I want to search for...
Permit #2025081211
Permit Details
Status: INSPECT
| Parcel Id: 48-11-31-1710-00000-0860 |
| Block: 00000 |
| Subdivision: 1710 - |
| Job Phone: 386-236-9610 |
| Location Address: 207 WILLOW OAK WAY |
| Type: PO - POOL |
| Issue Date: 11/10/2025 |
| NOC: RECORDED |
| Applicant name: SAMANTHA JESSICA ALEXANDER |
| Owner: KING ROBERT JR & WENDY H&W |
|
Address PO BOX 39 CASHIERS, NC 28717 |
| Lot: 0860 |
| Contracted Stated Job Value: ¤85,000.00 |
| Job Description: swimming pool & screen enclosure |
| Type: CN |
Contractor
AGUA POOLS AND SPA INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3438 LONGLEAF ROAD , |
CPC1459907 (Exp: 08/31/2026) | 386-492-6910 |
Sub Contractors
CHRISTOPHER I HALL
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
P. O. Box 2413 Bunnell, FL 32110 |
EC13002161 (Exp: 08/31/2028) | (386) 437-2966 | 386-437-5042 |
WILLIAM CARL KLESS
| Status | Location Address | State License Number | Phone |
| ACTIVE |
597 PLEASANT STREET LAKE HELEN, FL 32744 |
CBC1251835 (Exp: 08/31/2026) | 386-228-8933 |
Inspection History
| Type | Request Date | Result | Inspector |
| POOL FINAL | 04/13/2026 | FINAL APPROVED | MCONTRYMAN |
| U -UTILITY RESIDENTIAL FINAL | 04/09/2026 | APPROVED | TLOWE |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 04/08/2026 | APPROVED | FSLADISH |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 04/08/2026 | APPROVED | FSLADISH |
| Note: 4/8/26 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| ROW - FINAL INSPECTION | 04/08/2026 | APPROVED | FSLADISH |
| Note: 4/8/26 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ELECTRIC AND ALARM | 02/23/2026 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 2/23/2026 2:23:07 PM *** | |||
| POOL DECK | 01/14/2026 | APPROVED | MCONTRYMAN |
| FOOTER | 01/14/2026 | APPROVED | MCONTRYMAN |
| STEEL AND GROUND | 12/16/2025 | APPROVED | HCAMACHO |
| Note: 12/15/2025 - PREVIOUS INSPECTION NOTES 1. The plumbing in the spa does not have any pressure at the time of inspection. FBC R4501.12.1 | |||
| STEEL AND GROUND | 12/15/2025 | Disapproved - NO FEE | HCAMACHO |
| Note: 1. The plumbing in the spa does not have any pressure at the time of inspection. FBC R4501.12.1 | |||
| SUBGRADE - FIBERGLASS POOL |
Review History
| Department | Status | Date In | Date Out |
| BADMIN | INFORMATION | 04/02/2026 | 04/02/2026 |
| Note: Marked INFORMATION By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM The main contractor certificate is not active, no edits allowed.. | |||
| BADMIN | INFORMATION | 04/01/2026 | 04/01/2026 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM rename your file to final survey | |||
| MECH | COMPLETE | 11/05/2025 | 11/07/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 11/05/2025 | 11/10/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 11/05/2025 | 11/05/2025 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| BFLOOD | COMPLETE | 10/31/2025 | 10/31/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 10/30/2025 | 10/30/2025 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| MECH | HOLD | 10/30/2025 | 10/31/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide gas riser diagram and list gas subcontractor or put note on plans "Gas By Others" (Second Request) | |||
| BLD | HOLD | 10/30/2025 | 10/31/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Screen engineering calls out for 6 Inch slab. Pool plans do not show a 6 inch slab. Revise screen engineering to coinside with one of the masterfile footing details on plans. (Second Request) | |||
| BFLOOD | HOLD | 10/30/2025 | 10/31/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide gas riser diagram and list gas subcontractor or put note on plans "Gas By Others" (Second Request) | |||
| BFLOOD | HOLD | 08/29/2025 | 09/04/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Flood zone lines and BFE are missing from the Site Plan/Survey. 2. Provide pool deck elevation for proposed pool. 3. Structural systems supporting proposed pool to be designed, connected and anchored to resist flotation, collapse or permanent lateral movement due to structural loads and stresses from flooding equal to the design flood elevation. Provide engineering statement on engineered pool plans confirming design conforms to this section. For previously approved Pool Master Plans, provide engineer's statement signed and sealed by the engineer on separate letterhead referencing this site address and permit number. R322.1.2. 4. Pool equipment shall be installed at or above the design flood elevation provided it is elevated to the extent practical and is anchored to prevent flotation and resist flood forces and is supplied by branch circuits that have ground-fault cicuit interrupter protection. Electrical wiring systems are permitted below the design flood elevation provided they conform to the provisions of the Electrical Code for wet locations. Add note to plans indicating a.) pool equipment will be installed at the highest elevation possible; b.) that all pool equiment will be anchored in a manner to prevent flotation and to resist flood forces; c.) that pool electrical equipment will be provided with branch circuites that are ground-fault circuit interrupter protected and d.) that all electrical equipment to be installed as required for wet locations per the 2020 NEC. R322.1.6 Exception. | |||
| BLD | HOLD | 08/29/2025 | 09/04/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Screen engineering calls out for 6 Inch slab. Pool plans do not show a 6 inch slab. Revise screen engineering to coinside with one of the masterfile footing details on plans. | |||
| ELEC | COMPLETE | 08/29/2025 | 09/04/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | HOLD | 08/29/2025 | 09/03/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide gas riser diagram and list gas subcontractor or put note on plans "Gas By Others" | |||
| RSI | COMPLETE | 08/29/2025 | 08/29/2025 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | HOLD | 08/29/2025 | 09/02/2025 |
| Note: Held By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM Site plan missing setback from equipment pad. Site plan need to remove stamp from previous permit. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADJUSTMENT 10% | (¤25.63) | 11/10/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 11/10/2025 |
| INSPECTION- POOL | ¤160.00 | 11/10/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤66.30 | 11/10/2025 |
| SURCHARGE FS 533.721 | ¤2.31 | 11/10/2025 |
| SURCHARGE - FS 468.631 | ¤3.46 | 11/10/2025 |
| SW ENG INSPECTION 40 | ¤40.00 | 11/10/2025 |
| SW ENG - REVIEW 20 | ¤20.00 | 11/10/2025 |
| SITE PLAN 30 | ¤30.00 | 11/10/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤326.44 |