I want to search for...

Permit #2025091028

Permit Details

Status: COED

Parcel Id: 07-11-31-7028-00020-0050
Block: 00020
Subdivision: 7028 -
Job Phone: 407-476-6212
Location Address: 9 PHILOX LN
Type: SLRE - SOLAR ELECTRIC - PHOTOVOLTAIC
Issue Date: 10/23/2025
NOC: RECORDED
Applicant name: FREDERICK C BRAUN
Owner: HOLMAN JERRY LEE JR & STEPHANIE RENEE H&W

Address

9 PHILOX LN

PALM COAST, FL 32164

Lot: 0050
Contracted Stated Job Value: ¤44,230.80
Job Description: PV SOLAR PANEL INSTALLATION ROOF MOUNTED
Type: CN

Contractor

PJWD ENERGY LLC
Status Location Address State License Number Phone
ACTIVE

6752 CURTIS STREET

ORLANDO, FL 32807

EC13012687 (Exp: 08/31/2026) 407-476-6212

Inspection History

Type Request Date Result Inspector
SOLAR ELECTRIC FINAL 12/19/2025 FINAL APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 12/19/2025 2:57:43 PM *** 11/14/2025 - PREVIOUS INSPECTION NOTES 11/14/25: ATTEMPTED COMMUNICATION WITH CONTRACTOR MULTIPLE TIMES/WAYS. 1). Original TUG outlet (outlet below Main Panel noted previously) has now been removed by Solar contractor leaving an opening in the stucco. Outlet will need to be re-installed in original spot and in accordance with code requirements (will also need to be fully sealed around the perimeter of the outlet box). or stucco will need to be repaired to make water tight where outlet was removed. 11/12/2025 - PREVIOUS INSPECTION NOTES 11/12/25: PREVIOSLY LISTED ITEMS 1 AND 2 REMIAN UNRESOLVED. PREVIOUSLY LISTED ITEM 3 DOES NOT MEET CODE REQUIREMENTS. 1). Missing labels as required on plans. Marked on plans. FBC [A]107.4 >> STILL MISSING LABELS. SEE PLANS. 2). Breaker for GFCI has been moved so the new spot will need to be identified correctly as required. NEC 408.4 (A) >> BREAKER FOR TUG OUTLET BELOW PANEL HAS BEEN REMOVED AND A BLANK PUT IN ITS PLACE. RE-INSTALL BREAKER AND LABEL COPRRECTLY AS REQUIRED. 3). Surge protector is required at main panel. NEC-230.67(A)/(B) >> SURGE PROTECTOR NEEDS TO BE DIRECTLY AFTER THE MAIN BREAKER ON THE BUSS BAR. ALSO, NEEDS TO BE IDENTIFIED AS REQUIRED. NEC 408.4 (A) 11/6/2025 - PREVIOUS INSPECTION NOTES 11/6/25: A Virtual inspection will be available IF requested at the time of scheduling the re-inspection. If requesting a Virtual Re-inspection, please schedule the re-inspection for the same day that the deficiencies will be corrected and a FaceTime or Google Meet live virtual inspection can be completed. (Pictures are not approved). >>>>>> 1). Missing labels as required on plans. Marked on plans. FBC [A]107.4 2). Breaker for GFCI has been moved so the new spot will need to be identified correctly as required. NEC 408.4 (A) 3). Surge protector is required at main panel. NEC-230.67(A)/(B) _______________________________________________________________________________________________________________________ 11/4/2025 - PREVIOUS INSPECTION NOTES 11/4/25: No answer at the door after ringing video doorbell and knocking loudly twice. Dogs barking. Waited 5+ minutes. 1). Need access for inspection. FBC[A] 110.5
SOLAR ELECTRIC FINAL 11/14/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 11/14/2025 2:10:09 PM *** 11/14/25: ATTEMPTED COMMUNICATION WITH CONTRACTOR MULTIPLE TIMES/WAYS. 1). Original TUG outlet (outlet below Main Panel noted previously) has now been removed by Solar contractor leaving an opening in the stucco. Outlet will need to be re-installed in original spot and in accordance with code requirements (will also need to be fully sealed around the perimeter of the outlet box). or stucco will need to be repaired to make water tight where outlet was removed. 11/12/2025 - PREVIOUS INSPECTION NOTES 11/12/25: PREVIOSLY LISTED ITEMS 1 AND 2 REMIAN UNRESOLVED. PREVIOUSLY LISTED ITEM 3 DOES NOT MEET CODE REQUIREMENTS. 1). Missing labels as required on plans. Marked on plans. FBC [A]107.4 >> STILL MISSING LABELS. SEE PLANS. 2). Breaker for GFCI has been moved so the new spot will need to be identified correctly as required. NEC 408.4 (A) >> BREAKER FOR TUG OUTLET BELOW PANEL HAS BEEN REMOVED AND A BLANK PUT IN ITS PLACE. RE-INSTALL BREAKER AND LABEL COPRRECTLY AS REQUIRED. 3). Surge protector is required at main panel. NEC-230.67(A)/(B) >> SURGE PROTECTOR NEEDS TO BE DIRECTLY AFTER THE MAIN BREAKER ON THE BUSS BAR. ALSO, NEEDS TO BE IDENTIFIED AS REQUIRED. NEC 408.4 (A) 11/6/2025 - PREVIOUS INSPECTION NOTES 11/6/25: A Virtual inspection will be available IF requested at the time of scheduling the re-inspection. If requesting a Virtual Re-inspection, please schedule the re-inspection for the same day that the deficiencies will be corrected and a FaceTime or Google Meet live virtual inspection can be completed. (Pictures are not approved). >>>>>> 1). Missing labels as required on plans. Marked on plans. FBC [A]107.4 2). Breaker for GFCI has been moved so the new spot will need to be identified correctly as required. NEC 408.4 (A) 3). Surge protector is required at main panel. NEC-230.67(A)/(B) _______________________________________________________________________________________________________________________ 11/4/2025 - PREVIOUS INSPECTION NOTES 11/4/25: No answer at the door after ringing video doorbell and knocking loudly twice. Dogs barking. Waited 5+ minutes. 1). Need access for inspection. FBC[A] 110.5
SOLAR ELECTRIC FINAL 11/12/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 11/12/2025 2:00:42 PM *** 11/12/25: PREVIOSLY LISTED ITEMS 1 AND 2 REMIAN UNRESOLVED. PREVIOUSLY LISTED ITEM 3 DOES NOT MEET CODE REQUIREMENTS. 1). Missing labels as required on plans. Marked on plans. FBC [A]107.4 >> STILL MISSING LABELS. SEE PLANS. 2). Breaker for GFCI has been moved so the new spot will need to be identified correctly as required. NEC 408.4 (A) >> BREAKER FOR TUG OUTLET BELOW PANEL HAS BEEN REMOVED AND A BLANK PUT IN ITS PLACE. RE-INSTALL BREAKER AND LABEL COPRRECTLY AS REQUIRED. 3). Surge protector is required at main panel. NEC-230.67(A)/(B) >> SURGE PROTECTOR NEEDS TO BE DIRECTLY AFTER THE MAIN BREAKER ON THE BUSS BAR. ALSO, NEEDS TO BE IDENTIFIED AS REQUIRED. NEC 408.4 (A) 11/6/2025 - PREVIOUS INSPECTION NOTES 11/6/25: A Virtual inspection will be available IF requested at the time of scheduling the re-inspection. If requesting a Virtual Re-inspection, please schedule the re-inspection for the same day that the deficiencies will be corrected and a FaceTime or Google Meet live virtual inspection can be completed. (Pictures are not approved). >>>>>> 1). Missing labels as required on plans. Marked on plans. FBC [A]107.4 2). Breaker for GFCI has been moved so the new spot will need to be identified correctly as required. NEC 408.4 (A) 3). Surge protector is required at main panel. NEC-230.67(A)/(B) _______________________________________________________________________________________________________________________ 11/4/2025 - PREVIOUS INSPECTION NOTES 11/4/25: No answer at the door after ringing video doorbell and knocking loudly twice. Dogs barking. Waited 5+ minutes. 1). Need access for inspection. FBC[A] 110.5
SOLAR ELECTRIC FINAL 11/06/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 11/6/2025 10:00:27 AM *** 11/6/25: A Virtual inspection will be available IF requested at the time of scheduling the re-inspection. If requesting a Virtual Re-inspection, please schedule the re-inspection for the same day that the deficiencies will be corrected and a FaceTime or Google Meet live virtual inspection can be completed. (Pictures are not approved). >>>>>> 1). Missing labels as required on plans. Marked on plans. FBC [A]107.4 2). Breaker for GFCI has been moved so the new spot will need to be identified correctly as required. NEC 408.4 (A) 3). Surge protector is required at main panel. NEC-230.67(A)/(B) _______________________________________________________________________________________________________________________ 11/4/2025 - PREVIOUS INSPECTION NOTES 11/4/25: No answer at the door after ringing video doorbell and knocking loudly twice. Dogs barking. Waited 5+ minutes. 1). Need access for inspection. FBC[A] 110.5
SOLAR ELECTRIC FINAL 11/04/2025 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 11/4/2025 1:25:25 PM *** 11/4/25: No answer at the door after ringing video doorbell and knocking loudly twice. Dogs barking. Waited 5+ minutes. 1). Need access for inspection. FBC[A] 110.5

Review History

Department Status Date In Date Out
BLD COMPLETE 10/23/2025 10/23/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD HOLD 09/25/2025 09/25/2025
Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM Provide Engineer's structural calculations and certification letter for the adequte support of existing roof framing for the proposed solar panel loads as per FBCR 324.4, with digital signature of an engineer of record as per F.S. 471.025 and F.A.C. 61G15-23.001.
ELEC COMPLETE 09/25/2025 09/25/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 12/18/2025
REINSPECTION RESIDENTIAL ¤40.00 11/12/2025
REINSPECTION RESIDENTIAL ¤40.00 11/06/2025
SURCHARGE FS 533.721 ¤2.00 10/23/2025
SURCHARGE - FS 468.631 ¤2.95 10/23/2025
ADJUSTMENT 10% (¤21.88) 10/23/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 10/23/2025
INSPECTION - RESIDENTIAL ¤123.75 10/23/2025
SOLAR PLAN REVIEW ¤65.00 10/23/2025
Fees Total Due: ¤0.00 Total Paid: ¤321.82