I want to search for...

Permit #2025090525

Permit Details

Status: COED

Parcel Id: 32-11-31-5390-00000-1340
CONDITIONED SPACE: 1422 sqft
OPENED PORCH (WITH ROOF) : 115 sqft
GARAGE: 415 sqft
Total Square Footage: 1952 sqft
Subdivision: 2358 - SABAL PRESERVE AT TOWN CENTER
Job Phone: 904-540-7206
Location Address: 9 SPARROW ST
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 09/26/2025
NOC: RECORDED
Applicant name: JOHN RYAN O DOWD
Owner: STARLIGHT HOMES FLORIDA LLC

Address

3820 MANSELL ROAD

ALPHARETTA, GA 30022

Address

SUITE 400

ALPHARETTA, GA 30022

Lot: 134
Contracted Stated Job Value: ¤107,360.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

STARLIGHT HOMES FLORIDA LLC
Status Location Address Mailing Address State License Number Phone
ACTIVE

1064 GREENWOOD BLVD

LAKE MARY, FL 32746

STE 124

LAKE MARY, FL 32746

CGC1537818 (Exp: 08/31/2026) 407-647-3700

Sub Contractors

DUSTIN L ESTEP
Status Location Address State License Number Phone Fax
ACTIVE

2041 N HIAWASSEE RD

APOPKA, FL 32703

CCC1330971 (Exp: 08/31/2026) 407-702-0206 352-988-6629
BRETT CHRISTIAN GIBSON
Status Location Address State License Number Phone
ACTIVE

250 SEGOVIA RD

ST AUGUSTINE, FL 32086

CAC1818423 (Exp: 08/31/2026) 904-229-8131
MICHAEL CHARLES SCHWEITZER
Status Location Address State License Number Phone
ACTIVE

815 HAINES STREET

JACKSONVILLE , FL 32206

EC13013052 (Exp: 08/31/2026) 904-367-2175
BRITT MICHAEL JENKINS
Status Location Address State License Number Phone
ACTIVE

86 COLUMBIA DR

POOLER, GA 31322

CFC1430770 (Exp: 08/31/2026) 912-330-8151

Inspection History

Type Request Date Result Inspector
WATER METER INSTALLATION REQUEST 01/29/2026 APPROVED CBOWERMASTER
U-CROSS CONNECTION 01/29/2026 APPROVED BWRIGHT
ROW - FINAL APRON (AFTER POUR) 01/29/2026 APPROVED FSLADISH
Note: 1/29/26 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ROW - FINAL INSPECTION 01/29/2026 APPROVED FSLADISH
Note: 1/29/26 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
U -UTILITY RESIDENTIAL FINAL 01/29/2026 FINAL APPROVED BWRIGHT
ROW- FINAL SURVEY/GRADING CERTIFICATION 01/28/2026 APPROVED - AS NOTED FSLADISH
Note: 1/28/26 UPON WALKING PROPERTY DETERMINED EVEN THOUGH YOU ARE ONLY SHOWING 2 TENTHS BETWEEN THE LOWEST POINT IN THE MIDDLE REAR OF STRUCTURE AND THE REAR PROPERTY LINE, IN THE FIELD THE DRAINAGE WILL WORK. I AM APPROVING THIS INSPECTION AS NOTED. ______________________________________________________________________________________________________________________________ 1/21/2026 - PREVIOUS INSPECTION NOTES 01-21-26 TPOLACEK*** THE LOT GRADING CERT IS NOT ATTACHED TO THE MOST RECENT FINAL SURVEY. THE LGC MUST BE ATTACHED EACH TIME YOU UPLOAD A REVISED FINAL SURVEY. THE REAR YARD STILL DOES NOT MEET COPC MINIMUM STANDARDS. DRAIANGE IS REQUIRED TO FLOW TO THE FRONT ROAD GUTTER AS PER THE SITE PLAN. THE ELEVATION SHOT IN THE REAR OF 25.7 AND THE PROPERTY LINE SHOT OF 25.8 IS ONLY .10 OF FALL. THE MINIMUM REQUIRMEMT IS .30 Building Residential Final Survey Plan Reviews Technical Manual, Section 300.01 (D)(6) (V-!7) The top of the slope of “W” swales along the property lines shall be a minimum of 0.30 of a foot higher than the toe of the slope. (H)Technical Manual, Section 300.01 (D)(6) (V-!7) 1/12/2026 - PREVIOUS INSPECTION NOTES 01-12-26 TPOLACEK*** FINAL SURVEY DOES NOT MATCH PROPOSED SITE PLAN FOR DRAINAGE THERE MUST BE AN INSIDE SWALE CREATED AS SHOWN ON DRAINAGE PLAN
ROW FIELD SURVEY /GRADING CERTIFICATION 01/28/2026 APPROVED FSLADISH
Note: 1/28/26 AT THE TIME OF THIS INSPECTION DRAINGE WILL WORK. IT IS THE BUILDERS RESPONSIBILITY SHOULD CONDITIONS CHANGE AFTER THIS INSPECTION. _______________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9463 1/28/26 UPON WALKING PROPERTY DETERMINED EVEN THOUGH YOU ARE ONLY SHOWING 2 TENTHS BETWEEN THE LOWEST POINT IN THE MIDDLE REAR OF STRUCTURE AND THE REAR PROPERTY LINE, IN THE FIELD THE DRAINAGE WILL WORK. I AM APPROVING THIS INSPECTION AS NOTED. ______________________________________________________________________________________________________________________________ 1/21/2026 - PREVIOUS INSPECTION NOTES 01-21-26 TPOLACEK*** THE LOT GRADING CERT IS NOT ATTACHED TO THE MOST RECENT FINAL SURVEY. THE LGC MUST BE ATTACHED EACH TIME YOU UPLOAD A REVISED FINAL SURVEY. THE REAR YARD STILL DOES NOT MEET COPC MINIMUM STANDARDS. DRAIANGE IS REQUIRED TO FLOW TO THE FRONT ROAD GUTTER AS PER THE SITE PLAN. THE ELEVATION SHOT IN THE REAR OF 25.7 AND THE PROPERTY LINE SHOT OF 25.8 IS ONLY .10 OF FALL. THE MINIMUM REQUIRMEMT IS .30 Building Residential Final Survey Plan Reviews Technical Manual, Section 300.01 (D)(6) (V-!7) The top of the slope of “W” swales along the property lines shall be a minimum of 0.30 of a foot higher than the toe of the slope. (H)Technical Manual, Section 300.01 (D)(6) (V-!7) 1/12/2026 - PREVIOUS INSPECTION NOTES 01-12-26 TPOLACEK*** FINAL SURVEY DOES NOT MATCH PROPOSED SITE PLAN FOR DRAINAGE THERE MUST BE AN INSIDE SWALE CREATED AS SHOWN ON DRAINAGE PLAN
ROW- FINAL SURVEY/GRADING CERTIFICATION 01/21/2026 Disapproved -FEE REQUIRED TPOLACEK
Note: 01-21-26 TPOLACEK*** THE LOT GRADING CERT IS NOT ATTACHED TO THE MOST RECENT FINAL SURVEY. THE LGC MUST BE ATTACHED EACH TIME YOU UPLOAD A REVISED FINAL SURVEY. THE REAR YARD STILL DOES NOT MEET COPC MINIMUM STANDARDS. DRAIANGE IS REQUIRED TO FLOW TO THE FRONT ROAD GUTTER AS PER THE SITE PLAN. THE ELEVATION SHOT IN THE REAR OF 25.7 AND THE PROPERTY LINE SHOT OF 25.8 IS ONLY .10 OF FALL. THE MINIMUM REQUIRMEMT IS .30 Building Residential Final Survey Plan Reviews Technical Manual, Section 300.01 (D)(6) (V-!7) The top of the slope of “W” swales along the property lines shall be a minimum of 0.30 of a foot higher than the toe of the slope. (H)Technical Manual, Section 300.01 (D)(6) (V-!7) 1/12/2026 - PREVIOUS INSPECTION NOTES 01-12-26 TPOLACEK*** FINAL SURVEY DOES NOT MATCH PROPOSED SITE PLAN FOR DRAINAGE THERE MUST BE AN INSIDE SWALE CREATED AS SHOWN ON DRAINAGE PLAN
ROW- FINAL SURVEY/GRADING CERTIFICATION 01/12/2026 Disapproved - NO FEE TPOLACEK
Note: 01-12-26 TPOLACEK*** FINAL SURVEY DOES NOT MATCH PROPOSED SITE PLAN FOR DRAINAGE THERE MUST BE AN INSIDE SWALE CREATED AS SHOWN ON DRAINAGE PLAN
BLD - BUILDING FINAL 12/26/2025 FINAL APPROVED BTAYLOR
Note: 12/17/2025 - PREVIOUS INSPECTION NOTES 12/17/25 1. Missing weather stripping on bottom of garage entry door to house
BLD - BUILDING FINAL 12/17/2025 Disapproved - NO FEE MCONTRYMAN
Note: 12/17/25 1. Missing weather stripping on bottom of garage entry door to house
ELECTRIC - EARLY POWER 12/02/2025 APPROVED MCONTRYMAN
Note: Inspector Notes from Inspection 2200 10/22/25 Email sent to FPL
ROW- PRE-APRON (PRE-POUR) 11/17/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. . TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, IN THE UPCOMING MONTHS THE DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS WILL BE REQUIRED TO BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. YOU WILL RECEIVE A NEWS BLAST WHEN THIS BECOMES NECESSARY.
INSULATION 11/04/2025 APPROVED BTAYLOR
Note: 11/3/2025 - PREVIOUS INSPECTION NOTES 11-3-25 1. Several holes through out house need to be foamed. 2. Missing stud in middle room closet.
INSULATION 11/03/2025 Disapproved - NO FEE BTAYLOR
Note: 11-3-25 1. Several holes through out house need to be foamed. 2. Missing stud in middle room closet.
LATH/BRICK/ WATER BARRIER 10/31/2025 APPROVED CVANSTRAHLEN
ALL ROUGH 10/30/2025 APPROVED BTAYLOR
ROOF VALLEY & METAL 10/27/2025 APPROVED MCONTRYMAN
ELECTRIC-TUG 10/22/2025 APPROVED - AS NOTED MCONTRYMAN
Note: 10/22/25 Email sent to FPL
WALL SHEATHING 10/21/2025 APPROVED MCONTRYMAN
ROOF SHEATHING / BRACES/TIES/DOWN CELL 10/21/2025 APPROVED MCONTRYMAN
MONOLITHIC SLAB 10/09/2025 APPROVED MCONTRYMAN
PLUMBING 1ST ROUGH UNDERGROUND 10/09/2025 APPROVED - AS NOTED MGIBSON
Note: THIS WAS APPROVED ON 10/7/25
FORMBOARD SURVEY (OFFICE USE ONLY) 10/08/2025 APPROVED RRICKS
GRAVITY SEWER TEST 10/06/2025 APPROVED MGIBSON
SEWER TIE IN 10/06/2025 APPROVED MGIBSON

Review History

Department Status Date In Date Out
BADMIN INFORMATION 01/08/2026 01/08/2026
Note: Marked INFORMATION By: JAZMIN ROSARIO - - JROSARIO@PALMCOASTGOV.COM Rename files to match document type being uploaded.
SW1 COMPLETE 10/07/2025 10/08/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 10/07/2025 10/07/2025
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
SW1 HOLD 10/06/2025 10/06/2025
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM No revised formboard submitted for review.
BLD COMPLETE 10/06/2025 10/07/2025
Note: Released By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Submitted in error. cancelled review.
SW1 HOLD 10/03/2025 10/06/2025
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Formboard comments: Formboard dimensions on the right side of the home are off by 1'. Please revise. If marked the formboard survey showing dimension discrepancies.
ZON COMPLETE 10/03/2025 10/03/2025
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BADMIN INFORMATION 10/01/2025 10/01/2025
Note: Marked INFORMATION By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM label document correctly to match PDF file
SW1 COMPLETE 09/26/2025 09/26/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 09/23/2025 09/23/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
SW1 HOLD 09/23/2025 09/26/2025
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Repeat Grading Comment: The rear yard drainage swale's high point is higher than the back property line allowing water to flow to the rear of this property.
BLD COMPLETE 09/12/2025 09/18/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
CUSVC COMPLETE 09/12/2025 09/22/2025
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 09/12/2025 09/15/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 09/12/2025 09/15/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS CANCEL 09/12/2025 09/15/2025
LOCATE COMPLETE 09/12/2025 09/19/2025
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 09/12/2025 09/15/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 HOLD 09/12/2025 09/16/2025
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Grading comments: Based on the proposed elevations in the rear of this lot, stormwater is flowing to the rear of this lot in the middle. Please revise.
ZON HOLD 09/12/2025 09/15/2025
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Horizontal trim band by garage must wrap corners at least two feet
URB COMPLETE 09/12/2025 09/17/2025
Note: Released By: JOHN BEAUDET - (386)986-2456 - JBEAUDET@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
RSI REINSPECTION 1 ¤35.00 02/05/2026
SURCHARGE FS 533.721 ¤8.94 09/26/2025
SURCHARGE - FS 468.631 ¤13.42 09/26/2025
SW ENG - FOUNDATION SURVEY ¤20.00 09/26/2025
SW ENG INSPECTION 80 ¤80.00 09/26/2025
SW ENG PRE APRON ¤30.00 09/26/2025
SW ENG - REVIEW 20 ¤20.00 09/26/2025
WASTEWATER PERM INSPECTION ¤80.00 09/26/2025
WASTEWATER PERM REVIEW ¤25.00 09/26/2025
SEWER CAPITAL FACILITY ¤3,725.75 09/26/2025
WATER CAPITAL FACILITY FEE ¤3,149.89 09/26/2025
WATER PERMIT REVIEW ¤25.00 09/26/2025
SITE PLAN 30 ¤30.00 09/26/2025
WATER-METER ¤874.47 09/26/2025
WATER- TURN ON ¤50.00 09/26/2025
ADJUSTMENT 10% (¤99.37) 09/26/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 09/26/2025
INSPECTION - RESIDENTIAL ¤750.75 09/26/2025
PLAN REVIEW - RESIDENTIAL ¤212.94 09/26/2025
FC IMPACT FEE EMS ¤62.00 09/26/2025
IMPACT FEE FIRE ¤434.51 09/26/2025
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 09/26/2025
FC IMPACT FEE LIBRARY ¤268.00 09/26/2025
IMPACT FEE PARKS ¤1,828.01 09/26/2025
IMPACT FEE SCHOOL ¤5,450.00 09/26/2025
IMPACT FEE TRANSPORTATION ¤3,502.00 09/26/2025
WATER METER W/OUT TAP ¤965.03 09/26/2025
RECLAIM WATER PERMIT INSPECTIO ¤40.00 09/26/2025
Fees Total Due: ¤0.00 Total Paid: ¤21,829.34