I want to search for...
Permit #2025091217
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7025-00440-0190 |
| Block: 00440 |
| Subdivision: 7025 - |
| Job Phone: 386-795-9854 |
| Location Address: 96 PUTTER DR |
| Type: ME - MECHANICAL |
| Issue Date: 10/10/2025 |
| NOC: Unknown |
| Applicant name: DAVID JOSHUA COX |
| Owner: MOORE PATRICK JOSEPH & TAMMI LEE MOORE H&W |
|
Address 96 PUTTER DRIVE PALM COAST, FL 32164 |
| Lot: 0190 |
| Contracted Stated Job Value: ¤11,773.00 |
| Job Description: DUCTWORK ONLY C/O ( 3.5 TON ) |
| Type: CN |
Contractor
ONE HOUR AIR CONDITIONING & HEATING
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3000 S. RIDGEWOOD AVE # B SOUTH DAYTONA, FL 32119 |
CAC1817215 (Exp: 08/31/2026) | 386-262-1247 |
Inspection History
| Type | Request Date | Result | Inspector |
| HVAC FINAL | 02/13/2026 | FINAL APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 2/13/2026 1:32:26 PM *** 11/17/2025 - PREVIOUS INSPECTION NOTES 11/17/25: NOT READY!!!! AHU UNIT WAS RELOCATED FROM THE BACK LEFT CORNER OF THE GARAGE TO THE BACK WALL OF THE GARAGE IN THE MIDDLE. 1). Original Electrical feed is missing sheathing in attic space. Requires junction box properly mounted for this wire. New wire needs to be replaced so that it is complete to the junction box. NEC-300.15(A). 2). Previous holes in garage ceiling and walls need to be repaired and finished with the approved material as required. FBC-R302.11(4). / FBC-R302.6 3). Hole in garage ceiling for new lineset needs to be sealed with approved material as required. FBC-R302.11(4). 4). Original sleeve (in garage slab) for lineset/condensate drain needs to be sealed as required. FBC-P2603.3.1 5). Original lineset & condensate piping needs to be sealed shut and/or capped on both ends as required. FBC-[A] 107.4 6). All register (and return) boots need to be replaced (along with supply registers & return grills) as all are missing the seals as required. FBC EC TABLE R402.4.1.1 7). Exterior sleeve for lineset/wiring, etc. needs to be fully sealed at the bottom and top with approved material. FBC-G2404.9 (301.14) | |||
| HVAC ROUGH | 11/17/2025 | CANCELLED BY INSPECTOR | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 11/17/2025 12:26:14 PM *** 11/17/25: This inspection is not required for this permit and the work performed. | |||
| HVAC FINAL | 11/17/2025 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 11/17/2025 1:10:55 PM *** 11/17/25: NOT READY!!!! AHU UNIT WAS RELOCATED FROM THE BACK LEFT CORNER OF THE GARAGE TO THE BACK WALL OF THE GARAGE IN THE MIDDLE. 1). Original Electrical feed is missing sheathing in attic space. Requires junction box properly mounted for this wire. New wire needs to be replaced so that it is complete to the junction box. NEC-300.15(A). 2). Previous holes in garage ceiling and walls need to be repaired and finished with the approved material as required. FBC-R302.11(4). / FBC-R302.6 3). Hole in garage ceiling for new lineset needs to be sealed with approved material as required. FBC-R302.11(4). 4). Original sleeve (in garage slab) for lineset/condensate drain needs to be sealed as required. FBC-P2603.3.1 5). Original lineset & condensate piping needs to be sealed shut and/or capped on both ends as required. FBC-[A] 107.4 6). All register (and return) boots need to be replaced (along with supply registers & return grills) as all are missing the seals as required. FBC EC TABLE R402.4.1.1 7). Exterior sleeve for lineset/wiring, etc. needs to be fully sealed at the bottom and top with approved material. FBC-G2404.9 (301.14) |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 10/09/2025 | 10/10/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | HOLD | 10/08/2025 | 10/08/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide a duct layout |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 02/11/2026 |
| SURCHARGE FS 533.721 | ¤2.00 | 10/10/2025 |
| SURCHARGE - FS 468.631 | ¤2.00 | 10/10/2025 |
| ADJUSTMENT 10% | (¤9.00) | 10/10/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 10/10/2025 |
| INSPECTION - MECHANICAL | ¤60.00 | 10/10/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤125.00 |