Permit #2025100500

Permit Details

Status: INSPECT

Parcel Id: 07-11-31-7037-01260-0050
GARAGE: 759 sqft
OPENED PORCH (WITH ROOF) : 249 sqft
CONDITIONED SPACE: 1873 sqft
Total Square Footage: 2881 sqft
Block: 01260
Subdivision: -
Job Phone: 352-433-8382
Location Address: 3 LONGVIEW LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 11/10/2025
NOC: RECORDED
Applicant name: ALFREDO E SCHEER
Owner: IGLESIAS MARINA LIFE ESTATE

Address

520 SOUTHWEST 79TH COURT

MIAMI, FL 33144

Lot: 0050
Contracted Stated Job Value: ¤165,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

ESTELA LIVING LLC
Status Location Address State License Number Phone
ACTIVE

237 S. DIXIE HWY, 4TH FLOOR

CORAL GABLES, FL 33133

CGC1534535 (Exp: 08/31/2026) 352-433-8382

Sub Contractors

DUSTIN L ESTEP
Status Location Address State License Number Phone Fax
ACTIVE

2041 N HIAWASSEE RD

APOPKA, FL 32703

CCC1330971 (Exp: 08/31/2026) 407-702-0206 352-988-6629
JOSEPH HORATIO STRADA JR
Status Location Address State License Number Phone
ACTIVE

3400 ST JOHNS PARKWAY

SANFORD, FL 32771

EC13003715 (Exp: 08/31/2026) 877-906-1113
JOSEPH H STRADA JR
Status Location Address State License Number Phone
ACTIVE

3400 ST JOHNS PKWY

SANFORD, FL 32771

CAC043953 (Exp: 08/31/2026) 877-906-1113
JUAN CARLOS GONZALEZ
Status Location Address State License Number
ACTIVE

1328 COUNTY ROAD 308

CRESCENT CITY, FL 32112

RF11067806 (Exp: 08/31/2027)

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 06/10/2026 Disapproved - NO FEE JSTEWART
Note: 1. Tighten Multiple anchors at garage door bucks. per plan 2. Lower garage door saftey devices max 8" off floor. UL 325 3. Seal water heater Power penetration into CMU wall. R302.5 4. Post termite plaque. FBC 105.11 5. Seal wall penetration in AHU closet (liquid lines). FBC R302.11(4) 6. Spare bath exhaust fan missing cover. per plan/ manufacturer. Inspector Notes from Inspection 2490 If SGD panels are not installed prior to hanging drywall, Please block opening with plastic for inclement weather. 3/19/2026 - PREVIOUS INSPECTION NOTES Cannot use standard gap foam for annular penetrations at dryer vent, ac cabinet, and thermostat wire. Still missing energy calcs and product approvals. Inspector Notes from Inspection 2420 3/12/26 1. No product approvals on site FBC(A) 107.3.1 2. No energy calcs on site FBC(A) 107.3.1 --Must have on site for next inspection to avoid failures and fees
ROW- PRE-APRON (PRE-POUR) 05/12/2026 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. WOOD CONTROL JOINTS ARE PROHIBITED IN THE RIGHT-OF-WAY. SAWCUT SHALL BE PROVIDED AT THE EDGE OF ROW AND EVERY 12' THEREAFTER, OR A MINIMUM OF 2 SAWCUTS WHICHEVER IS GREATER" 5/11/2026 - PREVIOUS INSPECTION NOTES RECIEVED CALL FROM JIM THE CM ASKING TO PLEASE CANCEL INSPECTION AS DRIVEWAY WAS NOT RAILED UP YET
ROW- PRE-APRON (PRE-POUR) 05/11/2026 CANCELLED BY APPLICANT TPOLACEK
Note: RECIEVED CALL FROM JIM THE CM ASKING TO PLEASE CANCEL INSPECTION AS DRIVEWAY WAS NOT RAILED UP YET
ELECTRIC - EARLY POWER 05/05/2026 APPROVED - AS NOTED JSTEWART
Note: Authorize release of email.
GRAVITY SEWER TEST 04/21/2026 APPROVED KSANDOE
Note: 4/17/2026 - PREVIOUS INSPECTION NOTES re inspection, after sewer tie in is repaired.
SEWER TIE IN 04/21/2026 APPROVED KSANDOE
Note: 4/17/2026 - PREVIOUS INSPECTION NOTES Cleanout and wye is required by the City of Palm coast to be WITHIN 3ft of the sewer connection to Pep tank, currently 5ft+.
GRAVITY SEWER TEST 04/17/2026 Disapproved - NO FEE JSTEWART
Note: re inspection, after sewer tie in is repaired.
SEWER TIE IN 04/17/2026 Disapproved - NO FEE JSTEWART
Note: Cleanout and wye is required by the City of Palm coast to be WITHIN 3ft of the sewer connection to Pep tank, currently 5ft+.
PEP TANK INSTALLATION REQUEST 04/01/2026 APPROVED ISANDERSON
Note: 3/25/2026 12:37:33 PM- PREVIOUS INSPECTION NOTES Dumpster in the way
PEP TANK INSTALLATION REQUEST 03/25/2026 Disapproved - NO FEE ISANDERSON
Note: Dumpster in the way
INSULATION 03/23/2026 APPROVED - AS NOTED JSTEWART
Note: If SGD panels are not installed prior to hanging drywall, Please block opening with plastic for inclement weather. 3/19/2026 - PREVIOUS INSPECTION NOTES Cannot use standard gap foam for annular penetrations at dryer vent, ac cabinet, and thermostat wire. Still missing energy calcs and product approvals. Inspector Notes from Inspection 2420 3/12/26 1. No product approvals on site FBC(A) 107.3.1 2. No energy calcs on site FBC(A) 107.3.1 --Must have on site for next inspection to avoid failures and fees
INSULATION 03/19/2026 Disapproved - NO FEE KSANDOE
Note: Cannot use standard gap foam for annular penetrations at dryer vent, ac cabinet, and thermostat wire. Still missing energy calcs and product approvals. Inspector Notes from Inspection 2420 3/12/26 1. No product approvals on site FBC(A) 107.3.1 2. No energy calcs on site FBC(A) 107.3.1 --Must have on site for next inspection to avoid failures and fees
ALL ROUGH 03/12/2026 APPROVED - AS NOTED MCONTRYMAN
Note: 3/12/26 1. No product approvals on site FBC(A) 107.3.1 2. No energy calcs on site FBC(A) 107.3.1 --Must have on site for next inspection to avoid failures and fees
LATH/BRICK/ WATER BARRIER 03/11/2026 APPROVED KSANDOE
WALL SHEATHING 03/03/2026 APPROVED JSTEWART
WATER METER INSTALLATION REQUEST 03/03/2026 APPROVED ISANDERSON
ROOF VALLEY & METAL 02/24/2026 APPROVED KSANDOE
ROOF SHEATHING / BRACES/TIES/DOWN CELL 02/19/2026 APPROVED CVANSTRAHLEN
TIE BEAM / LINTEL 02/12/2026 APPROVED JSTEWART
Note: 2/11/2026 - PREVIOUS INSPECTION NOTES Repairs have not been made 2/10/2026 - PREVIOUS INSPECTION NOTES Missing footing dowel for left side of left bathroom window. drop dowel is installed but not tied to a footing dowel.
TIE BEAM / LINTEL 02/11/2026 Disapproved -FEE REQUIRED KSANDOE
Note: Repairs have not been made 2/10/2026 - PREVIOUS INSPECTION NOTES Missing footing dowel for left side of left bathroom window. drop dowel is installed but not tied to a footing dowel.
TIE BEAM / LINTEL 02/10/2026 Disapproved - NO FEE JSTEWART
Note: Missing footing dowel for left side of left bathroom window. drop dowel is installed but not tied to a footing dowel.
MONOLITHIC SLAB 02/02/2026 Disapproved - NO FEE JSTEWART
Note: FBC [A] 105.11 NOTICE OF TERMITE INSPECTION
MONOLITHIC SLAB 02/02/2026 APPROVED JSTEWART
Note: Live virtual re inspection, correction completed. 2/2/2026 - PREVIOUS INSPECTION NOTES FBC [A] 105.11 NOTICE OF TERMITE INSPECTION
PLUMBING 1ST ROUGH UNDERGROUND 01/29/2026 Disapproved - NO FEE MKRASKI
Note: 1. No plumbing riser diagram onsite, please have a full set of plans on site for inspection with Building Dept. stamp of approval FBC 107.3.1
PLUMBING 1ST ROUGH UNDERGROUND 01/29/2026 APPROVED MKRASKI
FORMBOARD SURVEY (OFFICE USE ONLY) 01/27/2026 APPROVED RRICKS
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 01/27/2026 APPROVED PKNAPIK
BLD - BUILDING FINAL
Note: 6/10/2026 - PREVIOUS INSPECTION NOTES 1. Tighten Multiple anchors at garage door bucks. per plan 2. Lower garage door saftey devices max 8" off floor. UL 325 3. Seal water heater Power penetration into CMU wall. R302.5 4. Post termite plaque. FBC 105.11 5. Seal wall penetration in AHU closet (liquid lines). FBC R302.11(4) 6. Spare bath exhaust fan missing cover. per plan/ manufacturer. Inspector Notes from Inspection 2490 If SGD panels are not installed prior to hanging drywall, Please block opening with plastic for inclement weather. 3/19/2026 - PREVIOUS INSPECTION NOTES Cannot use standard gap foam for annular penetrations at dryer vent, ac cabinet, and thermostat wire. Still missing energy calcs and product approvals. Inspector Notes from Inspection 2420 3/12/26 1. No product approvals on site FBC(A) 107.3.1 2. No energy calcs on site FBC(A) 107.3.1 --Must have on site for next inspection to avoid failures and fees
U-CROSS CONNECTION
ROW - FINAL APRON (AFTER POUR)
ROW- FINAL SURVEY/GRADING CERTIFICATION
ROW - FINAL INSPECTION
U -UTILITY RESIDENTIAL FINAL

Review History

Department Status Date In Date Out
BLD COMPLETE 03/13/2026 03/18/2026
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 01/27/2026 01/27/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
SW1 COMPLETE 01/27/2026 01/27/2026
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 01/27/2026 01/27/2026
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD COMPLETE 01/23/2026 01/26/2026
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 10/28/2025 10/29/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 10/28/2025 11/03/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BADMIN INFORMATION 10/27/2025 10/27/2025
Note: Marked INFORMATION By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM 1. SELECT 'PLANS' FROM DROPDOWN MENU, NOT TRUSS PLANS 2. RENAME TO ENERGY CALCS.PDF
BLD HOLD 10/22/2025 10/24/2025
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Truss packet or truss layout needs shop drawing approval stamp by engineer of record.
BLD HOLD 10/15/2025 10/21/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Complete truss plan packet cover sheet or first page to include the design professional of record (building design engineer or architect) approval stamp indicating acceptance and approval of truss design (Not wet seal)
CUSVC COMPLETE 10/15/2025 10/21/2025
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 10/15/2025 10/20/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 10/15/2025 10/15/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS CANCEL 10/15/2025 10/16/2025
LOCATE COMPLETE 10/15/2025 10/17/2025
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH HOLD 10/15/2025 10/20/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Indoor design temp on heatload must be a minimum of 75 degrees per R302.1 FBC Energy Conservation 2023 8Th edition
SW1 COMPLETE 10/15/2025 10/20/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 10/15/2025 10/17/2025
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
SWALE COMPLETE 10/15/2025 11/24/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
FC IMPACT FEE EMS ¤62.00 11/10/2025
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 11/10/2025
FC IMPACT FEE LIBRARY ¤268.00 11/10/2025
FIRE RES IMPACT FEE 10-25 ¤942.00 11/10/2025
PEP TANK INSTALL ¤756.74 11/10/2025
PARKS IMPACT FEE 10-25 ¤3,164.00 11/10/2025
RSI DRIVEWAY AFTER POUR ¤16.25 11/10/2025
RSE DRIVE PRE POUR INSPECTION ¤32.50 11/10/2025
RSI FIELD SURVEY INSPECTION ¤48.75 11/10/2025
RSI FORMBOARD REVIEW ¤16.25 11/10/2025
RSI PLAN REVIEW NEW ¤48.75 11/10/2025
RSI FNL SURVEY/GRADING CERT ¤48.75 11/10/2025
RSI ROW FINAL INSPECTION ¤16.25 11/10/2025
SCHOOL BOARD IMPACT FEE RES ¤5,450.00 11/10/2025
WASTEWATER MAIN EXTENSION IMPA ¤2,385.00 11/10/2025
SURCHARGE FS 533.721 ¤14.10 11/10/2025
SURCHARGE - FS 468.631 ¤21.15 11/10/2025
SW ENG RES REVIEW 240 ¤240.00 11/10/2025
WATER METER W/ TAP ¤2,326.93 11/10/2025
TRANSP RES IMPACT FEE 10-25 ¤7,061.21 11/10/2025
SEWER CREDIT (¤1,342.00) 11/10/2025
WASTEWATER PERM INSPECTION ¤80.00 11/10/2025
WASTEWATER PERM REVIEW ¤25.00 11/10/2025
SEWER CAPITAL FACILITY ¤4,415.00 11/10/2025
WATER CAPITAL FACILITY FEE ¤3,790.49 11/10/2025
WATER PERMIT REVIEW ¤25.00 11/10/2025
WATER MAIN EXTENSION IMPACT ¤917.27 11/10/2025
SITE PLAN 30 ¤30.00 11/10/2025
WATER- TURN ON ¤50.00 11/10/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 11/10/2025
INSPECTION - RESIDENTIAL ¤1,075.25 11/10/2025
PLAN REVIEW - RESIDENTIAL ¤304.98 11/10/2025
REINSPECTION RESIDENTIAL ¤40.00
Fees Total Due: ¤40.00 Total Paid: ¤32,537.62