I want to search for...

Permit #2025091057

Permit Details

Status: COED

Parcel Id: 03-12-31-1126-00000-2580
CONDITIONED SPACE: 2746 sqft
GARAGE: 600 sqft
OPENED PORCH (WITH ROOF) : 155 sqft
OPENED PORCH (WITH ROOF) : 384 sqft
Total Square Footage: 3885 sqft
Subdivision: 2344 - COLBERT LANDINGS PH 2
Job Phone: 813-917-1689
Location Address: 115 ARMOYAN DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 11/10/2025
NOC: RECORDED
Applicant name: SCOTT EVAN KEUNING
Owner: TAYLOR MORRISON OF FLORIDA INC

Address

1275 W GRANADA BLVD

ORMOND BEACH, FL 32174

Address

SUITE 3B

ORMOND BEACH, FL 32174

Lot: 258
Contracted Stated Job Value: ¤202,614.00
Job Description: SINGLE FAMILY HOME
Type: CN

Contractor

TAYLOR MORRISON OF FLORIDA INC
Status Location Address State License Number Phone
ACTIVE

7785 BAY MEADOWS WAY, SUITE 105

JACKSONVILLE, FL 32256

CBC1265083 (Exp: 08/31/2026) 813-917-1689

Sub Contractors

JOSEPH H STRADA JR
Status Location Address State License Number Phone
ACTIVE

3400 ST JOHNS PKWY

SANFORD, FL 32771

CAC043953 (Exp: 08/31/2026) 877-906-1113
JOSEPH HORATIO STRADA JR
Status Location Address State License Number Phone
ACTIVE

3400 ST JOHNS PARKWAY

SANFORD, FL 32771

EC13003715 (Exp: 08/31/2026) 877-906-1113
BENJAMIN MICHAEL RAY
Status Location Address Mailing Address State License Number Phone Fax
ACTIVE

6310 MABLETON PKWY

JACKSONVILLE, FL 32216

SUITE 1000

MABLETON, GA 30126

CFC1428415 (Exp: 08/31/2026) 904-861-5421 904-861-5426
CHASE RANDOLPH MASSEY
Status Location Address State License Number Phone
ACTIVE

10048 103RD ST

JACKSONVILLE, FL 32210

CCC1332486 (Exp: 08/31/2026) 904-248-1133

Inspection History

Type Request Date Result Inspector
ROW - FINAL INSPECTION 03/10/2026 APPROVED FSLADISH
Note: 3/10/26 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S AND/OR HOMEOWNER’S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. __________________________________________________________________________________________________________________________________ *** INSPECTORS NOTE. BUILDER REQUIRED TO INSTALL SILT FENCE PER COPC STANDARDS ON THE LEFT SIDE PROPERTY LINE BEFORE ROW FINAL PASSAGE. ***
U -UTILITY RESIDENTIAL FINAL 03/06/2026 FINAL APPROVED BWRIGHT
U-CROSS CONNECTION 03/06/2026 APPROVED BWRIGHT
ROW- FINAL SURVEY/GRADING CERTIFICATION 03/05/2026 APPROVED FSLADISH
Note: 3/4/2026 - PREVIOUS INSPECTION NOTES 3/4/26 YOU HAVE CHECKED BOTH BOXES UNDER ENGINEERING CERTIFICATION ON YOU LGADC WHERE IT STATES TO CHECK ONE. PLEASE MAKE CORRECTION BEFORE RESUBMITTING FOR REVIEW.
ROW FIELD SURVEY /GRADING CERTIFICATION 03/05/2026 APPROVED FSLADISH
Note: 3/4/26 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S AND/OR HOMEOWNER’S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ROW - FINAL APRON (AFTER POUR) 03/05/2026 APPROVED FSLADISH
Note: 3/4/26 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S AND/OR HOMEOWNER’S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW- FINAL SURVEY/GRADING CERTIFICATION 03/04/2026 Disapproved - NO FEE FSLADISH
Note: 3/4/26 YOU HAVE CHECKED BOTH BOXES UNDER ENGINEERING CERTIFICATION ON YOU LGADC WHERE IT STATES TO CHECK ONE. PLEASE MAKE CORRECTION BEFORE RESUBMITTING FOR REVIEW.
BLD - BUILDING FINAL 02/24/2026 FINAL APPROVED BTAYLOR
ELECTRIC - EARLY POWER 02/03/2026 APPROVED - AS NOTED BTAYLOR
Note: 2-3-26 1. Emailed FPL at 11:52. 1/30/2026 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2200 12-4-25 1. Emailed FPL at 10:29.
ELECTRIC - EARLY POWER 01/30/2026 CANCELLED BY APPLICANT BTAYLOR
Note: Inspector Notes from Inspection 2200 12-4-25 1. Emailed FPL at 10:29.
ROW- PRE-APRON (PRE-POUR) 01/16/2026 APPROVED - AS NOTED TPOLACEK
Note: 01-16-26 TPOLACEK** SPOKE WITH CM ON SITE AND THEY WILL HAVE APRON WINGS BROUGHT IN THE MATCH EDGE OF DRIVEWAY WITH 36" FLARE. APPROVING AS NOTED AT THE TIME OF THE INSPECTION READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. . TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, IN THE UPCOMING MONTHS THE DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS WILL BE REQUIRED TO BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. YOU WILL RECEIVE A NEWS BLAST WHEN THIS BECOMES NECESSARY. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 1/15/2026 - PREVIOUS INSPECTION NOTES 01-15-26 TPOLACEK*** POUR AREA DOES NOT HAVE 6" THROUGHOUT THE ENTIRE ROW POUR AREA. ROW IN SUBDIVISIONS IS 10' FROM CURB EDGE. APRON WINGS MUST BE IN LINE WITH EDGE OF DRIVEWAY
ROW- PRE-APRON (PRE-POUR) 01/15/2026 Disapproved -FEE REQUIRED TPOLACEK
Note: 01-15-26 TPOLACEK*** POUR AREA DOES NOT HAVE 6" THROUGHOUT THE ENTIRE ROW POUR AREA. ROW IN SUBDIVISIONS IS 10' FROM CURB EDGE. APRON WINGS MUST BE IN LINE WITH EDGE OF DRIVEWAY
GRAVITY SEWER TEST 01/08/2026 APPROVED BTAYLOR
SEWER TIE IN 01/08/2026 APPROVED BTAYLOR
INSULATION 12/26/2025 APPROVED BTAYLOR
Note: Inspector Notes from Inspection 2420 12-19-25 1. Need to post address. 2. No 5' head pressure. Check at insulation.
ALL ROUGH 12/19/2025 APPROVED - AS NOTED BTAYLOR
Note: 12-19-25 1. Need to post address. 2. No 5' head pressure. Check at insulation.
LATH/BRICK/ WATER BARRIER 12/12/2025 APPROVED BTAYLOR
Note: 12/9/2025 - PREVIOUS INSPECTION NOTES 12-9-25 1. Not ready.
ROOF VALLEY & METAL 12/09/2025 APPROVED BTAYLOR
LATH/BRICK/ WATER BARRIER 12/09/2025 Disapproved - NO FEE BTAYLOR
Note: 12-9-25 1. Not ready.
ELECTRIC-TUG 12/04/2025 APPROVED - AS NOTED BTAYLOR
Note: 12-4-25 1. Emailed FPL at 10:29.
WALL SHEATHING 12/04/2025 APPROVED BTAYLOR
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/04/2025 APPROVED BTAYLOR
MONOLITHIC SLAB 11/17/2025 APPROVED BTAYLOR
PLUMBING 1ST ROUGH UNDERGROUND 11/13/2025 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 11/13/2025 APPROVED CBOWERMASTER
FORMBOARD SURVEY (OFFICE USE ONLY) 11/12/2025 APPROVED RRICKS

Review History

Department Status Date In Date Out
BADMIN INFORMATION 02/20/2026 02/20/2026
Note: Marked INFORMATION By: KATIE TAING - (386)986-3751 - KTAING@PALMCOASTGOV.COM Wrong address submitted for Blower Door Test.
SW1 COMPLETE 11/12/2025 11/12/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 11/12/2025 11/12/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD COMPLETE 11/06/2025 11/06/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ZON COMPLETE 10/30/2025 10/30/2025
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ZON HOLD 10/29/2025 10/29/2025
Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM REPEAT COMMENT: HOUSE LAYOUT DIFFERENT ON LANDSCAPE PLAN (LANAI) - THE LANDSCAPE PLAN NEEDS TO BE CORRECTED TO REFLECT THE LANAI EXTENDING ALONG THE ENTIRE REAR OF THE HOME AS PER THE SITE PLAN AND ENGINEERED DRAWINGS.
SW1 COMPLETE 10/29/2025 10/29/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
BLD HOLD 10/29/2025 10/31/2025
Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM Product Approval FL# 15516.1 not valid 2nd Request
ENGIN1 COMPLETE 10/29/2025 10/29/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
BLD HOLD 09/30/2025 09/30/2025
Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM PREVIOUS REVIEW COMPLETED IN ERROR. THIS IS CORRECT REVIEW. Product Approval FL# 15516.1 not valid
BLD COMPLETE 09/25/2025 09/30/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
CUSVC COMPLETE 09/25/2025 10/06/2025
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 09/25/2025 09/29/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 09/25/2025 09/29/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS CANCEL 09/25/2025 09/26/2025
LOCATE COMPLETE 09/25/2025 09/30/2025
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 09/25/2025 09/26/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 HOLD 09/25/2025 09/29/2025
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Grading Comments: - Please depict what the natural grade elevation is in the back of the property. - Please provide existing grades on a 20' grid with 10' shots beyond lot lines. This shall also include elevations along lot lines, road center line and edge of pavement.
ZON HOLD 09/25/2025 09/25/2025
Note: Held By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM HOUSE LAYOUT ON LANDSCAPE PLAN DOES NOT MATCH (LANAI)
URB COMPLETE 09/25/2025 09/30/2025
Note: Released By: JOHN BEAUDET - (386)986-2456 - JBEAUDET@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
RSI REINSPECTION 1 ¤35.00 03/10/2026
SURCHARGE FS 533.721 ¤17.24 11/10/2025
SURCHARGE - FS 468.631 ¤25.85 11/10/2025
SW ENG - FOUNDATION SURVEY ¤20.00 11/10/2025
SW ENG INSPECTION 80 ¤80.00 11/10/2025
SW ENG PRE APRON ¤30.00 11/10/2025
SW ENG - REVIEW 20 ¤20.00 11/10/2025
WASTEWATER PERM INSPECTION ¤80.00 11/10/2025
WASTEWATER PERM REVIEW ¤25.00 11/10/2025
SEWER CAPITAL FACILITY ¤3,613.92 11/10/2025
WATER CAPITAL FACILITY FEE ¤3,039.48 11/10/2025
WATER PERMIT INSPECTION ¤40.00 11/10/2025
WATER PERMIT REVIEW ¤25.00 11/10/2025
SITE PLAN 30 ¤30.00 11/10/2025
WATER-METER ¤965.03 11/10/2025
WATER- TURN ON ¤50.00 11/10/2025
WATER- TURN ON ¤50.00 11/10/2025
ADJUSTMENT 10% (¤191.50) 11/10/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 11/10/2025
INSPECTION - RESIDENTIAL ¤1,468.50 11/10/2025
PLAN REVIEW - RESIDENTIAL ¤416.52 11/10/2025
FC IMPACT FEE EMS ¤62.00 11/10/2025
IMPACT FEE FIRE ¤434.51 11/10/2025
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 11/10/2025
FC IMPACT FEE LIBRARY ¤268.00 11/10/2025
IMPACT FEE PARKS ¤1,828.01 11/10/2025
IMPACT FEE TRANSPORTATION ¤3,502.00 11/10/2025
WATER METER W/OUT TAP ¤965.03 11/10/2025
Fees Total Due: ¤0.00 Total Paid: ¤17,147.59