I want to search for...

Permit #2025090840

Permit Details

Status: INSPECT

Parcel Id: 03-12-31-1125-00000-1690
CONDITIONED SPACE: 1842 sqft
GARAGE: 384 sqft
OPENED PORCH (WITH ROOF) : 32 sqft
OPENED PORCH (WITH ROOF) : 120 sqft
Total Square Footage: 2378 sqft
Subdivision: 2112 - COLBERT LANDINGS PH 1
Job Phone: 317-488-7593
Location Address: 34 GARNI DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 04/27/2026
NOC: RECORDED
Applicant name: STEVEN THOMAS HARDING
Owner: MERITAGE HOMES OF FLORIDA INC

Address

13901 SUTTON PARK DR S

JACKSONVILLE, FL 32224

Address

SUITE C350

JACKSONVILLE, FL 32224

Lot: 169
Contracted Stated Job Value: ¤160,372.00
Job Description: Single Family Residence
Type: CN

Contractor

MERITAGE HOMES OF FLORIDA INC
Status Location Address Mailing Address State License Number Phone
ACTIVE

13901 SUTTON PARK DR

JACKSONVILLE, FL 32224

SUITE C350

JACKSONVILLE, FL 32224

CBC1264443 (Exp: 08/31/2026) 317-488-7593

Sub Contractors

JAMES M GREENSLADE
Status Location Address State License Number Phone Fax
ACTIVE

311 S BAY ST

BUNNELL, FL 32110

EC13006083 (Exp: 08/31/2026) 386-263-2960 386-263-2980
DUSTIN L ESTEP
Status Location Address State License Number Phone Fax
ACTIVE

2041 N HIAWASSEE RD

APOPKA, FL 32703

CCC1330971 (Exp: 08/31/2026) 407-702-0206 352-988-6629
BENJAMIN MICHAEL RAY
Status Location Address Mailing Address State License Number Phone Fax
ACTIVE

6310 MABLETON PKWY

JACKSONVILLE, FL 32216

SUITE 1000

MABLETON, GA 30126

CFC1428415 (Exp: 08/31/2026) 904-861-5421 904-861-5426
STEVEN THOMAS HARDING
Status Location Address Mailing Address State License Number Phone
ACTIVE

13901 SUTTON PARK DR

JACKSONVILLE, FL 32224

SUITE C350

JACKSONVILLE, FL 32224

CBC1264443 (Exp: 08/31/2026) 317-488-7593
COREY MICHAEL TENNANT
Status Location Address State License Number Phone
ACTIVE

3370 AGRICULTURAL CNETER DR

ST AUGUSTINE, FL 32092

CAC1819063 (Exp: 08/31/2026) 904-829-8898

Inspection History

Type Request Date Result Inspector
GRAVITY SEWER TEST 06/12/2026 APPROVED CVANSTRAHLEN
SEWER TIE IN 06/12/2026 APPROVED CVANSTRAHLEN
ROOF VALLEY & METAL 06/09/2026 APPROVED CVANSTRAHLEN
WALL SHEATHING 06/05/2026 APPROVED CVANSTRAHLEN
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/05/2026 APPROVED CVANSTRAHLEN
WATER METER INSTALLATION REQUEST 06/02/2026 APPROVED ISANDERSON
MONOLITHIC SLAB 06/02/2026 CANCELLED BY APPLICANT WEB
MONOLITHIC SLAB 05/29/2026 APPROVED CVANSTRAHLEN
Note: 5/28/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1-FBC-R404.1.3.3.7.4-This provision mandates that when a concrete footing is poured, the steel reinforcement (rebar) must maintain a minimum clear distance of (3 ext{ inches}) between the rebar itself and the dirt (ground) below it. The concrete is required to completely surround and encapsulate the steel to protect it from soil moisture, preventing the rebar from rusting and keeping the foundation structurally ( please walk around and make sure is 3" space on all footers ) #2-footers call for 1'8" deep min , only 1'7" at the moment of the inspection footers not per plans #3-2020 NEC 250.52(3)-MISSING UFER GROUND - CONCRETE ENCASED ELECTRODE ARE ( removed 5' of underlayment Poly plastic under ufer for contact with soil
MONOLITHIC SLAB 05/28/2026 Disapproved - NO FEE CVANSTRAHLEN
Note: Please fix items before next inspection #1-FBC-R404.1.3.3.7.4-This provision mandates that when a concrete footing is poured, the steel reinforcement (rebar) must maintain a minimum clear distance of (3 ext{ inches}) between the rebar itself and the dirt (ground) below it. The concrete is required to completely surround and encapsulate the steel to protect it from soil moisture, preventing the rebar from rusting and keeping the foundation structurally ( please walk around and make sure is 3" space on all footers ) #2-footers call for 1'8" deep min , only 1'7" at the moment of the inspection footers not per plans #3-2020 NEC 250.52(3)-MISSING UFER GROUND - CONCRETE ENCASED ELECTRODE ARE ( removed 5' of underlayment Poly plastic under ufer for contact with soil
PLUMBING 1ST ROUGH UNDERGROUND 05/27/2026 APPROVED CVANSTRAHLEN
FORMBOARD SURVEY (OFFICE USE ONLY) 05/22/2026 APPROVED RRICKS
ELECTRIC - EARLY POWER
LATH/BRICK/ WATER BARRIER
ALL ROUGH
U-CROSS CONNECTION
ROW- PRE-APRON (PRE-POUR)
ROW - FINAL APRON (AFTER POUR)
ROW- FINAL SURVEY/GRADING CERTIFICATION
ROW - FINAL INSPECTION
U -UTILITY RESIDENTIAL FINAL
INSULATION
BLD - BUILDING FINAL

Review History

Department Status Date In Date Out
BLD COMPLETE 05/21/2026 05/26/2026
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
SW1 COMPLETE 05/15/2026 05/15/2026
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 05/15/2026 05/15/2026
Note: Released By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM
ZON COMPLETE 04/20/2026 04/21/2026
Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM
ZON HOLD 03/23/2026 03/23/2026
Note: Held By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM House does not meet the 15' street setback on the Left side.
SW1 COMPLETE 03/23/2026 03/26/2026
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ENGIN1 COMPLETE 03/23/2026 03/24/2026
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
SW1 HOLD 02/05/2026 02/05/2026
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM My apologies, disregard previous comments. Proposed elevations along 168, 169, and 170 will need to match master plan from the 15.26' to the 13.90'. Please feel free to call or email if there are any questions or concerns. I've attached approved master plan and discussed what needed to be done with Cody.
SW1 COMPLETE 01/23/2026 01/23/2026
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM After further review and submission of lot 170 (73 Ararat), the proposed elevations agree. Approved as noted.
BLD COMPLETE 09/22/2025 09/26/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
CUSVC COMPLETE 09/22/2025 10/02/2025
Note: Released By: CYNTHIA SCHWEERS - - CSCHWEERS@PALMCOASSTGOV.COM
ELEC COMPLETE 09/22/2025 09/26/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 09/22/2025 09/22/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS CANCEL 09/22/2025 09/24/2025
LOCATE COMPLETE 09/22/2025 09/26/2025
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 09/22/2025 09/24/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 HOLD 09/22/2025 09/26/2025
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Grading Comments: - Proposed grade along the back of the property does not match approved master plan. - Please provide existing elevations on a 20' grid, this shall include road center line, edge of pavement, lot lines, and 10' shots beyond property line. Please feel free to call or email if there are any questions or concerns.
ZON HOLD 09/22/2025 09/23/2025
Note: Held By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM 1. WALKWAY WIDTH MISSING SITE PLAN 2. LANDSCAPING MISSING ADDITIONAL PLANTINGS ON STREET SIDE

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
WATER-METER ¤965.03 05/12/2026
WATER- TURN ON ¤50.00 05/12/2026
WATER PERMIT INSPECTION ¤40.00 05/12/2026
WATER PERMIT REVIEW ¤25.00 04/27/2026
SITE PLAN 30 ¤30.00 04/27/2026
WATER- TURN ON ¤50.00 04/27/2026
ADJUSTMENT 10% (¤121.43) 04/27/2026
ADMINISTRATIVE RESIDENTIAL ¤30.00 04/27/2026
INSPECTION - RESIDENTIAL ¤946.00 04/27/2026
PLAN REVIEW - RESIDENTIAL ¤268.32 04/27/2026
CONTRACTOR CHANGE ¤20.00 04/27/2026
FC IMPACT FEE EMS ¤62.00 04/27/2026
IMPACT FEE FIRE ¤434.51 04/27/2026
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 04/27/2026
FC IMPACT FEE LIBRARY ¤268.00 04/27/2026
IMPACT FEE PARKS ¤1,828.01 04/27/2026
IMPACT FEE TRANSPORTATION ¤3,502.00 04/27/2026
WATER METER W/OUT TAP ¤965.03 04/27/2026
SURCHARGE FS 533.721 ¤11.23 04/27/2026
SURCHARGE - FS 468.631 ¤16.84 04/27/2026
SW ENG - FOUNDATION SURVEY ¤20.00 04/27/2026
SW ENG INSPECTION 80 ¤80.00 04/27/2026
SW ENG PRE APRON ¤30.00 04/27/2026
SW ENG - REVIEW 20 ¤20.00 04/27/2026
WASTEWATER PERM INSPECTION ¤80.00 04/27/2026
WASTEWATER PERM REVIEW ¤25.00 04/27/2026
SEWER CAPITAL FACILITY ¤3,613.92 04/27/2026
WATER CAPITAL FACILITY FEE ¤3,039.48 04/27/2026
Fees Total Due: ¤0.00 Total Paid: ¤16,516.94