Permit #2025081132
Permit Details
Status: INSPECT
| Parcel Id: 07-11-31-7035-01400-0120 |
| CONDITIONED SPACE: 333 sqft |
| OPENED PORCH (WITH ROOF) : 183 sqft |
| Total Square Footage: 516 sqft |
| Block: 01400 |
| Subdivision: 7035 - |
| Job Phone: 856-776-3930 |
| Location Address: 5 BILTWELL PL |
| Type: BA - BUILDING ADDITION |
| Issue Date: 09/29/2025 |
| NOC: RECORDED |
| Applicant name: NEFTALI DEJESUS III |
| Owner: PENICK LEIGH ANN LIFE ESTATE |
|
Address 5 BILTWELL PLACE PALM COAST, FL 32137 |
| Lot: 0120 |
| Contracted Stated Job Value: ¤117,000.00 |
| Job Description: ADDITION |
| Type: CN |
Contractor
1621 BUILDING AND REMODELING LLC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
389 PALM COAST PARKWAY SW UNIT 3-N PALM COAST, FL 32137 |
CGC1534626 (Exp: 08/31/2026) | 386-597-5984 |
Sub Contractors
DANIEL J LUSINSKI
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
389 PALM COAST PARKWAY SW PALM COAST, FL 32137 |
#4 PALM COAST, FL 32137 |
CCC1330133 (Exp: 08/31/2026) | 386-338-7926 |
DANIEL JOSEPH SCHWARZKOPF
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4601 E MOODY BLVD D6 PALM COAST, FL 32164 |
EC13010351 (Exp: 08/31/2026) | 386-313-6211 |
SCOTT H STILLWELL
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4500 US 1 UNIT 206 BUNNELL, FL 32110 |
CAC1819433 (Exp: 08/31/2026) | 386-864-4404 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
Inspection History
| Type | Request Date | Result | Inspector |
| GRAVITY SEWER TEST | 05/21/2026 | APPROVED | MCONTRYMAN |
| Note: Inspector Notes from Inspection 2060 PLANS ARE LOCATEDB BY FRONT DOOR | |||
| SEWER TIE IN | 05/21/2026 | APPROVED | MCONTRYMAN |
| Note: Inspector Notes from Inspection 2060 PLANS ARE LOCATEDB BY FRONT DOOR | |||
| DRYWALL NAILING | 04/23/2026 | APPROVED | HCAMACHO |
| Note: 4/20/2026 - PREVIOUS INSPECTION NOTES 4/20/26 1. Shower walls are not completed. Will need to inspect once walls are up | |||
| DRYWALL NAILING | 04/20/2026 | PARTIALLY APPROVED | MCONTRYMAN |
| Note: 4/20/26 1. Shower walls are not completed. Will need to inspect once walls are up | |||
| INSULATION | 04/16/2026 | APPROVED | MCONTRYMAN |
| Note: Inspector Notes from Inspection 2320 Note: Previous Notes from all rough, Spoke with Contractor there have been changes to the original plans, Eliminating the Kitchen sink, and W/D. A Letter was submitted to the City. Inspector Notes from Inspection 2420 1. Plumbing incomplete, Main supply capped off in attic,(No connection to existing) (Air Pressure Test) 2. No water supply lines to Kitchen sink, or W/D. per plan pg. EP1.01 (Plumbing floor plan). 3. Kitchen sink DWV capped inside of CMU wall. pg.EP1.01 (Sanitary floor plan) 4. W/D DWV Unable to locate. per plan pg.EP1.01 (Sanitary floor plan) 5. No 5ft head test on DWV. FBCR P2503.5 Please have work completed prior to Insulation Inspection, and Locations will require to be open and Preassure test. With a 5ft Head test on DWV. . | |||
| LATH/BRICK/ WATER BARRIER | 03/30/2026 | APPROVED - AS NOTED | JSTEWART |
| Note: Note: Previous Notes from all rough, Spoke with Contractor there have been changes to the original plans, Eliminating the Kitchen sink, and W/D. A Letter was submitted to the City. Inspector Notes from Inspection 2420 1. Plumbing incomplete, Main supply capped off in attic,(No connection to existing) (Air Pressure Test) 2. No water supply lines to Kitchen sink, or W/D. per plan pg. EP1.01 (Plumbing floor plan). 3. Kitchen sink DWV capped inside of CMU wall. pg.EP1.01 (Sanitary floor plan) 4. W/D DWV Unable to locate. per plan pg.EP1.01 (Sanitary floor plan) 5. No 5ft head test on DWV. FBCR P2503.5 Please have work completed prior to Insulation Inspection, and Locations will require to be open and Preassure test. With a 5ft Head test on DWV. . | |||
| ALL ROUGH | 03/26/2026 | APPROVED - AS NOTED | JSTEWART |
| Note: 1. Plumbing incomplete, Main supply capped off in attic,(No connection to existing) (Air Pressure Test) 2. No water supply lines to Kitchen sink, or W/D. per plan pg. EP1.01 (Plumbing floor plan). 3. Kitchen sink DWV capped inside of CMU wall. pg.EP1.01 (Sanitary floor plan) 4. W/D DWV Unable to locate. per plan pg.EP1.01 (Sanitary floor plan) 5. No 5ft head test on DWV. FBCR P2503.5 Please have work completed prior to Insulation Inspection, and Locations will require to be open and Preassure test. With a 5ft Head test on DWV. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/17/2026 | APPROVED | KSANDOE |
| Note: 2/17/2026 - PREVIOUS INSPECTION NOTES 2/17/26: NO CHANGE FROM PREVIOUS INSPECTION! 1). Porch area framing is not completed. FBC [A]107.4 2). Plans are missing details on overvalley framing anchoring. FBC [A]107.4 3). Revised plans are only accepted. Need to be approved, stamped by the City and be on site for inspection. FBC [A]107.3.1 A full inspection will need to be completed once approved and stamped plans are complete and on site. Revision required for missing information. ____________________________________________________________________________________________________________________ 2/13/2026 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY RSIMS 2/13/2026 2:47:54 PM *** A full inspection will need to be completed once approved and stamped plans are complete and on site. Revision required for missing information. 2/13/26: 1). Porch area framing is not completed. FBC [A]107.4 2). Plans are missing details on overvalley framing anchoring. FBC [A]107.4 3). Revised plans are only accepted. Need to be approved, stamped by the City and be on site for inspection. FBC [A]107.3.1 | |||
| ROOF VALLEY & METAL | 03/17/2026 | APPROVED | KSANDOE |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/17/2026 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 2/17/2026 2:54:22 PM *** 2/17/26: NO CHANGE FROM PREVIOUS INSPECTION! 1). Porch area framing is not completed. FBC [A]107.4 2). Plans are missing details on overvalley framing anchoring. FBC [A]107.4 3). Revised plans are only accepted. Need to be approved, stamped by the City and be on site for inspection. FBC [A]107.3.1 A full inspection will need to be completed once approved and stamped plans are complete and on site. Revision required for missing information. ____________________________________________________________________________________________________________________ 2/13/2026 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY RSIMS 2/13/2026 2:47:54 PM *** A full inspection will need to be completed once approved and stamped plans are complete and on site. Revision required for missing information. 2/13/26: 1). Porch area framing is not completed. FBC [A]107.4 2). Plans are missing details on overvalley framing anchoring. FBC [A]107.4 3). Revised plans are only accepted. Need to be approved, stamped by the City and be on site for inspection. FBC [A]107.3.1 | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/13/2026 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 2/13/2026 2:47:54 PM *** A full inspection will need to be completed once approved and stamped plans are complete and on site. Revision required for missing information. 2/13/26: 1). Porch area framing is not completed. FBC [A]107.4 2). Plans are missing details on overvalley framing anchoring. FBC [A]107.4 3). Revised plans are only accepted. Need to be approved, stamped by the City and be on site for inspection. FBC [A]107.3.1 | |||
| TIE BEAM / LINTEL | 01/07/2026 | APPROVED | JSTEWART |
| MONOLITHIC SLAB | 12/11/2025 | APPROVED | MCONTRYMAN |
| Note: 12/3/2025 - PREVIOUS INSPECTION NOTES 1. Depth of base/mono footing per plan is 36" from FF (currently 30"). 2. reinforcment at base footing per plan required 16" OC thru out Base footing. 3. No approved plans onsite. FBC [A]107.3.1 4. Per notes by engineer on plans and mono slab requirement need to have a compaction report (onsite) indicating a 90% compaction fill under slab. 11/14/2025 - PREVIOUS INSPECTION NOTES 11/14/25: Footers and rebar are still not installed as required on plans. 1). Rebar into existing footer needs to be connected to hook rods per plan detail. FBC [A]107.4 2). Missing rebar embed and rebar along with thickened footer for patio area. FBC [A]107.4 3). No size detail for lower main footer. Also, we need to know how the inner #5 rebar shown (at CMU AT CONC POURDOWN FDN) in the thickened edge footer portion of the footer will be secured. Additionally, the plan shows 6mil vapor barrier at the top left detail and 10mil vapor barrier at the footer detail. Please identify which is required. Lastly, the engineer will need to identify if the sub-footer and thickened edge footer will need to be poured seperately to maintain installation requirements. .Revision required. FBC [A]107.4. Please call with questions. 11/13/2025 - PREVIOUS INSPECTION NOTES Missing horizontal reinforcement, hook reinforcement tied wrong location should be tied to the missing reinforcement. if have questions please schedule an appointment with inspector to go over the details on the Plans. 386-986-5407 11/7/2025 - PREVIOUS INSPECTION NOTES Missing footing dowels at corners and openings per plan (Highlighted). Missing reinforcement per plans for CMU wall footing, and porch footing. Please install per the approved plans. 11/5/2025 - PREVIOUS INSPECTION NOTES Footings not installed per plan details. Please install per plan /or/ submit a revision of footing plans showing detail to be used and also need footing plans to indicate locations of footings dowels required by engineered drawing. | |||
| MONOLITHIC SLAB | 12/03/2025 | Disapproved -FEE REQUIRED | JSTEWART |
| Note: 1. Depth of base/mono footing per plan is 36" from FF (currently 30"). 2. reinforcment at base footing per plan required 16" OC thru out Base footing. 3. No approved plans onsite. FBC [A]107.3.1 4. Per notes by engineer on plans and mono slab requirement need to have a compaction report (onsite) indicating a 90% compaction fill under slab. 11/14/2025 - PREVIOUS INSPECTION NOTES 11/14/25: Footers and rebar are still not installed as required on plans. 1). Rebar into existing footer needs to be connected to hook rods per plan detail. FBC [A]107.4 2). Missing rebar embed and rebar along with thickened footer for patio area. FBC [A]107.4 3). No size detail for lower main footer. Also, we need to know how the inner #5 rebar shown (at CMU AT CONC POURDOWN FDN) in the thickened edge footer portion of the footer will be secured. Additionally, the plan shows 6mil vapor barrier at the top left detail and 10mil vapor barrier at the footer detail. Please identify which is required. Lastly, the engineer will need to identify if the sub-footer and thickened edge footer will need to be poured seperately to maintain installation requirements. .Revision required. FBC [A]107.4. Please call with questions. 11/13/2025 - PREVIOUS INSPECTION NOTES Missing horizontal reinforcement, hook reinforcement tied wrong location should be tied to the missing reinforcement. if have questions please schedule an appointment with inspector to go over the details on the Plans. 386-986-5407 11/7/2025 - PREVIOUS INSPECTION NOTES Missing footing dowels at corners and openings per plan (Highlighted). Missing reinforcement per plans for CMU wall footing, and porch footing. Please install per the approved plans. 11/5/2025 - PREVIOUS INSPECTION NOTES Footings not installed per plan details. Please install per plan /or/ submit a revision of footing plans showing detail to be used and also need footing plans to indicate locations of footings dowels required by engineered drawing. | |||
| MONOLITHIC SLAB | 11/14/2025 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 11/14/2025 10:44:33 AM *** 11/14/25: Footers and rebar are still not installed as required on plans. 1). Rebar into existing footer needs to be connected to hook rods per plan detail. FBC [A]107.4 2). Missing rebar embed and rebar along with thickened footer for patio area. FBC [A]107.4 3). No size detail for lower main footer. Also, we need to know how the inner #5 rebar shown (at CMU AT CONC POURDOWN FDN) in the thickened edge footer portion of the footer will be secured. Additionally, the plan shows 6mil vapor barrier at the top left detail and 10mil vapor barrier at the footer detail. Please identify which is required. Lastly, the engineer will need to identify if the sub-footer and thickened edge footer will need to be poured seperately to maintain installation requirements. .Revision required. FBC [A]107.4. Please call with questions. 11/13/2025 - PREVIOUS INSPECTION NOTES Missing horizontal reinforcement, hook reinforcement tied wrong location should be tied to the missing reinforcement. if have questions please schedule an appointment with inspector to go over the details on the Plans. 386-986-5407 11/7/2025 - PREVIOUS INSPECTION NOTES Missing footing dowels at corners and openings per plan (Highlighted). Missing reinforcement per plans for CMU wall footing, and porch footing. Please install per the approved plans. 11/5/2025 - PREVIOUS INSPECTION NOTES Footings not installed per plan details. Please install per plan /or/ submit a revision of footing plans showing detail to be used and also need footing plans to indicate locations of footings dowels required by engineered drawing. | |||
| MONOLITHIC SLAB | 11/13/2025 | Disapproved - NO FEE | JSTEWART |
| Note: Missing horizontal reinforcement, hook reinforcement tied wrong location should be tied to the missing reinforcement. if have questions please schedule an appointment with inspector to go over the details on the Plans. 386-986-5407 11/7/2025 - PREVIOUS INSPECTION NOTES Missing footing dowels at corners and openings per plan (Highlighted). Missing reinforcement per plans for CMU wall footing, and porch footing. Please install per the approved plans. 11/5/2025 - PREVIOUS INSPECTION NOTES Footings not installed per plan details. Please install per plan /or/ submit a revision of footing plans showing detail to be used and also need footing plans to indicate locations of footings dowels required by engineered drawing. | |||
| FOOTER | 11/07/2025 | CANCELLED BY INSPECTOR | JSTEWART |
| Note: for Base footing prior to mono slab (footing) Per plans. | |||
| MONOLITHIC SLAB | 11/07/2025 | Disapproved -FEE REQUIRED | JSTEWART |
| Note: Missing footing dowels at corners and openings per plan (Highlighted). Missing reinforcement per plans for CMU wall footing, and porch footing. Please install per the approved plans. 11/5/2025 - PREVIOUS INSPECTION NOTES Footings not installed per plan details. Please install per plan /or/ submit a revision of footing plans showing detail to be used and also need footing plans to indicate locations of footings dowels required by engineered drawing. | |||
| MONOLITHIC SLAB | 11/05/2025 | Disapproved - NO FEE | JSTEWART |
| Note: Footings not installed per plan details. Please install per plan /or/ submit a revision of footing plans showing detail to be used and also need footing plans to indicate locations of footings dowels required by engineered drawing. | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 11/03/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: PLANS ARE LOCATEDB BY FRONT DOOR | |||
| BLD - BUILDING FINAL | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | |||
| ROW - FINAL INSPECTION | |||
| U -UTILITY RESIDENTIAL FINAL |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 03/30/2026 | 04/01/2026 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 03/13/2026 | 03/16/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | HOLD | 03/02/2026 | 03/06/2026 |
| Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM Per inspectors notes, engineer to provide over valley tie down details to existing house roof. No strapping/tiedowns shown on plans 2ND REQUEST | |||
| BADMIN | COMPLETE | 03/02/2026 | 03/02/2026 |
| Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM | |||
| BADMIN | HOLD | 02/25/2026 | 02/25/2026 |
| Note: Held By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM 1. RENAME PLANS TO S1.02.pdf, ... | |||
| ELEC | COMPLETE | 02/18/2026 | 02/23/2026 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | HOLD | 02/18/2026 | 02/24/2026 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Per inspectors notes, engineer to provide over valley tie down details to existing house roof. No strapping/tiedowns shown on plans | |||
| BLD | HOLD | 02/03/2026 | 02/05/2026 |
| Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM Please indicate/bubble changes on plans. | |||
| RSI | COMPLETE | 02/03/2026 | 02/10/2026 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 02/03/2026 | 02/04/2026 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Nothing seems to have changed on the electrical. Highlight or bubble changes. | |||
| ZON | COMPLETE | 02/03/2026 | 02/03/2026 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 02/02/2026 | 02/02/2026 |
| Note: Marked INFORMATION By: JAZMIN ROSARIO - - JROSARIO@PALMCOASTGOV.COM Submitted plans are not digitally signed and sealed. Plan pages have to be submitted individually and named according to type of plan | |||
| BADMIN | INFORMATION | 12/12/2025 | 12/12/2025 |
| Note: Marked INFORMATION By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM Unable to process private provider because 1/2 of inspections have been inspected. | |||
| ENGIN1 | COMPLETE | 12/10/2025 | 12/12/2025 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| RSI | COMPLETE | 12/10/2025 | 12/11/2025 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 11/24/2025 | 11/26/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 09/29/2025 | 09/29/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 09/29/2025 | 09/29/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 09/29/2025 | 09/29/2025 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 09/15/2025 | 09/15/2025 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Please bring in originals tio the office | |||
| MECH | HOLD | 09/15/2025 | 09/17/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2023 8Th edition (Second Request) | |||
| BLD | HOLD | 09/15/2025 | 09/22/2025 |
| Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM 1. Provide complete truss plan submittal packet to include all of the following: A.ok B. ok C. ok D. Complete truss plan packet cover sheet or first page to include the design professional of record (building design engineer or architect) approval stamp indicating acceptance and approval of truss design (Not wet seal) | |||
| ELEC | COMPLETE | 09/15/2025 | 09/16/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 09/15/2025 | 09/15/2025 |
| Note: Marked INFORMATION By: JAZMIN ROSARIO - - JROSARIO@PALMCOASTGOV.COM DESCRIPTION OF WORK AND LEGAL DESCRIPTION NOT LEGIBLE ON NOC | |||
| BLD | HOLD | 08/27/2025 | 09/04/2025 |
| Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM 1. Provide complete truss plan submittal packet to include all of the following: A. Complete truss plan packet, signed and sealed by a Florida licensed professional engineer (the truss design engineer) B. Truss layout / placement plan from truss manufacturer C. Truss profile plan sheets for all trusses. D. Complete truss plan packet cover sheet or first page to include the design professional of record (building design engineer or architect) approval stamp indicating acceptance and approval of truss design (Not wet seal) | |||
| ELEC | HOLD | 08/27/2025 | 09/04/2025 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need switchs and lights by all exterior doors. NEC 2020 210.70 | |||
| ENGIN1 | COMPLETE | 08/27/2025 | 08/28/2025 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 08/27/2025 | 08/28/2025 |
| MECH | HOLD | 08/27/2025 | 08/29/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2023 8Th edition | |||
| PLUM | COMPLETE | 08/27/2025 | 08/29/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| RSI | COMPLETE | 08/27/2025 | 08/28/2025 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | HOLD | 08/27/2025 | 08/28/2025 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Please provide a single family dwelling affidavit signed by all owners on deed and have notarized. once electronic copy is approved we will ask for original. Please provide the dimensions and setbacks of addition on Site plan/Survey | |||
| BADMIN | INFORMATION | 08/27/2025 | 08/27/2025 |
| Note: Marked INFORMATION By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM NOC is missing description of improvement. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| PLAN REVIEW - REVISION | ¤32.50 | 03/23/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 03/23/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 03/23/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 03/23/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 03/23/2026 |
| SURCHARGE FS 533.721 | ¤3.99 | 09/29/2025 |
| SURCHARGE - FS 468.631 | ¤5.98 | 09/29/2025 |
| SW ENG - INSPECTION 20 | ¤20.00 | 09/29/2025 |
| SW ENG - REVIEW 20 | ¤20.00 | 09/29/2025 |
| SITE PLAN 30 | ¤30.00 | 09/29/2025 |
| ADJUSTMENT 10% | (¤44.30) | 09/29/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 09/29/2025 |
| INSPECTION - RESIDENTIAL | ¤321.75 | 09/29/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤91.26 | 09/29/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤671.18 |