Permit #2025110396
Permit Details
Status: COED
| Parcel Id: 04-11-30-5571-00000-1780 |
| CONDITIONED SPACE: 1707 sqft |
| GARAGE: 481 sqft |
| OPENED PORCH (WITH ROOF) : 64 sqft |
| OPENED PORCH (WITH ROOF) : 220 sqft |
| Total Square Footage: 2472 sqft |
| Subdivision: 2366 - SOMERSET SUBDIVISION PH 2 |
| Job Phone: 904-596-6645 |
| Location Address: 102 TEA OLIVE DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 12/08/2025 |
| NOC: RECORDED |
| Applicant name: MICHAEL T HOLDER |
| Owner: KB HOME JACKSONVILLE LLC |
|
Address 10475 FORTUNE PARKWAY JACKSONVILLE, FL 32256 |
|
Address SUITE 100 JACKSONVILLE, FL 32256 |
| Lot: 178 |
| Contracted Stated Job Value: ¤140,000.00 |
| Job Description: SINGLE FAMILY DWELLING |
| Type: CN |
Contractor
KB HOME JACKSONVILLE, LLC
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
10475 FORTUNE PKWY JACKSONVILLE, FL 32256 |
SUITE 100 JACKSONVILLE, FL 32256 |
CGC1509034 (Exp: 08/31/2026) | 904-596-6645 |
Sub Contractors
LARRY WILLIAMS
| Status | Location Address | State License Number | Phone |
| ACTIVE |
1750 EMERSON ST JACKSONVILLE, FL 32207 |
LI45034 (Exp: 08/31/2026) | 904-721-5431 |
BOBBY WAYNE CAMPBELL
| Status | Location Address | State License Number | Phone |
| ACTIVE |
117 GUTHRIE ROAD GREEN COVE SPRINGS, FL 32043 |
CCC1326752 (Exp: 08/31/2026) | 904-200-1600 |
JAMES E LINTON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
200 COLLEGE DR ORANGE PARK, FL 32065 |
EC0001152 (Exp: 08/31/2026) | 904-272-0272 |
COREY MICHAEL TENNANT
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3370 AGRICULTURAL CNETER DR ST AUGUSTINE, FL 32092 |
CAC1819063 (Exp: 08/31/2026) | 904-829-8898 |
BENJAMIN MICHAEL RAY
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| ACTIVE |
6310 MABLETON PKWY JACKSONVILLE, FL 32216 |
SUITE 1000 MABLETON, GA 30126 |
CFC1428415 (Exp: 08/31/2026) | 904-861-5421 | 904-861-5426 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROW - FINAL APRON (AFTER POUR) | 03/26/2026 | APPROVED | EMADISON |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW - FINAL INSPECTION | 03/26/2026 | APPROVED | EMADISON |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| U -UTILITY RESIDENTIAL FINAL | 03/26/2026 | FINAL APPROVED | BWRIGHT |
| Note: Inspector Notes from Inspection 9035 No CC. IRR with reuse water. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 03/25/2026 | APPROVED | TPOLACEK |
| Note: BASED ON THE STAMPED AND SIGNED LGDC AND FINAL SURVEY I AM APPROVING THE INSPECTION | |||
| BLD - BUILDING FINAL | 03/19/2026 | FINAL APPROVED | JSTEWART |
| Note: 3/16/2026 - PREVIOUS INSPECTION NOTES 1. Locking caps on outside unit loose. FBCR M1411.8 2. Exterior outlets on rear of house not GFCI protected. NEC 210.8 3. Heat strip on unit marked, but wrong breaker installed. | |||
| BLD - BUILDING FINAL | 03/16/2026 | Disapproved - NO FEE | PKNAPIK |
| Note: 1. Locking caps on outside unit loose. FBCR M1411.8 2. Exterior outlets on rear of house not GFCI protected. NEC 210.8 3. Heat strip on unit marked, but wrong breaker installed. | |||
| U-CROSS CONNECTION | 03/16/2026 | APPROVED - AS NOTED | BVEIGA |
| Note: No CC. IRR with reuse water. | |||
| ELECTRIC - EARLY POWER | 03/02/2026 | APPROVED | JSTEWART |
| Note: Inspector Notes from Inspection 2200 Authorize release of email. | |||
| ROW- PRE-APRON (PRE-POUR) | 02/10/2026 | APPROVED - AS NOTED | TPOLACEK |
| Note: 02-10-26 TPOLACEK*** ON THE RIGHT SIDE THERE IS NOT 6" ALONG FORM BAORDS. SPOKE WITH CM ON SITE AND THEY ARE HAVING THE CREW FIX THE ISSUE WHEN THEY FIX THE BOARD AT #94 APPROVING AS NOTED. AT THE TIME OF THE INSPECTION READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. . TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, IN THE UPCOMING MONTHS THE DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS WILL BE REQUIRED TO BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. YOU WILL RECEIVE A NEWS BLAST WHEN THIS BECOMES NECESSARY | |||
| DRYWALL NAILING | 02/03/2026 | APPROVED | JSTEWART |
| Note: 2/2/2026 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2490 Previous Notes not rectified...... 5. Please secure switch holding box to stud for pantry Light. NEC 314.23(B) 7. Underground romex for Island needs to be ran thru conduit, and secured. Per plan Electricians onsite for above. Will Check At drywall Nailing, will need completed to Move forward.. | |||
| DRYWALL NAILING | 02/02/2026 | CANCELLED BY APPLICANT | JSTEWART |
| Note: Inspector Notes from Inspection 2490 Previous Notes not rectified...... 5. Please secure switch holding box to stud for pantry Light. NEC 314.23(B) 7. Underground romex for Island needs to be ran thru conduit, and secured. Per plan Electricians onsite for above. Will Check At drywall Nailing, will need completed to Move forward.. | |||
| INSULATION | 01/30/2026 | APPROVED - AS NOTED | JSTEWART |
| Note: Previous Notes not rectified...... 5. Please secure switch holding box to stud for pantry Light. NEC 314.23(B) 7. Underground romex for Island needs to be ran thru conduit, and secured. Per plan Electricians onsite for above. Will Check At drywall Nailing, will need completed to Move forward.. | |||
| LATH/BRICK/ WATER BARRIER | 01/29/2026 | APPROVED | JSTEWART |
| Note: 1/28/2026 - PREVIOUS INSPECTION NOTES Front window X2, and right side window missing screws in top Fin, and needs flashing installed. | |||
| LATH/BRICK/ WATER BARRIER | 01/28/2026 | Disapproved - NO FEE | JSTEWART |
| Note: Front window X2, and right side window missing screws in top Fin, and needs flashing installed. | |||
| ALL ROUGH | 01/28/2026 | APPROVED - AS NOTED | JSTEWART |
| Note: Previous Notes not rectified.....Will check at Insulation 5. Please secure switch holding box to stud for pantry Light. NEC 314.23(B) 7. Underground romex for Island needs to be ran thru conduit, and secured. Per plan 1/26/2026 - PREVIOUS INSPECTION NOTES 1. Hood exhaust duct is reversed, Seams need to lap in the flow of exhaust. M1601.4.2 2. No water preassure, (Preassure gauge is broken replace it). FBCR P2503.5 3. No 5ft head test. FBCR P2503.7 4. Romex needs to terminate into the holding boxes min 1/4". (Check all locations, to many to list) NEC 314.17(C) 5. Please secure switch holding box to stud for pantry Light. NEC 314.23(B) 6. Please secure (fasten) loose studs in master bedroom at TV location. X(2). 7. Underground romex for Island needs to be ran thru conduit, and secured. Per plan | |||
| ALL ROUGH | 01/26/2026 | Disapproved - NO FEE | JSTEWART |
| Note: 1. Hood exhaust duct is reversed, Seams need to lap in the flow of exhaust. M1601.4.2 2. No water preassure, (Preassure gauge is broken replace it). FBCR P2503.5 3. No 5ft head test. FBCR P2503.7 4. Romex needs to terminate into the holding boxes min 1/4". (Check all locations, to many to list) NEC 314.17(C) 5. Please secure switch holding box to stud for pantry Light. NEC 314.23(B) 6. Please secure (fasten) loose studs in master bedroom at TV location. X(2). 7. Underground romex for Island needs to be ran thru conduit, and secured. Per plan | |||
| ELECTRIC-TUG | 01/26/2026 | APPROVED - AS NOTED | JSTEWART |
| Note: Authorize release of email. | |||
| WALL SHEATHING | 01/22/2026 | APPROVED | JSTEWART |
| Note: 1/21/2026 - PREVIOUS INSPECTION NOTES Missing nails at seem on right side by hose bibb 3' section. | |||
| ROOF VALLEY & METAL | 01/22/2026 | APPROVED | JSTEWART |
| Note: 1/21/2026 - PREVIOUS INSPECTION NOTES | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 01/21/2026 | APPROVED - AS NOTED | JSTEWART |
| Note: 1. Please Nail bottom chord of truss to 2x brace on top of interior shear wall 4" OC per PG. SD3 detail (GG). 2. Please add stud to structural exterior front wall in corner of closet and entry wall, where stud was cut out to install DTT2Z. | |||
| ROOF VALLEY & METAL | 01/21/2026 | CANCELLED BY APPLICANT | JSTEWART |
| WALL SHEATHING | 01/21/2026 | Disapproved - NO FEE | JSTEWART |
| Note: Missing nails at seem on right side by hose bibb 3' section. | |||
| GRAVITY SEWER TEST | 01/20/2026 | APPROVED | JSTEWART |
| Note: Live virtual | |||
| SEWER TIE IN | 01/20/2026 | APPROVED | JSTEWART |
| Note: Live virtual | |||
| MONOLITHIC SLAB | 01/06/2026 | APPROVED | JSTEWART |
| PLUMBING 1ST ROUGH UNDERGROUND | 12/30/2025 | APPROVED | JSTEWART |
| FORMBOARD SURVEY (OFFICE USE ONLY) | 12/29/2025 | APPROVED | RRICKS |
| WATER METER INSTALLATION REQUEST | 12/18/2025 | APPROVED | ISANDERSON |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 12/29/2025 | 12/29/2025 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 12/29/2025 | 12/29/2025 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 11/25/2025 | 11/25/2025 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 11/25/2025 | 12/03/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 11/12/2025 | 11/17/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 11/12/2025 | 11/18/2025 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 11/12/2025 | 11/17/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 11/12/2025 | 11/13/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| GAS | COMPLETE | 11/12/2025 | 11/13/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 11/12/2025 | 11/18/2025 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 11/12/2025 | 11/13/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 11/12/2025 | 11/19/2025 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | HOLD | 11/12/2025 | 11/14/2025 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Floor plan A-1 missing | |||
| URB | COMPLETE | 11/12/2025 | 11/17/2025 |
| Note: Released By: JOHN BEAUDET - (386)986-2456 - JBEAUDET@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| WATER-METER | ¤874.47 | 12/08/2025 |
| WATER- TURN ON | ¤50.00 | 12/08/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 12/08/2025 |
| INSPECTION - RESIDENTIAL | ¤948.75 | 12/08/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤269.10 | 12/08/2025 |
| FC IMPACT FEE EMS | ¤62.00 | 12/08/2025 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 12/08/2025 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 12/08/2025 |
| FIRE RES IMPACT FEE 10-25 | ¤942.00 | 12/08/2025 |
| WATER METER W/OUT TAP | ¤965.03 | 12/08/2025 |
| PARKS IMPACT FEE 10-25 | ¤3,164.00 | 12/08/2025 |
| RECLAIM WATER PERMIT INSPECTIO | ¤40.00 | 12/08/2025 |
| RSI DRIVEWAY AFTER POUR | ¤16.25 | 12/08/2025 |
| RSE DRIVE PRE POUR INSPECTION | ¤32.50 | 12/08/2025 |
| RSI FIELD SURVEY INSPECTION | ¤48.75 | 12/08/2025 |
| RSI FORMBOARD REVIEW | ¤16.25 | 12/08/2025 |
| RSI PLAN REVIEW NEW | ¤48.75 | 12/08/2025 |
| RSI FNL SURVEY/GRADING CERT | ¤48.75 | 12/08/2025 |
| RSI ROW FINAL INSPECTION | ¤16.25 | 12/08/2025 |
| SCHOOL BOARD IMPACT FEE RES | ¤5,450.00 | 12/08/2025 |
| SURCHARGE FS 533.721 | ¤12.48 | 12/08/2025 |
| SURCHARGE - FS 468.631 | ¤18.72 | 12/08/2025 |
| TRANSP RES IMPACT FEE 10-25 | ¤6,435.39 | 12/08/2025 |
| WASTEWATER PERM INSPECTION | ¤80.00 | 12/08/2025 |
| WASTEWATER PERM REVIEW | ¤25.00 | 12/08/2025 |
| SEWER CAPITAL FACILITY | ¤3,628.86 | 12/08/2025 |
| WATER CAPITAL FACILITY FEE | ¤3,091.14 | 12/08/2025 |
| WATER PERMIT REVIEW | ¤25.00 | 12/08/2025 |
| SITE PLAN 30 | ¤30.00 | 12/08/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤26,855.44 |