Permit #2025101075
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7064-00040-0190 |
| Total Square Footage: 1000 sqft |
| Block: 00040 |
| Subdivision: 7064 - |
| Job Phone: 904-229-8131 |
| Location Address: 37 LLOYD TRL |
| Type: ME - MECHANICAL |
| Issue Date: 10/29/2025 |
| NOC: Unknown |
| Applicant name: BRETT CHRISTIAN GIBSON |
| Owner: CALDERON JOSE R |
|
Address 37 LLOYD TRAIL PALM COAST, FL 32164 |
| Lot: 0190 |
| Contracted Stated Job Value: ¤5,000.00 |
| Job Description: hvac change out same for same |
| Type: CN |
Contractor
GIBSON'S HEATING AND AIR CONDITIONING
| Status | Location Address | State License Number | Phone |
| ACTIVE |
250 SEGOVIA RD ST AUGUSTINE, FL 32086 |
CAC1818423 (Exp: 08/31/2026) | 904-229-8131 |
Inspection History
| Type | Request Date | Result | Inspector |
| HVAC FINAL | 12/11/2025 | FINAL APPROVED | BTAYLOR |
| Note: 11/10/2025 - PREVIOUS INSPECTION NOTES 11/10/25: A Virtual inspection will be available IF requested at the time of scheduling the re-inspection. If requesting a Virtual Re-inspection, please schedule the re-inspection for the same day that the deficiencies will be corrected and a FaceTime or Google Meet live virtual inspection can be completed. (Pictures are not approved). 1). Exterior lineset sleeve needs to be sealed at the bottom. FBC-M1203.2.1 2). Breaker for outdoor unit is too large. (Min.-22.3 amp / Max.-35 amp -- 40 amp installed). 3). Heating core label needs to correctly identify core number and breaker size. Breaker size identified does not match required breaker for heating core identified. 11/5/2025 - PREVIOUS INSPECTION NOTES 11/5/25: Cancelled by Applicant via voicemail at @ 13:49. | |||
| HVAC FINAL | 11/10/2025 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 11/10/2025 1:22:14 PM *** 11/10/25: A Virtual inspection will be available IF requested at the time of scheduling the re-inspection. If requesting a Virtual Re-inspection, please schedule the re-inspection for the same day that the deficiencies will be corrected and a FaceTime or Google Meet live virtual inspection can be completed. (Pictures are not approved). 1). Exterior lineset sleeve needs to be sealed at the bottom. FBC-M1203.2.1 2). Breaker for outdoor unit is too large. (Min.-22.3 amp / Max.-35 amp -- 40 amp installed). 3). Heating core label needs to correctly identify core number and breaker size. Breaker size identified does not match required breaker for heating core identified. 11/5/2025 - PREVIOUS INSPECTION NOTES 11/5/25: Cancelled by Applicant via voicemail at @ 13:49. | |||
| HVAC FINAL | 11/05/2025 | CANCELLED BY APPLICANT | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 11/5/2025 2:09:42 PM *** 11/5/25: Cancelled by Applicant via voicemail at @ 13:49. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/10/2025 |
| SURCHARGE FS 533.721 | ¤2.00 | 10/29/2025 |
| SURCHARGE - FS 468.631 | ¤2.00 | 10/29/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 10/29/2025 |
| INSPECTION - MECHANICAL | ¤60.00 | 10/29/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤134.00 |