Permit #2025100466

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7013-00240-0510
Total Square Footage: 627 sqft
Block: 00240
Subdivision: -
Job Phone: 410-984-6789
Location Address: 80 BRONSON LN
Type: PO - POOL
Issue Date: 10/20/2025
NOC: RECORDED
Applicant name: MICHAEL JON HOWES
Owner: SCHEFFLER REBECCA PRZEKOPSKI

Address

80 BRONSON LANE

PALM COAST, FL 32137

Lot: 0510
Contracted Stated Job Value: ¤52,000.00
Job Description: POOL W/EXISTING FENCE
Type: CN

Contractor

JIFFY SERVICES LLC
Status Location Address State License Number Phone
ACTIVE

29 MALACOMPRA ROAD

BUNNELL, FL 32137

RP252555617 (Exp: 08/31/2027) 410-984-6789

Sub Contractors

MICHAEL JON HOWES
Status Location Address State License Number Phone
ACTIVE

29 MALACOMPRA ROAD

BUNNELL, FL 32137

RP252555617 (Exp: 08/31/2027) 410-984-6789
MARK E SMITH
Status Location Address State License Number Phone Fax
ACTIVE

P. O. Box 351482

PALM COAST, FL 32164

EC0002128 (Exp: 08/31/2026) (386) 437-8496 386-586-3612

Inspection History

Type Request Date Result Inspector
ROW - FINAL INSPECTION 04/03/2026 APPROVED PBUCKLEY
Note: 4/1/2026 - PREVIOUS INSPECTION NOTES ** 04/01/26 NEED TO REMOVE THE PILE OF MATERIAL ALONG THE LEFT SIDE OUTSIDE OF THE FENCE ** BARE EARTH BEHIND FENCE NEEDS STABILIZATION TO PREVENT EROSION _________________________________________________________________________________________________________________________ 1/13/2026 - PREVIOUS INSPECTION NOTES ** 01/13/26 AS INDICATED BY HOMEOWNER TO MYSELF AND RSI SUPERVISOR G. BERTOLA ONE PREVIOUS PROJECT STATUS WITH HOMEOWNER HE WOULD BE FINISHING THE STONE WORK IN REAR YARD AREA WHERE BARE EARTH IS EXPOSED. THIS WORK MUST BE COMPLETED BEFORE THE ROW STORMWATER FINAL CAN BE APPROVED. ____________________________________________________________________________________________________________________________ 1/12/2026 - PREVIOUS INSPECTION NOTES ** 01/12/26 BUILDER CANCELLED TODAYS INSPECTION CITING THAT THE HOMEOWNER IS REQUESTING A 24 HOUR NOTIFICATION BEFORE INSPECTION IS CONDUCTED INSPECTION WILL BE RE-SCHEDULED BY THE BUILDER FOR 01/13/25
ROW - FINAL INSPECTION 04/01/2026 Disapproved - NO FEE EMADISON
Note: ** 04/01/26 NEED TO REMOVE THE PILE OF MATERIAL ALONG THE LEFT SIDE OUTSIDE OF THE FENCE ** BARE EARTH BEHIND FENCE NEEDS STABILIZATION TO PREVENT EROSION _________________________________________________________________________________________________________________________ 1/13/2026 - PREVIOUS INSPECTION NOTES ** 01/13/26 AS INDICATED BY HOMEOWNER TO MYSELF AND RSI SUPERVISOR G. BERTOLA ONE PREVIOUS PROJECT STATUS WITH HOMEOWNER HE WOULD BE FINISHING THE STONE WORK IN REAR YARD AREA WHERE BARE EARTH IS EXPOSED. THIS WORK MUST BE COMPLETED BEFORE THE ROW STORMWATER FINAL CAN BE APPROVED. ____________________________________________________________________________________________________________________________ 1/12/2026 - PREVIOUS INSPECTION NOTES ** 01/12/26 BUILDER CANCELLED TODAYS INSPECTION CITING THAT THE HOMEOWNER IS REQUESTING A 24 HOUR NOTIFICATION BEFORE INSPECTION IS CONDUCTED INSPECTION WILL BE RE-SCHEDULED BY THE BUILDER FOR 01/13/25
POOL FINAL 03/30/2026 APPROVED PBUCKLEY
Note: 3/26/2026 - PREVIOUS INSPECTION NOTES 1/16/2026 4:27:26 PM- PREVIOUS INSPECTION NOTES 1. PREVIOUS POOL FINAL INSPECTION APPROVAL ON 01/13/26 OVERRIDDEN BY CHIEF BUILDING OFFICIAL. INSPECTION IS NOT APPROVED PER 2023 FLORIDA BUILDING CODE SECTION R318.7 BELOW. POOL DECK IS A PATIO. POOL DECK / PATIO EXCEEDS ELEVATION OF INTERIOR FINISH FLOOR ELEVATION OF HOME. PER EXCEPTION NO. 4. PATIOS ADJACENT TO MASONRY CONSTRUCTION, IF TREATED FOR TERMITES, MAY MATCH, BUT NOT EXCEED, THE FINISHED FLOOR ELEVATION OF THE HOME. THE POOL DECK / PATIO EXCEEDS THE FINISHED FLOOR ELEVATION OF THE HOME. R318.7 Inspection for termites. In order to provide for inspection for termite infestation, clearance between exterior wall coverings and final earth grade on the exterior of a building shall not be less than 6 inches (152 mm). Exceptions: l. Paint or decorative cementitious finish less than 5/8 inch (17.1 mm) thick adhered directly to the masonry foundation sidewall. 2. Access or vehicle ramps which rise to the interior finish floor elevation for the width of such ramps only. 3. A 4-inch (102 mm) inspection space above patio and garage slabs and entry areas. 4. If the patio has been soil treated for termites, the finish elevation may match the building interior finish floor elevations on masonry construction only. 5. Masonry veneers constructed in accordance with Section R318.4. 2. POOL DECK / PATIO EXCEEDS ELEVATION OF DOOR THRESHOLDS AT BATHROOM DOOR AND ENCLOSED LANAI DOOR AND IS A VIOLATION OF 2023 FLORIDA BUILDING CODE-RESIDENTIAL SECTION R311.3..2. THIS SECTION ALLOWS LANDINGS OR FLOORS UP TO 7-3/4 INCHES BELOW TOP OF DOOR THRESHOLD BUT DOES NOT PROVIDE ANY PROVISION ALLOWING FLOORS OR LANDINGS TO BE ABOVE THE TOP OF THE DOOR THRESHOLD. R311.3.2 Floor elevations for other exterior doors. Doors other than the required egress door shall be provided with landings or floors not more than 73/4 inches (196 mm) below the top of the threshold. Exception: A top landing is not required where a stairway of not more than two risers is located on the exterior side of the door.
POOL FINAL 03/26/2026 CANCELLED BY APPLICANT JSTEWART
Note: 1/16/2026 4:27:26 PM- PREVIOUS INSPECTION NOTES 1. PREVIOUS POOL FINAL INSPECTION APPROVAL ON 01/13/26 OVERRIDDEN BY CHIEF BUILDING OFFICIAL. INSPECTION IS NOT APPROVED PER 2023 FLORIDA BUILDING CODE SECTION R318.7 BELOW. POOL DECK IS A PATIO. POOL DECK / PATIO EXCEEDS ELEVATION OF INTERIOR FINISH FLOOR ELEVATION OF HOME. PER EXCEPTION NO. 4. PATIOS ADJACENT TO MASONRY CONSTRUCTION, IF TREATED FOR TERMITES, MAY MATCH, BUT NOT EXCEED, THE FINISHED FLOOR ELEVATION OF THE HOME. THE POOL DECK / PATIO EXCEEDS THE FINISHED FLOOR ELEVATION OF THE HOME. R318.7 Inspection for termites. In order to provide for inspection for termite infestation, clearance between exterior wall coverings and final earth grade on the exterior of a building shall not be less than 6 inches (152 mm). Exceptions: l. Paint or decorative cementitious finish less than 5/8 inch (17.1 mm) thick adhered directly to the masonry foundation sidewall. 2. Access or vehicle ramps which rise to the interior finish floor elevation for the width of such ramps only. 3. A 4-inch (102 mm) inspection space above patio and garage slabs and entry areas. 4. If the patio has been soil treated for termites, the finish elevation may match the building interior finish floor elevations on masonry construction only. 5. Masonry veneers constructed in accordance with Section R318.4. 2. POOL DECK / PATIO EXCEEDS ELEVATION OF DOOR THRESHOLDS AT BATHROOM DOOR AND ENCLOSED LANAI DOOR AND IS A VIOLATION OF 2023 FLORIDA BUILDING CODE-RESIDENTIAL SECTION R311.3..2. THIS SECTION ALLOWS LANDINGS OR FLOORS UP TO 7-3/4 INCHES BELOW TOP OF DOOR THRESHOLD BUT DOES NOT PROVIDE ANY PROVISION ALLOWING FLOORS OR LANDINGS TO BE ABOVE THE TOP OF THE DOOR THRESHOLD. R311.3.2 Floor elevations for other exterior doors. Doors other than the required egress door shall be provided with landings or floors not more than 73/4 inches (196 mm) below the top of the threshold. Exception: A top landing is not required where a stairway of not more than two risers is located on the exterior side of the door.
POOL FINAL 01/16/2026 Disapproved - NO FEE PBUCKLEY
Note: 1. PREVIOUS POOL FINAL INSPECTION APPROVAL ON 01/13/26 OVERRIDDEN BY CHIEF BUILDING OFFICIAL. INSPECTION IS NOT APPROVED PER 2023 FLORIDA BUILDING CODE SECTION R318.7 BELOW. POOL DECK IS A PATIO. POOL DECK / PATIO EXCEEDS ELEVATION OF INTERIOR FINISH FLOOR ELEVATION OF HOME. PER EXCEPTION NO. 4. PATIOS ADJACENT TO MASONRY CONSTRUCTION, IF TREATED FOR TERMITES, MAY MATCH, BUT NOT EXCEED, THE FINISHED FLOOR ELEVATION OF THE HOME. THE POOL DECK / PATIO EXCEEDS THE FINISHED FLOOR ELEVATION OF THE HOME. R318.7 Inspection for termites. In order to provide for inspection for termite infestation, clearance between exterior wall coverings and final earth grade on the exterior of a building shall not be less than 6 inches (152 mm). Exceptions: l. Paint or decorative cementitious finish less than 5/8 inch (17.1 mm) thick adhered directly to the masonry foundation sidewall. 2. Access or vehicle ramps which rise to the interior finish floor elevation for the width of such ramps only. 3. A 4-inch (102 mm) inspection space above patio and garage slabs and entry areas. 4. If the patio has been soil treated for termites, the finish elevation may match the building interior finish floor elevations on masonry construction only. 5. Masonry veneers constructed in accordance with Section R318.4. 2. POOL DECK / PATIO EXCEEDS ELEVATION OF DOOR THRESHOLDS AT BATHROOM DOOR AND ENCLOSED LANAI DOOR AND IS A VIOLATION OF 2023 FLORIDA BUILDING CODE-RESIDENTIAL SECTION R311.3..2. THIS SECTION ALLOWS LANDINGS OR FLOORS UP TO 7-3/4 INCHES BELOW TOP OF DOOR THRESHOLD BUT DOES NOT PROVIDE ANY PROVISION ALLOWING FLOORS OR LANDINGS TO BE ABOVE THE TOP OF THE DOOR THRESHOLD. R311.3.2 Floor elevations for other exterior doors. Doors other than the required egress door shall be provided with landings or floors not more than 73/4 inches (196 mm) below the top of the threshold. Exception: A top landing is not required where a stairway of not more than two risers is located on the exterior side of the door.
POOL FINAL 01/13/2026 FINAL APPROVED MCONTRYMAN
ROW - FINAL INSPECTION 01/13/2026 Disapproved - NO FEE EMADISON
Note: ** 01/13/26 AS INDICATED BY HOMEOWNER TO MYSELF AND RSI SUPERVISOR G. BERTOLA ONE PREVIOUS PROJECT STATUS WITH HOMEOWNER HE WOULD BE FINISHING THE STONE WORK IN REAR YARD AREA WHERE BARE EARTH IS EXPOSED. THIS WORK MUST BE COMPLETED BEFORE THE ROW STORMWATER FINAL CAN BE APPROVED. ____________________________________________________________________________________________________________________________ 1/12/2026 - PREVIOUS INSPECTION NOTES ** 01/12/26 BUILDER CANCELLED TODAYS INSPECTION CITING THAT THE HOMEOWNER IS REQUESTING A 24 HOUR NOTIFICATION BEFORE INSPECTION IS CONDUCTED INSPECTION WILL BE RE-SCHEDULED BY THE BUILDER FOR 01/13/25
ROW - FINAL INSPECTION 01/12/2026 CANCELLED BY APPLICANT EMADISON
Note: ** 01/12/26 BUILDER CANCELLED TODAYS INSPECTION CITING THAT THE HOMEOWNER IS REQUESTING A 24 HOUR NOTIFICATION BEFORE INSPECTION IS CONDUCTED INSPECTION WILL BE RE-SCHEDULED BY THE BUILDER FOR 01/13/25
U -UTILITY RESIDENTIAL FINAL 01/12/2026 FINAL APPROVED BWRIGHT
ROW- FINAL SURVEY/GRADING CERTIFICATION 01/08/2026 APPROVED EMADISON
Note: ** 01/08/25 MET HOMEOWNER ON SITE WITH RSI SUPERVISOR G. BERTOLA CHECK DRAINAGE BEFORE APPROVING. ** THE FINAL SURVEY DOES NOT MATCH THE FIELD CONDITIONS ** THE DRAINAGE WILL WORK AND NOT HAVE A NEGATIVE IMPACT ON ANY ADJACENT IMPROVED PROPERTY. ____________________________________________________________________________________________________________________________ 12-19-25 TPOLACEK*** IN ADDITION TO BUILDING OFFICIALS NOTES PLEASE CALL BUILDER BEFORE FIELD SURVEY IS CONDUCTED AS HOME OWNER REQUESTS 24 HOUR NOTICE FOR INSPECTION 12/19/2025 - PREVIOUS INSPECTION NOTES 12-19-25 TPOLACEK*** SPOKE WITH BUILDER ABOUT FINAL SURVEY AND THEY REQUESTED I CANCEL INSPECTION FOR TODAY . 11/21/2025 - PREVIOUS INSPECTION NOTES 11-21-25 TPOLACEK*** FINAL SURVEY IS REQUIRED TO SHOW ALL DRAINAGE CONVEYANCES, THERE NEEDS TO BE MORE SHOTS ACROSS THE REAR TO SHOW DRAINAGE WILL NOT IMPACT ADJOINING PROPERTY IN THE REAR. RIGHT SIDE PROPERTY DOES NOT HAVE POSITIVE FALL OUOT TO THE FRONT SWALE AS APPROVED SITE PLAN INDICATES, LEFT SIDE PROPERTY IN THE FRONT IS FLAT AND DRAINAGE WILL NOT FLOW. PLEASE SEE ATTACHED PHOTO WITH EXPLANATIONS 11/20/2025 - PREVIOUS INSPECTION NOTES ** 11/20/25 BUILDER IS REQUIRED TO SUBMIT A NEW FINAL SURVEY THAT IS LEGIBLE MANY OF YOUR ELEVATION SHOTS ARE OBSCURED MAKING IT DIFFICULT TO ASSERTAIN YOUR DRAINAGE PATTERN
ROW FIELD SURVEY /GRADING CERTIFICATION 01/08/2026 APPROVED EMADISON
Note: ** 01/08/25 MET HOMEOWNER ON SITE WITH RSI SUPERVISOR G. BERTOLA CHECK DRAINAGE BEFORE APPROVING. ** THE FINAL SURVEY DOES NOT MATCH THE FIELD CONDITIONS ** THE DRAINAGE WILL WORK AND NOT HAVE A NEGATIVE IMPACT ON ANY ADJACENT IMPROVED PROPERTY. ____________________________________________________________________________________________________________________________ 12-19-25 TPOLACEK*** IN ADDITION TO BUILDING OFFICIALS NOTES PLEASE CALL BUILDER BEFORE FIELD SURVEY IS CONDUCTED AS HOME OWNER REQUESTS 24 HOUR NOTICE FOR INSPECTION
ROW- PROJECT STATUS 01/08/2026 Status Check EMADISON
Note: Note to the Inspectors. Please Contatc the homeowner at 860-383-3006 Carl and coordinate the meeting with him ** 01/08/25 MET HOMEOWNER ON SITE WITH RSI SUPERVISOR G. BERTOLA CHECK DRAINAGE
ROW- FINAL SURVEY/GRADING CERTIFICATION 12/19/2025 CANCELLED BY APPLICANT TPOLACEK
Note: 12-19-25 TPOLACEK*** SPOKE WITH BUILDER ABOUT FINAL SURVEY AND THEY REQUESTED I CANCEL INSPECTION FOR TODAY . 11/21/2025 - PREVIOUS INSPECTION NOTES 11-21-25 TPOLACEK*** FINAL SURVEY IS REQUIRED TO SHOW ALL DRAINAGE CONVEYANCES, THERE NEEDS TO BE MORE SHOTS ACROSS THE REAR TO SHOW DRAINAGE WILL NOT IMPACT ADJOINING PROPERTY IN THE REAR. RIGHT SIDE PROPERTY DOES NOT HAVE POSITIVE FALL OUOT TO THE FRONT SWALE AS APPROVED SITE PLAN INDICATES, LEFT SIDE PROPERTY IN THE FRONT IS FLAT AND DRAINAGE WILL NOT FLOW. PLEASE SEE ATTACHED PHOTO WITH EXPLANATIONS 11/20/2025 - PREVIOUS INSPECTION NOTES ** 11/20/25 BUILDER IS REQUIRED TO SUBMIT A NEW FINAL SURVEY THAT IS LEGIBLE MANY OF YOUR ELEVATION SHOTS ARE OBSCURED MAKING IT DIFFICULT TO ASSERTAIN YOUR DRAINAGE PATTERN
STEEL AND GROUND 12/18/2025 APPROVED - AS NOTED MCONTRYMAN
Note: 12/18/25 Ground wire was seen properly bonded to the pool/water feature, which was fed up through under the pool deck pavers. It was trenched around the side and back of the pool and properly bonded to pool equipment and pool ground, for a continuous ground Inspector Notes from Inspection 2600 This inspection was for the bonding and continuity test for the equipment and metal parts of the pool/water feature. I Met the Pool Contractor and licensed Electrical Contractor on site to conduct the test. The Continuity test passed inspection.
ROW- PROJECT STATUS 12/08/2025 Status Check TPOLACEK
Note: 12-8-25 TPOLACEK*** AT THE TIME OF THIS PROJECT STATUS INSOECTION THE HOT PATCH IS GOOD. THERE DSI A SMALL AMOUNT OF LOOSE STONES ON TOP BUT PATCH IS COMPACTED. SOD IS CUT IN TO GRADE AND MEETS COPC REQUIREMENTS AT THIS TIME. PLEASE CHECK STATUS OF HOT PATCH AND SOD IN ROW
STEEL AND GROUND 12/03/2025 APPROVED - AS NOTED RMARTIN
Note: This inspection was for the bonding and continuity test for the equipment and metal parts of the pool/water feature. I Met the Pool Contractor and licensed Electrical Contractor on site to conduct the test. The Continuity test passed inspection.
STEEL AND GROUND 12/01/2025 CANCELLED BY APPLICANT RMARTIN
ROW- FINAL SURVEY/GRADING CERTIFICATION 11/21/2025 Disapproved - NO FEE TPOLACEK
Note: 11-21-25 TPOLACEK*** FINAL SURVEY IS REQUIRED TO SHOW ALL DRAINAGE CONVEYANCES, THERE NEEDS TO BE MORE SHOTS ACROSS THE REAR TO SHOW DRAINAGE WILL NOT IMPACT ADJOINING PROPERTY IN THE REAR. RIGHT SIDE PROPERTY DOES NOT HAVE POSITIVE FALL OUOT TO THE FRONT SWALE AS APPROVED SITE PLAN INDICATES, LEFT SIDE PROPERTY IN THE FRONT IS FLAT AND DRAINAGE WILL NOT FLOW. PLEASE SEE ATTACHED PHOTO WITH EXPLANATIONS 11/20/2025 - PREVIOUS INSPECTION NOTES ** 11/20/25 BUILDER IS REQUIRED TO SUBMIT A NEW FINAL SURVEY THAT IS LEGIBLE MANY OF YOUR ELEVATION SHOTS ARE OBSCURED MAKING IT DIFFICULT TO ASSERTAIN YOUR DRAINAGE PATTERN
ROW- FINAL SURVEY/GRADING CERTIFICATION 11/20/2025 Disapproved - NO FEE EMADISON
Note: ** 11/20/25 BUILDER IS REQUIRED TO SUBMIT A NEW FINAL SURVEY THAT IS LEGIBLE MANY OF YOUR ELEVATION SHOTS ARE OBSCURED MAKING IT DIFFICULT TO ASSERTAIN YOUR DRAINAGE PATTERN
POOL DECK 11/19/2025 APPROVED MCONTRYMAN
ELECTRIC AND ALARM 11/19/2025 APPROVED MCONTRYMAN
STEEL AND GROUND 10/29/2025 APPROVED FWILLIS
SUBGRADE - FIBERGLASS POOL 10/23/2025 CANCELLED BY APPLICANT WEB
Note: 10/21/2025 - PREVIOUS INSPECTION NOTES Still digging. Subgrade to be installed by 10/22/25 in the afternoon
SUBGRADE - FIBERGLASS POOL 10/22/2025 APPROVED FWILLIS
Note: New inspection due to canceled inspection 10/21/2025 - PREVIOUS INSPECTION NOTES Still digging. Subgrade to be installed by 10/22/25 in the afternoon
SUBGRADE - FIBERGLASS POOL 10/21/2025 CANCELLED BY APPLICANT MCONTRYMAN
Note: Still digging. Subgrade to be installed by 10/22/25 in the afternoon

Review History

Department Status Date In Date Out
BADMIN INFORMATION 12/16/2025 12/16/2025
Note: Marked INFORMATION By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM Not able to process final survey there is a inspection scheduled 12/18.
BADMIN INFORMATION 11/19/2025 11/19/2025
Note: Marked INFORMATION By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM Unable to result final survey because the one of the inspections today is not resulted yet. Please wait until that inspection is resulted to upload final survey.
BADMIN INFORMATION 11/18/2025 11/18/2025
Note: Marked INFORMATION By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM Unable to process final survey because there are prior inspections needed. Please resubmit final survey after prior inspections are passed.
BFLOOD CANCEL 10/15/2025 10/16/2025
BLD COMPLETE 10/15/2025 10/20/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ELEC COMPLETE 10/15/2025 10/20/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 10/15/2025 10/16/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
RSI COMPLETE 10/15/2025 10/16/2025
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM DRAINAGE MUST MEET ALL CITY OF PALM COAST STANDARDS
ZON COMPLETE 10/15/2025 10/15/2025
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
CONTRACTOR CHANGE ¤20.00 10/27/2025
RSI FIELD SURVEY INSPECTION ¤48.75 10/20/2025
RSI PLAN REVIEW NEW ¤48.75 10/20/2025
RSI FNL SURVEY/GRADING CERT ¤48.75 10/20/2025
RSI ROW FINAL INSPECTION ¤16.25 10/20/2025
SURCHARGE FS 533.721 ¤2.55 10/20/2025
SURCHARGE - FS 468.631 ¤3.83 10/20/2025
SITE PLAN 30 ¤30.00 10/20/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 10/20/2025
INSPECTION- POOL ¤160.00 10/20/2025
PLAN REVIEW - RESIDENTIAL ¤65.00 10/20/2025
Fees Total Due: ¤0.00 Total Paid: ¤473.88