I want to search for...

Permit #2025090026

Permit Details

Status: INSPECT

Parcel Id: 05-11-31-5918-00000-0500
Block: 00000
Subdivision: 5918 -
Job Phone: 386-547-2998
Location Address: 73 LONGVIEW WAY N
Type: RETWAL - RETAINING WALL
Issue Date: 09/26/2025
NOC: RECORDED
Applicant name: JOHN LEROY HODGINS
Owner: KAPPELMAN ROBERT B & LEIGH ANNE KAPPELMAN H&W

Address

73 LONGVIEW WAY NORTH

PALM COAST, FL 32137

Lot: 0500
Contracted Stated Job Value: ¤20,000.00
Job Description: RETAINING WALL FOR POOL DECK AND STEPS
Type: CN

Contractor

HODGINS CONSTRUCTION INC.
Status Location Address State License Number Phone Fax
ACTIVE

2020 COUNTRY FARMS RD

PORT ORANGE, FL 32128

CGC1507254 (Exp: 08/31/2026) 386-547-2998 386-788-4028

Inspection History

Type Request Date Result Inspector
ROW- FINAL SURVEY/GRADING CERTIFICATION 06/09/2026 APPROVED TPOLACEK
ROW - STORMWATER FINAL 06/09/2026 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
FINAL SURVEY (OFFICE USE ONLY) 05/11/2026 Disapproved - NO FEE TPOLACEK
Note: 05-11-26 TPOLACEK*** FINAL SURVEY MUST BE A TOPOGRAPHICAL SURVEY INCLUDING ELEVATION SHOTS Finished Floor Elevations (FFE): Section 300.01 F(1) V-17 "Final Survey. The Final Survey is used to verify compliance with the Topographic Survey, Lot Grading Plan and Swale Plan. (1) A Final Survey must be submitted in person or uploaded online. If the survey is incomplete, unclear, does not adequately show the drainage patterns, or if the constructed drainage is incorrect, it will be disapproved until corrections are made and resubmitted for review and approval. Once any required field changes have been made and the survey has been revised, the contractor shall submit one (1) signed and sealed revised survey for review. If the field changes and/or the revised survey is accepted, a final inspection may be scheduled by the contractor. Section 300.01 F(1) V-17"
FOOTER 03/04/2026 Approval - Private Provider PPROVIDER
RETAINING WALL FOUNDATION 02/26/2026 Approval - Private Provider PPROVIDER
DOWN CELL 12/30/2025 Approval - Private Provider PPROVIDER
FINAL - BUILDING MISC

Review History

Department Status Date In Date Out
RSI CANCEL 06/08/2026 06/08/2026
BADMIN INFORMATION 06/04/2026 06/08/2026
Note: Marked INFORMATION By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Choose the correct Document type
BADMIN COMPLETE 03/05/2026 03/05/2026
Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM
BADMIN INFORMATION 02/25/2026 02/25/2026
Note: Marked INFORMATION By: JAZMIN ROSARIO - - JROSARIO@PALMCOASTGOV.COM no inspections results submitted for processing
BADMIN HOLD 02/03/2026 02/03/2026
Note: Held By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM MUST SCHEDULE INSPECTION PRIOR TO SUBMITTING INSPECTION RESULT FROM PRIVATE PROVIDER
BLD COMPLETE 09/25/2025 09/26/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BADMIN INFORMATION 09/25/2025 09/25/2025
Note: Marked INFORMATION By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM this private provider paperwork is incorrect the fee owner is not the contracter we have on file
ZON COMPLETE 09/22/2025 09/22/2025
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
RSI COMPLETE 09/22/2025 09/22/2025
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
BLD HOLD 09/22/2025 09/23/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide landing at bottom of stairs 311.7.6 2. Provide width of stairs 311.7.1
BLD HOLD 09/02/2025 09/04/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1.     Indicate soil lateral load per 1610.1. 2.     Indicate surcharge loads per 1610.1 if any. 3.     Indicate wall has been designed per 1807.2.1 through 1807.2.3 with minimum safety factor of 1.5 for sliding and overturning.  4.  Proposed patio encroaches into 100 year floodplain Zone AE.  Engineer to provide statement the patios structural system has been designed, connected and anchored to resist flotation, collapse or permanent lateral movement due to structural loads and stresses from flooding equal to the design flood elevation.  R322.1.2, R322.1.3.   Exception is design according to ASCE 24. 5.  Foundation design of structures in flood-hazard areas to conform with R322.2.3.  Engineer to provide statement patios structural system conforms to Items, 1, 2 and 3 of this section as applicable. 6. Provide details for stairs. Include rise and run, tread depth, tread nosing, material etc...
RSI HOLD 09/02/2025 09/02/2025
Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM NEED TO SHOW WHERE WALL ON SITE PLAN
ZON HOLD 09/02/2025 09/02/2025
Note: Held By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM 1. Site plan needs to show where the wall is located. 2. Site plan missing setbacks rear and side. 3. Plans needs to state that it will be stucco and it will match same color as home.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADMINISTRATIVE - RESID PP75 ¤75.00 09/29/2025
INSPECTION - RESIDENTIAL ¤60.00 09/26/2025
PLAN REVIEW - MISC 32.50 ¤32.50 09/26/2025
SURCHARGE FS 533.721 ¤2.00 09/26/2025
SURCHARGE - FS 468.631 ¤2.00 09/26/2025
SW ENG - INSPECTION 20 ¤20.00 09/26/2025
SW ENG - REVIEW 20 ¤20.00 09/26/2025
ADJUSTMENT 10% (¤12.25) 09/26/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 09/26/2025
Fees Total Due: ¤0.00 Total Paid: ¤229.25