I want to search for...

Permit #2025101043

Permit Details

Status: INSPECT

Parcel Id: 07-11-31-7037-00030-0100
OPENED PORCH (WITH ROOF) : 249 sqft
GARAGE: 759 sqft
CONDITIONED SPACE: 1873 sqft
Total Square Footage: 2881 sqft
Block: 00030
Subdivision: -
Job Phone: 352-433-8382
Location Address: 11 LUTHER DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 11/26/2025
NOC: RECORDED
Applicant name: ALFREDO E SCHEER
Owner: ESTELA SPECS 6 LLC

Address

425 PERUGIA AVENUE

CORAL GABLES, FL 33146

Lot: 0100
Contracted Stated Job Value: ¤165,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

ESTELA LIVING LLC
Status Location Address State License Number Phone
ACTIVE

237 S. DIXIE HWY, 4TH FLOOR

CORAL GABLES, FL 33133

CGC1534535 (Exp: 08/31/2026) 352-433-8382

Sub Contractors

JUAN CARLOS GONZALEZ
Status Location Address State License Number
ACTIVE

1328 COUNTY ROAD 308

CRESCENT CITY, FL 32112

RF11067806 (Exp: 08/31/2027)
DUSTIN L ESTEP
Status Location Address State License Number Phone Fax
ACTIVE

2041 N HIAWASSEE RD

APOPKA, FL 32703

CCC1330971 (Exp: 08/31/2026) 407-702-0206 352-988-6629
JOSEPH HORATIO STRADA JR
Status Location Address State License Number Phone
ACTIVE

3400 ST JOHNS PARKWAY

SANFORD, FL 32771

EC13003715 (Exp: 08/31/2026) 877-906-1113
JOSEPH H STRADA JR
Status Location Address State License Number Phone
ACTIVE

3400 ST JOHNS PKWY

SANFORD, FL 32771

CAC043953 (Exp: 08/31/2026) 877-906-1113

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 06/03/2026 CANCELLED BY APPLICANT WEB
ELECTRIC - EARLY POWER 05/05/2026 APPROVED - AS NOTED JSTEWART
Note: Authorize release of email
ROW- PRE-APRON (PRE-POUR) 04/30/2026 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. WOOD CONTROL JOINTS ARE PROHIBITED IN THE RIGHT-OF-WAY. SAWCUT SHALL BE PROVIDED AT THE EDGE OF ROW AND EVERY 12' THEREAFTER, OR A MINIMUM OF 2 SAWCUTS WHICHEVER IS GREATER" 4/28/2026 - PREVIOUS INSPECTION NOTES ** 04/28/26 SITE IS NOT READY FOR TODAYS PRE-POUR INSPECTION (NOT FORMED)
ROW- PRE-APRON (PRE-POUR) 04/28/2026 Disapproved -FEE REQUIRED EMADISON
Note: ** 04/28/26 SITE IS NOT READY FOR TODAYS PRE-POUR INSPECTION (NOT FORMED)
SEWER TIE IN 04/21/2026 APPROVED KSANDOE
Note: 4/17/2026 - PREVIOUS INSPECTION NOTES Cleanout and wye is required by the City of Palm coast to be WITHIN 3ft of the sewer connection to Pep tank, currently 6ft+.
GRAVITY SEWER TEST 04/21/2026 APPROVED KSANDOE
Note: 4/17/2026 - PREVIOUS INSPECTION NOTES Re inspect once sewer tie in is repaired.
GRAVITY SEWER TEST 04/17/2026 Disapproved - NO FEE JSTEWART
Note: Re inspect once sewer tie in is repaired.
SEWER TIE IN 04/17/2026 Disapproved - NO FEE JSTEWART
Note: Cleanout and wye is required by the City of Palm coast to be WITHIN 3ft of the sewer connection to Pep tank, currently 6ft+.
GRAVITY SEWER TEST 03/30/2026 CANCELLED BY APPLICANT WEB
SEWER TIE IN 03/30/2026 CANCELLED BY APPLICANT WEB
PEP TANK INSTALLATION REQUEST 03/27/2026 APPROVED ISANDERSON
INSULATION 03/23/2026 APPROVED JSTEWART
Note: 3/19/2026 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2320 Inspector Notes from Inspection 2420 *** NOTES ADDED BY MCONTRYMAN 3/12/2026 9:34:50 AM *** 4. No 5' head test FBCR P2503.7 3/12/26 Must have compleed and on site by next inspection! 1. Nail plate needed in back right bedroom (labeled NP on framing) NEC 300.4 2. No Energy calcs on site FBC(A) 107.3.1 3. No product approvals on site FBC(A) 107.3.1
INSULATION 03/19/2026 CANCELLED BY APPLICANT KSANDOE
Note: Inspector Notes from Inspection 2320 Inspector Notes from Inspection 2420 *** NOTES ADDED BY MCONTRYMAN 3/12/2026 9:34:50 AM *** 4. No 5' head test FBCR P2503.7 3/12/26 Must have compleed and on site by next inspection! 1. Nail plate needed in back right bedroom (labeled NP on framing) NEC 300.4 2. No Energy calcs on site FBC(A) 107.3.1 3. No product approvals on site FBC(A) 107.3.1
LATH/BRICK/ WATER BARRIER 03/16/2026 APPROVED - AS NOTED KSANDOE
Note: Inspector Notes from Inspection 2420 *** NOTES ADDED BY MCONTRYMAN 3/12/2026 9:34:50 AM *** 4. No 5' head test FBCR P2503.7 3/12/26 Must have compleed and on site by next inspection! 1. Nail plate needed in back right bedroom (labeled NP on framing) NEC 300.4 2. No Energy calcs on site FBC(A) 107.3.1 3. No product approvals on site FBC(A) 107.3.1
ALL ROUGH 03/12/2026 APPROVED - AS NOTED MCONTRYMAN
Note: *** NOTES ADDED BY MCONTRYMAN 3/12/2026 9:34:50 AM *** 4. No 5' head test FBCR P2503.7 3/12/26 Must have compleed and on site by next inspection! 1. Nail plate needed in back right bedroom (labeled NP on framing) NEC 300.4 2. No Energy calcs on site FBC(A) 107.3.1 3. No product approvals on site FBC(A) 107.3.1
ROOF VALLEY & METAL 03/09/2026 APPROVED JSTEWART
WALL SHEATHING 03/03/2026 APPROVED JSTEWART
ROOF SHEATHING / BRACES/TIES/DOWN CELL 02/24/2026 APPROVED JSTEWART
TIE BEAM / LINTEL 02/17/2026 APPROVED MKRASKI
MONOLITHIC SLAB 02/06/2026 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 2/6/2026 2:35:39 PM ***
PLUMBING 1ST ROUGH UNDERGROUND 02/04/2026 APPROVED MCONTRYMAN
Note: 2/2/2026 - PREVIOUS INSPECTION NOTES Water in the lines is frozen, the test is invalid because the ice may temporarily plug leaks, preventing the "visual inspection" and "leak-free" proof required by code. FBPC 312.5 Water supply system test. Inspection will be needed once Lines are thawed and preassure test is at working preassure.
PLUMBING 1ST ROUGH UNDERGROUND 02/02/2026 Disapproved - NO FEE JSTEWART
Note: *** NOTES ADDED BY JSTEWART 2/2/2026 9:58:24 AM *** In addition Please sleeve/insulate pex where they cross other plumbing for protection of plumbing. Per manufacturer spec. P2906.10.2 Mechanical joints. Please seperate Hot and cold supply lines in trench. Per manufactuer spec Min of 6" seperation. 308.9 Parallel water distribution systems. Water in the lines is frozen, the test is invalid because the ice may temporarily plug leaks, preventing the "visual inspection" and "leak-free" proof required by code. FBPC 312.5 Water supply system test. Inspection will be needed once Lines are thawed and preassure test is at working preassure.
FORMBOARD SURVEY (OFFICE USE ONLY) 01/29/2026 APPROVED PFLANAGAN
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 01/27/2026 APPROVED PKNAPIK
WATER METER INSTALLATION REQUEST 12/29/2025 APPROVED CBOWERMASTER
U-CROSS CONNECTION
BLD - BUILDING FINAL
ROW - FINAL APRON (AFTER POUR)
ROW- FINAL SURVEY/GRADING CERTIFICATION
ROW - FINAL INSPECTION
U -UTILITY RESIDENTIAL FINAL

Review History

Department Status Date In Date Out
BLD COMPLETE 03/13/2026 03/18/2026
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
SW1 COMPLETE 01/29/2026 01/29/2026
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 01/29/2026 01/29/2026
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD COMPLETE 01/27/2026 01/27/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD COMPLETE 01/23/2026 01/26/2026
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 11/19/2025 11/20/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ZON COMPLETE 11/19/2025 11/19/2025
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
SW1 COMPLETE 11/19/2025 11/24/2025
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
BLD COMPLETE 11/19/2025 11/25/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
SWALE COMPLETE 10/29/2025 11/04/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
BLD HOLD 10/28/2025 11/03/2025
Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM Truss plan packet cover sheet or first page needs include the design professional of record (building design engineer or architect) approval stamp indicating acceptance and approval of truss design (Not wet seal)
CUSVC COMPLETE 10/28/2025 11/05/2025
Note: Released By: CYNTHIA SCHWEERS - - CSCHWEERS@PALMCOASSTGOV.COM
ELEC COMPLETE 10/28/2025 11/03/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 10/28/2025 10/29/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS CANCEL 10/28/2025 10/29/2025
LOCATE COMPLETE 10/28/2025 10/31/2025
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH HOLD 10/28/2025 10/29/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Indoor design temp on heatload must be a minimum of 75 degrees per R302.1 FBC Energy Conservation 2023 8Th edition 2. Direction house faces on Energy Calcs does not match the site plan. Revise to match per R405.4.2.1 FBC Energy Conservation 2023 8Th Edition 3. Energy Calcs and State Card need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2023 8Th edition
SW1 HOLD 10/28/2025 10/31/2025
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Grading comments: - Please move water to the front of home on the right side of home, based on the information provided slope is too aggressive going to the ditch and will cause wash outs. Please ensure slope going to ditch is a 4:1.
ZON HOLD 10/28/2025 10/29/2025
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM add banding to the Right side window that faces ROW

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
WATER- TURN ON ¤50.00 11/26/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 11/26/2025
INSPECTION - RESIDENTIAL ¤1,075.25 11/26/2025
PLAN REVIEW - RESIDENTIAL ¤304.98 11/26/2025
FC IMPACT FEE EMS ¤62.00 11/26/2025
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 11/26/2025
FC IMPACT FEE LIBRARY ¤268.00 11/26/2025
FIRE RES IMPACT FEE 10-25 ¤942.00 11/26/2025
PEP TANK INSTALL ¤756.74 11/26/2025
PARKS IMPACT FEE 10-25 ¤3,164.00 11/26/2025
RSI DRIVEWAY AFTER POUR ¤16.25 11/26/2025
RSE DRIVE PRE POUR INSPECTION ¤32.50 11/26/2025
RSI FIELD SURVEY INSPECTION ¤48.75 11/26/2025
RSI FORMBOARD REVIEW ¤16.25 11/26/2025
RSI PLAN REVIEW NEW ¤48.75 11/26/2025
RSI FNL SURVEY/GRADING CERT ¤48.75 11/26/2025
RSI ROW FINAL INSPECTION ¤16.25 11/26/2025
SCHOOL BOARD IMPACT FEE RES ¤5,450.00 11/26/2025
WASTEWATER MAIN EXTENSION IMPA ¤2,385.00 11/26/2025
SURCHARGE FS 533.721 ¤14.10 11/26/2025
SURCHARGE - FS 468.631 ¤21.15 11/26/2025
SW ENG RES REVIEW 240 ¤240.00 11/26/2025
WATER METER W/ TAP ¤2,326.93 11/26/2025
TRANSP RES IMPACT FEE 10-25 ¤7,061.21 11/26/2025
SEWER CREDIT (¤850.00) 11/26/2025
WASTEWATER PERM INSPECTION ¤80.00 11/26/2025
WASTEWATER PERM REVIEW ¤25.00 11/26/2025
SEWER CAPITAL FACILITY ¤4,415.00 11/26/2025
WATER CAPITAL FACILITY FEE ¤3,790.49 11/26/2025
WATER PERMIT REVIEW ¤25.00 11/26/2025
WATER MAIN EXTENSION IMPACT ¤917.27 11/26/2025
SITE PLAN 30 ¤30.00 11/26/2025
RSI REINSPECTION 1 ¤35.00
Fees Total Due: ¤35.00 Total Paid: ¤33,029.62