I want to search for...

Permit #2025100717

Permit Details

Status: INSPECT

Parcel Id: 04-11-30-5571-00000-3420
CONDITIONED SPACE: 1638 sqft
GARAGE: 461 sqft
OPENED PORCH (WITH ROOF) : 96 sqft
OPENED PORCH (WITH ROOF) : 112 sqft
Total Square Footage: 2307 sqft
Subdivision: 2366 - SOMERSET SUBDIVISION PH 2
Job Phone: 904-596-6645
Location Address: 53 SOMERSET AVE
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 12/23/2025
NOC: RECORDED
Applicant name: MICHAEL T HOLDER
Owner: KB HOME JACKSONVILLE LLC

Address

10475 FORTUNE PARKWAY

JACKSONVILLE, FL 32256

Address

SUITE 100

JACKSONVILLE, FL 32256

Lot: 342
Contracted Stated Job Value: ¤140,000.00
Job Description: NEW SINGLE FAMILY DWELLING
Type: CN

Contractor

KB HOME JACKSONVILLE, LLC
Status Location Address Mailing Address State License Number Phone
ACTIVE

10475 FORTUNE PKWY

JACKSONVILLE, FL 32256

SUITE 100

JACKSONVILLE, FL 32256

CGC1509034 (Exp: 08/31/2026) 904-596-6645

Sub Contractors

BOBBY WAYNE CAMPBELL
Status Location Address State License Number Phone
ACTIVE

117 GUTHRIE ROAD

GREEN COVE SPRINGS, FL 32043

CCC1326752 (Exp: 08/31/2026) 904-200-1600
COREY MICHAEL TENNANT
Status Location Address State License Number Phone
ACTIVE

3370 AGRICULTURAL CNETER DR

ST AUGUSTINE, FL 32092

CAC1819063 (Exp: 08/31/2026) 904-829-8898
JAMES E LINTON
Status Location Address State License Number Phone
ACTIVE

200 COLLEGE DR

ORANGE PARK, FL 32065

EC0001152 (Exp: 08/31/2026) 904-272-0272
BENJAMIN MICHAEL RAY
Status Location Address Mailing Address State License Number Phone Fax
ACTIVE

6310 MABLETON PKWY

JACKSONVILLE, FL 32216

SUITE 1000

MABLETON, GA 30126

CFC1428415 (Exp: 08/31/2026) 904-861-5421 904-861-5426
LARRY WILLIAMS
Status Location Address State License Number Phone
ACTIVE

1750 EMERSON ST

JACKSONVILLE, FL 32207

LI45034 (Exp: 08/31/2026) 904-721-5431

Inspection History

Type Request Date Result Inspector
ROW- PROJECT STATUS 05/14/2026 APPROVED - AS NOTED RRICKS
Note: 5/14/2026 - RRicks Gabriel and I conducted a site visit and there is severe erosion on 49,51, and 53 where the ground was disturbed and new sod was installed. Please make all necessary corrections as soon as possible.
ROW- FINAL SURVEY/GRADING CERTIFICATION 05/14/2026 Disapproved - NO FEE RRICKS
Note: 5/14/2026 - RRicks Checklist Item 23: As discussed with Fidel and Scott, the approved master plan and the approved grading plan have this lot as an A-type NOT a B-type. Gabriel and I conducted a site visit and there is severe erosion on 49,51, and 53 where the ground was disturbed and new sod was installed. Please make all necessary corrections as soon as possible.
BLD - BUILDING FINAL 03/19/2026 FINAL APPROVED JSTEWART
Note: 3/16/2026 - PREVIOUS INSPECTION NOTES 1. Loose locking caps on outside unit. FBCR M1411.8 2. Garage door inoperable. 3. No hot water. 4. Missing weather striping in front door. 5. Missing insulation certificate. FBC EC R303.1.1.2
U-CROSS CONNECTION 03/16/2026 APPROVED - AS NOTED BVEIGA
Note: No CC. IRR with reuse water.
BLD - BUILDING FINAL 03/16/2026 Disapproved - NO FEE PKNAPIK
Note: 1. Loose locking caps on outside unit. FBCR M1411.8 2. Garage door inoperable. 3. No hot water. 4. Missing weather striping in front door. 5. Missing insulation certificate. FBC EC R303.1.1.2
ELECTRIC - EARLY POWER 02/27/2026 APPROVED KSANDOE
Note: Inspector Notes from Inspection 2200 Authorize release of email.
ROW- PRE-APRON (PRE-POUR) 02/10/2026 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. . TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, IN THE UPCOMING MONTHS THE DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS WILL BE REQUIRED TO BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. YOU WILL RECEIVE A NEWS BLAST WHEN THIS BECOMES NECESSARY
INSULATION 02/04/2026 APPROVED JSTEWART
Note: 2/3/2026 - PREVIOUS INSPECTION NOTES Previous Not not rectified......2. Hood exhaust duct is installed in reverse, please install where the male end at the laps are in the direction of flow. joints are required to lap min 1" and connected with 3 screws, lap in the direction of flow. (cannot butt the seams). Inspector Notes from Inspection 2420 *** NOTES ADDED BY JSTEWART 1/30/2026 10:37:23 AM *** disreguard note number 3. Pulled up wrong address. 1. Please re seal dryer duct roof penetration. FBCR M1601.4.1 / M1501.1 2. Hood exhaust duct is installed in reverse, please install where the male end at the laps are in the direction of flow. M1601.4.2 3. Please submit a revision of energy calcs for HVAC dust layout, (Added Trunk duct, and distribution Box). FBC (A) 107.4 Corrections prior to Insulation.
INSULATION 02/03/2026 Disapproved -FEE REQUIRED JSTEWART
Note: Previous Not not rectified......2. Hood exhaust duct is installed in reverse, please install where the male end at the laps are in the direction of flow. joints are required to lap min 1" and connected with 3 screws, lap in the direction of flow. (cannot butt the seams). Inspector Notes from Inspection 2420 *** NOTES ADDED BY JSTEWART 1/30/2026 10:37:23 AM *** disreguard note number 3. Pulled up wrong address. 1. Please re seal dryer duct roof penetration. FBCR M1601.4.1 / M1501.1 2. Hood exhaust duct is installed in reverse, please install where the male end at the laps are in the direction of flow. M1601.4.2 3. Please submit a revision of energy calcs for HVAC dust layout, (Added Trunk duct, and distribution Box). FBC (A) 107.4 Corrections prior to Insulation.
LATH/BRICK/ WATER BARRIER 02/03/2026 APPROVED JSTEWART
Note: Inspector Notes from Inspection 2420 *** NOTES ADDED BY JSTEWART 1/30/2026 10:37:23 AM *** disreguard note number 3. Pulled up wrong address. 1. Please re seal dryer duct roof penetration. FBCR M1601.4.1 / M1501.1 2. Hood exhaust duct is installed in reverse, please install where the male end at the laps are in the direction of flow. M1601.4.2 3. Please submit a revision of energy calcs for HVAC dust layout, (Added Trunk duct, and distribution Box). FBC (A) 107.4 Corrections prior to Insulation.
ALL ROUGH 01/30/2026 APPROVED - AS NOTED JSTEWART
Note: *** NOTES ADDED BY JSTEWART 1/30/2026 10:37:23 AM *** disreguard note number 3. Pulled up wrong address. 1. Please re seal dryer duct roof penetration. FBCR M1601.4.1 / M1501.1 2. Hood exhaust duct is installed in reverse, please install where the male end at the laps are in the direction of flow. M1601.4.2 3. Please submit a revision of energy calcs for HVAC dust layout, (Added Trunk duct, and distribution Box). FBC (A) 107.4 Corrections prior to Insulation.
ELECTRIC-TUG 01/30/2026 APPROVED - AS NOTED JSTEWART
Note: Authorize release of email.
ROOF VALLEY & METAL 01/26/2026 APPROVED JSTEWART
Note: Inspector Notes from Inspection 2450 Prior dis approval was entered in error wrong address, sheathing is approved. 1/21/2026 - PREVIOUS INSPECTION NOTES Missing nails thruought. Nails need to be embedded (sticking out to far) Excessive shiners need to be removed and replaced. Inspector Notes from Inspection 2250 Return Inspection 2:05pm. Corrections completed, footer depths range from 26" to 28" from top of form boards. 1/8/2026 - PREVIOUS INSPECTION NOTES Footing needs to be deeper in undisturbed ground Min 25" from top of form board. evaluated from Grade and drainage plan submitted and approved of a FFE 39.10, and the Lowest point of finish grade is at 38.0, which would have 13.2" of foundation above grade, Footing requires a min of 12" below final Grade. Per plan / R403.1.4 Minimum depth. Previous was approved on accident wrong address. Inspection still required.
WALL SHEATHING 01/21/2026 Disapproved - NO FEE JSTEWART
Note: *** NOTES ADDED BY JSTEWART 1/21/2026 2:59:06 PM *** disreguard previous notes entered wrong address. added inspection back and approved Missing nails thruought. Nails need to be embedded (sticking out to far) Excessive shiners need to be removed and replaced. Inspector Notes from Inspection 2250 Return Inspection 2:05pm. Corrections completed, footer depths range from 26" to 28" from top of form boards. 1/8/2026 - PREVIOUS INSPECTION NOTES Footing needs to be deeper in undisturbed ground Min 25" from top of form board. evaluated from Grade and drainage plan submitted and approved of a FFE 39.10, and the Lowest point of finish grade is at 38.0, which would have 13.2" of foundation above grade, Footing requires a min of 12" below final Grade. Per plan / R403.1.4 Minimum depth.
WALL SHEATHING 01/21/2026 APPROVED - AS NOTED JSTEWART
Note: Prior dis approval was entered in error wrong address, sheathing is approved. 1/21/2026 - PREVIOUS INSPECTION NOTES Missing nails thruought. Nails need to be embedded (sticking out to far) Excessive shiners need to be removed and replaced. Inspector Notes from Inspection 2250 Return Inspection 2:05pm. Corrections completed, footer depths range from 26" to 28" from top of form boards. 1/8/2026 - PREVIOUS INSPECTION NOTES Footing needs to be deeper in undisturbed ground Min 25" from top of form board. evaluated from Grade and drainage plan submitted and approved of a FFE 39.10, and the Lowest point of finish grade is at 38.0, which would have 13.2" of foundation above grade, Footing requires a min of 12" below final Grade. Per plan / R403.1.4 Minimum depth.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 01/21/2026 APPROVED - AS NOTED JSTEWART
Note: *** NOTES ADDED BY JSTEWART 1/21/2026 2:56:41 PM *** Disreguard previous notes entered on wrong address. Approved Missing Nails at dry bottoms front and back porch posts. Moving forward all clips and tie downs need to be nailed to the structural member if using short stub nails, if going thru sheathing will need to use 2" nails for proper embeddment. I spoke with framing super. Inspector Notes from Inspection 2250 Return Inspection 2:05pm. Corrections completed, footer depths range from 26" to 28" from top of form boards. 1/8/2026 - PREVIOUS INSPECTION NOTES Footing needs to be deeper in undisturbed ground Min 25" from top of form board. evaluated from Grade and drainage plan submitted and approved of a FFE 39.10, and the Lowest point of finish grade is at 38.0, which would have 13.2" of foundation above grade, Footing requires a min of 12" below final Grade. Per plan / R403.1.4 Minimum depth.
ROOF VALLEY & METAL 01/21/2026 APPROVED - AS NOTED JSTEWART
Note: Please seal L flashing at roof to wall prior to lath/brick/water barrier Inspector Notes from Inspection 2250 Return Inspection 2:05pm. Corrections completed, footer depths range from 26" to 28" from top of form boards. 1/8/2026 - PREVIOUS INSPECTION NOTES Footing needs to be deeper in undisturbed ground Min 25" from top of form board. evaluated from Grade and drainage plan submitted and approved of a FFE 39.10, and the Lowest point of finish grade is at 38.0, which would have 13.2" of foundation above grade, Footing requires a min of 12" below final Grade. Per plan / R403.1.4 Minimum depth.
GRAVITY SEWER TEST 01/20/2026 APPROVED JSTEWART
Note: *** NOTES ADDED BY JSTEWART 1/20/2026 11:37:22 AM *** Live virtual Inspector Notes from Inspection 2060 At time of inspection water supply has not been hooked up to utility, Notes from Building offical will be checked at mono inspection-"At the front of the home, the grade adjacent to the foundation on the right side shows a 1.1' drop from the finished floor. Please verify that this grade can be achieved while still maintaining the required 12" of footer burial"
SEWER TIE IN 01/20/2026 APPROVED JSTEWART
Note: *** NOTES ADDED BY JSTEWART 1/20/2026 11:37:42 AM *** Live virtual Inspector Notes from Inspection 2060 At time of inspection water supply has not been hooked up to utility, Notes from Building offical will be checked at mono inspection-"At the front of the home, the grade adjacent to the foundation on the right side shows a 1.1' drop from the finished floor. Please verify that this grade can be achieved while still maintaining the required 12" of footer burial"
MONOLITHIC SLAB 01/08/2026 Disapproved - NO FEE JSTEWART
Note: Footing needs to be deeper in undisturbed ground Min 25" from top of form board. evaluated from Grade and drainage plan submitted and approved of a FFE 39.10, and the Lowest point of finish grade is at 38.0, which would have 13.2" of foundation above grade, Footing requires a min of 12" below final Grade. Per plan / R403.1.4 Minimum depth.
MONOLITHIC SLAB 01/08/2026 APPROVED - AS NOTED JSTEWART
Note: Return Inspection 2:05pm. Corrections completed, footer depths range from 26" to 28" from top of form boards. 1/8/2026 - PREVIOUS INSPECTION NOTES Footing needs to be deeper in undisturbed ground Min 25" from top of form board. evaluated from Grade and drainage plan submitted and approved of a FFE 39.10, and the Lowest point of finish grade is at 38.0, which would have 13.2" of foundation above grade, Footing requires a min of 12" below final Grade. Per plan / R403.1.4 Minimum depth.
PLUMBING 1ST ROUGH UNDERGROUND 12/31/2025 APPROVED - AS NOTED MKRASKI
Note: At time of inspection water supply has not been hooked up to utility, Notes from Building offical will be checked at mono inspection-"At the front of the home, the grade adjacent to the foundation on the right side shows a 1.1' drop from the finished floor. Please verify that this grade can be achieved while still maintaining the required 12" of footer burial"
WATER METER INSTALLATION REQUEST 12/31/2025 APPROVED CBOWERMASTER
FORMBOARD SURVEY (OFFICE USE ONLY) 12/29/2025 APPROVED RRICKS
ROW - FINAL APRON (AFTER POUR)
ROW- FINAL SURVEY/GRADING CERTIFICATION
Note: 5/14/2026 9:02:55 AM- PREVIOUS INSPECTION NOTES 5/14/2026 - RRicks Checklist Item 23: As discussed with Fidel and Scott, the approved master plan and the approved grading plan have this lot as an A-type NOT a B-type. Gabriel and I conducted a site visit and there is severe erosion on 49,51, and 53 where the ground was disturbed and new sod was installed. Please make all necessary corrections as soon as possible.
ROW - FINAL INSPECTION
U -UTILITY RESIDENTIAL FINAL

Review History

Department Status Date In Date Out
SW1 COMPLETE 12/26/2025 12/26/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 12/26/2025 12/26/2025
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
SW1 COMPLETE 12/17/2025 12/22/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Approved as noted: There is a proposed 1.1' grade drop at the front right side of this home from the finished floor. Please ensure this drop can be made and still meet the FBC requiring 12" of footer burial. Note 1: There is an approved modification 6508 increasing the FFEs of both lots. Approved grading plan does not reflect the modified FFEs.
SW1 HOLD 11/07/2025 11/12/2025
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM After further conversations with Dennis Leap the City's Engineer. Please review all A-type lots with this same issue for this subdivision and submit modification for each. If there are any questions or concerns. Please call Dennis Leap 386-986-2482.
URB COMPLETE 10/21/2025 10/28/2025
Note: Released By: JOHN BEAUDET - (386)986-2456 - JBEAUDET@PALMCOASTGOV.COM
BLD COMPLETE 10/20/2025 10/24/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
CUSVC COMPLETE 10/20/2025 10/27/2025
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 10/20/2025 10/24/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 10/20/2025 10/21/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS COMPLETE 10/20/2025 10/21/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
LOCATE COMPLETE 10/20/2025 10/23/2025
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 10/20/2025 10/21/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 HOLD 10/20/2025 10/23/2025
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Grading Plan Comments: - Please provide an engineer's letter explaining why the deviation from the approved master plan is needed. - There shall be a minimum of 0.3' from the back of the lot to the rear yard drainage swale so the water flow to the front of this lot as designed.
ZON COMPLETE 10/20/2025 10/22/2025
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
FC IMPACT FEE EMS ¤62.00 12/23/2025
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 12/23/2025
FC IMPACT FEE LIBRARY ¤268.00 12/23/2025
FIRE RES IMPACT FEE 10-25 ¤942.00 12/23/2025
WATER METER W/OUT TAP ¤965.03 12/23/2025
PARKS IMPACT FEE 10-25 ¤3,164.00 12/23/2025
RECLAIM WATER PERMIT INSPECTIO ¤40.00 12/23/2025
RSI DRIVEWAY AFTER POUR ¤16.25 12/23/2025
RSE DRIVE PRE POUR INSPECTION ¤32.50 12/23/2025
RSI FIELD SURVEY INSPECTION ¤48.75 12/23/2025
RSI FORMBOARD REVIEW ¤16.25 12/23/2025
RSI PLAN REVIEW NEW ¤48.75 12/23/2025
RSI FNL SURVEY/GRADING CERT ¤48.75 12/23/2025
RSI ROW FINAL INSPECTION ¤16.25 12/23/2025
SCHOOL BOARD IMPACT FEE RES ¤5,450.00 12/23/2025
SURCHARGE FS 533.721 ¤11.84 12/23/2025
SURCHARGE - FS 468.631 ¤17.77 12/23/2025
TRANSP RES IMPACT FEE 10-25 ¤6,175.26 12/23/2025
WASTEWATER PERM INSPECTION ¤80.00 12/23/2025
WASTEWATER PERM REVIEW ¤25.00 12/23/2025
SEWER CAPITAL FACILITY ¤3,628.86 12/23/2025
WATER CAPITAL FACILITY FEE ¤3,091.14 12/23/2025
WATER PERMIT REVIEW ¤25.00 12/23/2025
SITE PLAN 30 ¤30.00 12/23/2025
WATER-METER ¤874.47 12/23/2025
WATER- TURN ON ¤50.00 12/23/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 12/23/2025
INSPECTION - RESIDENTIAL ¤899.25 12/23/2025
PLAN REVIEW - RESIDENTIAL ¤255.06 12/23/2025
REINSPECTION RESIDENTIAL ¤40.00
Fees Total Due: ¤40.00 Total Paid: ¤26,530.18