Permit #2025081201
Permit Details
Status: INSPECT
| Parcel Id: 20-12-31-1922-00000-1110 |
| CONDITIONED SPACE: 2078 sqft |
| GARAGE: 479 sqft |
| OPENED PORCH (WITH ROOF) : 159 sqft |
| Total Square Footage: 2716 sqft |
| Subdivision: 2343 - ENCLAVE AT SEMINOLE PALMS |
| Job Phone: 904-541-2326 |
| Location Address: 197 ENCLAVE AVE |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 10/03/2025 |
| NOC: RECORDED |
| Applicant name: KENNETH LLOYD SMITH |
| Owner: RICHMOND AMERICAN HOMES OF FLORIDA LP |
|
Address 10255 FORTUNE PARKWAY SUITE 150 JACKSONVILLE, FL 32256 |
| Lot: 111 |
| Contracted Stated Job Value: ¤250,000.00 |
| Job Description: Single Family Residence |
| Type: CN |
Contractor
RICHMOND AMERICAN HOMES OF FLORIDA LP
| Status | Location Address | State License Number | Phone |
| ACTIVE |
10255 FORTUNE PARKWAY, STE 150 JACKSONVILLE, FL 32256 |
CGC1519936 (Exp: 08/31/2026) | 904-541-2326 |
Sub Contractors
BRETT CHRISTIAN GIBSON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
250 SEGOVIA RD ST AUGUSTINE, FL 32086 |
CAC1818423 (Exp: 08/31/2026) | 904-229-8131 |
JAMES E LINTON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
200 COLLEGE DR ORANGE PARK, FL 32065 |
EC0001152 (Exp: 08/31/2026) | 904-272-0272 |
PAUL ERIC FORSTER
| Status | Location Address | State License Number | Phone |
| ACTIVE |
6114 GOODMAN RD JACKSONVILLE, FL 32244 |
CFC1429261 (Exp: 08/31/2026) | 904-647-1820 |
JAMES T STERLING
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
23 PANTHER LANE PONTE VEDRA, FL 32081 |
SUITE 7 PONTE VEDRA, FL 32081 |
CCC1328645 (Exp: 08/31/2026) | 904-908-4996 |
Inspection History
| Type | Request Date | Result | Inspector |
| PLUMBING 1ST ROUGH UNDERGROUND | 06/11/2026 | Approval - Private Provider | PPROVIDER |
| Note: 6/8/2026 - PREVIOUS INSPECTION NOTES 6/8/26: Inspection not scheduled or performed prior to concrete for Monolithic Slab being poured in place upon arrival. | |||
| MONOLITHIC SLAB | 06/11/2026 | Approval - Private Provider | PPROVIDER |
| Note: 6/8/2026 - PREVIOUS INSPECTION NOTES 6/8/26: Inspection not scheduled or performed prior to concrete for Monolithic Slab being poured in place upon arrival. | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 06/08/2026 | Approval - Private Provider | PPROVIDER |
| PLUMBING 1ST ROUGH UNDERGROUND | 06/08/2026 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 6/8/2026 3:31:12 PM *** 6/8/26: Inspection not scheduled or performed prior to concrete for Monolithic Slab being poured in place upon arrival. | |||
| MONOLITHIC SLAB | 06/08/2026 | Approval - Private Provider | PPROVIDER |
| MONOLITHIC SLAB | 06/08/2026 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 6/8/2026 3:30:40 PM *** 6/8/26: Inspection not scheduled or performed prior to concrete for Monolithic Slab being poured in place upon arrival. | |||
| FORMBOARD SURVEY (OFFICE USE ONLY) | 06/03/2026 | APPROVED | RRICKS |
| WATER METER INSTALLATION REQUEST | 05/15/2026 | APPROVED | ISANDERSON |
| U-CROSS CONNECTION | |||
| ROW- PRE-APRON (PRE-POUR) | |||
| ROW - FINAL APRON (AFTER POUR) | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | |||
| ROW - STORMWATER FINAL | |||
| U -UTILITY RESIDENTIAL FINAL | |||
| GRAVITY SEWER TEST | |||
| SEWER TIE IN | |||
| ELECTRIC - EARLY POWER | |||
| LATH/BRICK/ WATER BARRIER | |||
| ALL ROUGH | |||
| WALL SHEATHING | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | |||
| ROOF VALLEY & METAL | |||
| INSULATION | |||
| BLD - BUILDING FINAL |
Review History
| Department | Status | Date In | Date Out |
| BADMIN | INFORMATION | 06/09/2026 | 06/09/2026 |
| Note: Marked INFORMATION By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM INSURANCE EXPIRED | |||
| SW1 | COMPLETE | 06/03/2026 | 06/03/2026 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 06/03/2026 | 06/03/2026 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 10/02/2025 | 10/03/2025 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 09/23/2025 | 09/29/2025 |
| Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Grading Comments: Plans must be signed and sealed. | |||
| MECH | COMPLETE | 09/23/2025 | 09/24/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 08/29/2025 | 09/04/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 08/29/2025 | 09/04/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 08/29/2025 | 09/09/2025 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 08/29/2025 | 09/04/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 08/29/2025 | 09/02/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 08/29/2025 | 09/02/2025 |
| LOCATE | COMPLETE | 08/29/2025 | 09/03/2025 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | HOLD | 08/29/2025 | 09/03/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Design location on Energy calcs and heatload need to be Daytona Beach 2. Duct layout needs to be signed by the AC contractor per 107.1 FBC Residential 2023 8th Edition 3. Plans show walls at 2x4 with R13. Energy calcs say R19. Revise to match 4. Direction house faces on Heatload does not match the site plan. Revise to match per R403.7 FBC Energy Conservation 2023 8Th Edition 5. Energy calcs need to have street address | |||
| SW1 | HOLD | 08/29/2025 | 09/02/2025 |
| Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Grading Comments As of July 1st the following corrections are needed: COPC Technical Manual Section - 200.01A.1.b.(11) - The Finished Floor Elevation (FFE) of the proposed home’s living space, attached and / or detached garages, attached and / or detached patios, lanais, porches, exterior door landings, sidewalks and similar shall be shown. Unattached pads solely for the purpose of supporting AC, LPG and pool equipment are exempt. - All attached garages, patios, lanais, porches, exterior door landings, sidewalks and similar shall show an FFE of not less than 0.33 tenths of a foot (4 inches) lower than the FFE of the home’s living space. Exception: Access ramps may rise to the FFE of the interior living space for the width of the ramp only. - All attached patios, lanais, porches, exterior door landings, sidewalks and similar and those located within 10 feet of the proposed home shall show a minimum slope perpendicular to the foundation of not less than 2%. Attached and detached garages shall show a positive slope to facilitate drainage towards the vehicle entrance. COPC Technical Manual Section - 200.02.A.1.c. (2) The elevations on all adjacent properties at a minimum of 20-foot intervals on a 10-foot offset outside the property lines. (3) The proposed and existing elevations at 20-foot intervals along all property lines. There must be sufficient elevation shots to indicate the proposed drainage pattern. (4) Elevations at the lot corners, at foundation corners, along all sides of the proposed building, and 10 feet off the proposed building are required in addition to the 20-foot grid. (5) The road centerline (RCL) and edge of pavement (EOP) elevations(also on a 20-foot grid) for roadways adjacent to and along all property lines, including EOP in cul-de-sacs at 9, 12, and 3 o’clock positions. Please feel free to call or email if there are any questions or concerns. | |||
| ZON | COMPLETE | 08/29/2025 | 08/29/2025 |
| Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| FC IMPACT FEE EMS | ¤62.00 | 10/03/2025 |
| IMPACT FEE FIRE | ¤434.51 | 10/03/2025 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 10/03/2025 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 10/03/2025 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 10/03/2025 |
| WATER METER W/OUT TAP | ¤965.03 | 10/03/2025 |
| PARKS IMPACT FEE | ¤1,828.01 | 10/03/2025 |
| RECLAIM WATER PERMIT INSPECTIO | ¤40.00 | 10/03/2025 |
| SURCHARGE FS 533.721 | ¤12.66 | 10/03/2025 |
| SURCHARGE - FS 468.631 | ¤18.99 | 10/03/2025 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 10/03/2025 |
| SW ENG INSPECTION 80 | ¤80.00 | 10/03/2025 |
| SW ENG PRE APRON | ¤30.00 | 10/03/2025 |
| SW ENG - REVIEW 20 | ¤20.00 | 10/03/2025 |
| SW ENG RES REVIEW 200 | ¤200.00 | 10/03/2025 |
| TRANSPORTATION IMPACT FEE | ¤3,502.00 | 10/03/2025 |
| WASTEWATER PERM INSPECTION | ¤80.00 | 10/03/2025 |
| WASTEWATER PERM REVIEW | ¤25.00 | 10/03/2025 |
| SEWER CAPITAL FACILITY | ¤3,725.72 | 10/03/2025 |
| WATER CAPITAL FACILITY FEE | ¤3,149.89 | 10/03/2025 |
| WATER PERMIT REVIEW | ¤25.00 | 10/03/2025 |
| SITE PLAN 30 | ¤30.00 | 10/03/2025 |
| WATER-METER | ¤874.47 | 10/03/2025 |
| WATER- TURN ON | ¤50.00 | 10/03/2025 |
| ADJUSTMENT 10% | (¤140.67) | 10/03/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 10/03/2025 |
| INSPECTION - RESIDENTIAL | ¤1,072.50 | 10/03/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤304.20 | 10/03/2025 |
| PLAN REVIEW - REVISION | ¤32.50 | 10/03/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | |
| REINSPECTION RESIDENTIAL | ¤40.00 | |
| ADMINISTRATIVE - RESID PP | ¤225.00 | |
| EXTENSION | ¤40.00 | |
| Fees | Total Due: ¤345.00 | Total Paid: ¤22,407.81 |