I want to search for...
Permit #2025100164
Permit Details
Status: INSPECT
| Parcel Id: 07-11-31-7010-00230-0370 |
| CONDITIONED SPACE: 2287 sqft |
| PATIO/DECK (NO ROOF) : 342 sqft |
| GARAGE: 479 sqft |
| OPENED PORCH (WITH ROOF) : 100 sqft |
| Total Square Footage: 3208 sqft |
| Block: 00230 |
| Subdivision: - |
| Job Phone: 386-627-0430 |
| Location Address: 6 FELWOOD PL |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 11/06/2025 |
| NOC: RECORDED |
| Applicant name: ANNA WIKTORIA LISOWSKI |
| Owner: LICARI BRITTANY |
|
Address 2 ROSALIE PLACE PALM COAST, FL 32164 |
| Lot: 0370 |
| Contracted Stated Job Value: ¤305,500.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
GOLDEN FOX HOME REMODELING, INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
72 HERNANDEZ AVE PALM COAST, FL 32137 |
CBC1259266 (Exp: 08/31/2026) | 386-627-0430 |
Sub Contractors
JUAN CARLOS GONZALEZ
| Status | Location Address | State License Number |
| ACTIVE |
1328 COUNTY ROAD 308 CRESCENT CITY, FL 32112 |
RF11067806 (Exp: 08/31/2027) |
SCOTT H STILLWELL
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4500 US 1 UNIT 206 BUNNELL, FL 32110 |
CAC1819433 (Exp: 08/31/2026) | 386-864-4404 |
WILLIAM TODD SIKES
| Status | Location Address | State License Number | Phone |
| ACTIVE |
83 PORT ROYAL DR ST AUGUSTINE, FL 32084 |
EC0002726 (Exp: 08/31/2026) | 904-762-8762 |
CHRISTOPHER DANIEL FULTON
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
2 MARKET PLACE PALM COAST, FL 32137 |
UNIT D PALM COAST, FL 32137 |
CRC1332537 (Exp: 08/31/2026) | 386-445-7945 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROW- PRE-APRON (PRE-POUR) | 05/28/2026 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. WOOD CONTROL JOINTS ARE PROHIBITED IN THE RIGHT-OF-WAY. SAWCUT SHALL BE PROVIDED AT THE EDGE OF ROW AND EVERY 12' THEREAFTER, OR A MINIMUM OF 2 SAWCUTS WHICHEVER IS GREATER" 5/27/2026 - PREVIOUS INSPECTION NOTES ** 05/27/26 NO CORRECTIONS MADE SINCE PREVIOUS INSPECTION ON 05/26/26 MITERED ENDS OF CULVERT ARE REQUIRED TO HAVE A FOOTER A MINIMUM 6X6X18 INCHES FOOTERS ARE FILLED IN WITH MATERIAL NEED TO RE-DIG THEM ** ENSURE 6 INCHES OF CONCRETE IN ENTIRE APRON OUT TO EDGE OF ROAD ** SEE ATTACHED PHOTOS ___________________________________________________________________________________________________________________________ 5/26/2026 - PREVIOUS INSPECTION NOTES ** 05/26/26 MITERED ENDS OF CULVERT ARE REQUIRED TO HAVE A FOOTER A MINIMUM 6X6X18 INCHES FOOTERS ARE FILLED IN WITH MATERIAL NEED TO RE-DIG THEM ** ENSURE 6 INCHES OF CONCRETE IN ENTIRE APRON OUT TO EDGE OF ROAD | |||
| ROW- PRE-APRON (PRE-POUR) | 05/27/2026 | Disapproved -FEE REQUIRED | EMADISON |
| Note: ** 05/27/26 NO CORRECTIONS MADE SINCE PREVIOUS INSPECTION ON 05/26/26 MITERED ENDS OF CULVERT ARE REQUIRED TO HAVE A FOOTER A MINIMUM 6X6X18 INCHES FOOTERS ARE FILLED IN WITH MATERIAL NEED TO RE-DIG THEM ** ENSURE 6 INCHES OF CONCRETE IN ENTIRE APRON OUT TO EDGE OF ROAD ** SEE ATTACHED PHOTOS ___________________________________________________________________________________________________________________________ 5/26/2026 - PREVIOUS INSPECTION NOTES ** 05/26/26 MITERED ENDS OF CULVERT ARE REQUIRED TO HAVE A FOOTER A MINIMUM 6X6X18 INCHES FOOTERS ARE FILLED IN WITH MATERIAL NEED TO RE-DIG THEM ** ENSURE 6 INCHES OF CONCRETE IN ENTIRE APRON OUT TO EDGE OF ROAD | |||
| ROW- PRE-APRON (PRE-POUR) | 05/26/2026 | Disapproved -FEE REQUIRED | EMADISON |
| Note: ** 05/26/26 MITERED ENDS OF CULVERT ARE REQUIRED TO HAVE A FOOTER A MINIMUM 6X6X18 INCHES FOOTERS ARE FILLED IN WITH MATERIAL NEED TO RE-DIG THEM ** ENSURE 6 INCHES OF CONCRETE IN ENTIRE APRON OUT TO EDGE OF ROAD | |||
| ELECTRIC - EARLY POWER | 04/22/2026 | APPROVED | MCONTRYMAN |
| Note: 4/15/2026 - PREVIOUS INSPECTION NOTES 4/15/26 1. At time of inspection, cabinets were being installed and wires were not safed off NEC 440.14 Inspector Notes from Inspection 2200 Authorize release of email. | |||
| ELECTRIC - EARLY POWER | 04/15/2026 | Disapproved - NO FEE | MCONTRYMAN |
| Note: 4/15/26 1. At time of inspection, cabinets were being installed and wires were not safed off NEC 440.14 Inspector Notes from Inspection 2200 Authorize release of email. | |||
| GRAVITY SEWER TEST | 03/06/2026 | APPROVED | MCONTRYMAN |
| Note: Inspector Notes from Inspection 2060 FBC -3303.5 SWALE BLOCKED, WATER SERVICE NOT RAN YET | |||
| SEWER TIE IN | 03/06/2026 | APPROVED | MCONTRYMAN |
| Note: Inspector Notes from Inspection 2060 FBC -3303.5 SWALE BLOCKED, WATER SERVICE NOT RAN YET | |||
| INSULATION | 02/06/2026 | APPROVED | HCAMACHO |
| Note: 2/5/2026 - PREVIOUS INSPECTION NOTES 1. No spray insulation cert on site 2. All top plate penetrations require approved fire foam, over elec panel. and multiple locations in home at T/P | |||
| INSULATION | 02/05/2026 | Disapproved - NO FEE | MKRASKI |
| Note: 1. No spray insulation cert on site 2. All top plate penetrations require approved fire foam, over elec panel. and multiple locations in home at T/P | |||
| LATH/BRICK/ WATER BARRIER | 01/27/2026 | APPROVED | MCONTRYMAN |
| ALL ROUGH | 01/23/2026 | APPROVED | MCONTRYMAN |
| Note: 1/13/2026 - PREVIOUS INSPECTION NOTES 1. The window in the Guest Bath needs to be Tempered. (The window in the master toilet area does not need to be tempered, maybe that window was installed in the wrong bath). 2. Missing Exterior Front Door, Pool bath door and house to garage door. 3. All arch windows, the archs are not anchored.(I could not see an anchors).Provide Installation instrutions. 4. Need nail plate on plumbing in the guest bath (marked). FBCR P2603.2.1 5. Wall where the panel is installed needs to be fireblocked with wood all around because of the way the electric wires were run. It needs wood on both sides and top, there is 1-1/2" gap all around. (Marked). FBC R302.11.1 6. Attic access in master closet is blocked by A/C duct. FBCR 807.1 *Ok to install Slider panels.* | |||
| ALL ROUGH | 01/13/2026 | Disapproved - NO FEE | HCAMACHO |
| Note: 1. The window in the Guest Bath needs to be Tempered. (The window in the master toilet area does not need to be tempered, maybe that window was installed in the wrong bath). 2. Missing Exterior Front Door, Pool bath door and house to garage door. 3. All arch windows, the archs are not anchored.(I could not see an anchors).Provide Installation instrutions. 4. Need nail plate on plumbing in the guest bath (marked). FBCR P2603.2.1 5. Wall where the panel is installed needs to be fireblocked with wood all around because of the way the electric wires were run. It needs wood on both sides and top, there is 1-1/2" gap all around. (Marked). FBC R302.11.1 6. Attic access in master closet is blocked by A/C duct. FBCR 807.1 *Ok to install Slider panels.* | |||
| ROOF VALLEY & METAL | 01/12/2026 | APPROVED | MCONTRYMAN |
| WALL SHEATHING | 01/12/2026 | APPROVED | MCONTRYMAN |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 12/26/2025 | APPROVED | JSTEWART |
| ELECTRIC-TUG | 12/26/2025 | APPROVED - AS NOTED | JSTEWART |
| Note: Authorize release of email. | |||
| TIE BEAM / LINTEL | 12/08/2025 | APPROVED | MKRASKI |
| MONOLITHIC SLAB | 12/01/2025 | APPROVED | HCAMACHO |
| PLUMBING 1ST ROUGH UNDERGROUND | 11/26/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: FBC -3303.5 SWALE BLOCKED, WATER SERVICE NOT RAN YET | |||
| FORMBOARD SURVEY (OFFICE USE ONLY) | 11/24/2025 | APPROVED | RRICKS |
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 11/20/2025 | APPROVED | PKNAPIK |
| WATER METER INSTALLATION REQUEST | 11/12/2025 | APPROVED | CBOWERMASTER |
| WILDLIFE CHECK - ENVIRONMENTAL | 10/16/2025 | APPROVED | DRODRIGUEZ |
| U-CROSS CONNECTION | |||
| ROW - FINAL APRON (AFTER POUR) | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | |||
| ROW - FINAL INSPECTION | |||
| U -UTILITY RESIDENTIAL FINAL | |||
| BLD - BUILDING FINAL |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 01/08/2026 | 01/09/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 12/05/2025 | 12/08/2025 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 12/05/2025 | 12/05/2025 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 11/24/2025 | 11/24/2025 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 11/24/2025 | 11/24/2025 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 11/20/2025 | 11/20/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 10/28/2025 | 10/31/2025 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 10/28/2025 | 10/28/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 10/22/2025 | 10/24/2025 |
| Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Previous grading comments not addressed: - ALL DRAINAGE PATTERNS MUST BE ON THE RIGHT AND LEFT PROPERTY DUE TO VACANTS. Note: When proposed homes are built adjacent to vacent lot a common swale between both lots shall be proposed. Please move drainange conveyance swale to lot line between 37 and 38. Please feel free to call or email if there are any questions or concerns. 386-986-4726. | |||
| SW1 | CANCEL | 10/22/2025 | 10/24/2025 |
| SW1 | HOLD | 10/17/2025 | 10/20/2025 |
| Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM 1) MUST HAVE THE 10' OFF SETS EXISTING ELEVATIONS OF THE ADJACENT LOTS IN THE BEHIND THIS LOT. 2) THE SWALE PROFILES DON'T MATCH THE PROPOSED ELEVATIONS ON THE LOT ALL DRAINAGE PATTERNS MUST BE ON THE RIGHT AND LEFT PROPERTY DUE TO VACANTS. | |||
| ZON | COMPLETE | 10/17/2025 | 10/17/2025 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 10/17/2025 | 10/20/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 10/17/2025 | 10/20/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 10/17/2025 | 10/17/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 10/08/2025 | 10/24/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| PLENV | COMPLETE | 10/08/2025 | 10/16/2025 |
| Note: Released By: DYLAN RODRIGUEZ - (386)986-2320 - DRODRIGUEZ@PALMCOASTGOV.COM Staff conducted a site visit on 10/16/25 and found no Gopher Tortoise or their burrows. Staff suggests placing silt fence as soon as possible to prevent tortoise from moving into the lot. If any gopher tortoises are located in the future further coordination may be necessary. | |||
| BLD | HOLD | 10/07/2025 | 10/14/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide roof ventilation calculation. 2. Plan page 1 update code years to current cycle. | |||
| CUSVC | COMPLETE | 10/07/2025 | 10/15/2025 |
| Note: Released By: MICHELLE MCPARTLAND - - | |||
| ELEC | HOLD | 10/07/2025 | 10/10/2025 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need correct outlet spacing in pantry. NEC 2020 210.52 (C) 2. Need correct outlet spacing in master bed room. NEC 2020210.52 3. Need correct outlet spacing in living room. NEC 2020 210.52 | |||
| ENGIN1 | COMPLETE | 10/07/2025 | 10/08/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 10/07/2025 | 10/08/2025 |
| LOCATE | COMPLETE | 10/07/2025 | 10/10/2025 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 10/07/2025 | 10/08/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 10/07/2025 | 10/07/2025 |
| Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Grading comments: - Proposed elevations at the front property line shall be even with or higher than edge of pavement. - Please provide the FFE of the nearest improved adjacent (left and right) lot. - Please depict whether this home is constructed of block or wood. I've attached the SW informational and grading example plans. | |||
| ZON | HOLD | 10/07/2025 | 10/08/2025 |
| Note: Held By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM Panel # on site plan is incorrect Need Right of way License agreement to complete zoning review. (required for paver driveways) |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| SCHOOL BOARD IMPACT FEE RES | ¤5,450.00 | 11/06/2025 |
| WASTEWATER MAIN EXTENSION IMPA | ¤2,385.00 | 11/06/2025 |
| SURCHARGE FS 533.721 | ¤16.36 | 11/06/2025 |
| SURCHARGE - FS 468.631 | ¤24.54 | 11/06/2025 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 11/06/2025 |
| SW ENG INSPECTION 80 | ¤80.00 | 11/06/2025 |
| SW ENG PRE APRON | ¤30.00 | 11/06/2025 |
| SW ENG - REVIEW 20 | ¤20.00 | 11/06/2025 |
| SW ENG RES REVIEW 200 | ¤200.00 | 11/06/2025 |
| WATER METER W/ TAP | ¤2,326.93 | 11/06/2025 |
| TRANSP RES IMPACT FEE 10-25 | ¤8,621.99 | 11/06/2025 |
| SEWER CREDIT | (¤1,147.00) | 11/06/2025 |
| WASTEWATER PERM INSPECTION | ¤80.00 | 11/06/2025 |
| WASTEWATER PERM REVIEW | ¤25.00 | 11/06/2025 |
| SEWER CAPITAL FACILITY | ¤4,415.00 | 11/06/2025 |
| WATER CAPITAL FACILITY FEE | ¤3,790.49 | 11/06/2025 |
| WATER PERMIT REVIEW | ¤25.00 | 11/06/2025 |
| WATER MAIN EXTENSION IMPACT | ¤917.27 | 11/06/2025 |
| SITE PLAN 30 | ¤30.00 | 11/06/2025 |
| WATER- TURN ON | ¤50.00 | 11/06/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 11/06/2025 |
| INSPECTION - RESIDENTIAL | ¤1,251.25 | 11/06/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤354.90 | 11/06/2025 |
| FC IMPACT FEE EMS | ¤62.00 | 11/06/2025 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 11/06/2025 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 11/06/2025 |
| FIRE RES IMPACT FEE 10-25 | ¤942.00 | 11/06/2025 |
| PARKS IMPACT FEE 10-25 | ¤3,164.00 | 11/06/2025 |
| RSI REINSPECTION 1 | ¤35.00 | |
| RSI REINSPECTION 1 | ¤35.00 | |
| Fees | Total Due: ¤70.00 | Total Paid: ¤33,650.73 |