I want to search for...

Permit #2025110385

Permit Details

Status: INSPECT

Parcel Id: 35-11-31-4075-00000-0860
CONDITIONED SPACE: 3305 sqft
GARAGE: 582 sqft
OPENED PORCH (WITH ROOF) : 619 sqft
Total Square Footage: 4506 sqft
Block: 00000
Subdivision: -
Job Phone: 386-236-4133
Location Address: 37 DEL PALMA DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 12/17/2025
NOC: RECORDED
Applicant name: LEONARDO CIRO SANCLEMENTE
Owner: VOLUSIA RESIDENTIAL CONSTRUCTION, LLC

Address

2379 BEVILLE RD

DAYTONA BEACH, FL 32119

Lot: 0860
Contracted Stated Job Value: ¤335,724.00
Job Description: single family residence.
Type: CN

Contractor

VOLUSIA RESIDENTIAL CONSTRUCTION, LLC
Status Location Address State License Number Phone
ACTIVE

2379 BEVILLE RD

DAYTONA BEACH, FL 32119

CBC1262114 (Exp: 08/31/2026) 386-236-4133

Sub Contractors

STEPHEN COURTEAUX
Status Location Address State License Number Phone Fax
ACTIVE

85 North Yonge Street

Ormond Beach, FL 32174

EC13001748 (Exp: 08/31/2026) (386) 672-4900 386-676-7472
HUGH MACDONALD
Status Location Address State License Number Phone
ACTIVE

10825 TOM FOLSOM ROAD, SUITE A

THONOTOSASSA, FL 33592

CCC1329562 (Exp: 08/31/2026) 813-986-4968
BRENT JAMES STURGELL
Status Location Address State License Number Phone
ACTIVE

651 CARSWELL AVE

HOLLY HILL , FL 32117

CAC1822599 (Exp: 08/31/2026) 386-252-1878
HARLEY M BRYAN
Status Location Address State License Number Phone
ACTIVE

5223 EDGEWOOD CT

ORMOND BEACH, FL 32174

LI26657 (Exp: 08/31/2028) 386-463-2700
GARY WAYNE EVERS
Status Location Address State License Number Phone Fax
ACTIVE

PO BOX 740106

ORANGE CITY, FL 32763

CFC050566 (Exp: 08/31/2026) 386-775-0909 386-775-0918

Inspection History

Type Request Date Result Inspector
ROW- PRE-APRON (PRE-POUR) 06/01/2026 APPROVED FSLADISH
Note: 6/1/26 THIS PREPOUR INSPECTION IS AN ADDITIONAL INSPECTION FOR THE SIDEWALK POUR. AT THE TIME OF THE INSPECTION PREPOUR AREA IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD REMOVE ALL WATER AND CHECK COMPACTION BEFORE POURING CONCRETE. 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED IS REQUIRED. PLEASE REVIEW CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. NO EXPANSION JOINTS ALLOWED. Inspector Notes from Inspection 9270 5/27/26 YOU ARE APPROVED TO LAY PAVERS AS OF THIS INSPECTION. ***INSPECTORS NOTE. AN ADDITIONAL PREPOUR INSPECTION WILL BE REQUIRED WHEN BUILDER FORMS SIDEWALK.*** Inspector Notes from Inspection 9271 5/20/26 AT THE TIME OF THIS INSPECTION YOU ARE APPROVED TO POUR YOUR PAVER RESTRAINTS. **** DO NOT LAY ANY PAVERS UNTIL AFTER A SECONDARY SPREAD AND COMPACTION INSPECTION HAS BEEN SCHEDULED AND PASSED**** BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS
ROW- PRE-APRON (PRE-POUR) 05/27/2026 APPROVED - AS NOTED FSLADISH
Note: 5/27/26 YOU ARE APPROVED TO LAY PAVERS AS OF THIS INSPECTION. ***INSPECTORS NOTE. AN ADDITIONAL PREPOUR INSPECTION WILL BE REQUIRED WHEN BUILDER FORMS SIDEWALK.*** Inspector Notes from Inspection 9271 5/20/26 AT THE TIME OF THIS INSPECTION YOU ARE APPROVED TO POUR YOUR PAVER RESTRAINTS. **** DO NOT LAY ANY PAVERS UNTIL AFTER A SECONDARY SPREAD AND COMPACTION INSPECTION HAS BEEN SCHEDULED AND PASSED**** BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS
ROW- PRE-APRON (PRE-POUR) 05/20/2026 PARTIALLY APPROVED FSLADISH
Note: 5/20/26 SPOKE WITH WILL CM AND LET HIM KNOW THAT THERE WERE A FEW ISSUES. THE SITE PLAN AND GRADING PLAN BOTH INDICATE A PAVER APROPN WHICH IS NOT ALLOWED IN THIS SUBDIVISION. HE INDICATED THAT THEY WERE POURING A CONCRETE APRON WHICH IS WHAT IS REQUIRED. THERE IS NO SIDEWALK INDICATED ON EITHER SITE PLAN OR LDAGC. THE PAVER DETAIL SHEET OPTION CHOSEN IS NOT THE CORRECT OPTION FOR THIS SITE. THE SIDEWALK WAS NOT FORMED ALL THE WAY TO PROPERTY LINE, WHICH I LET HIM KNOW VIA APPLICANT NOTES OR COMMUNICATING WITH INSPECTOR LETTING US KNOW YOU NEED TO STILL ACCESS SITE IS NOT A PROBLEM WE CAN ADD AN ADDITIONAL PREPOUR INSPECTION WHEN THEY ARE READY TO POUR THE SIDEWALK. LET HIM KNOW THAT THE FORMBOARD ACROSS THE FRONT PORTION OF THE APRON NEEDS TO BE REMOVED BEFORE POURING TO ALLOW FOR A MONO POUR. I AM GOING TO GO AHEAD AND PARTIALLY APPROVE BUILDER TO POUR DRIVEWAY, SIDEWALK PORTION AND PAVER RESTRAINTS AT THIS TIME. PHOTO FOR REFERENCE. AT THE TIME OF THIS INSPECTION YOU ARE PARTIALLY APPROVED TO POUR YOUR DRIVEWAY APRON, SIDEWALK AND PAVER RESTRAINTS. **** DO NOT LAY ANY PAVERS UNTIL AFTER A SECONDARY SPREAD AND COMPACTION INSPECTION HAS BEEN SCHEDULED AND PASSED**** BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS
ROW- PAVER RESTRAINTS 05/20/2026 APPROVED - AS NOTED FSLADISH
Note: 5/20/26 AT THE TIME OF THIS INSPECTION YOU ARE APPROVED TO POUR YOUR PAVER RESTRAINTS. **** DO NOT LAY ANY PAVERS UNTIL AFTER A SECONDARY SPREAD AND COMPACTION INSPECTION HAS BEEN SCHEDULED AND PASSED**** BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS
ELECTRIC - EARLY POWER 05/14/2026 APPROVED CVANSTRAHLEN
Note: 5/13/2026 - PREVIOUS INSPECTION NOTES 5/13/26 1. All wires need to be properly safed off in boxes. Need to have wire nuts on the ends as well NEC 440.14 2. Surge protection should be in meter/main only NEC 230.67
ELECTRIC - EARLY POWER 05/13/2026 Disapproved - NO FEE MCONTRYMAN
Note: 5/13/26 1. All wires need to be properly safed off in boxes. Need to have wire nuts on the ends as well NEC 440.14 2. Surge protection should be in meter/main only NEC 230.67
DRYWALL NAILING 04/13/2026 APPROVED CVANSTRAHLEN
INSULATION 04/08/2026 APPROVED CVANSTRAHLEN
Note: 4/7/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspectionn #1- missing bafflers around the sotfit area of the building #2-missing measurement marks for blow insulation marks main area of the ceiling #3- need solid blocking where moved drayer vent for 2nd floor #4-please mark flex duck , Missing # size 4/6/2026 - PREVIOUS INSPECTION NOTES FBC[A] 110.5-ACCESS FOR INSPECTION - SPECIAL INSTRUCTIONS Inspector Notes from Inspection 2420 Please fix items before next inspection #1-please provided eligible energy cals layout , #2-Please mark duct flex with size labels #3- some duct work pipe look crush first floor #4- replace electrical outlet box room over garage #5-Missing Fl Approval # on windows spector Notes from Inspection 2460 1. Garage wall on left where floors trusses are sitting is missing anchoring/plywood. See Plans (marked). *Will check at Rough* 3/6/2026 - PREVIOUS INSPECTION NOTES 3/3/2026 - PREVIOUS INSPECTION NOTES No ready
INSULATION 04/07/2026 Disapproved - NO FEE CVANSTRAHLEN
Note: Please fix items before next inspectionn #1- missing bafflers around the sotfit area of the building #2-missing measurement marks for blow insulation marks main area of the ceiling #3- need solid blocking where moved drayer vent for 2nd floor #4-please mark flex duck , Missing # size 4/6/2026 - PREVIOUS INSPECTION NOTES FBC[A] 110.5-ACCESS FOR INSPECTION - SPECIAL INSTRUCTIONS Inspector Notes from Inspection 2420 Please fix items before next inspection #1-please provided eligible energy cals layout , #2-Please mark duct flex with size labels #3- some duct work pipe look crush first floor #4- replace electrical outlet box room over garage #5-Missing Fl Approval # on windows spector Notes from Inspection 2460 1. Garage wall on left where floors trusses are sitting is missing anchoring/plywood. See Plans (marked). *Will check at Rough* 3/6/2026 - PREVIOUS INSPECTION NOTES 3/3/2026 - PREVIOUS INSPECTION NOTES No ready
LATH/BRICK/ WATER BARRIER 04/07/2026 APPROVED CVANSTRAHLEN
Note: 4/6/2026 - PREVIOUS INSPECTION NOTES FBC[A] 110.5-ACCESS FOR INSPECTION - SPECIAL INSTRUCTIONS Inspector Notes from Inspection 2420 Please fix items before next inspection #1-please provided eligible energy cals layout , #2-Please mark duct flex with size labels #3- some duct work pipe look crush first floor #4- replace electrical outlet box room over garage #5-Missing Fl Approval # on windows spector Notes from Inspection 2460 1. Garage wall on left where floors trusses are sitting is missing anchoring/plywood. See Plans (marked). *Will check at Rough* 3/6/2026 - PREVIOUS INSPECTION NOTES 3/3/2026 - PREVIOUS INSPECTION NOTES No ready
LATH/BRICK/ WATER BARRIER 04/06/2026 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: FBC[A] 110.5-ACCESS FOR INSPECTION - SPECIAL INSTRUCTIONS Inspector Notes from Inspection 2420 Please fix items before next inspection #1-please provided eligible energy cals layout , #2-Please mark duct flex with size labels #3- some duct work pipe look crush first floor #4- replace electrical outlet box room over garage #5-Missing Fl Approval # on windows spector Notes from Inspection 2460 1. Garage wall on left where floors trusses are sitting is missing anchoring/plywood. See Plans (marked). *Will check at Rough* 3/6/2026 - PREVIOUS INSPECTION NOTES 3/3/2026 - PREVIOUS INSPECTION NOTES No ready
INSULATION 04/06/2026 Disapproved - NO FEE CVANSTRAHLEN
Note: FBC[A] 110.5-ACCESS FOR INSPECTION - SPECIAL INSTRUCTIONS Inspector Notes from Inspection 2420 Please fix items before next inspection #1-please provided eligible energy cals layout , #2-Please mark duct flex with size labels #3- some duct work pipe look crush first floor #4- replace electrical outlet box room over garage #5-Missing Fl Approval # on windows spector Notes from Inspection 2460 1. Garage wall on left where floors trusses are sitting is missing anchoring/plywood. See Plans (marked). *Will check at Rough* 3/6/2026 - PREVIOUS INSPECTION NOTES 3/3/2026 - PREVIOUS INSPECTION NOTES No ready
ALL ROUGH 03/27/2026 APPROVED - AS NOTED CVANSTRAHLEN
Note: Please fix items before next inspection #1-please provided eligible energy cals layout , #2-Please mark duct flex with size labels #3- some duct work pipe look crush first floor #4- replace electrical outlet box room over garage #5-Missing Fl Approval # on windows spector Notes from Inspection 2460 1. Garage wall on left where floors trusses are sitting is missing anchoring/plywood. See Plans (marked). *Will check at Rough* 3/6/2026 - PREVIOUS INSPECTION NOTES 3/3/2026 - PREVIOUS INSPECTION NOTES No ready
ELECTRIC-TUG 03/27/2026 APPROVED CVANSTRAHLEN
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/19/2026 APPROVED - AS NOTED HCAMACHO
Note: 1. Garage wall on left where floors trusses are sitting is missing anchoring/plywood. See Plans (marked). *Will check at Rough* 3/6/2026 - PREVIOUS INSPECTION NOTES 3/3/2026 - PREVIOUS INSPECTION NOTES No ready
ROOF VALLEY & METAL 03/06/2026 APPROVED CVANSTRAHLEN
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/06/2026 CANCELLED BY APPLICANT CVANSTRAHLEN
Note: 3/3/2026 - PREVIOUS INSPECTION NOTES No ready
WALL SHEATHING 03/03/2026 APPROVED CVANSTRAHLEN
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/03/2026 Disapproved - NO FEE CVANSTRAHLEN
Note: No ready
ROOF SHEATHING 03/03/2026 APPROVED CVANSTRAHLEN
TIE BEAM / LINTEL 02/05/2026 APPROVED BTAYLOR
MONOLITHIC SLAB 01/27/2026 APPROVED BTAYLOR
PLUMBING 1ST ROUGH UNDERGROUND 01/23/2026 APPROVED BTAYLOR
GRAVITY SEWER TEST 01/23/2026 APPROVED BTAYLOR
SEWER TIE IN 01/23/2026 APPROVED BTAYLOR
FORMBOARD SURVEY (OFFICE USE ONLY) 01/22/2026 APPROVED TDOAK
WATER METER INSTALLATION REQUEST 01/12/2026 APPROVED CBOWERMASTER
U-CROSS CONNECTION
BLD - BUILDING FINAL
ROW - FINAL APRON (AFTER POUR)
ROW- FINAL SURVEY/GRADING CERTIFICATION
ROW - FINAL INSPECTION
U -UTILITY RESIDENTIAL FINAL

Review History

Department Status Date In Date Out
SW1 COMPLETE 01/22/2026 01/22/2026
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 01/22/2026 01/22/2026
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ZON COMPLETE 12/02/2025 12/02/2025
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
BLD COMPLETE 12/02/2025 12/08/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
ELEC COMPLETE 12/02/2025 12/09/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
SW1 COMPLETE 12/02/2025 12/09/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
SW1 COMPLETE 11/26/2025 11/26/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM My apologies - 88 Datum is referenced in notes. Note: During construction please ensure that the formboards and slab is no higher than what it proposed to remain compliant with COPC standards.
GAS COMPLETE 11/18/2025 11/19/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ZON HOLD 11/18/2025 11/18/2025
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM FLoor plan the storage area needs to be closed off to the garage so it doesn't exceed the garage depth please go all the way up
SW1 HOLD 11/18/2025 11/26/2025
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM All elevations shall be in NAVD88 Datum. Please depict this on grading plan.
BLD COMPLETE 11/18/2025 11/25/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
ELEC COMPLETE 11/18/2025 11/19/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 11/12/2025 11/18/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
CUSVC COMPLETE 11/12/2025 11/14/2025
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 11/12/2025 11/17/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 11/12/2025 11/13/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS HOLD 11/12/2025 11/13/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide location and size of propane tank on site plan. Provide setbacks to property lines and distance from tank to house
LOCATE COMPLETE 11/12/2025 11/14/2025
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 11/12/2025 11/18/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 HOLD 11/12/2025 11/17/2025
Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM 1) LEFT DRAINAGE PATTERN MUST BE ON THE PROPERTY LINE SO WHEN LOT85 IS BUILT THEY WILL HAVE A COMMON SWALE. 2) LEFT SIDE DRAINAGE PATTERN WILL NOT FLOW CORRECTLY MUST HAVE POSITIVE FALL EVERY 20' SO WATER WILL NOT SIT ON LOT. 3) MUST HAVE FFE OF GARAGE AND ALL PATIOS AND ALL NEED TO BE SLOPED AWAY FROM HOUSE 2%.
ZON HOLD 11/12/2025 11/14/2025
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Floor plan :Garages shall have a maximum depth of 30', please adjust plans accordingly.
URB COMPLETE 11/12/2025 11/17/2025
Note: Released By: JOHN BEAUDET - (386)986-2456 - JBEAUDET@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
FC IMPACT FEE EMS ¤62.00 12/17/2025
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 12/17/2025
FC IMPACT FEE LIBRARY ¤268.00 12/17/2025
FIRE RES IMPACT FEE 10-25 ¤942.00 12/17/2025
WATER METER W/OUT TAP ¤965.03 12/17/2025
PARKS IMPACT FEE 10-25 ¤3,164.00 12/17/2025
RSI DRIVEWAY AFTER POUR ¤16.25 12/17/2025
RSE DRIVE PRE POUR INSPECTION ¤32.50 12/17/2025
RSI FIELD SURVEY INSPECTION ¤48.75 12/17/2025
RSI FORMBOARD REVIEW ¤16.25 12/17/2025
RSI PLAN REVIEW NEW ¤48.75 12/17/2025
RSI FNL SURVEY/GRADING CERT ¤48.75 12/17/2025
RSI ROW FINAL INSPECTION ¤16.25 12/17/2025
SCHOOL BOARD IMPACT FEE RES ¤5,450.00 12/17/2025
SURCHARGE FS 533.721 ¤23.21 12/17/2025
SURCHARGE - FS 468.631 ¤34.82 12/17/2025
TRANSP RES IMPACT FEE 10-25 ¤12,459.85 12/17/2025
WASTEWATER PERM INSPECTION ¤80.00 12/17/2025
WASTEWATER PERM REVIEW ¤25.00 12/17/2025
SEWER CAPITAL FACILITY ¤3,893.17 12/17/2025
WATER CAPITAL FACILITY FEE ¤3,319.34 12/17/2025
WATER PERMIT REVIEW ¤25.00 12/17/2025
SITE PLAN 30 ¤30.00 12/17/2025
WATER- TURN ON ¤50.00 12/17/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 12/17/2025
INSPECTION - RESIDENTIAL ¤1,784.75 12/17/2025
PLAN REVIEW - RESIDENTIAL ¤506.22 12/17/2025
REINSPECTION RESIDENTIAL ¤40.00
CONTRACTOR CHANGE ¤20.00
Fees Total Due: ¤60.00 Total Paid: ¤33,557.89