Permit #2025100246

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7024-00080-0160
Total Square Footage: 2475 sqft
Block: 00080
Subdivision: 7024 -
Job Phone: (386)672-1950
Location Address: 25 PRINCESS DOLORES LN
Type: ME - MECHANICAL
Issue Date: 10/08/2025
NOC: Unknown
Applicant name: RICHARD LEE VONBROCKEN
Owner: DELUCA THOMAS & PATRICIA J H&W

Address

16 CAMEO DR

MONROE TOWNSHIP, NJ 08831

Lot: 0160
Contracted Stated Job Value: ¤8,475.00
Job Description: HVAC CHANGEOUT
Type: CN

Contractor

VON-AIRE INC.
Status Location Address State License Number Phone Fax
INACTIVE

1738 STATE AVE

HOLLY HILL, FL 32117

CAC035516 (Exp: 08/31/2026) (386)672-1950 (386)672-1952

Inspection History

Type Request Date Result Inspector
HVAC FINAL 10/27/2025 FINAL APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 10/27/2025 12:10:37 PM *** 10/17/2025 - PREVIOUS INSPECTION NOTES 10/17/25: A Virtual inspection will be available IF requested at the time of scheduling the re-inspection. If requesting a Virtual Re-inspection, please schedule the re-inspection for the same day that the deficiencies will be corrected and a FaceTime or Google Meet live virtual inspection can be completed. (Pictures are not approved). 1). AHU breaker is too small (Min.-45.1 amp / Max.-50 amp -- 45 amp installed). NEC 440.4 2). 1 of 3 locking caps is not locking. Left cap on ODU. FBCR M1411.8 3). Ceiling needs to be sealed where new linest and return duct enter attic space. FBC-R302.11
HVAC FINAL 10/17/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 10/17/2025 1:44:58 PM *** 10/17/25: A Virtual inspection will be available IF requested at the time of scheduling the re-inspection. If requesting a Virtual Re-inspection, please schedule the re-inspection for the same day that the deficiencies will be corrected and a FaceTime or Google Meet live virtual inspection can be completed. (Pictures are not approved). 1). AHU breaker is too small (Min.-45.1 amp / Max.-50 amp -- 45 amp installed). NEC 440.4 2). 1 of 3 locking caps is not locking. Left cap on ODU. FBCR M1411.8 3). Ceiling needs to be sealed where new linest and return duct enter attic space. FBC-R302.11

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 10/24/2025
SURCHARGE FS 533.721 ¤2.00 10/08/2025
SURCHARGE - FS 468.631 ¤2.00 10/08/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 10/08/2025
INSPECTION - MECHANICAL ¤60.00 10/08/2025
Fees Total Due: ¤0.00 Total Paid: ¤134.00