I want to search for...

Permit #2025090465

Permit Details

Status: INSPECT

Parcel Id: 23-11-30-6060-00000-0120
CONDITIONED SPACE: 1891 sqft
GARAGE: 469 sqft
OPENED PORCH (WITH ROOF) : 57 sqft
OPENED PORCH (WITH ROOF) : 163 sqft
Total Square Footage: 2580 sqft
Subdivision: 2312 - WHITEVIEW VILLAGE SUBDIVISION PHASE 1
Job Phone: 904-596-6645
Location Address: 4 WOODLAND PL
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 12/18/2025
NOC: RECORDED
Applicant name: MICHAEL T HOLDER
Owner: KB HOME JACKSONVILLE, LLC

Address

10475 FORTUNE PKWY, STE 100

JACKSONVILLE, FL 32256

Lot: 12
Contracted Stated Job Value: ¤140,000.00
Job Description: SINGLE FAMILY DWELLING
Type: CN

Contractor

KB HOME JACKSONVILLE, LLC
Status Location Address Mailing Address State License Number Phone
ACTIVE

10475 FORTUNE PKWY

JACKSONVILLE, FL 32256

SUITE 100

JACKSONVILLE, FL 32256

CGC1509034 (Exp: 08/31/2026) 904-596-6645

Sub Contractors

BOBBY WAYNE CAMPBELL
Status Location Address State License Number Phone
ACTIVE

117 GUTHRIE ROAD

GREEN COVE SPRINGS, FL 32043

CCC1326752 (Exp: 08/31/2026) 904-200-1600
JAMES E LINTON
Status Location Address State License Number Phone
ACTIVE

200 COLLEGE DR

ORANGE PARK, FL 32065

EC0001152 (Exp: 08/31/2026) 904-272-0272
COREY MICHAEL TENNANT
Status Location Address State License Number Phone
ACTIVE

3370 AGRICULTURAL CNETER DR

ST AUGUSTINE, FL 32092

CAC1819063 (Exp: 08/31/2026) 904-829-8898
BENJAMIN MICHAEL RAY
Status Location Address Mailing Address State License Number Phone Fax
ACTIVE

6310 MABLETON PKWY

JACKSONVILLE, FL 32216

SUITE 1000

MABLETON, GA 30126

CFC1428415 (Exp: 08/31/2026) 904-861-5421 904-861-5426
HARLEY M BRYAN
Status Location Address State License Number Phone
ACTIVE

5223 EDGEWOOD CT

ORMOND BEACH, FL 32174

LI26657 (Exp: 08/31/2028) 386-463-2700

Inspection History

Type Request Date Result Inspector
ROW- FINAL SURVEY/GRADING CERTIFICATION 05/14/2026 Disapproved - NO FEE EMADISON
Note: Gabe, Ed, Rodney and Parren met with grader and site manager for gading pf this lot. right side grade will have inside swale minmum of the .30. No longer drainage flow to back property line to the street behind address 2. Any question see one of inspector listed on this inspection. ** 05/14/26 AS NOTED AFTER SITE MEET WITH BUILDER & GRADER AN INSIDE SWALE WAS TO BE BUILT FOR DRAINAGE ALONG THE RIGHT SIDE PROPERTY LINE WHICH IS NOT INDICATED ON YOUR FINAL SURVEY. THIS INSPECTOR WAS ALSO ON SITE FOR THAT MEETING AS WELL AS ON SITE FOR THIS FINAL SURVEY/LOT GRADING CERTIFICATION THE RIGHT SIDE MEETS A COMMON SWALE WHICH IS VERY FLAT HOLDING WATER AT THE TIME OF THIS INSPECTION. THE INSIDE SWALE WAS REQUIRED TO BE A MINIMUM OF .30 LOWER TO ACCPT THE WATER FROM THE ADJACENT PROPERTY TO THE RIGHT.
BLD - BUILDING FINAL 03/24/2026 FINAL APPROVED HCAMACHO
Note: Inspector Notes from Inspection 2320 Stone work
U-CROSS CONNECTION 03/09/2026 APPROVED - AS NOTED BWRIGHT
Note: NO CC. IRR with potable water using D/C deive
ROW- PROJECT STATUS 03/09/2026 APPROVED - AS NOTED FSLADISH
Note: 3/7/26 MET ON SITE WITH PARREN AND RODNEY TO CHECK GRADE OF THIS LOT. DETERMINED THAT THE LEFT SIDE WITH THE EXCEPTION OF AN AREA THAT NEEDS TO BE RAKED DOWN TO POSITIVE FORWARD FLOWABLE GRADE AROUND THE WATER METER WILL MEET COPC MINIMUM STANDARDS. ON THE LEFT SIDE, PARREN OUTLINED IN PAINT WHERE THE INTERIOR SWALE SHOULD BE LOCATED, APPOXIMATELY 2+ FEET OFF OF THE PROPERTY LINE TO ALLOW DRAINAGE TO HAVE POSITIVE FORWARD FLOW TO CURB AND GUTTER AND NOT HAVE ANY ADVERSE IMPACT ON THE ADJOINING HOME ON THE CORNER. RODNEY CONTACTED MELISSA CM AND COMMUNICATED OUR FINDINGS AND RECOMMENDATION FOR CORRECTION.
ROW- PROJECT STATUS 03/05/2026 Status Check PFLANAGAN
Note: MEETING AT THIS PROJECT TO LOOK AT GRADE AND TO SEE IF GUTTERS WILL BE ABLE TO GO TO FRONT. THEY NEED TO DIG AND PIPE THE GUTTERS TO THE FRONT. GRADE WAS WRONG FROM WHAT WE HAVE DISCUSSED LAST WEEK. IT WILL NEED TO BE REGRADE RIGHT SIDE AGAIN SO ALL WATER ON RIGHT SIDE OF HOUSE WILL FLOW TO CURB AND GUTTER. ALSO NEED TO MAKE A INSIDE SWALE ON THEIR PROPERTY SO WATER WILL NOT IMPACT THE LOT TO THE RIGHT.
ELECTRIC - EARLY POWER 03/04/2026 APPROVED HCAMACHO
ROW- PRE-APRON (PRE-POUR) 02/25/2026 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. . TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, IN THE UPCOMING MONTHS THE DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS WILL BE REQUIRED TO BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. YOU WILL RECEIVE A NEWS BLAST WHEN THIS BECOMES NECESSARY.
LATH/BRICK/ WATER BARRIER 02/24/2026 APPROVED - AS NOTED HCAMACHO
Note: Stone work
LATH/BRICK/ WATER BARRIER 02/09/2026 APPROVED MKRASKI
INSULATION 02/09/2026 APPROVED MKRASKI
ALL ROUGH 02/05/2026 APPROVED MKRASKI
ELECTRIC-TUG 02/03/2026 APPROVED MKRASKI
ALL ROUGH 01/28/2026 Disapproved - NO FEE MKRASKI
Note: 1/28/26 1. Product appoval sheet does not match windows and doors installed 2. E-cal duct layout does not match what is installed 3. Door gaps are to large exceed 1/4'' allowable, solid blocking required FBCR 609.1 4. Vent stack boots missing FBC EC R402.4.1.1 5. Range vent duct is installed upside down, crimped end must go with the flow of air FBC M1502.4.2 6. Elec. panel wiring must be phased properly NEC 210.5(C)(1) NOTE: Please have L-Flashing sealed at the top of roof to wall flashing prior to Lath/brick/waterbarrier.
ROOF VALLEY & METAL 01/28/2026 CANCELLED BY APPLICANT WEB
Note: Inspector Notes from Inspection 2460 1/23/26 1. Remove insulation in bathrooms to expose anchors Will check at all rough 1/20/26 1. Missing 2nd 2x6 at front door header 2. Remove insulation in bathrooms to expose SDWCs and anchors 3. Remove porch beam wall sheathing to expose beams and ensure they are cont. 4. Missing HTT5s on back of home 5. Will check truss engineering at re-inspection, all items marked on plans
ROOF VALLEY & METAL 01/28/2026 APPROVED - AS NOTED JSTEWART
Note: NOTE: Please have L-Flashing sealed at the top of roof to wall flashing prior to Lath/brick/waterbarrier. New inspection due to canceled inspection Inspector Notes from Inspection 2460 1/23/26 1. Remove insulation in bathrooms to expose anchors Will check at all rough 1/20/26 1. Missing 2nd 2x6 at front door header 2. Remove insulation in bathrooms to expose SDWCs and anchors 3. Remove porch beam wall sheathing to expose beams and ensure they are cont. 4. Missing HTT5s on back of home 5. Will check truss engineering at re-inspection, all items marked on plans
ROOF SHEATHING / BRACES/TIES/DOWN CELL 01/23/2026 APPROVED - AS NOTED MKRASKI
Note: 1/23/26 1. Remove insulation in bathrooms to expose anchors Will check at all rough 1/20/26 1. Missing 2nd 2x6 at front door header 2. Remove insulation in bathrooms to expose SDWCs and anchors 3. Remove porch beam wall sheathing to expose beams and ensure they are cont. 4. Missing HTT5s on back of home 5. Will check truss engineering at re-inspection, all items marked on plans
WALL SHEATHING 01/20/2026 APPROVED MKRASKI
ROOF SHEATHING / BRACES/TIES/DOWN CELL 01/20/2026 Disapproved - NO FEE MKRASKI
Note: 1. Missing 2nd 2x6 at front door header 2. Remove insulation in bathrooms to expose SDWCs and anchors 3. Remove porch beam wall sheathing to expose beams and ensure they are cont. 4. Missing HTT5s on back of home 5. Will check truss engineering at re-inspection, all items marked on plans
SEWER TIE IN 01/09/2026 APPROVED MKRASKI
Note: Via Facetime inspection
GRAVITY SEWER TEST 01/09/2026 APPROVED - AS NOTED MKRASKI
Note: Via Facetime inspection
SEWER TIE IN 01/07/2026 CANCELLED BY APPLICANT MKRASKI
Note: Via text from super
GRAVITY SEWER TEST 01/07/2026 CANCELLED BY APPLICANT MKRASKI
Note: Via text from super
WATER METER INSTALLATION REQUEST 01/07/2026 APPROVED CBOWERMASTER
MONOLITHIC SLAB 01/05/2026 APPROVED - AS NOTED MKRASKI
Note: Inspection approved on 1/5/26
PLUMBING 1ST ROUGH UNDERGROUND 12/30/2025 APPROVED MKRASKI
FORMBOARD SURVEY (OFFICE USE ONLY) 12/26/2025 APPROVED RRICKS
ROW- FINAL SURVEY/GRADING CERTIFICATION
Note: 5/14/2026 - PREVIOUS INSPECTION NOTES Gabe, Ed, Rodney and Parren met with grader and site manager for gading pf this lot. right side grade will have inside swale minmum of the .30. No longer drainage flow to back property line to the street behind address 2. Any question see one of inspector listed on this inspection. ** 05/14/26 AS NOTED AFTER SITE MEET WITH BUILDER & GRADER AN INSIDE SWALE WAS TO BE BUILT FOR DRAINAGE ALONG THE RIGHT SIDE PROPERTY LINE WHICH IS NOT INDICATED ON YOUR FINAL SURVEY. THIS INSPECTOR WAS ALSO ON SITE FOR THAT MEETING AS WELL AS ON SITE FOR THIS FINAL SURVEY/LOT GRADING CERTIFICATION THE RIGHT SIDE MEETS A COMMON SWALE WHICH IS VERY FLAT HOLDING WATER AT THE TIME OF THIS INSPECTION. THE INSIDE SWALE WAS REQUIRED TO BE A MINIMUM OF .30 LOWER TO ACCPT THE WATER FROM THE ADJACENT PROPERTY TO THE RIGHT.
ROW - FINAL INSPECTION
U -UTILITY RESIDENTIAL FINAL
ROW - FINAL APRON (AFTER POUR)

Review History

Department Status Date In Date Out
MECH COMPLETE 02/02/2026 02/03/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 01/28/2026 02/02/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
SW1 COMPLETE 12/26/2025 12/26/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 12/26/2025 12/26/2025
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
SW1 COMPLETE 12/11/2025 12/16/2025
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM APPROVING AS NOTE THAT THE DRAINAGE IS OK FOR THE MOST PART BUT THE RIGHT SIDE WILL NEED A LITTLE MORE WORK BUT WE WILL HAVE A MEETING WITH THE GRADER AND THE CM ON SITE AT THE FINAL GRADE STAGE BEFORE SOD IS DOWN TO MAKE SURE DRAINAGE WILL WORK AS CITY IS WANTING.
SW1 HOLD 11/25/2025 12/04/2025
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Grading Comments: - Lot line along improvved lots cannot be changed more than 0.1'. In the back right of the yard there is a proposed grade of 34.2, which is 4' higher than the existing elevations along an improved lot, which also causes a slope more than 4:1. Please revise Additionally, due to this lot being unique and to prevent an excessive amount of water being drained to the back, the city will be requiring gutters to be installed diverting water to the front of the home. Please have CM call me at386-986-4726, so we can discuss in details further.
SW1 HOLD 11/20/2025 11/20/2025
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM This plan does not have an approved grading plan. Please review all hold comments, submit a revised grading plan before submitting a formboard survey. I've had conversations with Fidel and Alex, about the revisions needed before moving forward. Note: In the future when submitting formboard surveys please select formboard survey not foundation.
ZON COMPLETE 11/20/2025 11/20/2025
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
SW1 HOLD 10/24/2025 10/29/2025
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Grading Plan Comments: - Proposed lot is still being proposed 1.6' higher than lot 13. As discussed with our engineers and mentioned in previous comments, lower this FFE to a split difference of lot 13 and lot 11, so the drop is more consistent across lots. - I went out to site and the set back at the front-left foundation to the lot line do not agree. Please feel free to call or email if there any questions or concerns.
SW1 HOLD 10/14/2025 10/21/2025
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Grading Comments: - This lot is being proposed 2' above the adjacent lot 13. Please lower FFE so the lots gradually step down. - This lot is still negatively impacting lot 13. There shall be a minimum of 0.3' from top of swale to the toe of slope. - Between lot 12 and 11 an interior swale along the 5' easement is recommended to accommodate for the decrease in the FFE. Please feel free to call or email if there are any questions or concerns.
ENGIN1 COMPLETE 10/14/2025 10/14/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
SW1 HOLD 10/07/2025 10/07/2025
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Grading Comments: - This lot is negatively impact lot 13 in the back yard. Please revise containing all water to the this lot. - Lot 13 is a vacant lot and the FFE does not match the latest grading plan.
ENGIN1 COMPLETE 10/07/2025 10/08/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
BADMIN COMPLETE 09/11/2025 09/16/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD COMPLETE 09/11/2025 09/16/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
CUSVC COMPLETE 09/11/2025 09/16/2025
Note: Released By: MICHELLE MCPARTLAND - -
ELEC COMPLETE 09/11/2025 09/15/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 09/11/2025 09/12/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS COMPLETE 09/11/2025 09/12/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
LOCATE COMPLETE 09/11/2025 09/17/2025
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 09/11/2025 09/15/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 HOLD 09/11/2025 09/18/2025
Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM 1) THE FFE MUST MATCH THE PLAT NEED TO CHANGE FFE TO MATCH PLAT. 2) THE DRAINAGE OF THIS LOT STATES ON THE PLAT AS A "A" DRAINAGE NEED TO FIX DRAINAGE SO IT MATCHES THE MATER DRAINAGE PLAN
ZON COMPLETE 09/11/2025 09/12/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
URB COMPLETE 09/11/2025 09/15/2025
Note: Released By: MATTHEW SIERRA - (386)286-2002 - MSIERRA@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
FC IMPACT FEE EMS ¤62.00 12/18/2025
IMPACT FEE FIRE ¤434.51 12/18/2025
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 12/18/2025
FC IMPACT FEE LIBRARY ¤268.00 12/18/2025
IMPACT FEE PARKS ¤1,828.01 12/18/2025
IMPACT FEE TRANSPORTATION ¤3,502.00 12/18/2025
WATER METER W/OUT TAP ¤965.03 12/18/2025
SURCHARGE FS 533.721 ¤11.77 12/18/2025
SURCHARGE - FS 468.631 ¤17.66 12/18/2025
SW ENG - FOUNDATION SURVEY ¤20.00 12/18/2025
SW ENG INSPECTION 80 ¤80.00 12/18/2025
SW ENG PRE APRON ¤30.00 12/18/2025
SW ENG - REVIEW 20 ¤20.00 12/18/2025
WASTEWATER PERM INSPECTION ¤80.00 12/18/2025
WASTEWATER PERM REVIEW ¤25.00 12/18/2025
SEWER CAPITAL FACILITY ¤3,824.09 12/18/2025
WATER CAPITAL FACILITY FEE ¤3,241.32 12/18/2025
WATER PERMIT REVIEW ¤25.00 12/18/2025
SITE PLAN 30 ¤30.00 12/18/2025
WATER- TURN ON ¤50.00 12/18/2025
ADJUSTMENT 10% (¤130.79) 12/18/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 12/18/2025
INSPECTION - RESIDENTIAL ¤995.50 12/18/2025
PLAN REVIEW - RESIDENTIAL ¤282.36 12/18/2025
PLAN REVIEW - REVISION ¤32.50
CONTRACTOR CHANGE ¤20.00
RSI GENERAL INSPECTION 32.50 ¤32.50
Fees Total Due: ¤85.00 Total Paid: ¤15,909.46