Permit #2025100100

Permit Details

Status: COED

Parcel Id: 07-11-31-7035-00030-0070
GARAGE: 427 sqft
CONDITIONED SPACE: 1609 sqft
OPENED PORCH (WITH ROOF) : 21 sqft
OPENED PORCH (WITH ROOF) : 36 sqft
Total Square Footage: 2093 sqft
Block: 00030
Subdivision: -
Job Phone: 407-476-8195
Location Address: 12 BURNING TREE PL
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 11/05/2025
NOC: RECORDED
Applicant name: CARLETTE RENE WITTE
Owner: INNOVATIVE NATIONWIDE BUILDERS INC

Address

3670 MAGUIRE BLVD

ORLANDO, FL 32803

Address

220

ORLANDO, FL 32803

Lot: 0070
Contracted Stated Job Value: ¤175,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

INNOVATIVE NATIONWIDE BUILDERS INC
Status Location Address State License Number Phone
ACTIVE

3670 MAGUIRE BLVD #220

,

CRC1330026 (Exp: 08/31/2026) 855-694-6634

Sub Contractors

HEATH EDWARD SANFORD
Status Location Address State License Number Phone
ACTIVE

126 EAST END RD

SAN MATEO, FL 32187

CFC1429896 (Exp: 08/31/2026) 386-871-8823
TERRY BRICE DICKERSON
Status Location Address State License Number Phone
ACTIVE

4300 ST JOHN'S PARKWAY

ALPHARETTA, GA 30009

CCC1326209 (Exp: 08/31/2026) 407-548-6733
JASON LEE JAMES
Status Location Address State License Number Phone
ACTIVE

217 N WESTMONTE DR SUITE 1007

ALTAMONTE SPRINGS, FL 32714

CAC1820196 (Exp: 08/31/2026) 407-404-4000
ANTHONY OKEITH FENNELL
Status Location Address State License Number Phone
ACTIVE

217 N. WESTMONTE DR, SUITE 1007

ALTAMONTE SPRINGS, FL 32714

EC13011194 (Exp: 08/31/2026) 407-404-4000

Inspection History

Type Request Date Result Inspector
U-CROSS CONNECTION 06/05/2026 APPROVED - AS NOTED TLOWE
Note: NO CC / NO IRR
BLD - BUILDING FINAL 06/02/2026 FINAL APPROVED JSTEWART
Note: 5/28/2026 - PREVIOUS INSPECTION NOTES 1. Tug receptacle reuires WR. NEC 406.9 2. Please seal Ufer ground view outlet (cover). FBC EC TABLE R402.4.1.1 3. Please raise AC Pad min 3" above surrounding ground. FBCR M1305.1.4.1 4. No Hot water at fixtures. FBCR P2705.1 – 4 5. Please seal wall penetration at AHU Power. R302.11(4) 6. Please seal garage ceiling at cat5. FBC R302.5.3 7. Please seal garage wall at HW power. FBC R302.5.3 8. Please install weather strip at Garage to House door. FBC R302.5.1
BLD - BUILDING FINAL 05/28/2026 Disapproved - NO FEE JSTEWART
Note: 1. Tug receptacle reuires WR. NEC 406.9 2. Please seal Ufer ground view outlet (cover). FBC EC TABLE R402.4.1.1 3. Please raise AC Pad min 3" above surrounding ground. FBCR M1305.1.4.1 4. No Hot water at fixtures. FBCR P2705.1 – 4 5. Please seal wall penetration at AHU Power. R302.11(4) 6. Please seal garage ceiling at cat5. FBC R302.5.3 7. Please seal garage wall at HW power. FBC R302.5.3 8. Please install weather strip at Garage to House door. FBC R302.5.1
ROW - FINAL INSPECTION 05/27/2026 APPROVED EMADISON
Note: ** AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
U -UTILITY RESIDENTIAL FINAL 05/22/2026 APPROVED TLOWE
ROW - FINAL INSPECTION 05/22/2026 Disapproved -FEE REQUIRED EMADISON
Note: ** 05/22/26 BUILDER IS REQUIRED TO HAVE PORT-A-JPOHN REMOVED FROM THE MEDIAN YOU CAN PLACE ON YOUR DRIVEWAY FOR PICK UP.
ROW - FINAL APRON (AFTER POUR) 05/22/2026 APPROVED EMADISON
Note: ** AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW- FINAL SURVEY/GRADING CERTIFICATION 05/21/2026 APPROVED EMADISON
Note: ** Effective 03/25/26, the ROW Field Survey requirement is no longer in effect for Final Lot Grading and Drainage Certificates for new construction on subdivision and infill lots. All Final Lot Grading and Drainage Certificates for these projects will now be reviewed and approved only in the office. Field verification for the ROW-FIELD SURVEY will no longer be required as part of the standard approval process for these permit types. ** PER P. BUCKLEY CHIEF BUILDING Inspector. ** SCHEDULE YOUR FINALS WHEN YOU ARE READY TO DO SO
ROW- PRE-APRON (PRE-POUR) 04/29/2026 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. WOOD CONTROL JOINTS ARE PROHIBITED IN THE RIGHT-OF-WAY. SAWCUT SHALL BE PROVIDED AT THE EDGE OF ROW AND EVERY 12' THEREAFTER, OR A MINIMUM OF 2 SAWCUTS WHICHEVER IS GREATER" 4/23/2026 - PREVIOUS INSPECTION NOTES 04-23-26 TPOLACEK*** CULVERT IS NOT SET CENTERED IN DRIVEWAY POUR AREA. THE LEFT SIDE IS 14" FROM EDGE OF DRIVEWAY WHILE THE RIGHT SIDE IS 26" PLEASE SET PIOPE IN ACCORDANCE WITH CODE BELOW. * RESIDENTIAL CONCRETE DRIVEWAY CULVERT DETAIL DRAWING 300. E "CULVERT TO BE CENTERED ON DRIVEWAY. CULVERT SHALL BE CONCRETE ENCASED TO SPRING LINE AND AT LEAST 12"" ON EACH SIDE SEE SECTION B-B. Sec 300.E"
ROW- PRE-APRON (PRE-POUR) 04/23/2026 Disapproved -FEE REQUIRED TPOLACEK
Note: 04-23-26 TPOLACEK*** CULVERT IS NOT SET CENTERED IN DRIVEWAY POUR AREA. THE LEFT SIDE IS 14" FROM EDGE OF DRIVEWAY WHILE THE RIGHT SIDE IS 26" PLEASE SET PIOPE IN ACCORDANCE WITH CODE BELOW. * RESIDENTIAL CONCRETE DRIVEWAY CULVERT DETAIL DRAWING 300. E "CULVERT TO BE CENTERED ON DRIVEWAY. CULVERT SHALL BE CONCRETE ENCASED TO SPRING LINE AND AT LEAST 12"" ON EACH SIDE SEE SECTION B-B. Sec 300.E"
ELECTRIC - EARLY POWER 03/27/2026 APPROVED HCAMACHO
Note: 3/26/2026 - PREVIOUS INSPECTION NOTES 240v wiring for Hot water tank needs to be encased in a holding box with a cover for accidental touch. NEC 110.27 Inspector Notes from Inspection 2200 2-17-26 1. Emailed FPL at 9:47.
ELECTRIC - EARLY POWER 03/26/2026 Disapproved - NO FEE JSTEWART
Note: 240v wiring for Hot water tank needs to be encased in a holding box with a cover for accidental touch. NEC 110.27 Inspector Notes from Inspection 2200 2-17-26 1. Emailed FPL at 9:47.
GRAVITY SEWER TEST 03/24/2026 APPROVED KSANDOE
SEWER TIE IN 03/24/2026 APPROVED KSANDOE
PEP TANK INSTALLATION REQUEST 03/09/2026 APPROVED ISANDERSON
INSULATION 03/04/2026 APPROVED CVANSTRAHLEN
Note: 3/3/2026 - PREVIOUS INSPECTION NOTES 1. Missing foil insulation on the bedroom on the right side around the window. 2/23/2026 - PREVIOUS INSPECTION NOTES
INSULATION 03/03/2026 Disapproved - NO FEE HCAMACHO
Note: 1. Missing foil insulation on the bedroom on the right side around the window. 2/23/2026 - PREVIOUS INSPECTION NOTES
INSULATION 02/23/2026 CANCELLED BY APPLICANT KSANDOE
LATH/BRICK/ WATER BARRIER 02/20/2026 APPROVED KSANDOE
Note: 2/12/2026 - PREVIOUS INSPECTION NOTES 2/12/26 1. Front entry door needs to be sealed with approved material before placing lath and trim around it FBCR 402.4.1.1
ALL ROUGH 02/17/2026 APPROVED BTAYLOR
ELECTRIC-TUG 02/17/2026 APPROVED - AS NOTED BTAYLOR
Note: 2-17-26 1. Emailed FPL at 9:47.
LATH/BRICK/ WATER BARRIER 02/12/2026 Disapproved - NO FEE MCONTRYMAN
Note: 2/12/26 1. Front entry door needs to be sealed with approved material before placing lath and trim around it FBCR 402.4.1.1
ROOF SHEATHING / BRACES/TIES/DOWN CELL 02/05/2026 APPROVED JSTEWART
ROOF VALLEY & METAL 02/03/2026 APPROVED JSTEWART
ROOF SHEATHING 01/28/2026 APPROVED JSTEWART
WALL SHEATHING 01/28/2026 APPROVED JSTEWART
TIE BEAM / LINTEL 01/21/2026 APPROVED MCONTRYMAN
MONOLITHIC SLAB 01/12/2026 APPROVED JSTEWART
PLUMBING 1ST ROUGH UNDERGROUND 01/07/2026 APPROVED MCONTRYMAN
FORMBOARD SURVEY (OFFICE USE ONLY) 01/06/2026 APPROVED RRICKS
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 01/06/2026 APPROVED PKNAPIK
WATER METER INSTALLATION REQUEST 12/08/2025 APPROVED CBOWERMASTER
Note: 11/20/2025 8:33:21 AM- PREVIOUS INSPECTION NOTES logs on left side of property
WATER METER INSTALLATION REQUEST 11/19/2025 Disapproved -FEE REQUIRED CBOWERMASTER
Note: logs on left side of property

Review History

Department Status Date In Date Out
BLD HOLD 01/06/2026 01/06/2026
Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM Please provide Final building pad certification letter.
BLD COMPLETE 01/06/2026 01/06/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
SW1 COMPLETE 01/06/2026 01/06/2026
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 01/06/2026 01/06/2026
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
MECH COMPLETE 11/05/2025 11/06/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH COMPLETE 10/10/2025 10/15/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 10/06/2025 10/08/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
CUSVC COMPLETE 10/06/2025 10/10/2025
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 10/06/2025 10/09/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 10/06/2025 10/06/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS CANCEL 10/06/2025 10/07/2025
LOCATE COMPLETE 10/06/2025 10/09/2025
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH HOLD 10/06/2025 10/07/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Direction house faces on Energy Calcs does not match the site plan. Revise to match per R405.4.2.1 FBC Energy Conservation 2023 8Th Edition
SW1 COMPLETE 10/06/2025 10/06/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 10/06/2025 10/07/2025
Note: Released By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM
SWALE COMPLETE 10/06/2025 10/27/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
RSI REINSPECTION 1 ¤35.00 05/26/2026
RSI REINSPECTION 1 ¤35.00 05/21/2026
REINSPECTION FEE ¤40.00 04/10/2026
PLAN REVIEW - REVISION ¤32.50 04/10/2026
CONTRACTOR CHANGE ¤20.00 04/10/2026
CONTRACTOR CHANGE ¤20.00 04/10/2026
FC IMPACT FEE EMS ¤62.00 11/05/2025
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 11/05/2025
FC IMPACT FEE LIBRARY ¤268.00 11/05/2025
FIRE RES IMPACT FEE 10-25 ¤942.00 11/05/2025
PEP TANK INSTALL ¤756.74 11/05/2025
PARKS IMPACT FEE 10-25 ¤3,164.00 11/05/2025
CONTRACTOR CHANGE ¤20.00 11/05/2025
WATER- TURN ON ¤50.00 11/05/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 11/05/2025
INSPECTION - RESIDENTIAL ¤849.75 11/05/2025
PLAN REVIEW - RESIDENTIAL ¤241.02 11/05/2025
SCHOOL BOARD IMPACT FEE RES ¤5,450.00 11/05/2025
WASTEWATER MAIN EXTENSION IMPA ¤2,385.00 11/05/2025
SURCHARGE FS 533.721 ¤11.21 11/05/2025
SURCHARGE - FS 468.631 ¤16.81 11/05/2025
SW ENG - FOUNDATION SURVEY ¤20.00 11/05/2025
SW ENG INSPECTION 80 ¤80.00 11/05/2025
SW ENG PRE APRON ¤30.00 11/05/2025
SW ENG - REVIEW 20 ¤20.00 11/05/2025
SW ENG RES REVIEW 200 ¤200.00 11/05/2025
WATER METER W/ TAP ¤2,326.93 11/05/2025
TRANSP RES IMPACT FEE 10-25 ¤6,065.93 11/05/2025
SEWER CREDIT (¤850.00) 11/05/2025
WASTEWATER PERM INSPECTION ¤80.00 11/05/2025
WASTEWATER PERM REVIEW ¤25.00 11/05/2025
SEWER CAPITAL FACILITY ¤4,415.00 11/05/2025
WATER CAPITAL FACILITY FEE ¤3,790.49 11/05/2025
WATER PERMIT REVIEW ¤25.00 11/05/2025
WATER MAIN EXTENSION IMPACT ¤917.27 11/05/2025
SITE PLAN 30 ¤30.00 11/05/2025
Fees Total Due: ¤0.00 Total Paid: ¤31,822.65