Permit #2025100358

Permit Details

Status: INSPECT

Parcel Id: 07-11-31-7026-00590-0110
CONDITIONED SPACE: 1504 sqft
GARAGE: 396 sqft
OPENED PORCH (WITH ROOF) : 112 sqft
Total Square Footage: 2012 sqft
Block: 00590
Subdivision: -
Job Phone: 407-476-8195
Location Address: 13 PINEAPPLE DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 12/03/2025
NOC: RECORDED
Applicant name: CARLETTE RENE WITTE
Owner: INB BFS LAND LLC

Address

3670 MAGUIRE BOULEVARD

ORLANDO, FL 32803

Address

SUITE 220

ORLANDO, FL 32803

Lot: 0110
Contracted Stated Job Value: ¤150,000.00
Job Description: single family residence
Type: CN

Contractor

INNOVATIVE NATIONWIDE BUILDERS INC
Status Location Address State License Number Phone
ACTIVE

3670 MAGUIRE BLVD #220

,

CRC1330026 (Exp: 08/31/2026) 855-694-6634

Sub Contractors

TERRY BRICE DICKERSON
Status Location Address State License Number Phone
ACTIVE

4300 ST JOHN'S PARKWAY

ALPHARETTA, GA 30009

CCC1326209 (Exp: 08/31/2026) 407-548-6733
ANTHONY OKEITH FENNELL
Status Location Address State License Number Phone
ACTIVE

217 N. WESTMONTE DR, SUITE 1007

ALTAMONTE SPRINGS, FL 32714

EC13011194 (Exp: 08/31/2026) 407-404-4000
HEATH EDWARD SANFORD
Status Location Address State License Number Phone
ACTIVE

126 EAST END RD

SAN MATEO, FL 32187

CFC1429896 (Exp: 08/31/2026) 386-871-8823
JASON LEE JAMES
Status Location Address State License Number Phone
ACTIVE

217 N WESTMONTE DR SUITE 1007

ALTAMONTE SPRINGS, FL 32714

CAC1820196 (Exp: 08/31/2026) 407-404-4000

Inspection History

Type Request Date Result Inspector
ELECTRIC - EARLY POWER 04/30/2026 APPROVED HCAMACHO
Note: 4/29/2026 - PREVIOUS INSPECTION NOTES 4/29/26: 1). House is energized prior to approved Early Power inspection. NEC-110.27 2). dead front cover at Meter panel is missing a screw. NEC-110.3(B)
ELECTRIC - EARLY POWER 04/29/2026 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 4/29/2026 10:41:39 AM *** 4/29/26: 1). House is energized prior to approved Early Power inspection. NEC-110.27 2). dead front cover at Meter panel is missing a screw. NEC-110.3(B)
ROW- PRE-APRON (PRE-POUR) 04/24/2026 APPROVED FSLADISH
Note: 4/24/26 PIPE INVERT IS GOOD AT TIME OF THIS INSPECTION. BUILDER REFER TO CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED. DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR BEFORE POURING. . IF FIBERGLASS OPTION IS USED, BUILDER REQUIRED TO USE 3000 PSI CONCRETE AT THE TIME OF THE INSPECTION READY TO POUR, IF RAIN, BUILDER SHOULD DOUBLE CHECK SITE FOR ANY STANDING WATER AND VERIFY PIPE ELEVATION HAS NOT CHANGED. NO EXPANSION JOINTS ALLOWED, AT THE TIME OF THIS INSPECTION ALL MINIMUM COPC REQUIREMENTS ARE MET. BUILDER TO BE HELD RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR.
GRAVITY SEWER TEST 04/14/2026 APPROVED KSANDOE
SEWER TIE IN 04/14/2026 APPROVED KSANDOE
INSULATION 03/23/2026 APPROVED HCAMACHO
Note: 3/20/2026 - PREVIOUS INSPECTION NOTES 3/20/26: Previosly listed item 3 is not fully resolved. 3). Kitchen wall at left bedrooms. Missing fireblocking at ceiling level change. Every stud bay. FBc-R302.11 THE FIREBLOCKING HAS NOTCHES THAT WELL EXCEED THE ALLOWABLE ANNULAR SPACE OF 1/2' FOR FIRESTOP. ALSO, SPACES AND OPENINGS REQUIRE FIRESTOP. 3/17/2026 - PREVIOUS INSPECTION NOTES 3/17/26: 1). Missing firestop at top plate penetration in garage. FS written on stud. FBC-R302.11 2). Master Bathroom: Missing firestop at shower pipe top plate penetration. Stud marked FS. FBC-R302.11 3). Kitchen wall at left bedrooms. Missing fireblocking at ceiling level change. Every stud bay. FBc-R302.11 Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 3/12/2026 10:50:27 AM *** 3/12/26: Check at Insulation. 1). Wires are not phased out in breaker panel as required. NEC 200.6(B)
INSULATION 03/20/2026 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 3/20/2026 10:08:19 AM *** 3/20/26: Previosly listed item 3 is not fully resolved. 3). Kitchen wall at left bedrooms. Missing fireblocking at ceiling level change. Every stud bay. FBc-R302.11 THE FIREBLOCKING HAS NOTCHES THAT WELL EXCEED THE ALLOWABLE ANNULAR SPACE OF 1/2' FOR FIRESTOP. ALSO, SPACES AND OPENINGS REQUIRE FIRESTOP. 3/17/2026 - PREVIOUS INSPECTION NOTES 3/17/26: 1). Missing firestop at top plate penetration in garage. FS written on stud. FBC-R302.11 2). Master Bathroom: Missing firestop at shower pipe top plate penetration. Stud marked FS. FBC-R302.11 3). Kitchen wall at left bedrooms. Missing fireblocking at ceiling level change. Every stud bay. FBc-R302.11 Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 3/12/2026 10:50:27 AM *** 3/12/26: Check at Insulation. 1). Wires are not phased out in breaker panel as required. NEC 200.6(B)
INSULATION 03/17/2026 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 3/17/2026 2:49:59 PM *** 3/17/26: 1). Missing firestop at top plate penetration in garage. FS written on stud. FBC-R302.11 2). Master Bathroom: Missing firestop at shower pipe top plate penetration. Stud marked FS. FBC-R302.11 3). Kitchen wall at left bedrooms. Missing fireblocking at ceiling level change. Every stud bay. FBc-R302.11 Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 3/12/2026 10:50:27 AM *** 3/12/26: Check at Insulation. 1). Wires are not phased out in breaker panel as required. NEC 200.6(B)
PEP TANK INSTALLATION REQUEST 03/17/2026 APPROVED ISANDERSON
ELECTRIC-TUG 03/13/2026 APPROVED RMARTIN
Note: 3/12/2026 - PREVIOUS INSPECTION NOTES 3/12/26: 1). TUG outlet needs to be secured to the wall. NEC-334.30 2). Outlet cover is broken. Must be replaced. NEC-110.3(B) 3). Main SER wires cannot be landed at the meter panel for underground source and prior to approved Early Power Inspection. NEC-110.27
ALL ROUGH 03/12/2026 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 3/12/2026 10:50:27 AM *** 3/12/26: Check at Insulation. 1). Wires are not phased out in breaker panel as required. NEC 200.6(B)
ELECTRIC-TUG 03/12/2026 Disapproved -FEE REQUIRED RSIMS
Note: 3/12/26: 1). TUG outlet needs to be secured to the wall. NEC-334.30 2). Outlet cover is broken. Must be replaced. NEC-110.3(B) 3). Main SER wires cannot be landed at the meter panel for underground source and prior to approved Early Power Inspection. NEC-110.27
LATH/BRICK/ WATER BARRIER 03/10/2026 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 3/10/2026 3:13:38 PM *** Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 3/6/2026 1:02:43 PM *** 3/6/26: NOTE: Found damaged set of plans in house. Please provide a new set of plans along with all required documents for next inspection. FBC [A]107.3.1
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/06/2026 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 3/6/2026 1:02:43 PM *** 3/6/26: NOTE: Found damaged set of plans in house. Please provide a new set of plans along with all required documents for next inspection. FBC [A]107.3.1
ROOF VALLEY & METAL 03/05/2026 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 3/5/2026 1:51:19 PM ***
WALL SHEATHING 03/05/2026 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 3/5/2026 1:51:03 PM *** 3/3/2026 - PREVIOUS INSPECTION NOTES 3/3/26: Please see notes from 1st disapproved Wall Sheathing inspection on 2/27/26: 2/27/26: 1). Wall sheathing is incomplete at face wall above entry where flashing will be installed. FBC [A]107.4 Inspector Notes from Inspection 2465 *** NOTES ADDED BY RSIMS 2/27/2026 11:54:13 AM *** 2/27/26: 1). At 2-ply Truss T01 > install a2ft. minimum length of 2" x 4" parallel to truss directly under the hole in the sheathing. FBC [A]107.4 *** NOTES ADDED BY RSIMS 2/27/2026 11:52:13 AM *** 2/27/26: 1). Wall sheathing is incomplete at face wall above entry where flashing will be installed. FBC [A]107.4 Inspector Notes from Inspection 2340 *** NOTES ADDED BY RSIMS 2/18/2026 12:05:36 PM *** 2/18/26: 1). Need dumpster on site and piles of trash and debris cleaned up to make site safe for inspections, etc. FBC 3302.2 / FBC-[A] 101.3 Inspector Notes from Inspection 2250 2/11/26 The sides show signs of possible cave in. At time of inspection, everything was good and proper clearance was visible. Please check before pouring for proper clearance and any wash-in/cave-in
WALL SHEATHING 03/03/2026 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 3/3/2026 2:22:24 PM *** 3/3/26: Please see notes from 1st disapproved Wall Sheathing inspection on 2/27/26: 2/27/26: 1). Wall sheathing is incomplete at face wall above entry where flashing will be installed. FBC [A]107.4 Inspector Notes from Inspection 2465 *** NOTES ADDED BY RSIMS 2/27/2026 11:54:13 AM *** 2/27/26: 1). At 2-ply Truss T01 > install a2ft. minimum length of 2" x 4" parallel to truss directly under the hole in the sheathing. FBC [A]107.4 *** NOTES ADDED BY RSIMS 2/27/2026 11:52:13 AM *** 2/27/26: 1). Wall sheathing is incomplete at face wall above entry where flashing will be installed. FBC [A]107.4 Inspector Notes from Inspection 2340 *** NOTES ADDED BY RSIMS 2/18/2026 12:05:36 PM *** 2/18/26: 1). Need dumpster on site and piles of trash and debris cleaned up to make site safe for inspections, etc. FBC 3302.2 / FBC-[A] 101.3 Inspector Notes from Inspection 2250 2/11/26 The sides show signs of possible cave in. At time of inspection, everything was good and proper clearance was visible. Please check before pouring for proper clearance and any wash-in/cave-in
WALL SHEATHING 02/27/2026 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 2/27/2026 11:52:13 AM *** 2/27/26: 1). Wall sheathing is incomplete at face wall above entry where flashing will be installed. FBC [A]107.4 Inspector Notes from Inspection 2340 *** NOTES ADDED BY RSIMS 2/18/2026 12:05:36 PM *** 2/18/26: 1). Need dumpster on site and piles of trash and debris cleaned up to make site safe for inspections, etc. FBC 3302.2 / FBC-[A] 101.3 Inspector Notes from Inspection 2250 2/11/26 The sides show signs of possible cave in. At time of inspection, everything was good and proper clearance was visible. Please check before pouring for proper clearance and any wash-in/cave-in
ROOF SHEATHING 02/27/2026 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 2/27/2026 11:54:13 AM *** 2/27/26: 1). At 2-ply Truss T01 > install a2ft. minimum length of 2" x 4" parallel to truss directly under the hole in the sheathing. FBC [A]107.4 Inspector Notes from Inspection 2340 *** NOTES ADDED BY RSIMS 2/18/2026 12:05:36 PM *** 2/18/26: 1). Need dumpster on site and piles of trash and debris cleaned up to make site safe for inspections, etc. FBC 3302.2 / FBC-[A] 101.3 Inspector Notes from Inspection 2250 2/11/26 The sides show signs of possible cave in. At time of inspection, everything was good and proper clearance was visible. Please check before pouring for proper clearance and any wash-in/cave-in
TIE BEAM / LINTEL 02/18/2026 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 2/18/2026 12:05:36 PM *** 2/18/26: 1). Need dumpster on site and piles of trash and debris cleaned up to make site safe for inspections, etc. FBC 3302.2 / FBC-[A] 101.3 Inspector Notes from Inspection 2250 2/11/26 The sides show signs of possible cave in. At time of inspection, everything was good and proper clearance was visible. Please check before pouring for proper clearance and any wash-in/cave-in
MONOLITHIC SLAB 02/11/2026 APPROVED - AS NOTED MCONTRYMAN
Note: 2/11/26 The sides show signs of possible cave in. At time of inspection, everything was good and proper clearance was visible. Please check before pouring for proper clearance and any wash-in/cave-in
PLUMBING 1ST ROUGH UNDERGROUND 02/03/2026 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 2/3/2026 2:42:26 PM ***
FORMBOARD SURVEY (OFFICE USE ONLY) 02/02/2026 APPROVED RRICKS
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 01/30/2026 APPROVED PKNAPIK
WATER METER INSTALLATION REQUEST 01/08/2026 APPROVED CBOWERMASTER
BLD - BUILDING FINAL
U-CROSS CONNECTION
ROW - FINAL APRON (AFTER POUR)
ROW- FINAL SURVEY/GRADING CERTIFICATION
ROW - FINAL INSPECTION
U -UTILITY RESIDENTIAL FINAL

Review History

Department Status Date In Date Out
MECH COMPLETE 05/15/2026 05/18/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 01/30/2026 02/02/2026
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 01/30/2026 01/30/2026
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD COMPLETE 01/29/2026 01/30/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
MECH COMPLETE 01/06/2026 01/07/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ZON COMPLETE 11/19/2025 11/19/2025
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
SW1 COMPLETE 11/13/2025 11/13/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
MECH COMPLETE 11/13/2025 11/18/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 COMPLETE 11/13/2025 11/14/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
ZON HOLD 11/13/2025 11/17/2025
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM add the porch dimension
MECH HOLD 11/07/2025 11/10/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Design location on heatload needs to be Daytona Beach
SW1 HOLD 11/07/2025 11/10/2025
Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM As noted from last review need to reshot elevations on the ffe of #11 to the left. The ffe doesn't match of what elevations on the site plan. from permited or COPC surveyors shot ffe at.
BLD CANCEL 11/07/2025 11/13/2025
ZON COMPLETE 11/07/2025 11/07/2025
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
SW1 HOLD 10/24/2025 10/24/2025
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Additional Grading Comments: - COPC Survey team confrimed an FFE of 27.75' on #11, which is incorrectly labeled on the grading plan submitted as #16. - Please revise as needed.
SWALE COMPLETE 10/14/2025 10/24/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
BLD COMPLETE 10/10/2025 10/17/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
CUSVC COMPLETE 10/10/2025 10/16/2025
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 10/10/2025 10/16/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 10/10/2025 10/14/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS CANCEL 10/10/2025 10/15/2025
LOCATE COMPLETE 10/10/2025 10/16/2025
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH HOLD 10/10/2025 10/15/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Direction house faces on Energy Calcs does not match the site plan. Revise to match per R405.4.2.1 FBC Energy Conservation 2023 8Th Edition
SW1 HOLD 10/10/2025 10/16/2025
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Grading comments: Please provide the edge of pavement elevations. Front property line must be even with or higher than edge of pavement.
ZON COMPLETE 10/10/2025 10/14/2025
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
CONTRACTOR CHANGE ¤20.00 06/04/2026
CONTRACTOR CHANGE ¤20.00 06/04/2026
PLAN REVIEW - REVISION ¤32.50 06/04/2026
PLAN REVIEW - REVISION ¤32.50 06/04/2026
REINSPECTION RESIDENTIAL ¤40.00 06/04/2026
REINSPECTION RESIDENTIAL ¤40.00 06/04/2026
REINSPECTION RESIDENTIAL ¤40.00 06/04/2026
REINSPECTION RESIDENTIAL ¤40.00 06/04/2026
REINSPECTION RESIDENTIAL ¤40.00 06/04/2026
CONTRACTOR CHANGE ¤20.00 12/03/2025
WATER- TURN ON ¤50.00 12/03/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 12/03/2025
INSPECTION - RESIDENTIAL ¤805.75 12/03/2025
PLAN REVIEW - RESIDENTIAL ¤228.54 12/03/2025
FC IMPACT FEE EMS ¤62.00 12/03/2025
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 12/03/2025
FC IMPACT FEE LIBRARY ¤268.00 12/03/2025
FIRE RES IMPACT FEE 10-25 ¤942.00 12/03/2025
PEP TANK INSTALL ¤756.74 12/03/2025
PARKS IMPACT FEE 10-25 ¤3,164.00 12/03/2025
RSI DRIVEWAY AFTER POUR ¤16.25 12/03/2025
RSE DRIVE PRE POUR INSPECTION ¤32.50 12/03/2025
RSI FIELD SURVEY INSPECTION ¤48.75 12/03/2025
RSI FORMBOARD REVIEW ¤16.25 12/03/2025
RSI PLAN REVIEW NEW ¤48.75 12/03/2025
RSI FNL SURVEY/GRADING CERT ¤48.75 12/03/2025
RSI ROW FINAL INSPECTION ¤16.25 12/03/2025
SCHOOL BOARD IMPACT FEE RES ¤5,450.00 12/03/2025
WASTEWATER MAIN EXTENSION IMPA ¤2,385.00 12/03/2025
SURCHARGE FS 533.721 ¤10.64 12/03/2025
SURCHARGE - FS 468.631 ¤15.96 12/03/2025
SW ENG RES REVIEW 240 ¤240.00 12/03/2025
WATER METER W/ TAP ¤2,326.93 12/03/2025
TRANSP RES IMPACT FEE 10-25 ¤5,670.08 12/03/2025
SEWER CREDIT (¤2,255.01) 12/03/2025
WASTEWATER PERM INSPECTION ¤80.00 12/03/2025
WASTEWATER PERM REVIEW ¤25.00 12/03/2025
SEWER CAPITAL FACILITY ¤4,415.00 12/03/2025
WATER CREDIT (¤183.92) 12/03/2025
WATER CAPITAL FACILITY FEE ¤3,790.49 12/03/2025
WATER PERMIT REVIEW ¤25.00 12/03/2025
WATER MAIN EXTENSION IMPACT ¤917.27 12/03/2025
SITE PLAN 30 ¤30.00 12/03/2025
Fees Total Due: ¤0.00 Total Paid: ¤30,019.97