Permit #2025110301

Permit Details

Status: COED

Parcel Id: 03-12-31-1126-00000-2470
CONDITIONED SPACE: 3306 sqft
GARAGE: 614 sqft
OPENED PORCH (WITH ROOF) : 76 sqft
OPENED PORCH (WITH ROOF) : 208 sqft
Total Square Footage: 4204 sqft
Subdivision: 2334 - EVOLVE PALM COAST - SANDLAKE SUBDIVISION LOT 4
Job Phone: 813-917-1689
Location Address: 96 ARMOYAN DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 12/05/2025
NOC: RECORDED
Applicant name: SCOTT EVAN KEUNING
Owner: TAYLOR MORRISON OF FLORIDA INC

Address

1275 W GRANADA BLVD

ORMOND BEACH, FL 32174

Address

SUITE 3B

ORMOND BEACH, FL 32174

Lot: 247
Contracted Stated Job Value: ¤228,917.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

TAYLOR MORRISON OF FLORIDA INC
Status Location Address State License Number Phone
ACTIVE

7785 BAY MEADOWS WAY, SUITE 105

JACKSONVILLE, FL 32256

CBC1265083 (Exp: 08/31/2026) 813-917-1689

Sub Contractors

JOSEPH H STRADA JR
Status Location Address State License Number Phone
ACTIVE

3400 ST JOHNS PKWY

SANFORD, FL 32771

CAC043953 (Exp: 08/31/2026) 877-906-1113
JOSEPH HORATIO STRADA JR
Status Location Address State License Number Phone
ACTIVE

3400 ST JOHNS PARKWAY

SANFORD, FL 32771

EC13003715 (Exp: 08/31/2026) 877-906-1113
BENJAMIN MICHAEL RAY
Status Location Address Mailing Address State License Number Phone Fax
ACTIVE

6310 MABLETON PKWY

JACKSONVILLE, FL 32216

SUITE 1000

MABLETON, GA 30126

CFC1428415 (Exp: 08/31/2026) 904-861-5421 904-861-5426
CHASE RANDOLPH MASSEY
Status Location Address State License Number Phone
ACTIVE

10048 103RD ST

JACKSONVILLE, FL 32210

CCC1332486 (Exp: 08/31/2026) 904-248-1133

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 05/01/2026 APPROVED CVANSTRAHLEN
Note: 4/30/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1-FBCR M1303.1-HEAT STRIPS NOT MARKED ( mark doble ), please mark units out side and inside #1 and #2 #2-FBCR M1502.3-REMOVE SCREEN FROM DRYER VENT #3-P2804.6.1-14-requires water heater temperature and pressure (T&P) relief valve discharge pipes to be made of approved materials (copper, CPVC, galvanized steel), maintain the same diameter as the valve outlet, and flow by gravity. The pipe must terminate #4-M1502.4.7 Exhaust duct required. Where space for a clothes dryer is provided, an exhaust duct system shall be installed. Where the clothes dryer is not installed at the time of occupancy the exhaust duct shall be capped or plugged in the space in which it originates and identified and marked “future use.”
BLD - BUILDING FINAL 04/30/2026 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: Please fix items before next inspection #1-FBCR M1303.1-HEAT STRIPS NOT MARKED ( mark doble ), please mark units out side and inside #1 and #2 #2-FBCR M1502.3-REMOVE SCREEN FROM DRYER VENT #3-P2804.6.1-14-requires water heater temperature and pressure (T&P) relief valve discharge pipes to be made of approved materials (copper, CPVC, galvanized steel), maintain the same diameter as the valve outlet, and flow by gravity. The pipe must terminate #4-M1502.4.7 Exhaust duct required. Where space for a clothes dryer is provided, an exhaust duct system shall be installed. Where the clothes dryer is not installed at the time of occupancy the exhaust duct shall be capped or plugged in the space in which it originates and identified and marked “future use.”
U-CROSS CONNECTION 04/28/2026 APPROVED - AS NOTED BVEIGA
Note: NO/CC, IRR RECLAIM
ROW - FINAL APRON (AFTER POUR) 04/28/2026 APPROVED FSLADISH
Note: 4/28/26 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S AND/OR HOMEOWNER’S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ROW - FINAL INSPECTION 04/28/2026 APPROVED FSLADISH
Note: 4/28/26 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S AND/OR HOMEOWNER’S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
U -UTILITY RESIDENTIAL FINAL 04/28/2026 APPROVED BVEIGA
ROW- FINAL SURVEY/GRADING CERTIFICATION 04/27/2026 APPROVED FSLADISH
Note: 4/27/26 BASED ON THE ENGINEER SIGNED AND SEALED LGADC MEETING THE COPC MINIMUM REQUIREMENTS AT THE TIME OF THIS INSPECTION, I AM APPROVING THIS DOCUMENT. Effective 3/25/26, the ROW Field Survey requirement is no longer in effect for Final Lot Grading and Drainage Certification for new construction on subdivision and infill lots. All Final Lot Grading and Drainage Certificates for these projects will now be reviewed and approved only in the office. Field verification for the ROW-FIELD SURVEY will no longer be required as part of the standard approval process for these permit types.
ELECTRIC - EARLY POWER 03/06/2026 APPROVED CVANSTRAHLEN
Note: Inspector Notes from Inspection 2200 1-9-26 1. Emailed FPL at 8:43. 1/8/2026 - PREVIOUS INSPECTION NOTES 1-8-26 1. Protective pipe is not glued.
ROW- PRE-APRON (PRE-POUR) 02/27/2026 APPROVED FSLADISH
Note: 2/27/26 BUILDER REFER TO CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR BEFORE POURING. . IF FIBERGLASS OPTION IS USED, BUILDER REQUIRED TO USE 3000 PSI CONCRETE AT THE TIME OF THE INSPECTION READY TO POUR,IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK SITE FOR ANY STANDING WATER. ALSO VERIFY PIPE ELEVATION HAS NOT CHANGED. NO EXPANSION JOINTS ALLOWED, AT THE TIME OF THIS INSPECTION ALL MINIMUM COPC REQUIREMENTS ARE MET. BUILDER TO BE HELD RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
GRAVITY SEWER TEST 02/18/2026 APPROVED BTAYLOR
SEWER TIE IN 02/18/2026 APPROVED BTAYLOR
DRYWALL NAILING 02/02/2026 APPROVED BTAYLOR
BLD - BUILDING FINAL 02/02/2026 CANCELLED BY APPLICANT WEB
INSULATION 01/28/2026 APPROVED BTAYLOR
ALL ROUGH 01/21/2026 APPROVED BTAYLOR
ROOF VALLEY & METAL 01/12/2026 APPROVED MKRASKI
LATH/BRICK/ WATER BARRIER 01/09/2026 APPROVED BTAYLOR
Note: Inspector Notes from Inspection 2460 1-6-26 1. Need to add bolts in shear wall. Bolts are to be every 24". Inspector Notes from Inspection 2250 12-19-25 1. Need to post address.
ELECTRIC-TUG 01/09/2026 APPROVED - AS NOTED BTAYLOR
Note: 1-9-26 1. Emailed FPL at 8:43. 1/8/2026 - PREVIOUS INSPECTION NOTES 1-8-26 1. Protective pipe is not glued.
ELECTRIC-TUG 01/08/2026 Disapproved - NO FEE BTAYLOR
Note: 1-8-26 1. Protective pipe is not glued.
WALL SHEATHING 01/06/2026 APPROVED BTAYLOR
Note: Inspector Notes from Inspection 2250 12-19-25 1. Need to post address.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 01/06/2026 APPROVED - AS NOTED BTAYLOR
Note: 1-6-26 1. Need to add bolts in shear wall. Bolts are to be every 24". Inspector Notes from Inspection 2250 12-19-25 1. Need to post address.
WATER METER INSTALLATION REQUEST 12/23/2025 APPROVED CBOWERMASTER
MONOLITHIC SLAB 12/19/2025 APPROVED - AS NOTED BTAYLOR
Note: 12-19-25 1. Need to post address.
PLUMBING 1ST ROUGH UNDERGROUND 12/17/2025 APPROVED BTAYLOR
FORMBOARD SURVEY (OFFICE USE ONLY) 12/16/2025 APPROVED RRICKS

Review History

Department Status Date In Date Out
BADMIN INFORMATION 04/24/2026 04/24/2026
Note: Marked INFORMATION By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM submit the final and certificate together in one file
SW1 COMPLETE 12/15/2025 12/16/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 12/15/2025 12/15/2025
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
BLD COMPLETE 12/05/2025 12/11/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
SW1 COMPLETE 11/20/2025 11/26/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ENGIN1 COMPLETE 11/20/2025 11/21/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
SW1 HOLD 11/12/2025 11/12/2025
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Disregard previous comments about benchmark: Grading plan comments: - There shall be a minimum fall of 5% in the first 10' of the home. In the front and back yard based on the information provided water is flowing back towards the home. Structural Plan comments based on grading plan: - There are proposed elevations adjacent to the foundation that are being proposed more than 8" below the top of foundation based on SD2. Please ensure that where the proposed grade adjacent to the foundation drops more than 8" it is called out specifically on the structural drawings or has a separate section detail. Please feel free to call or email if there are any questions or concerns.
BLD COMPLETE 11/10/2025 11/17/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
CUSVC COMPLETE 11/10/2025 11/14/2025
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 11/10/2025 11/17/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 11/10/2025 11/12/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS CANCEL 11/10/2025 11/12/2025
LOCATE COMPLETE 11/10/2025 11/14/2025
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 11/10/2025 11/12/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 HOLD 11/10/2025 11/12/2025
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Grading plan comments: - There shall be a minimum fall of 5% in the first 10' of the home. In the front and back yard based on the information provided water is flowing back towards the home. - Please provide on-site benchmark. Structural Plan comments based on grading plan: - There are proposed elevations adjacent to the foundation that are being proposed more than 8" below the top of foundation based on SD2. Please ensure that where the proposed grade adjacent to the foundation drops more than 8" it is called out specifically on the structural drawings or has a separate section detail. Please feel free to call or email if there are any questions or concerns.
ZON COMPLETE 11/10/2025 11/12/2025
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
URB COMPLETE 11/10/2025 11/14/2025
Note: Released By: JOHN BEAUDET - (386)986-2456 - JBEAUDET@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 05/01/2026
FC IMPACT FEE EMS ¤62.00 12/05/2025
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 12/05/2025
FC IMPACT FEE LIBRARY ¤268.00 12/05/2025
FIRE RES IMPACT FEE 10-25 ¤942.00 12/05/2025
WATER METER W/OUT TAP ¤965.03 12/05/2025
PARKS IMPACT FEE 10-25 ¤3,164.00 12/05/2025
RSI DRIVEWAY AFTER POUR ¤16.25 12/05/2025
RSE DRIVE PRE POUR INSPECTION ¤32.50 12/05/2025
RSI FIELD SURVEY INSPECTION ¤48.75 12/05/2025
RSI FORMBOARD REVIEW ¤16.25 12/05/2025
RSI PLAN REVIEW NEW ¤48.75 12/05/2025
RSI FNL SURVEY/GRADING CERT ¤48.75 12/05/2025
RSI ROW FINAL INSPECTION ¤16.25 12/05/2025
SURCHARGE FS 533.721 ¤22.47 12/05/2025
SURCHARGE - FS 468.631 ¤33.70 12/05/2025
TRANSP RES IMPACT FEE 10-25 ¤12,463.62 12/05/2025
WASTEWATER PERM INSPECTION ¤80.00 12/05/2025
WASTEWATER PERM REVIEW ¤25.00 12/05/2025
SEWER CAPITAL FACILITY ¤3,613.92 12/05/2025
WATER CAPITAL FACILITY FEE ¤3,039.48 12/05/2025
WATER PERMIT INSPECTION ¤40.00 12/05/2025
WATER PERMIT REVIEW ¤25.00 12/05/2025
SITE PLAN 30 ¤30.00 12/05/2025
WATER-METER ¤965.03 12/05/2025
WATER- TURN ON ¤50.00 12/05/2025
WATER- TURN ON ¤50.00 12/05/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 12/05/2025
INSPECTION - RESIDENTIAL ¤1,727.00 12/05/2025
PLAN REVIEW - RESIDENTIAL ¤489.84 12/05/2025
Fees Total Due: ¤0.00 Total Paid: ¤28,571.59