I want to search for...
Permit #2025100358
Permit Details
Status: INSPECT
| Parcel Id: 07-11-31-7026-00590-0110 |
| CONDITIONED SPACE: 1504 sqft |
| GARAGE: 396 sqft |
| OPENED PORCH (WITH ROOF) : 112 sqft |
| Total Square Footage: 2012 sqft |
| Block: 00590 |
| Subdivision: - |
| Job Phone: 407-476-8195 |
| Location Address: 13 PINEAPPLE DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 12/03/2025 |
| NOC: RECORDED |
| Applicant name: CARLETTE RENE WITTE |
| Owner: INB BFS LAND LLC |
|
Address 3670 MAGUIRE BOULEVARD ORLANDO, FL 32803 |
|
Address SUITE 220 ORLANDO, FL 32803 |
| Lot: 0110 |
| Contracted Stated Job Value: ¤150,000.00 |
| Job Description: single family residence |
| Type: CN |
Contractor
INNOVATIVE NATIONWIDE BUILDERS INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3670 MAGUIRE BLVD #220 , |
CRC1330026 (Exp: 08/31/2026) | 855-694-6634 |
Sub Contractors
TERRY BRICE DICKERSON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4300 ST JOHN'S PARKWAY ALPHARETTA, GA 30009 |
CCC1326209 (Exp: 08/31/2026) | 407-548-6733 |
ANTHONY OKEITH FENNELL
| Status | Location Address | State License Number | Phone |
| ACTIVE |
217 N. WESTMONTE DR, SUITE 1007 ALTAMONTE SPRINGS, FL 32714 |
EC13011194 (Exp: 08/31/2026) | 407-404-4000 |
HEATH EDWARD SANFORD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
126 EAST END RD SAN MATEO, FL 32187 |
CFC1429896 (Exp: 08/31/2026) | 386-871-8823 |
JASON LEE JAMES
| Status | Location Address | State License Number | Phone |
| ACTIVE |
217 N WESTMONTE DR SUITE 1007 ALTAMONTE SPRINGS, FL 32714 |
CAC1820196 (Exp: 08/31/2026) | 407-404-4000 |
Inspection History
| Type | Request Date | Result | Inspector |
| ELECTRIC - EARLY POWER | 04/30/2026 | APPROVED | HCAMACHO |
| Note: 4/29/2026 - PREVIOUS INSPECTION NOTES 4/29/26: 1). House is energized prior to approved Early Power inspection. NEC-110.27 2). dead front cover at Meter panel is missing a screw. NEC-110.3(B) | |||
| ELECTRIC - EARLY POWER | 04/29/2026 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 4/29/2026 10:41:39 AM *** 4/29/26: 1). House is energized prior to approved Early Power inspection. NEC-110.27 2). dead front cover at Meter panel is missing a screw. NEC-110.3(B) | |||
| ROW- PRE-APRON (PRE-POUR) | 04/24/2026 | APPROVED | FSLADISH |
| Note: 4/24/26 PIPE INVERT IS GOOD AT TIME OF THIS INSPECTION. BUILDER REFER TO CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED. DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR BEFORE POURING. . IF FIBERGLASS OPTION IS USED, BUILDER REQUIRED TO USE 3000 PSI CONCRETE AT THE TIME OF THE INSPECTION READY TO POUR, IF RAIN, BUILDER SHOULD DOUBLE CHECK SITE FOR ANY STANDING WATER AND VERIFY PIPE ELEVATION HAS NOT CHANGED. NO EXPANSION JOINTS ALLOWED, AT THE TIME OF THIS INSPECTION ALL MINIMUM COPC REQUIREMENTS ARE MET. BUILDER TO BE HELD RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR. | |||
| GRAVITY SEWER TEST | 04/14/2026 | APPROVED | KSANDOE |
| SEWER TIE IN | 04/14/2026 | APPROVED | KSANDOE |
| INSULATION | 03/23/2026 | APPROVED | HCAMACHO |
| Note: 3/20/2026 - PREVIOUS INSPECTION NOTES 3/20/26: Previosly listed item 3 is not fully resolved. 3). Kitchen wall at left bedrooms. Missing fireblocking at ceiling level change. Every stud bay. FBc-R302.11 THE FIREBLOCKING HAS NOTCHES THAT WELL EXCEED THE ALLOWABLE ANNULAR SPACE OF 1/2' FOR FIRESTOP. ALSO, SPACES AND OPENINGS REQUIRE FIRESTOP. 3/17/2026 - PREVIOUS INSPECTION NOTES 3/17/26: 1). Missing firestop at top plate penetration in garage. FS written on stud. FBC-R302.11 2). Master Bathroom: Missing firestop at shower pipe top plate penetration. Stud marked FS. FBC-R302.11 3). Kitchen wall at left bedrooms. Missing fireblocking at ceiling level change. Every stud bay. FBc-R302.11 Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 3/12/2026 10:50:27 AM *** 3/12/26: Check at Insulation. 1). Wires are not phased out in breaker panel as required. NEC 200.6(B) | |||
| INSULATION | 03/20/2026 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 3/20/2026 10:08:19 AM *** 3/20/26: Previosly listed item 3 is not fully resolved. 3). Kitchen wall at left bedrooms. Missing fireblocking at ceiling level change. Every stud bay. FBc-R302.11 THE FIREBLOCKING HAS NOTCHES THAT WELL EXCEED THE ALLOWABLE ANNULAR SPACE OF 1/2' FOR FIRESTOP. ALSO, SPACES AND OPENINGS REQUIRE FIRESTOP. 3/17/2026 - PREVIOUS INSPECTION NOTES 3/17/26: 1). Missing firestop at top plate penetration in garage. FS written on stud. FBC-R302.11 2). Master Bathroom: Missing firestop at shower pipe top plate penetration. Stud marked FS. FBC-R302.11 3). Kitchen wall at left bedrooms. Missing fireblocking at ceiling level change. Every stud bay. FBc-R302.11 Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 3/12/2026 10:50:27 AM *** 3/12/26: Check at Insulation. 1). Wires are not phased out in breaker panel as required. NEC 200.6(B) | |||
| INSULATION | 03/17/2026 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 3/17/2026 2:49:59 PM *** 3/17/26: 1). Missing firestop at top plate penetration in garage. FS written on stud. FBC-R302.11 2). Master Bathroom: Missing firestop at shower pipe top plate penetration. Stud marked FS. FBC-R302.11 3). Kitchen wall at left bedrooms. Missing fireblocking at ceiling level change. Every stud bay. FBc-R302.11 Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 3/12/2026 10:50:27 AM *** 3/12/26: Check at Insulation. 1). Wires are not phased out in breaker panel as required. NEC 200.6(B) | |||
| PEP TANK INSTALLATION REQUEST | 03/17/2026 | APPROVED | ISANDERSON |
| ELECTRIC-TUG | 03/13/2026 | APPROVED | RMARTIN |
| Note: 3/12/2026 - PREVIOUS INSPECTION NOTES 3/12/26: 1). TUG outlet needs to be secured to the wall. NEC-334.30 2). Outlet cover is broken. Must be replaced. NEC-110.3(B) 3). Main SER wires cannot be landed at the meter panel for underground source and prior to approved Early Power Inspection. NEC-110.27 | |||
| ALL ROUGH | 03/12/2026 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 3/12/2026 10:50:27 AM *** 3/12/26: Check at Insulation. 1). Wires are not phased out in breaker panel as required. NEC 200.6(B) | |||
| ELECTRIC-TUG | 03/12/2026 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 3/12/26: 1). TUG outlet needs to be secured to the wall. NEC-334.30 2). Outlet cover is broken. Must be replaced. NEC-110.3(B) 3). Main SER wires cannot be landed at the meter panel for underground source and prior to approved Early Power Inspection. NEC-110.27 | |||
| LATH/BRICK/ WATER BARRIER | 03/10/2026 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 3/10/2026 3:13:38 PM *** Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 3/6/2026 1:02:43 PM *** 3/6/26: NOTE: Found damaged set of plans in house. Please provide a new set of plans along with all required documents for next inspection. FBC [A]107.3.1 | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/06/2026 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 3/6/2026 1:02:43 PM *** 3/6/26: NOTE: Found damaged set of plans in house. Please provide a new set of plans along with all required documents for next inspection. FBC [A]107.3.1 | |||
| ROOF VALLEY & METAL | 03/05/2026 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 3/5/2026 1:51:19 PM *** | |||
| WALL SHEATHING | 03/05/2026 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 3/5/2026 1:51:03 PM *** 3/3/2026 - PREVIOUS INSPECTION NOTES 3/3/26: Please see notes from 1st disapproved Wall Sheathing inspection on 2/27/26: 2/27/26: 1). Wall sheathing is incomplete at face wall above entry where flashing will be installed. FBC [A]107.4 Inspector Notes from Inspection 2465 *** NOTES ADDED BY RSIMS 2/27/2026 11:54:13 AM *** 2/27/26: 1). At 2-ply Truss T01 > install a2ft. minimum length of 2" x 4" parallel to truss directly under the hole in the sheathing. FBC [A]107.4 *** NOTES ADDED BY RSIMS 2/27/2026 11:52:13 AM *** 2/27/26: 1). Wall sheathing is incomplete at face wall above entry where flashing will be installed. FBC [A]107.4 Inspector Notes from Inspection 2340 *** NOTES ADDED BY RSIMS 2/18/2026 12:05:36 PM *** 2/18/26: 1). Need dumpster on site and piles of trash and debris cleaned up to make site safe for inspections, etc. FBC 3302.2 / FBC-[A] 101.3 Inspector Notes from Inspection 2250 2/11/26 The sides show signs of possible cave in. At time of inspection, everything was good and proper clearance was visible. Please check before pouring for proper clearance and any wash-in/cave-in | |||
| WALL SHEATHING | 03/03/2026 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 3/3/2026 2:22:24 PM *** 3/3/26: Please see notes from 1st disapproved Wall Sheathing inspection on 2/27/26: 2/27/26: 1). Wall sheathing is incomplete at face wall above entry where flashing will be installed. FBC [A]107.4 Inspector Notes from Inspection 2465 *** NOTES ADDED BY RSIMS 2/27/2026 11:54:13 AM *** 2/27/26: 1). At 2-ply Truss T01 > install a2ft. minimum length of 2" x 4" parallel to truss directly under the hole in the sheathing. FBC [A]107.4 *** NOTES ADDED BY RSIMS 2/27/2026 11:52:13 AM *** 2/27/26: 1). Wall sheathing is incomplete at face wall above entry where flashing will be installed. FBC [A]107.4 Inspector Notes from Inspection 2340 *** NOTES ADDED BY RSIMS 2/18/2026 12:05:36 PM *** 2/18/26: 1). Need dumpster on site and piles of trash and debris cleaned up to make site safe for inspections, etc. FBC 3302.2 / FBC-[A] 101.3 Inspector Notes from Inspection 2250 2/11/26 The sides show signs of possible cave in. At time of inspection, everything was good and proper clearance was visible. Please check before pouring for proper clearance and any wash-in/cave-in | |||
| WALL SHEATHING | 02/27/2026 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 2/27/2026 11:52:13 AM *** 2/27/26: 1). Wall sheathing is incomplete at face wall above entry where flashing will be installed. FBC [A]107.4 Inspector Notes from Inspection 2340 *** NOTES ADDED BY RSIMS 2/18/2026 12:05:36 PM *** 2/18/26: 1). Need dumpster on site and piles of trash and debris cleaned up to make site safe for inspections, etc. FBC 3302.2 / FBC-[A] 101.3 Inspector Notes from Inspection 2250 2/11/26 The sides show signs of possible cave in. At time of inspection, everything was good and proper clearance was visible. Please check before pouring for proper clearance and any wash-in/cave-in | |||
| ROOF SHEATHING | 02/27/2026 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 2/27/2026 11:54:13 AM *** 2/27/26: 1). At 2-ply Truss T01 > install a2ft. minimum length of 2" x 4" parallel to truss directly under the hole in the sheathing. FBC [A]107.4 Inspector Notes from Inspection 2340 *** NOTES ADDED BY RSIMS 2/18/2026 12:05:36 PM *** 2/18/26: 1). Need dumpster on site and piles of trash and debris cleaned up to make site safe for inspections, etc. FBC 3302.2 / FBC-[A] 101.3 Inspector Notes from Inspection 2250 2/11/26 The sides show signs of possible cave in. At time of inspection, everything was good and proper clearance was visible. Please check before pouring for proper clearance and any wash-in/cave-in | |||
| TIE BEAM / LINTEL | 02/18/2026 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 2/18/2026 12:05:36 PM *** 2/18/26: 1). Need dumpster on site and piles of trash and debris cleaned up to make site safe for inspections, etc. FBC 3302.2 / FBC-[A] 101.3 Inspector Notes from Inspection 2250 2/11/26 The sides show signs of possible cave in. At time of inspection, everything was good and proper clearance was visible. Please check before pouring for proper clearance and any wash-in/cave-in | |||
| MONOLITHIC SLAB | 02/11/2026 | APPROVED - AS NOTED | MCONTRYMAN |
| Note: 2/11/26 The sides show signs of possible cave in. At time of inspection, everything was good and proper clearance was visible. Please check before pouring for proper clearance and any wash-in/cave-in | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 02/03/2026 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 2/3/2026 2:42:26 PM *** | |||
| FORMBOARD SURVEY (OFFICE USE ONLY) | 02/02/2026 | APPROVED | RRICKS |
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 01/30/2026 | APPROVED | PKNAPIK |
| WATER METER INSTALLATION REQUEST | 01/08/2026 | APPROVED | CBOWERMASTER |
| BLD - BUILDING FINAL | |||
| U-CROSS CONNECTION | |||
| ROW - FINAL APRON (AFTER POUR) | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | |||
| ROW - FINAL INSPECTION | |||
| U -UTILITY RESIDENTIAL FINAL |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 05/15/2026 | 05/18/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 01/30/2026 | 02/02/2026 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 01/30/2026 | 01/30/2026 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 01/29/2026 | 01/30/2026 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 01/06/2026 | 01/07/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 11/19/2025 | 11/19/2025 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 11/13/2025 | 11/13/2025 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 11/13/2025 | 11/18/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 11/13/2025 | 11/14/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| ZON | HOLD | 11/13/2025 | 11/17/2025 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM add the porch dimension | |||
| MECH | HOLD | 11/07/2025 | 11/10/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Design location on heatload needs to be Daytona Beach | |||
| SW1 | HOLD | 11/07/2025 | 11/10/2025 |
| Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM As noted from last review need to reshot elevations on the ffe of #11 to the left. The ffe doesn't match of what elevations on the site plan. from permited or COPC surveyors shot ffe at. | |||
| BLD | CANCEL | 11/07/2025 | 11/13/2025 |
| ZON | COMPLETE | 11/07/2025 | 11/07/2025 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 10/24/2025 | 10/24/2025 |
| Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Additional Grading Comments: - COPC Survey team confrimed an FFE of 27.75' on #11, which is incorrectly labeled on the grading plan submitted as #16. - Please revise as needed. | |||
| SWALE | COMPLETE | 10/14/2025 | 10/24/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 10/10/2025 | 10/17/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 10/10/2025 | 10/16/2025 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 10/10/2025 | 10/16/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 10/10/2025 | 10/14/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 10/10/2025 | 10/15/2025 |
| LOCATE | COMPLETE | 10/10/2025 | 10/16/2025 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | HOLD | 10/10/2025 | 10/15/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Direction house faces on Energy Calcs does not match the site plan. Revise to match per R405.4.2.1 FBC Energy Conservation 2023 8Th Edition | |||
| SW1 | HOLD | 10/10/2025 | 10/16/2025 |
| Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Grading comments: Please provide the edge of pavement elevations. Front property line must be even with or higher than edge of pavement. | |||
| ZON | COMPLETE | 10/10/2025 | 10/14/2025 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| CONTRACTOR CHANGE | ¤20.00 | 06/04/2026 |
| CONTRACTOR CHANGE | ¤20.00 | 06/04/2026 |
| PLAN REVIEW - REVISION | ¤32.50 | 06/04/2026 |
| PLAN REVIEW - REVISION | ¤32.50 | 06/04/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 06/04/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 06/04/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 06/04/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 06/04/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 06/04/2026 |
| CONTRACTOR CHANGE | ¤20.00 | 12/03/2025 |
| WATER- TURN ON | ¤50.00 | 12/03/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 12/03/2025 |
| INSPECTION - RESIDENTIAL | ¤805.75 | 12/03/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤228.54 | 12/03/2025 |
| FC IMPACT FEE EMS | ¤62.00 | 12/03/2025 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 12/03/2025 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 12/03/2025 |
| FIRE RES IMPACT FEE 10-25 | ¤942.00 | 12/03/2025 |
| PEP TANK INSTALL | ¤756.74 | 12/03/2025 |
| PARKS IMPACT FEE 10-25 | ¤3,164.00 | 12/03/2025 |
| RSI DRIVEWAY AFTER POUR | ¤16.25 | 12/03/2025 |
| RSE DRIVE PRE POUR INSPECTION | ¤32.50 | 12/03/2025 |
| RSI FIELD SURVEY INSPECTION | ¤48.75 | 12/03/2025 |
| RSI FORMBOARD REVIEW | ¤16.25 | 12/03/2025 |
| RSI PLAN REVIEW NEW | ¤48.75 | 12/03/2025 |
| RSI FNL SURVEY/GRADING CERT | ¤48.75 | 12/03/2025 |
| RSI ROW FINAL INSPECTION | ¤16.25 | 12/03/2025 |
| SCHOOL BOARD IMPACT FEE RES | ¤5,450.00 | 12/03/2025 |
| WASTEWATER MAIN EXTENSION IMPA | ¤2,385.00 | 12/03/2025 |
| SURCHARGE FS 533.721 | ¤10.64 | 12/03/2025 |
| SURCHARGE - FS 468.631 | ¤15.96 | 12/03/2025 |
| SW ENG RES REVIEW 240 | ¤240.00 | 12/03/2025 |
| WATER METER W/ TAP | ¤2,326.93 | 12/03/2025 |
| TRANSP RES IMPACT FEE 10-25 | ¤5,670.08 | 12/03/2025 |
| SEWER CREDIT | (¤2,255.01) | 12/03/2025 |
| WASTEWATER PERM INSPECTION | ¤80.00 | 12/03/2025 |
| WASTEWATER PERM REVIEW | ¤25.00 | 12/03/2025 |
| SEWER CAPITAL FACILITY | ¤4,415.00 | 12/03/2025 |
| WATER CREDIT | (¤183.92) | 12/03/2025 |
| WATER CAPITAL FACILITY FEE | ¤3,790.49 | 12/03/2025 |
| WATER PERMIT REVIEW | ¤25.00 | 12/03/2025 |
| WATER MAIN EXTENSION IMPACT | ¤917.27 | 12/03/2025 |
| SITE PLAN 30 | ¤30.00 | 12/03/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤30,019.97 |