I want to search for...
Permit #2025110361
Permit Details
Status: INSPECT
| Parcel Id: 07-11-31-7027-00020-0090 |
| Block: 00020 |
| Subdivision: 2128 - SECTION 27-WYNNFIELD |
| Job Phone: 386-279-0197 |
| Location Address: 12 WOODSTON LN |
| Type: PO - POOL |
| Issue Date: 12/01/2025 |
| NOC: RECORDED |
| Applicant name: BRIAN ANTHONY CROWE |
| Owner: LAND TRUST SERVICE CORP TRUSTEE |
|
Address PO BOX 547945 ORLANDO, FL 32854 |
| Lot: 0090 |
| Contracted Stated Job Value: ¤113,538.00 |
| Job Description: SWIMMING POOL WITH SCREEN ENCLOSURE |
| Type: CN |
Contractor
EXQUISITE POOL AND SPA
| Status | Location Address | State License Number | Phone |
| ACTIVE |
1661 RICHLAND AVE , |
CPC1461059 (Exp: 08/31/2026) | 386-279-0197 |
Sub Contractors
JEFFREY ADAM MCGREGOR
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1312 YORKTOWN STREET DELAND , FL 32724 |
EC13005662 (Exp: 08/31/2026) | 386-736-7475 | 386-785-1503 |
JOHN LEROY HODGINS
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2020 COUNTRY FARMS RD PORT ORANGE, FL 32128 |
CGC1507254 (Exp: 08/31/2026) | 386-547-2998 | 386-788-4028 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 05/21/2026 | Disapproved - NO FEE | TPOLACEK |
| Note: 05-21-26 TPOLACEK***PLEASE SEE ATTACHED PHOTO FOR REFERENCE. THERE IS A LOW AREA IN BACK THAT WILL HOLD DRAINAGE FROM MOVING TO FRONT ROADSIDE SWALE/ 4/30/2026 - PREVIOUS INSPECTION NOTES 04-30-26 TPOLACEK*** FINAL SURVEY INDICATES THERE IS NOT A .30 FALL FROM THE FFE OF POOL DECK INTO DRAINAGE CONVEYANCE. INSPECTOR WALKED SITE TO CONFIRM AND BUILDER NEEDS TO REGRADE FROM THE BACK LEFT CORNER OF POOL DECK AROUND RIGHT SIDE OUT TO SWALE AS THERE IS NN SWALE CREATED AND THERE ARE HIGHS AND LOWS THAT WITH NOT ALLOW DRAINAGE TO WORK AS APPROVED SITE PLAN INDICATED. Finished Floor Elevations (FFE): Draining onto adjacent properties will not be allowed Section 300.01 C(6) V-16 6) Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Draining onto adjacent properties will not be allowed outside of the platted 5’ drainage easement.Section 300.01 C(6) V-16 Finished Floor Elevations (FFE):REAR YARD DRAINAGE Section 300.01 D(6) V-17 6) The top of slope of “W” swales along the property lines shall be a minimum of 0.30 of a foot higher than the toe of slope. Section 300.01 D(6) V-17 Finished Floor Elevations (FFE):REAR YARD DRAINAGE Section 300.01 D(4) V-17 4) Positive fall is considered to be 0.10 of a foot every 20 feet. Section 300.01 D(4) V-17 | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 04/30/2026 | Disapproved - NO FEE | TPOLACEK |
| Note: 04-30-26 TPOLACEK*** FINAL SURVEY INDICATES THERE IS NOT A .30 FALL FROM THE FFE OF POOL DECK INTO DRAINAGE CONVEYANCE. INSPECTOR WALKED SITE TO CONFIRM AND BUILDER NEEDS TO REGRADE FROM THE BACK LEFT CORNER OF POOL DECK AROUND RIGHT SIDE OUT TO SWALE AS THERE IS NN SWALE CREATED AND THERE ARE HIGHS AND LOWS THAT WITH NOT ALLOW DRAINAGE TO WORK AS APPROVED SITE PLAN INDICATED. Finished Floor Elevations (FFE): Draining onto adjacent properties will not be allowed Section 300.01 C(6) V-16 6) Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Draining onto adjacent properties will not be allowed outside of the platted 5’ drainage easement.Section 300.01 C(6) V-16 Finished Floor Elevations (FFE):REAR YARD DRAINAGE Section 300.01 D(6) V-17 6) The top of slope of “W” swales along the property lines shall be a minimum of 0.30 of a foot higher than the toe of slope. Section 300.01 D(6) V-17 Finished Floor Elevations (FFE):REAR YARD DRAINAGE Section 300.01 D(4) V-17 4) Positive fall is considered to be 0.10 of a foot every 20 feet. Section 300.01 D(4) V-17 | |||
| ELECTRIC AND ALARM | 03/10/2026 | Approval - Private Provider | PPROVIDER |
| POOL DECK | 02/11/2026 | Approval - Private Provider | PPROVIDER |
| ROW- PROJECT STATUS | 01/20/2026 | Status Check | TPOLACEK |
| Note: 01-20-26 INSPECTOR RESULTED WRONG PROJECT STATUS WITH RESULTS OF THE SITE VISIT ON 01-12-26 HERE ARE THE NOTES FROM THE VISIT. I WILL ALSO ATTACH THE PHOTOS 01-12-26 TPOLACEK*** CHECKED SWALE AND CULVERT. BUILDER HAS ALREADY INSTALLED TEMPORARY PIPE AND FILL IN SWALE, DRIVEWAY CULVERT HAS SEDIMENT FROM PUMPING POOL AND DISCHARGE LINE WAS RUN STRAIGHT INTO CULVERT. I EXPLAINED TO WORKER ON SITE THAT THE DISCHARGE LINE MUST BE RUN AT LEAST 20' FROMT ROAD TO ALLOW SEDIMENT TO FILTER INTO GRASS NOT CULVERT. BUILDER WILL BE RESPONSIBLE FOR MAKING SURE ALL SEDIMENT IS REMOVED FROM CULVERT AT THE TIME OF THE ROW FINAL. Note to inspector please inspect right of way for damage in the swale prior to pool constructions please see Parren for any questions. Contractor contact 407-848-4704 | |||
| STEEL AND GROUND | 12/30/2025 | Approval - Private Provider | PPROVIDER |
| POOL FINAL | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | |||
| Note: 5/21/2026 - PREVIOUS INSPECTION NOTES 05-21-26 TPOLACEK***PLEASE SEE ATTACHED PHOTO FOR REFERENCE. THERE IS A LOW AREA IN BACK THAT WILL HOLD DRAINAGE FROM MOVING TO FRONT ROADSIDE SWALE/ 4/30/2026 - PREVIOUS INSPECTION NOTES 04-30-26 TPOLACEK*** FINAL SURVEY INDICATES THERE IS NOT A .30 FALL FROM THE FFE OF POOL DECK INTO DRAINAGE CONVEYANCE. INSPECTOR WALKED SITE TO CONFIRM AND BUILDER NEEDS TO REGRADE FROM THE BACK LEFT CORNER OF POOL DECK AROUND RIGHT SIDE OUT TO SWALE AS THERE IS NN SWALE CREATED AND THERE ARE HIGHS AND LOWS THAT WITH NOT ALLOW DRAINAGE TO WORK AS APPROVED SITE PLAN INDICATED. Finished Floor Elevations (FFE): Draining onto adjacent properties will not be allowed Section 300.01 C(6) V-16 6) Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Draining onto adjacent properties will not be allowed outside of the platted 5’ drainage easement.Section 300.01 C(6) V-16 Finished Floor Elevations (FFE):REAR YARD DRAINAGE Section 300.01 D(6) V-17 6) The top of slope of “W” swales along the property lines shall be a minimum of 0.30 of a foot higher than the toe of slope. Section 300.01 D(6) V-17 Finished Floor Elevations (FFE):REAR YARD DRAINAGE Section 300.01 D(4) V-17 4) Positive fall is considered to be 0.10 of a foot every 20 feet. Section 300.01 D(4) V-17 | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | |||
| ROW - FINAL INSPECTION | |||
| U -UTILITY RESIDENTIAL FINAL |
Review History
| Department | Status | Date In | Date Out |
| BADMIN | INFORMATION | 03/09/2026 | 03/09/2026 |
| Note: Marked INFORMATION By: JAZMIN ROSARIO - - JROSARIO@PALMCOASTGOV.COM missing inspection code on report | |||
| ZON | COMPLETE | 11/25/2025 | 11/25/2025 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 11/25/2025 | 12/01/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| RSI | COMPLETE | 11/25/2025 | 11/25/2025 |
| Note: Released By: FRANK SLADISH - (386)871-6113 - FSLADISH@PALMCOASTGOV.COM | |||
| ZON | HOLD | 11/19/2025 | 11/19/2025 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM repeat comment Pool deck width missing on site plan/survey | |||
| ELEC | HOLD | 11/19/2025 | 11/19/2025 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Submit pool bonding detail. NEC 2020 680.26 | |||
| BLD | COMPLETE | 11/19/2025 | 11/25/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| RSI | COMPLETE | 11/19/2025 | 11/21/2025 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| BFLOOD | CANCEL | 11/12/2025 | 11/13/2025 |
| BLD | COMPLETE | 11/12/2025 | 11/18/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 11/12/2025 | 11/17/2025 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Submit pool bonding detail. NEC 2020 680.26 | |||
| MECH | COMPLETE | 11/12/2025 | 11/13/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| RSI | COMPLETE | 11/12/2025 | 11/12/2025 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | HOLD | 11/12/2025 | 11/12/2025 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Pool deck width missing on site plan/survey |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 12/01/2025 |
| ADMINISTRATIVE - RESID PP | ¤75.00 | 12/01/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤88.92 | 12/01/2025 |
| RSI FIELD SURVEY INSPECTION | ¤48.75 | 12/01/2025 |
| RSI PLAN REVIEW NEW | ¤48.75 | 12/01/2025 |
| RSI FNL SURVEY/GRADING CERT | ¤48.75 | 12/01/2025 |
| RSI ROW FINAL INSPECTION | ¤16.25 | 12/01/2025 |
| SURCHARGE FS 533.721 | ¤2.00 | 12/01/2025 |
| SURCHARGE - FS 468.631 | ¤2.91 | 12/01/2025 |
| SITE PLAN 30 | ¤30.00 | 12/01/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤391.33 |