I want to search for...

Permit #2025110014

Permit Details

Status: COED

Parcel Id: 07-11-31-7012-00110-0420
Block: 00110
Subdivision: 7012 -
Job Phone: 386-437-2671
Location Address: 56 BALTIMORE LN
Type: SLRE - SOLAR ELECTRIC - PHOTOVOLTAIC
Issue Date: 11/06/2025
NOC: Unknown
Applicant name: WILLIAM JOHN GARITY
Owner: FREEMAN ROBERT H

Address

56 BALTIMORE LANE

PALM COAST, FL 32137

Lot: 0420
Contracted Stated Job Value: ¤4,999.00
Job Description: SOLAR PHOTOVOLTAIC - ROOF MOUNT
Type: CN

Contractor

ENERGY OUTLET INC DBA TEO SOLAR
Status Location Address State License Number Phone
ACTIVE

494 COUNTY ROAD 65

BUNNELL, FL 32110

CVC56703 (Exp: 08/31/2026) 386-437-2671

Inspection History

Type Request Date Result Inspector
SOLAR ELECTRIC FINAL 12/30/2025 FINAL APPROVED CVANSTRAHLEN
Note: 12/26/2025 - PREVIOUS INSPECTION NOTES 12/26/25 1. All wall and ceiling penitrations that were made must be sealed/caulk for garage fire seperation FBC R302.6 12/17/2025 - PREVIOUS INSPECTION NOTES 12/17/25 1. All wall and ceiling penitrations that were made must be sealed for garage fire seperation FBC R302.6 2. CT wiring must be protected and secured 3. Working space not met for subpanel, 3' min clearence required NEC 110.26 12/9/25 Please submit a revision of what is install, does not match plans......eliminated ac disconnect, wire size, Plans call for 100 amp breaker 80 amp installed. etc.
SOLAR ELECTRIC FINAL 12/26/2025 Disapproved - NO FEE RMARTIN
Note: 12/26/25 1. All wall and ceiling penitrations that were made must be sealed/caulk for garage fire seperation FBC R302.6 12/17/2025 - PREVIOUS INSPECTION NOTES 12/17/25 1. All wall and ceiling penitrations that were made must be sealed for garage fire seperation FBC R302.6 2. CT wiring must be protected and secured 3. Working space not met for subpanel, 3' min clearence required NEC 110.26 12/9/25 Please submit a revision of what is install, does not match plans......eliminated ac disconnect, wire size, Plans call for 100 amp breaker 80 amp installed. etc.
SOLAR ELECTRIC FINAL 12/17/2025 Disapproved - NO FEE MKRASKI
Note: 12/17/25 1. All wall and ceiling penitrations that were made must be sealed for garage fire seperation FBC R302.6 2. CT wiring must be protected and secured 3. Working space not met for subpanel, 3' min clearence required NEC 110.26 12/9/25 Please submit a revision of what is install, does not match plans......eliminated ac disconnect, wire size, Plans call for 100 amp breaker 80 amp installed. etc.
SOLAR ELECTRIC FINAL 12/09/2025 Disapproved - NO FEE JSTEWART
Note: Please submit a revision of what is install, does not match plans......eliminated ac disconnect, wire size, Plans call for 100 amp breaker 80 amp installed. etc.

Review History

Department Status Date In Date Out
BLD COMPLETE 12/12/2025 12/12/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
ELEC COMPLETE 12/12/2025 12/15/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 11/03/2025 11/03/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ELEC COMPLETE 11/03/2025 11/03/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ZON COMPLETE 11/03/2025 11/03/2025
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADMINISTRATIVE RESIDENTIAL ¤30.00 11/06/2025
INSPECTION - RESIDENTIAL ¤60.00 11/06/2025
SOLAR PLAN REVIEW ¤65.00 11/06/2025
SURCHARGE FS 533.721 ¤2.00 11/06/2025
SURCHARGE - FS 468.631 ¤2.33 11/06/2025
Fees Total Due: ¤0.00 Total Paid: ¤159.33