please call with questions. 11/13/2025 - PREVIOUS INSPECTION NOTES Missing horizontal reinforcement, hook reinforcement tied wrong location should be tied to the missing reinforcement. if have questions please schedule an appointment with inspector to go over the details on the Plans. 386-986-5407 11/7/2025 - PREVIOUS INSPECTION NOTES Missing footing dowels at corners and openings per plan (Highlighted). Missing reinforcement per plans for CMU wall footing, and porch footing. Please install per the approved plans. 11/5/2025 - PREVIOUS INSPECTION NOTES Footings not installed per plan details. Please install per plan /or/ submit a revision of footing plans showing detail to be used and also need footing plans to indicate locations of footings dowels required by engineered drawing.
MONOLITHIC SLAB 11/14/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 11/14/2025 10:44:33 AM *** 11/14/25: Footers and rebar are still not installed as required on plans. 1). Rebar into existing footer needs to be connected to hook rods per plan detail. FBC [A]107.4 2). Missing rebar embed and rebar along with thickened footer for patio area. FBC [A]107.4 3). No size detail for lower main footer. Also, we need to know how the inner #5 rebar shown (at CMU AT CONC POURDOWN FDN) in the thickened edge footer portion of the footer will be secured. Additionally, the plan shows 6mil vapor barrier at the top left detail and 10mil vapor barrier at the footer detail. Please identify which is required. Lastly, the engineer will need to identify if the sub-footer and thickened edge footer will need to be poured seperately to maintain installation requirements. .Revision required. FBC [A]107.4. Please call with questions. 11/13/2025 - PREVIOUS INSPECTION NOTES Missing horizontal reinforcement, hook reinforcement tied wrong location should be tied to the missing reinforcement. if have questions please schedule an appointment with inspector to go over the details on the Plans. 386-986-5407 11/7/2025 - PREVIOUS INSPECTION NOTES Missing footing dowels at corners and openings per plan (Highlighted). Missing reinforcement per plans for CMU wall footing, and porch footing. Please install per the approved plans. 11/5/2025 - PREVIOUS INSPECTION NOTES Footings not installed per plan details. Please install per plan /or/ submit a revision of footing plans showing detail to be used and also need footing plans to indicate locations of footings dowels required by engineered drawing.
MONOLITHIC SLAB 11/13/2025 Disapproved - NO FEE JSTEWART
Note: Missing horizontal reinforcement, hook reinforcement tied wrong location should be tied to the missing reinforcement. if have questions please schedule an appointment with inspector to go over the details on the Plans. 386-986-5407 11/7/2025 - PREVIOUS INSPECTION NOTES Missing footing dowels at corners and openings per plan (Highlighted). Missing reinforcement per plans for CMU wall footing, and porch footing. Please install per the approved plans. 11/5/2025 - PREVIOUS INSPECTION NOTES Footings not installed per plan details. Please install per plan /or/ submit a revision of footing plans showing detail to be used and also need footing plans to indicate locations of footings dowels required by engineered drawing.
FOOTER 11/07/2025 CANCELLED BY INSPECTOR JSTEWART
Note: for Base footing prior to mono slab (footing) Per plans.
MONOLITHIC SLAB 11/07/2025 Disapproved -FEE REQUIRED JSTEWART
Note: Missing footing dowels at corners and openings per plan (Highlighted). Missing reinforcement per plans for CMU wall footing, and porch footing. Please install per the approved plans. 11/5/2025 - PREVIOUS INSPECTION NOTES Footings not installed per plan details. Please install per plan /or/ submit a revision of footing plans showing detail to be used and also need footing plans to indicate locations of footings dowels required by engineered drawing.
MONOLITHIC SLAB 11/05/2025 Disapproved - NO FEE JSTEWART
Note: Footings not installed per plan details. Please install per plan /or/ submit a revision of footing plans showing detail to be used and also need footing plans to indicate locations of footings dowels required by engineered drawing.
PLUMBING 1ST ROUGH UNDERGROUND 11/03/2025 APPROVED - AS NOTED MGIBSON
Note: PLANS ARE LOCATEDB BY FRONT DOOR
BLD - BUILDING FINAL
ROW- FINAL SURVEY/GRADING CERTIFICATION
ROW FIELD SURVEY /GRADING CERTIFICATION
ROW - FINAL INSPECTION
U -UTILITY RESIDENTIAL FINAL

Review History

Department Status Date In Date Out
BLD COMPLETE 03/30/2026 04/01/2026
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 03/13/2026 03/16/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD HOLD 03/02/2026 03/06/2026
Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM Per inspectors notes, engineer to provide over valley tie down details to existing house roof. No strapping/tiedowns shown on plans 2ND REQUEST
BADMIN COMPLETE 03/02/2026 03/02/2026
Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM
BADMIN HOLD 02/25/2026 02/25/2026
Note: Held By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM 1. RENAME PLANS TO S1.02.pdf, ...
ELEC COMPLETE 02/18/2026 02/23/2026
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD HOLD 02/18/2026 02/24/2026
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Per inspectors notes, engineer to provide over valley tie down details to existing house roof. No strapping/tiedowns shown on plans
BLD HOLD 02/03/2026 02/05/2026
Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM Please indicate/bubble changes on plans.
RSI COMPLETE 02/03/2026 02/10/2026
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ELEC HOLD 02/03/2026 02/04/2026
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Nothing seems to have changed on the electrical. Highlight or bubble changes.
ZON COMPLETE 02/03/2026 02/03/2026
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
BADMIN INFORMATION 02/02/2026 02/02/2026
Note: Marked INFORMATION By: JAZMIN ROSARIO - - JROSARIO@PALMCOASTGOV.COM Submitted plans are not digitally signed and sealed. Plan pages have to be submitted individually and named according to type of plan
BADMIN INFORMATION 12/12/2025 12/12/2025
Note: Marked INFORMATION By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM Unable to process private provider because 1/2 of inspections have been inspected.
ENGIN1 COMPLETE 12/10/2025 12/12/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
RSI COMPLETE 12/10/2025 12/11/2025
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
BLD COMPLETE 11/24/2025 11/26/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
MECH COMPLETE 09/29/2025 09/29/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 09/29/2025 09/29/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ZON COMPLETE 09/29/2025 09/29/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ZON COMPLETE 09/15/2025 09/15/2025
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Please bring in originals tio the office
MECH HOLD 09/15/2025 09/17/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2023 8Th edition (Second Request)
BLD HOLD 09/15/2025 09/22/2025
Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM 1. Provide complete truss plan submittal packet to include all of the following: A.ok B. ok C. ok D. Complete truss plan packet cover sheet or first page to include the design professional of record (building design engineer or architect) approval stamp indicating acceptance and approval of truss design (Not wet seal)
ELEC COMPLETE 09/15/2025 09/16/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BADMIN INFORMATION 09/15/2025 09/15/2025
Note: Marked INFORMATION By: JAZMIN ROSARIO - - JROSARIO@PALMCOASTGOV.COM DESCRIPTION OF WORK AND LEGAL DESCRIPTION NOT LEGIBLE ON NOC
BLD HOLD 08/27/2025 09/04/2025
Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM 1. Provide complete truss plan submittal packet to include all of the following: A. Complete truss plan packet, signed and sealed by a Florida licensed professional engineer (the truss design engineer) B. Truss layout / placement plan from truss manufacturer C. Truss profile plan sheets for all trusses. D. Complete truss plan packet cover sheet or first page to include the design professional of record (building design engineer or architect) approval stamp indicating acceptance and approval of truss design (Not wet seal)
ELEC HOLD 08/27/2025 09/04/2025
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need switchs and lights by all exterior doors. NEC 2020 210.70
ENGIN1 COMPLETE 08/27/2025 08/28/2025
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
GAS CANCEL 08/27/2025 08/28/2025
MECH HOLD 08/27/2025 08/29/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2023 8Th edition
PLUM COMPLETE 08/27/2025 08/29/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
RSI COMPLETE 08/27/2025 08/28/2025
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON HOLD 08/27/2025 08/28/2025
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Please provide a single family dwelling affidavit signed by all owners on deed and have notarized. once electronic copy is approved we will ask for original. Please provide the dimensions and setbacks of addition on Site plan/Survey
BADMIN INFORMATION 08/27/2025 08/27/2025
Note: Marked INFORMATION By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM NOC is missing description of improvement.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 03/23/2026
REINSPECTION RESIDENTIAL ¤40.00 03/23/2026
REINSPECTION RESIDENTIAL ¤40.00 03/23/2026
REINSPECTION RESIDENTIAL ¤40.00 03/23/2026
REINSPECTION RESIDENTIAL ¤40.00 03/23/2026
SURCHARGE FS 533.721 ¤3.99 09/29/2025
SURCHARGE - FS 468.631 ¤5.98 09/29/2025
SW ENG - INSPECTION 20 ¤20.00 09/29/2025
SW ENG - REVIEW 20 ¤20.00 09/29/2025
SITE PLAN 30 ¤30.00 09/29/2025
ADJUSTMENT 10% (¤44.30) 09/29/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 09/29/2025
INSPECTION - RESIDENTIAL ¤321.75 09/29/2025
PLAN REVIEW - RESIDENTIAL ¤91.26 09/29/2025
Fees Total Due: ¤0.00 Total Paid: ¤671.18