I want to search for...

Permit #2025091292

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7032-00670-0070
Block: 00670
Subdivision: 7032 -
Job Phone: 386-944-0848
Location Address: 24 ROXTON LN
Type: GA - GAS
Issue Date: 12/12/2025
NOC: Unknown
Applicant name: DANIEL J FERRARA
Owner: HERBERT ROBERT W JR

Address

24 ROXTON LANE

PALM COAST, FL 32164

Lot: 0070
Contracted Stated Job Value: ¤1,295.00
Job Description: 100LB A/G LP TANK AND GAS LINE TO RANGE
Type: CN

Contractor

TOTAL COMFORT GAS INC
Status Location Address State License Number Phone
ACTIVE

400 N US 1

ORMOND BEACH, FL 32174

LQ34256 (Exp: 08/28/2027) 386-944-0848

Inspection History

Type Request Date Result Inspector
GAS ROUGH 01/15/2026 APPROVED CVANSTRAHLEN
Note: contractor was on side , install gauge and safe all gas pipes Buiding inspector chief building inspector was on side 1/14/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection Items front previous inspection not fix #1-gauge reading 0 PSI #2- gas line on attic space have not support or straps #3- Appliances on house still connected to the gas line 9 NEED TO BE REMOVED TO VERIFID SUPPORT ON PIPE GAS LINE 12/15/2025 - PREVIOUS INSPECTION NOTES 12/15/25: Inspection was not completed at the time frame that is required by code which is prior to concealing pipework or installation of appliance, etc. 1). Requires gauge testing of pipe work prior to final connection. Gauge installed on side port of gas valve is only reading 10 psi. (15 psi minimum required). Associated codes added: FBCR G2417.4.1 / FBC-[A] 110.1
GAS FINAL 01/15/2026 APPROVED CVANSTRAHLEN
Note: 12/15/2025 - PREVIOUS INSPECTION NOTES 12/15/25: Gas Rough needs to be completed prior to this inspection.
GAS ROUGH 01/14/2026 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: Please fix items before next inspection Items front previous inspection not fix #1-gauge reading 0 PSI #2- gas line on attic space have not support or straps #3- Appliances on house still connected to the gas line 9 NEED TO BE REMOVED TO VERIFID SUPPORT ON PIPE GAS LINE 12/15/2025 - PREVIOUS INSPECTION NOTES 12/15/25: Inspection was not completed at the time frame that is required by code which is prior to concealing pipework or installation of appliance, etc. 1). Requires gauge testing of pipe work prior to final connection. Gauge installed on side port of gas valve is only reading 10 psi. (15 psi minimum required). Associated codes added: FBCR G2417.4.1 / FBC-[A] 110.1
GAS ROUGH 12/15/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 12/15/2025 1:06:43 PM *** Associated codes added: FBCR G2417.4.1 / FBC-[A] 110.1 *** NOTES ADDED BY RSIMS 12/15/2025 1:03:32 PM *** 12/15/25: Inspection was not completed at the time frame that is required by code which is prior to concealing pipework or installation of appliance, etc. 1). Requires gauge testing of pipe work prior to final connection. Gauge installed on side port of gas valve is only reading 10 psi. (15 psi minimum required).
GAS FINAL 12/15/2025 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 12/15/2025 1:08:23 PM *** 12/15/25: Gas Rough needs to be completed prior to this inspection.

Review History

Department Status Date In Date Out
GAS COMPLETE 09/30/2025 10/01/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ZON COMPLETE 09/30/2025 10/01/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADJUSTMENT 10% (¤12.25) 12/12/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 12/12/2025
INSPECTION - RESIDENTIAL ¤60.00 12/12/2025
PLAN REVIEW - MISC 32.50 ¤32.50 12/12/2025
SURCHARGE FS 533.721 ¤2.00 12/12/2025
SURCHARGE - FS 468.631 ¤2.00 12/12/2025
SITE PLAN 15 ¤15.00 12/12/2025
Fees Total Due: ¤0.00 Total Paid: ¤129.25