I want to search for...
Permit #2025090515
Permit Details
Status: COED
| Parcel Id: 07-11-31-7037-01060-0020 |
| GARAGE: 508 sqft |
| OPENED PORCH (WITH ROOF) : 259 sqft |
| CONDITIONED SPACE: 2332 sqft |
| Total Square Footage: 3099 sqft |
| Block: 01060 |
| Subdivision: - |
| Job Phone: 352-433-8382 |
| Location Address: 29 LOUISIANA DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 10/09/2025 |
| NOC: RECORDED |
| Applicant name: ALFREDO E SCHEER |
| Owner: ESTELA SPECS 3 LLC |
|
Address 2601 S BAYSHORE DRIVE COCONUT GROVE, FL 33133 |
|
Address 18TH FLOOR COCONUT GROVE, FL 33133 |
| Lot: 0020 |
| Contracted Stated Job Value: ¤165,000.00 |
| Job Description: Single Family Residential |
| Type: CN |
Contractor
ESTELA LIVING LLC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
237 S. DIXIE HWY, 4TH FLOOR CORAL GABLES, FL 33133 |
CGC1534535 (Exp: 08/31/2026) | 352-433-8382 |
Sub Contractors
JOSEPH HORATIO STRADA JR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3400 ST JOHNS PARKWAY SANFORD, FL 32771 |
EC13003715 (Exp: 08/31/2026) | 877-906-1113 |
JOSEPH H STRADA JR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3400 ST JOHNS PKWY SANFORD, FL 32771 |
CAC043953 (Exp: 08/31/2026) | 877-906-1113 |
DUSTIN L ESTEP
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2041 N HIAWASSEE RD APOPKA, FL 32703 |
CCC1330971 (Exp: 08/31/2026) | 407-702-0206 | 352-988-6629 |
JUAN CARLOS GONZALEZ
| Status | Location Address | State License Number |
| ACTIVE |
1328 COUNTY ROAD 308 CRESCENT CITY, FL 32112 |
RF11067806 (Exp: 08/31/2027) |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 04/17/2026 | FINAL APPROVED | JSTEWART |
| Note: 4/16/2026 - PREVIOUS INSPECTION NOTES 4/16/26 1. Broken window in master bedroom 4/15/2026 - PREVIOUS INSPECTION NOTES 4/14/2026 - PREVIOUS INSPECTION NOTES No Hot water in building, will need to test left hand direction flow of hot water. FPBC 607.4 / FBCR P2705.1 – 4 | |||
| BLD - BUILDING FINAL | 04/16/2026 | Disapproved - NO FEE | MCONTRYMAN |
| Note: 4/16/26 1. Broken window in master bedroom 4/15/2026 - PREVIOUS INSPECTION NOTES 4/14/2026 - PREVIOUS INSPECTION NOTES No Hot water in building, will need to test left hand direction flow of hot water. FPBC 607.4 / FBCR P2705.1 – 4 | |||
| BLD - BUILDING FINAL | 04/15/2026 | CANCELLED BY APPLICANT | JSTEWART |
| Note: 4/14/2026 - PREVIOUS INSPECTION NOTES No Hot water in building, will need to test left hand direction flow of hot water. FPBC 607.4 / FBCR P2705.1 – 4 | |||
| ROW - FINAL INSPECTION | 04/14/2026 | APPROVED - AS NOTED | FSLADISH |
| Note: 4/14/26 REQUIRED CORRECTIONS COMPLETED AT THE TIME OF THIS INSPECTION. SWALE HAS BEEN RAISED AS REQUIRED BY PREVIOUS INSPECTORS NOTES. APPROVING AS NOTED. PHOTO FOR REFERENCE. _______________________________________________________________________________________________________________________________ 3/25/2026 - PREVIOUS INSPECTION NOTES 03-25-26 TPOLACEK*** FRONT SWALE HAS NOT BEEN CORRECTED, THERE IS A GAP ALONG LEFT SIDE BY PEP TANKS THAT NEEDS TO HAVE SOD AND BE FILLED IN, ALONG VACANT ALL TRASH MUST BE REMOVED AND ALL BARE GROUND SEEDED WITH STRAW. SEE PHOTOS ATTACHED. Lot Grading Permit Requirements (Improved Properties) Sec 300.03 F4-A / V-22 Sec 300.03 F4-The Stormwater Final Inspection will include visual inspection of the site and adjacent properties for debris, proper clean up and repair to damaged terrain. Bare earth on the site or surrounding properties must be sodded, or seeded with pine straw cover, to prevent soil erosion. Bare earth and damage to any City roadside swales, drainage ditches, canals or other drainage conveyances must be graded to the proper elevation and sodded to prevent soil erosion. Road damage in the area of construction is also attributable to the Permittee, unless a preconstruction inspection has previously documented the damage Lot Grading Permit Requirements (Improved Properties) Sec 300.03 C-B / V-20 B) Sec 300.03 C-B. The purpose and scope of the site work being proposed, such as filling in low spots that accumulate Stormwater. The rear yard is required to drain to the front roadside swale, unless the Lot Grading Plan demonstrates an approved rear yard drainage system into an appropriate water body or outfall. Flooding or draining onto adjacent properties will not be allowed. Inspector Notes from Inspection 9465 ** 03/24/26 BUILDER NEEDS TO RAISE THE ROAD SIDE SWALE ON LEFT SIDE TO HAVE A POSITIVE FLOW OF STORMWATER TO THE OUTFALL, CURRENTLY SWALE IS LOW TO PROPERTY LINE. NEED TO COME OUT OF CULVERT AT A 2:1 SLOPE ** NOTE PINK PAINT IN SWALE | |||
| BLD - BUILDING FINAL | 04/14/2026 | Disapproved - NO FEE | JSTEWART |
| Note: No Hot water in building, will need to test left hand direction flow of hot water. FPBC 607.4 / FBCR P2705.1 – 4 | |||
| U -UTILITY RESIDENTIAL FINAL | 03/25/2026 | FINAL APPROVED | BHAINES |
| Note: Inspector Notes from Inspection 9035 No CC. IRR with well | |||
| ROW - FINAL INSPECTION | 03/25/2026 | Disapproved -FEE REQUIRED | TPOLACEK |
| Note: 03-25-26 TPOLACEK*** FRONT SWALE HAS NOT BEEN CORRECTED, THERE IS A GAP ALONG LEFT SIDE BY PEP TANKS THAT NEEDS TO HAVE SOD AND BE FILLED IN, ALONG VACANT ALL TRASH MUST BE REMOVED AND ALL BARE GROUND SEEDED WITH STRAW. SEE PHOTOS ATTACHED. Lot Grading Permit Requirements (Improved Properties) Sec 300.03 F4-A / V-22 Sec 300.03 F4-The Stormwater Final Inspection will include visual inspection of the site and adjacent properties for debris, proper clean up and repair to damaged terrain. Bare earth on the site or surrounding properties must be sodded, or seeded with pine straw cover, to prevent soil erosion. Bare earth and damage to any City roadside swales, drainage ditches, canals or other drainage conveyances must be graded to the proper elevation and sodded to prevent soil erosion. Road damage in the area of construction is also attributable to the Permittee, unless a preconstruction inspection has previously documented the damage Lot Grading Permit Requirements (Improved Properties) Sec 300.03 C-B / V-20 B) Sec 300.03 C-B. The purpose and scope of the site work being proposed, such as filling in low spots that accumulate Stormwater. The rear yard is required to drain to the front roadside swale, unless the Lot Grading Plan demonstrates an approved rear yard drainage system into an appropriate water body or outfall. Flooding or draining onto adjacent properties will not be allowed. Inspector Notes from Inspection 9465 ** 03/24/26 BUILDER NEEDS TO RAISE THE ROAD SIDE SWALE ON LEFT SIDE TO HAVE A POSITIVE FLOW OF STORMWATER TO THE OUTFALL, CURRENTLY SWALE IS LOW TO PROPERTY LINE. NEED TO COME OUT OF CULVERT AT A 2:1 SLOPE ** NOTE PINK PAINT IN SWALE | |||
| ROW - FINAL APRON (AFTER POUR) | 03/25/2026 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVEDInspector Notes from Inspection 9465 ** 03/24/26 BUILDER NEEDS TO RAISE THE ROAD SIDE SWALE ON LEFT SIDE TO HAVE A POSITIVE FLOW OF STORMWATER TO THE OUTFALL, CURRENTLY SWALE IS LOW TO PROPERTY LINE. NEED TO COME OUT OF CULVERT AT A 2:1 SLOPE ** NOTE PINK PAINT IN SWALE | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 03/24/2026 | APPROVED | EMADISON |
| Note: | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 03/24/2026 | APPROVED - AS NOTED | EMADISON |
| Note: ** 03/24/26 BUILDER NEEDS TO RAISE THE ROAD SIDE SWALE ON LEFT SIDE TO HAVE A POSITIVE FLOW OF STORMWATER TO THE OUTFALL, CURRENTLY SWALE IS LOW TO PROPERTY LINE. NEED TO COME OUT OF CULVERT AT A 2:1 SLOPE ** NOTE PINK PAINT IN SWALE | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 03/20/2026 | Disapproved - NO FEE | TPOLACEK |
| Note: 03-20-28 TPOLACEK*** YOU ARE REQUIRED TO UPLOAD A LOT GRADING AND DRAINAGE CHECLIST FOR REVIEW AND APPROVAL BEFORE ANY INSPECTIONS CAN BE COMPLETED. New document type: Final Lot Grading & Drainage Certification • Begins 7/1/25 – all 1 and 2 family dwelling permits submitted on or after 7/1/25 • Actual Lot Grading & Drainage Certification IS NOT submitted at time of permit application • Lot Grading & Drainage Certification submitted near completion of the home after installation of landscaping / sod and must include the Final Survey • Same review process as current • Lot Grading & Drainage Certification must be on City Form – if not on City form permit revision / submittal will be rejected. • Lot Grading & Drainage Certification signed and sealed (digitally) by a Florida licensed Professional Engineer – no exceptions • If not by a PE – Lot Grading & Drainage Certification will be rejected | |||
| U-CROSS CONNECTION | 03/19/2026 | APPROVED - AS NOTED | BWRIGHT |
| Note: No CC. IRR with well | |||
| ROW- PRE-APRON (PRE-POUR) | 02/18/2026 | APPROVED - AS NOTED | TPOLACEK |
| Note: 02-18-26 TPOLACEK*** ON THE RIGHT SIDE APRON WING, THE FORM BOARD COMING FROM THE ROAD EDGE AT THE PIPE IS HIGHER THAN THE EDGE OF DRIVEWAY FORMBOARD BEHIND THE PIPE. BUILDER MUST ENSURE DRIVEWAY SLOPE TOWARDS THE ROAD FROMT THE GARAGE ALL THE TO THE ROAD EDGE BEFORE POURING ANY CONCRETE. IF DRIVEWAY IS SLOPE BACK AT THE AFTER POUR BUILDER MAY NEED TO REMOVE CONCRETE AND REPOUR APRON. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. WOOD CONTROL JOINTS ARE PROHIBITED IN THE RIGHT-OF-WAY. SAWCUT SHALL BE PROVIDED AT THE EDGE OF ROW AND EVERY 12' THEREAFTER, OR A MINIMUM OF 2 SAWCUTS WHICHEVER IS GREATER" | |||
| ELECTRIC - EARLY POWER | 02/17/2026 | APPROVED - AS NOTED | MKRASKI |
| Note: Emailed FPL @ 11:40am | |||
| GRAVITY SEWER TEST | 02/06/2026 | APPROVED | CVANSTRAHLEN |
| Note: Inspector Notes from Inspection 2060 WATER SERVICE NOT RAN YET | |||
| SEWER TIE IN | 02/06/2026 | APPROVED | CVANSTRAHLEN |
| Note: Inspector Notes from Inspection 2060 WATER SERVICE NOT RAN YET | |||
| PEP TANK INSTALLATION REQUEST | 01/22/2026 | APPROVED | CBOWERMASTER |
| INSULATION | 01/16/2026 | APPROVED | JSTEWART |
| Note: Inspector Notes from Inspection 2320 Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 12/30/2025 10:09:51 AM *** 12/30/25: ALL MUST BE COMPLETE PRIOR TO INSULATION INSPECTION. 1). No 5ft head pressure. FBC-P2503.5.1 2). Missing fireblocking above electrical panel in garage. (missing fireblocking can be seen from the back side of the wall). FBC-R302.11 3). garage 2" x 6" wall right side studs exceed the 16" OC as required on plans. 4). Load bearing walls have Simpson brackets installed in lieu of the SDWC 15600 scfrews as shown on plans. Engineering Revision required. 5). Front door marked temporary (frame has over 1/4" maximum shim spacing on jambs - FBCR 609.1). Permanent door will need to be installed by Insulation or a window nailing inspection will be added. Inspector Notes from Inspection 2450 Previous Notes not rectified.....required at All Rough. 1. Missing SDW 15600 screws from stud to top plate, per plan page S-5 2. S-5 calls for 2x6 wall in back of garage area with (3) 2x6 post under truss A1. 2x4 wall with 2x4 post is there instead. Note: Or submit a engineer letter stating 2x4 wall and post is sufficient for down/uplift loads, Prior to All Rough.Inspector Notes from Inspection 2467 Previous Notes not rectified.....required at All Rough. 1. Missing SDW 15600 screws from stud to top plate, per plan page S-5 2. S-5 calls for 2x6 wall in back of garage area with (3) 2x6 post under truss A1. 2x4 wall with 2x4 post is there instead. Note: Or submit a engineer letter stating 2x4 wall and post is sufficient for down/uplift loads, Prior to All Rough. New inspection due to canceled inspection Inspector Notes from Inspection 2460 11/25/25 1. Missing SDW 15600 screws from stud to top plate, per plan page S-5 2. S-5 calls for 2x6 wall in back of garage area with (3) 2x6 post under truss A1. 2x4 wall with 2x4 post is there instead. Large plans show different, but details are on smaller plans. | |||
| INSULATION | 01/15/2026 | Disapproved -FEE REQUIRED | JSTEWART |
| Note: Previous Note Listed multiple times has not been rectified..... Structural plans page S-5 calls for 2x6 wall in back of garage area with (3) 2x6 post under double girder truss A1. 2x4 wall with 2x4 post is there instead. Note: Or submit a engineer letter stating 2x4 wall and post is sufficient for down/uplift loads,( Structural Plans take presidence over Architectural drawing.) This will need to be rectified before approval of insulation. Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 12/30/2025 10:09:51 AM *** 12/30/25: ALL MUST BE COMPLETE PRIOR TO INSULATION INSPECTION. 1). No 5ft head pressure. FBC-P2503.5.1 2). Missing fireblocking above electrical panel in garage. (missing fireblocking can be seen from the back side of the wall). FBC-R302.11 3). garage 2" x 6" wall right side studs exceed the 16" OC as required on plans. 4). Load bearing walls have Simpson brackets installed in lieu of the SDWC 15600 scfrews as shown on plans. Engineering Revision required. 5). Front door marked temporary (frame has over 1/4" maximum shim spacing on jambs - FBCR 609.1). Permanent door will need to be installed by Insulation or a window nailing inspection will be added. Inspector Notes from Inspection 2450 Previous Notes not rectified.....required at All Rough. 1. Missing SDW 15600 screws from stud to top plate, per plan page S-5 2. S-5 calls for 2x6 wall in back of garage area with (3) 2x6 post under truss A1. 2x4 wall with 2x4 post is there instead. Note: Or submit a engineer letter stating 2x4 wall and post is sufficient for down/uplift loads, Prior to All Rough.Inspector Notes from Inspection 2467 Previous Notes not rectified.....required at All Rough. 1. Missing SDW 15600 screws from stud to top plate, per plan page S-5 2. S-5 calls for 2x6 wall in back of garage area with (3) 2x6 post under truss A1. 2x4 wall with 2x4 post is there instead. Note: Or submit a engineer letter stating 2x4 wall and post is sufficient for down/uplift loads, Prior to All Rough. New inspection due to canceled inspection Inspector Notes from Inspection 2460 11/25/25 1. Missing SDW 15600 screws from stud to top plate, per plan page S-5 2. S-5 calls for 2x6 wall in back of garage area with (3) 2x6 post under truss A1. 2x4 wall with 2x4 post is there instead. Large plans show different, but details are on smaller plans. | |||
| LATH/BRICK/ WATER BARRIER | 01/15/2026 | APPROVED - AS NOTED | JSTEWART |
| Note: Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 12/30/2025 10:09:51 AM *** 12/30/25: ALL MUST BE COMPLETE PRIOR TO INSULATION INSPECTION. 1). No 5ft head pressure. FBC-P2503.5.1 2). Missing fireblocking above electrical panel in garage. (missing fireblocking can be seen from the back side of the wall). FBC-R302.11 3). garage 2" x 6" wall right side studs exceed the 16" OC as required on plans. 4). Load bearing walls have Simpson brackets installed in lieu of the SDWC 15600 scfrews as shown on plans. Engineering Revision required. 5). Front door marked temporary (frame has over 1/4" maximum shim spacing on jambs - FBCR 609.1). Permanent door will need to be installed by Insulation or a window nailing inspection will be added. Inspector Notes from Inspection 2450 Previous Notes not rectified.....required at All Rough. 1. Missing SDW 15600 screws from stud to top plate, per plan page S-5 2. S-5 calls for 2x6 wall in back of garage area with (3) 2x6 post under truss A1. 2x4 wall with 2x4 post is there instead. Note: Or submit a engineer letter stating 2x4 wall and post is sufficient for down/uplift loads, Prior to All Rough.Inspector Notes from Inspection 2467 Previous Notes not rectified.....required at All Rough. 1. Missing SDW 15600 screws from stud to top plate, per plan page S-5 2. S-5 calls for 2x6 wall in back of garage area with (3) 2x6 post under truss A1. 2x4 wall with 2x4 post is there instead. Note: Or submit a engineer letter stating 2x4 wall and post is sufficient for down/uplift loads, Prior to All Rough. New inspection due to canceled inspection Inspector Notes from Inspection 2460 11/25/25 1. Missing SDW 15600 screws from stud to top plate, per plan page S-5 2. S-5 calls for 2x6 wall in back of garage area with (3) 2x6 post under truss A1. 2x4 wall with 2x4 post is there instead. Large plans show different, but details are on smaller plans. | |||
| ALL ROUGH | 12/30/2025 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 12/30/2025 10:09:51 AM *** 12/30/25: ALL MUST BE COMPLETE PRIOR TO INSULATION INSPECTION. 1). No 5ft head pressure. FBC-P2503.5.1 2). Missing fireblocking above electrical panel in garage. (missing fireblocking can be seen from the back side of the wall). FBC-R302.11 3). garage 2" x 6" wall right side studs exceed the 16" OC as required on plans. 4). Load bearing walls have Simpson brackets installed in lieu of the SDWC 15600 scfrews as shown on plans. Engineering Revision required. 5). Front door marked temporary (frame has over 1/4" maximum shim spacing on jambs - FBCR 609.1). Permanent door will need to be installed by Insulation or a window nailing inspection will be added. Inspector Notes from Inspection 2450 Previous Notes not rectified.....required at All Rough. 1. Missing SDW 15600 screws from stud to top plate, per plan page S-5 2. S-5 calls for 2x6 wall in back of garage area with (3) 2x6 post under truss A1. 2x4 wall with 2x4 post is there instead. Note: Or submit a engineer letter stating 2x4 wall and post is sufficient for down/uplift loads, Prior to All Rough.Inspector Notes from Inspection 2467 Previous Notes not rectified.....required at All Rough. 1. Missing SDW 15600 screws from stud to top plate, per plan page S-5 2. S-5 calls for 2x6 wall in back of garage area with (3) 2x6 post under truss A1. 2x4 wall with 2x4 post is there instead. Note: Or submit a engineer letter stating 2x4 wall and post is sufficient for down/uplift loads, Prior to All Rough. New inspection due to canceled inspection Inspector Notes from Inspection 2460 11/25/25 1. Missing SDW 15600 screws from stud to top plate, per plan page S-5 2. S-5 calls for 2x6 wall in back of garage area with (3) 2x6 post under truss A1. 2x4 wall with 2x4 post is there instead. Large plans show different, but details are on smaller plans. | |||
| WALL SHEATHING | 12/11/2025 | APPROVED - AS NOTED | JSTEWART |
| Note: Previous Notes not rectified.....required at All Rough. 1. Missing SDW 15600 screws from stud to top plate, per plan page S-5 2. S-5 calls for 2x6 wall in back of garage area with (3) 2x6 post under truss A1. 2x4 wall with 2x4 post is there instead. Note: Or submit a engineer letter stating 2x4 wall and post is sufficient for down/uplift loads, Prior to All Rough.Inspector Notes from Inspection 2467 Previous Notes not rectified.....required at All Rough. 1. Missing SDW 15600 screws from stud to top plate, per plan page S-5 2. S-5 calls for 2x6 wall in back of garage area with (3) 2x6 post under truss A1. 2x4 wall with 2x4 post is there instead. Note: Or submit a engineer letter stating 2x4 wall and post is sufficient for down/uplift loads, Prior to All Rough. New inspection due to canceled inspection Inspector Notes from Inspection 2460 11/25/25 1. Missing SDW 15600 screws from stud to top plate, per plan page S-5 2. S-5 calls for 2x6 wall in back of garage area with (3) 2x6 post under truss A1. 2x4 wall with 2x4 post is there instead. Large plans show different, but details are on smaller plans. | |||
| ROOF VALLEY & METAL | 12/01/2025 | APPROVED - AS NOTED | JSTEWART |
| Note: Previous Notes not rectified.....required at All Rough. 1. Missing SDW 15600 screws from stud to top plate, per plan page S-5 2. S-5 calls for 2x6 wall in back of garage area with (3) 2x6 post under truss A1. 2x4 wall with 2x4 post is there instead. Note: Or submit a engineer letter stating 2x4 wall and post is sufficient for down/uplift loads, Prior to All Rough. New inspection due to canceled inspection Inspector Notes from Inspection 2460 11/25/25 1. Missing SDW 15600 screws from stud to top plate, per plan page S-5 2. S-5 calls for 2x6 wall in back of garage area with (3) 2x6 post under truss A1. 2x4 wall with 2x4 post is there instead. Large plans show different, but details are on smaller plans. | |||
| ROOF VALLEY & METAL | 11/26/2025 | CANCELLED BY APPLICANT | WEB |
| Note: Inspector Notes from Inspection 2460 11/25/25 1. Missing SDW 15600 screws from stud to top plate, per plan page S-5 2. S-5 calls for 2x6 wall in back of garage area with (3) 2x6 post under truss A1. 2x4 wall with 2x4 post is there instead. Large plans show different, but details are on smaller plans. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 11/25/2025 | APPROVED - AS NOTED | MCONTRYMAN |
| Note: 11/25/25 1. Missing SDW 15600 screws from stud to top plate, per plan page S-5 2. S-5 calls for 2x6 wall in back of garage area with (3) 2x6 post under truss A1. 2x4 wall with 2x4 post is there instead. Large plans show different, but details are on smaller plans. | |||
| TIE BEAM / LINTEL | 11/20/2025 | APPROVED | JSTEWART |
| MONOLITHIC SLAB | 11/12/2025 | APPROVED | JSTEWART |
| PLUMBING 1ST ROUGH UNDERGROUND | 11/05/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: WATER SERVICE NOT RAN YET | |||
| ROW - DRAINAGE | 11/05/2025 | APPROVED | TPOLACEK |
| Note: 11-05-25 TPOLACEK*** AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 11/4/2025 - PREVIOUS INSPECTION NOTES 11-04-25 TPOLACEK*** BUILDER STILL NEED TO ADD TEMPORARY PIPE AND OPEN SWALE. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 10/30/2025 - PREVIOUS INSPECTION NOTES ** 10/30/25 BUILDER REQUIRED TO OPEN THE ROADSIDE SWALE (ROW) AND ESTABLISH A CONSTRUCTION ENTRANCE WITH SILT FENCE INSTALL A TEMPORARY CULVERY PIPE A MINIMUM OF 12 INCHES IN DIAMETER ** SEE ATTACHED PHOTOS ** FOLLOW UP INSPECTION ON 11/04/25 | |||
| ROW - DRAINAGE | 11/04/2025 | Disapproved -FEE REQUIRED | TPOLACEK |
| Note: 11-04-25 TPOLACEK*** BUILDER STILL NEED TO ADD TEMPORARY PIPE AND OPEN SWALE. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 10/30/2025 - PREVIOUS INSPECTION NOTES ** 10/30/25 BUILDER REQUIRED TO OPEN THE ROADSIDE SWALE (ROW) AND ESTABLISH A CONSTRUCTION ENTRANCE WITH SILT FENCE INSTALL A TEMPORARY CULVERY PIPE A MINIMUM OF 12 INCHES IN DIAMETER ** SEE ATTACHED PHOTOS ** FOLLOW UP INSPECTION ON 11/04/25 | |||
| FORMBOARD SURVEY (OFFICE USE ONLY) | 11/04/2025 | APPROVED | PFLANAGAN |
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 11/03/2025 | APPROVED | PKNAPIK |
| ROW - DRAINAGE | 10/30/2025 | Disapproved -FEE REQUIRED | EMADISON |
| Note: ** 10/30/25 BUILDER REQUIRED TO OPEN THE ROADSIDE SWALE (ROW) AND ESTABLISH A CONSTRUCTION ENTRANCE WITH SILT FENCE INSTALL A TEMPORARY CULVERY PIPE A MINIMUM OF 12 INCHES IN DIAMETER ** SEE ATTACHED PHOTOS ** FOLLOW UP INSPECTION ON 11/04/25 | |||
| WATER METER INSTALLATION REQUEST | 10/29/2025 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 01/16/2026 | 01/16/2026 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 11/04/2025 | 11/04/2025 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 11/04/2025 | 11/04/2025 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 10/31/2025 | 11/03/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 09/12/2025 | 09/18/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 09/12/2025 | 09/22/2025 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 09/12/2025 | 09/15/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 09/12/2025 | 09/12/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 09/12/2025 | 09/15/2025 |
| LOCATE | COMPLETE | 09/12/2025 | 09/19/2025 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 09/12/2025 | 09/15/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 09/12/2025 | 09/15/2025 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 09/12/2025 | 09/15/2025 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 09/12/2025 | 09/24/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 04/15/2026 |
| RSI REINSPECTION 1 | ¤35.00 | 04/15/2026 |
| RSI REINSPECTION 1 | ¤35.00 | 04/15/2026 |
| RSI REINSPECTION 1 | ¤35.00 | 04/15/2026 |
| IMPACT FEE TRANSPORTATION | ¤1,916.00 | 10/09/2025 |
| PEP TANK INSTALL | ¤756.74 | 10/09/2025 |
| WASTEWATER MAIN EXTENSION IMPA | ¤2,385.00 | 10/09/2025 |
| SURCHARGE - FS 468.631 | ¤21.42 | 10/09/2025 |
| SURCHARGE FS 533.721 | ¤14.28 | 10/09/2025 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 10/09/2025 |
| SW ENG INSPECTION 80 | ¤80.00 | 10/09/2025 |
| SW ENG - REVIEW 20 | ¤20.00 | 10/09/2025 |
| SW ENG PRE APRON | ¤30.00 | 10/09/2025 |
| SW ENG RES REVIEW 200 | ¤200.00 | 10/09/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤343.98 | 10/09/2025 |
| ADJUSTMENT 10% | (¤158.67) | 10/09/2025 |
| INSPECTION - RESIDENTIAL | ¤1,212.75 | 10/09/2025 |
| WATER- TURN ON | ¤50.00 | 10/09/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 10/09/2025 |
| FC IMPACT FEE EMS | ¤62.00 | 10/09/2025 |
| IMPACT FEE FIRE | ¤434.51 | 10/09/2025 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 10/09/2025 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 10/09/2025 |
| IMPACT FEE PARKS | ¤1,828.01 | 10/09/2025 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 10/09/2025 |
| WATER METER W/ TAP | ¤2,326.93 | 10/09/2025 |
| SEWER CREDIT | (¤4,782.75) | 10/09/2025 |
| WASTEWATER PERM REVIEW | ¤25.00 | 10/09/2025 |
| WASTEWATER PERM INSPECTION | ¤80.00 | 10/09/2025 |
| SEWER CAPITAL FACILITY | ¤4,415.00 | 10/09/2025 |
| WATER CAPITAL FACILITY FEE | ¤3,790.49 | 10/09/2025 |
| WATER PERMIT REVIEW | ¤25.00 | 10/09/2025 |
| WATER MAIN EXTENSION IMPACT | ¤917.27 | 10/09/2025 |
| SITE PLAN 30 | ¤30.00 | 10/09/2025 |
| SITE PLAN 30 | ¤30.00 | 09/23/2025 |
| SITE PLAN 30 | (¤30.00) | 09/23/2025 |
| WATER MAIN EXTENSION IMPACT | ¤917.27 | 09/23/2025 |
| WATER MAIN EXTENSION IMPACT | (¤917.27) | 09/23/2025 |
| WATER CAPITAL FACILITY FEE | ¤3,790.49 | 09/23/2025 |
| WATER PERMIT REVIEW | ¤25.00 | 09/23/2025 |
| WATER PERMIT REVIEW | (¤25.00) | 09/23/2025 |
| WATER CAPITAL FACILITY FEE | (¤3,790.49) | 09/23/2025 |
| WASTEWATER PERM REVIEW | (¤25.00) | 09/23/2025 |
| WASTEWATER PERM REVIEW | ¤25.00 | 09/23/2025 |
| SEWER CAPITAL FACILITY | ¤4,415.00 | 09/23/2025 |
| SEWER CAPITAL FACILITY | (¤4,415.00) | 09/23/2025 |
| WASTEWATER PERM INSPECTION | ¤80.00 | 09/23/2025 |
| WASTEWATER PERM INSPECTION | (¤80.00) | 09/23/2025 |
| SEWER CREDIT | (¤4,782.75) | 09/23/2025 |
| SEWER CREDIT | ¤4,782.75 | 09/23/2025 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 09/23/2025 |
| IMPACT FEE TRANSPORTATION | ¤1,916.00 | 09/23/2025 |
| IMPACT FEE TRANSPORTATION | (¤1,916.00) | 09/23/2025 |
| IMPACT FEE SCHOOL | (¤5,450.00) | 09/23/2025 |
| FC IMPACT FEE LIBRARY | (¤268.00) | 09/23/2025 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 09/23/2025 |
| IMPACT FEE PARKS | ¤1,828.01 | 09/23/2025 |
| IMPACT FEE PARKS | (¤1,828.01) | 09/23/2025 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 09/23/2025 |
| FC IMPACT FEE LAW ENFORCEMENT | (¤218.00) | 09/23/2025 |
| IMPACT FEE FIRE | ¤434.51 | 09/23/2025 |
| IMPACT FEE FIRE | (¤434.51) | 09/23/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 09/23/2025 |
| INSPECTION - RESIDENTIAL | ¤1,212.75 | 09/23/2025 |
| INSPECTION - RESIDENTIAL | (¤1,212.75) | 09/23/2025 |
| ADJUSTMENT 10% | (¤158.67) | 09/23/2025 |
| ADJUSTMENT 10% | ¤158.67 | 09/23/2025 |
| WATER- TURN ON | ¤50.00 | 09/23/2025 |
| WATER- TURN ON | (¤50.00) | 09/23/2025 |
| PLAN REVIEW - RESIDENTIAL | (¤343.98) | 09/23/2025 |
| ADMINISTRATIVE RESIDENTIAL | (¤30.00) | 09/23/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤343.98 | 09/23/2025 |
| FC IMPACT FEE EMS | ¤62.00 | 09/23/2025 |
| FC IMPACT FEE EMS | (¤62.00) | 09/23/2025 |
| WATER METER W/ TAP | ¤2,326.93 | 09/23/2025 |
| WATER METER W/ TAP | (¤2,326.93) | 09/23/2025 |
| SW ENG - REVIEW 20 | (¤20.00) | 09/23/2025 |
| SW ENG - REVIEW 20 | ¤20.00 | 09/23/2025 |
| SW ENG RES REVIEW 200 | ¤200.00 | 09/23/2025 |
| SW ENG RES REVIEW 200 | (¤200.00) | 09/23/2025 |
| SW ENG INSPECTION 80 | ¤80.00 | 09/23/2025 |
| SW ENG PRE APRON | ¤30.00 | 09/23/2025 |
| SW ENG PRE APRON | (¤30.00) | 09/23/2025 |
| SW ENG INSPECTION 80 | (¤80.00) | 09/23/2025 |
| SURCHARGE - FS 468.631 | (¤21.42) | 09/23/2025 |
| SURCHARGE - FS 468.631 | ¤21.42 | 09/23/2025 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 09/23/2025 |
| SW ENG - FOUNDATION SURVEY | (¤20.00) | 09/23/2025 |
| WASTEWATER MAIN EXTENSION IMPA | ¤2,385.00 | 09/23/2025 |
| SURCHARGE FS 533.721 | ¤14.28 | 09/23/2025 |
| SURCHARGE FS 533.721 | (¤14.28) | 09/23/2025 |
| PEP TANK INSTALL | ¤756.74 | 09/23/2025 |
| PEP TANK INSTALL | (¤756.74) | 09/23/2025 |
| WASTEWATER MAIN EXTENSION IMPA | (¤2,385.00) | 09/23/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤22,153.96 |