I want to search for...
Permit #2025100500
Permit Details
Status: INSPECT
| Parcel Id: 07-11-31-7037-01260-0050 |
| GARAGE: 759 sqft |
| OPENED PORCH (WITH ROOF) : 249 sqft |
| CONDITIONED SPACE: 1873 sqft |
| Total Square Footage: 2881 sqft |
| Block: 01260 |
| Subdivision: - |
| Job Phone: 352-433-8382 |
| Location Address: 3 LONGVIEW LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 11/10/2025 |
| NOC: RECORDED |
| Applicant name: ALFREDO E SCHEER |
| Owner: IGLESIAS MARINA LIFE ESTATE |
|
Address 520 SOUTHWEST 79TH COURT MIAMI, FL 33144 |
| Lot: 0050 |
| Contracted Stated Job Value: ¤165,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
ESTELA LIVING LLC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
237 S. DIXIE HWY, 4TH FLOOR CORAL GABLES, FL 33133 |
CGC1534535 (Exp: 08/31/2026) | 352-433-8382 |
Sub Contractors
DUSTIN L ESTEP
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2041 N HIAWASSEE RD APOPKA, FL 32703 |
CCC1330971 (Exp: 08/31/2026) | 407-702-0206 | 352-988-6629 |
JOSEPH HORATIO STRADA JR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3400 ST JOHNS PARKWAY SANFORD, FL 32771 |
EC13003715 (Exp: 08/31/2026) | 877-906-1113 |
JOSEPH H STRADA JR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3400 ST JOHNS PKWY SANFORD, FL 32771 |
CAC043953 (Exp: 08/31/2026) | 877-906-1113 |
JUAN CARLOS GONZALEZ
| Status | Location Address | State License Number |
| ACTIVE |
1328 COUNTY ROAD 308 CRESCENT CITY, FL 32112 |
RF11067806 (Exp: 08/31/2027) |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 06/10/2026 | Disapproved - NO FEE | JSTEWART |
| Note: 1. Tighten Multiple anchors at garage door bucks. per plan 2. Lower garage door saftey devices max 8" off floor. UL 325 3. Seal water heater Power penetration into CMU wall. R302.5 4. Post termite plaque. FBC 105.11 5. Seal wall penetration in AHU closet (liquid lines). FBC R302.11(4) 6. Spare bath exhaust fan missing cover. per plan/ manufacturer. Inspector Notes from Inspection 2490 If SGD panels are not installed prior to hanging drywall, Please block opening with plastic for inclement weather. 3/19/2026 - PREVIOUS INSPECTION NOTES Cannot use standard gap foam for annular penetrations at dryer vent, ac cabinet, and thermostat wire. Still missing energy calcs and product approvals. Inspector Notes from Inspection 2420 3/12/26 1. No product approvals on site FBC(A) 107.3.1 2. No energy calcs on site FBC(A) 107.3.1 --Must have on site for next inspection to avoid failures and fees | |||
| ROW- PRE-APRON (PRE-POUR) | 05/12/2026 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. WOOD CONTROL JOINTS ARE PROHIBITED IN THE RIGHT-OF-WAY. SAWCUT SHALL BE PROVIDED AT THE EDGE OF ROW AND EVERY 12' THEREAFTER, OR A MINIMUM OF 2 SAWCUTS WHICHEVER IS GREATER" 5/11/2026 - PREVIOUS INSPECTION NOTES RECIEVED CALL FROM JIM THE CM ASKING TO PLEASE CANCEL INSPECTION AS DRIVEWAY WAS NOT RAILED UP YET | |||
| ROW- PRE-APRON (PRE-POUR) | 05/11/2026 | CANCELLED BY APPLICANT | TPOLACEK |
| Note: RECIEVED CALL FROM JIM THE CM ASKING TO PLEASE CANCEL INSPECTION AS DRIVEWAY WAS NOT RAILED UP YET | |||
| ELECTRIC - EARLY POWER | 05/05/2026 | APPROVED - AS NOTED | JSTEWART |
| Note: Authorize release of email. | |||
| GRAVITY SEWER TEST | 04/21/2026 | APPROVED | KSANDOE |
| Note: 4/17/2026 - PREVIOUS INSPECTION NOTES re inspection, after sewer tie in is repaired. | |||
| SEWER TIE IN | 04/21/2026 | APPROVED | KSANDOE |
| Note: 4/17/2026 - PREVIOUS INSPECTION NOTES Cleanout and wye is required by the City of Palm coast to be WITHIN 3ft of the sewer connection to Pep tank, currently 5ft+. | |||
| GRAVITY SEWER TEST | 04/17/2026 | Disapproved - NO FEE | JSTEWART |
| Note: re inspection, after sewer tie in is repaired. | |||
| SEWER TIE IN | 04/17/2026 | Disapproved - NO FEE | JSTEWART |
| Note: Cleanout and wye is required by the City of Palm coast to be WITHIN 3ft of the sewer connection to Pep tank, currently 5ft+. | |||
| PEP TANK INSTALLATION REQUEST | 04/01/2026 | APPROVED | ISANDERSON |
| Note: 3/25/2026 12:37:33 PM- PREVIOUS INSPECTION NOTES Dumpster in the way | |||
| PEP TANK INSTALLATION REQUEST | 03/25/2026 | Disapproved - NO FEE | ISANDERSON |
| Note: Dumpster in the way | |||
| INSULATION | 03/23/2026 | APPROVED - AS NOTED | JSTEWART |
| Note: If SGD panels are not installed prior to hanging drywall, Please block opening with plastic for inclement weather. 3/19/2026 - PREVIOUS INSPECTION NOTES Cannot use standard gap foam for annular penetrations at dryer vent, ac cabinet, and thermostat wire. Still missing energy calcs and product approvals. Inspector Notes from Inspection 2420 3/12/26 1. No product approvals on site FBC(A) 107.3.1 2. No energy calcs on site FBC(A) 107.3.1 --Must have on site for next inspection to avoid failures and fees | |||
| INSULATION | 03/19/2026 | Disapproved - NO FEE | KSANDOE |
| Note: Cannot use standard gap foam for annular penetrations at dryer vent, ac cabinet, and thermostat wire. Still missing energy calcs and product approvals. Inspector Notes from Inspection 2420 3/12/26 1. No product approvals on site FBC(A) 107.3.1 2. No energy calcs on site FBC(A) 107.3.1 --Must have on site for next inspection to avoid failures and fees | |||
| ALL ROUGH | 03/12/2026 | APPROVED - AS NOTED | MCONTRYMAN |
| Note: 3/12/26 1. No product approvals on site FBC(A) 107.3.1 2. No energy calcs on site FBC(A) 107.3.1 --Must have on site for next inspection to avoid failures and fees | |||
| LATH/BRICK/ WATER BARRIER | 03/11/2026 | APPROVED | KSANDOE |
| WALL SHEATHING | 03/03/2026 | APPROVED | JSTEWART |
| WATER METER INSTALLATION REQUEST | 03/03/2026 | APPROVED | ISANDERSON |
| ROOF VALLEY & METAL | 02/24/2026 | APPROVED | KSANDOE |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/19/2026 | APPROVED | CVANSTRAHLEN |
| TIE BEAM / LINTEL | 02/12/2026 | APPROVED | JSTEWART |
| Note: 2/11/2026 - PREVIOUS INSPECTION NOTES Repairs have not been made 2/10/2026 - PREVIOUS INSPECTION NOTES Missing footing dowel for left side of left bathroom window. drop dowel is installed but not tied to a footing dowel. | |||
| TIE BEAM / LINTEL | 02/11/2026 | Disapproved -FEE REQUIRED | KSANDOE |
| Note: Repairs have not been made 2/10/2026 - PREVIOUS INSPECTION NOTES Missing footing dowel for left side of left bathroom window. drop dowel is installed but not tied to a footing dowel. | |||
| TIE BEAM / LINTEL | 02/10/2026 | Disapproved - NO FEE | JSTEWART |
| Note: Missing footing dowel for left side of left bathroom window. drop dowel is installed but not tied to a footing dowel. | |||
| MONOLITHIC SLAB | 02/02/2026 | Disapproved - NO FEE | JSTEWART |
| Note: FBC [A] 105.11 NOTICE OF TERMITE INSPECTION | |||
| MONOLITHIC SLAB | 02/02/2026 | APPROVED | JSTEWART |
| Note: Live virtual re inspection, correction completed. 2/2/2026 - PREVIOUS INSPECTION NOTES FBC [A] 105.11 NOTICE OF TERMITE INSPECTION | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 01/29/2026 | Disapproved - NO FEE | MKRASKI |
| Note: 1. No plumbing riser diagram onsite, please have a full set of plans on site for inspection with Building Dept. stamp of approval FBC 107.3.1 | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 01/29/2026 | APPROVED | MKRASKI |
| FORMBOARD SURVEY (OFFICE USE ONLY) | 01/27/2026 | APPROVED | RRICKS |
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 01/27/2026 | APPROVED | PKNAPIK |
| BLD - BUILDING FINAL | |||
| Note: 6/10/2026 - PREVIOUS INSPECTION NOTES 1. Tighten Multiple anchors at garage door bucks. per plan 2. Lower garage door saftey devices max 8" off floor. UL 325 3. Seal water heater Power penetration into CMU wall. R302.5 4. Post termite plaque. FBC 105.11 5. Seal wall penetration in AHU closet (liquid lines). FBC R302.11(4) 6. Spare bath exhaust fan missing cover. per plan/ manufacturer. Inspector Notes from Inspection 2490 If SGD panels are not installed prior to hanging drywall, Please block opening with plastic for inclement weather. 3/19/2026 - PREVIOUS INSPECTION NOTES Cannot use standard gap foam for annular penetrations at dryer vent, ac cabinet, and thermostat wire. Still missing energy calcs and product approvals. Inspector Notes from Inspection 2420 3/12/26 1. No product approvals on site FBC(A) 107.3.1 2. No energy calcs on site FBC(A) 107.3.1 --Must have on site for next inspection to avoid failures and fees | |||
| U-CROSS CONNECTION | |||
| ROW - FINAL APRON (AFTER POUR) | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | |||
| ROW - FINAL INSPECTION | |||
| U -UTILITY RESIDENTIAL FINAL |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 03/13/2026 | 03/18/2026 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 01/27/2026 | 01/27/2026 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 01/27/2026 | 01/27/2026 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 01/27/2026 | 01/27/2026 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 01/23/2026 | 01/26/2026 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 10/28/2025 | 10/29/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 10/28/2025 | 11/03/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 10/27/2025 | 10/27/2025 |
| Note: Marked INFORMATION By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM 1. SELECT 'PLANS' FROM DROPDOWN MENU, NOT TRUSS PLANS 2. RENAME TO ENERGY CALCS.PDF | |||
| BLD | HOLD | 10/22/2025 | 10/24/2025 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Truss packet or truss layout needs shop drawing approval stamp by engineer of record. | |||
| BLD | HOLD | 10/15/2025 | 10/21/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Complete truss plan packet cover sheet or first page to include the design professional of record (building design engineer or architect) approval stamp indicating acceptance and approval of truss design (Not wet seal) | |||
| CUSVC | COMPLETE | 10/15/2025 | 10/21/2025 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 10/15/2025 | 10/20/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 10/15/2025 | 10/15/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 10/15/2025 | 10/16/2025 |
| LOCATE | COMPLETE | 10/15/2025 | 10/17/2025 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | HOLD | 10/15/2025 | 10/20/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Indoor design temp on heatload must be a minimum of 75 degrees per R302.1 FBC Energy Conservation 2023 8Th edition | |||
| SW1 | COMPLETE | 10/15/2025 | 10/20/2025 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 10/15/2025 | 10/17/2025 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 10/15/2025 | 11/24/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| FC IMPACT FEE EMS | ¤62.00 | 11/10/2025 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 11/10/2025 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 11/10/2025 |
| FIRE RES IMPACT FEE 10-25 | ¤942.00 | 11/10/2025 |
| PEP TANK INSTALL | ¤756.74 | 11/10/2025 |
| PARKS IMPACT FEE 10-25 | ¤3,164.00 | 11/10/2025 |
| RSI DRIVEWAY AFTER POUR | ¤16.25 | 11/10/2025 |
| RSE DRIVE PRE POUR INSPECTION | ¤32.50 | 11/10/2025 |
| RSI FIELD SURVEY INSPECTION | ¤48.75 | 11/10/2025 |
| RSI FORMBOARD REVIEW | ¤16.25 | 11/10/2025 |
| RSI PLAN REVIEW NEW | ¤48.75 | 11/10/2025 |
| RSI FNL SURVEY/GRADING CERT | ¤48.75 | 11/10/2025 |
| RSI ROW FINAL INSPECTION | ¤16.25 | 11/10/2025 |
| SCHOOL BOARD IMPACT FEE RES | ¤5,450.00 | 11/10/2025 |
| WASTEWATER MAIN EXTENSION IMPA | ¤2,385.00 | 11/10/2025 |
| SURCHARGE FS 533.721 | ¤14.10 | 11/10/2025 |
| SURCHARGE - FS 468.631 | ¤21.15 | 11/10/2025 |
| SW ENG RES REVIEW 240 | ¤240.00 | 11/10/2025 |
| WATER METER W/ TAP | ¤2,326.93 | 11/10/2025 |
| TRANSP RES IMPACT FEE 10-25 | ¤7,061.21 | 11/10/2025 |
| SEWER CREDIT | (¤1,342.00) | 11/10/2025 |
| WASTEWATER PERM INSPECTION | ¤80.00 | 11/10/2025 |
| WASTEWATER PERM REVIEW | ¤25.00 | 11/10/2025 |
| SEWER CAPITAL FACILITY | ¤4,415.00 | 11/10/2025 |
| WATER CAPITAL FACILITY FEE | ¤3,790.49 | 11/10/2025 |
| WATER PERMIT REVIEW | ¤25.00 | 11/10/2025 |
| WATER MAIN EXTENSION IMPACT | ¤917.27 | 11/10/2025 |
| SITE PLAN 30 | ¤30.00 | 11/10/2025 |
| WATER- TURN ON | ¤50.00 | 11/10/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 11/10/2025 |
| INSPECTION - RESIDENTIAL | ¤1,075.25 | 11/10/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤304.98 | 11/10/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | |
| Fees | Total Due: ¤40.00 | Total Paid: ¤32,537.62 |