I want to search for...

Permit #2025110624

Permit Details

Status: COED

Parcel Id: 07-11-31-7033-00400-0310
CONDITIONED SPACE: 1801 sqft
GARAGE: 406 sqft
OPENED PORCH (WITH ROOF) : 58 sqft
OPENED PORCH (WITH ROOF) : 16 sqft
Total Square Footage: 2281 sqft
Block: 00400
Subdivision: 7033 -
Job Phone: 407-476-8195
Location Address: 3 RENFRO LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 12/04/2025
NOC: RECORDED
Applicant name: CARLETTE RENE WITTE
Owner: INB BFS LAND LLC

Address

7380 WEST SAND LAKE ROAD

ORLANDO, FL 32819

Address

SUITE 600

ORLANDO, FL 32819

Lot: 0310
Contracted Stated Job Value: ¤17,500.00
Job Description: single family residence
Type: CN

Contractor

INNOVATIVE NATIONWIDE BUILDERS INC
Status Location Address State License Number Phone
ACTIVE

3670 MAGUIRE BLVD #220

,

CRC1330026 (Exp: 08/31/2026) 855-694-6634

Sub Contractors

JASON LEE JAMES
Status Location Address State License Number Phone
ACTIVE

217 N WESTMONTE DR SUITE 1007

ALTAMONTE SPRINGS, FL 32714

CAC1820196 (Exp: 08/31/2026) 407-404-4000
TERRY BRICE DICKERSON
Status Location Address State License Number Phone
ACTIVE

4300 ST JOHN'S PARKWAY

ALPHARETTA, GA 30009

CCC1326209 (Exp: 08/31/2026) 407-548-6733
JOSEPH C WRIGHT
Status Location Address Mailing Address State License Number Phone Fax
ACTIVE

15 HARGROVE LANE

PALM COAST, FL 32137

UNIT 3 D

PALM COAST, FL 32137

EC13003278 (Exp: 08/31/2026) 386-447-9644 386-447-9633
HEATH EDWARD SANFORD
Status Location Address State License Number Phone
ACTIVE

126 EAST END RD

SAN MATEO, FL 32187

CFC1429896 (Exp: 08/31/2026) 386-871-8823

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 05/20/2026 APPROVED CVANSTRAHLEN
Note: 5/18/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1-M1502.4.7 Exhaust duct required. Where space for a clothes dryer is provided, an exhaust duct system shall be installed. Where the clothes dryer is not installed at the time of occupancy the exhaust duct shall be capped or plugged in the space in which it originates and identified and marked “future use. #2-missing garage door trim in and out #3-please removed trash from garage area #4- removed porta potty FBC 3303.5. keep SWALE CLEAR ( front )
BLD - BUILDING FINAL 05/18/2026 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: Please fix items before next inspection #1-M1502.4.7 Exhaust duct required. Where space for a clothes dryer is provided, an exhaust duct system shall be installed. Where the clothes dryer is not installed at the time of occupancy the exhaust duct shall be capped or plugged in the space in which it originates and identified and marked “future use. #2-missing garage door trim in and out #3-please removed trash from garage area #4- removed porta potty FBC 3303.5. keep SWALE CLEAR ( front )
ROW - FINAL APRON (AFTER POUR) 05/12/2026 APPROVED FSLADISH
Note: 5/12/26 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S AND/OR HOMEOWNER’S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ROW - FINAL INSPECTION 05/12/2026 APPROVED FSLADISH
Note: 5/12/26 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S AND/OR HOMEOWNER’S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
U -UTILITY RESIDENTIAL FINAL 05/12/2026 FINAL APPROVED BWRIGHT
Note: Inspector Notes from Inspection 9035 NO CC / NO IRR
ROW- FINAL SURVEY/GRADING CERTIFICATION 05/04/2026 APPROVED FSLADISH
Note: 5/4/26 BASED ON THE ENGINEER SIGNED AND SEALED LGADC MEETING THE COPC MINIMUM REQUIREMENTS AT THE TIME OF THIS INSPECTION, I AM APPROVING THIS DOCUMENT. Effective 3/25/26, the ROW Field Survey requirement is no longer in effect for Final Lot Grading and Drainage Certification for new construction on subdivision and infill lots. All Final Lot Grading and Drainage Certificates for these projects will now be reviewed and approved only in the office. Field verification for the ROW-FIELD SURVEY will no longer be required as part of the standard approval process for these permit types.
U-CROSS CONNECTION 05/01/2026 APPROVED - AS NOTED TLOWE
Note: NO CC / NO IRR
GRAVITY SEWER TEST 04/20/2026 APPROVED CVANSTRAHLEN
SEWER TIE IN 04/20/2026 APPROVED CVANSTRAHLEN
ROW- PRE-APRON (PRE-POUR) 04/16/2026 APPROVED FSLADISH
Note: 4/16/26 PIPE INVERT IS GOOD AT TIME OF THIS INSPECTION. BUILDER REFER TO CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED. DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR BEFORE POURING. . IF FIBERGLASS OPTION IS USED, BUILDER REQUIRED TO USE 3000 PSI CONCRETE AT THE TIME OF THE INSPECTION READY TO POUR, IF RAIN, BUILDER SHOULD DOUBLE CHECK SITE FOR ANY STANDING WATER AND VERIFY PIPE ELEVATION HAS NOT CHANGED. NO EXPANSION JOINTS ALLOWED, AT THE TIME OF THIS INSPECTION ALL MINIMUM COPC REQUIREMENTS ARE MET. BUILDER TO BE HELD RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR.
ELECTRIC - EARLY POWER 04/15/2026 APPROVED KSANDOE
DRYWALL NAILING 03/24/2026 APPROVED CVANSTRAHLEN
INSULATION 03/17/2026 APPROVED PKNAPIK
Note: Inspector Notes from Inspection 2320 Inspector Notes from Inspection 2420 Please fix items before next inspection #1-FBCR P2605.1-PIPE SUPPORT PEX 32" HORIZONTAL 10 FOOT VERTICAL CPVC UP TO 1" - 3 FEET HORIZONTAL, 10 FEET VERTICAL CPVC 1 1/4" AND UP - 4 FEET HORIZONTAL, 10 FEET VERTICAL PVC 4 FOOT HORIZONTAL, 10 FEET VERTICAL (AIR vent pipes )
PEP TANK INSTALLATION REQUEST 03/17/2026 APPROVED ISANDERSON
Note: Siding not complete. Dumpster in the way.
LATH/BRICK/ WATER BARRIER 03/16/2026 APPROVED - AS NOTED KSANDOE
Note: Inspector Notes from Inspection 2420 Please fix items before next inspection #1-FBCR P2605.1-PIPE SUPPORT PEX 32" HORIZONTAL 10 FOOT VERTICAL CPVC UP TO 1" - 3 FEET HORIZONTAL, 10 FEET VERTICAL CPVC 1 1/4" AND UP - 4 FEET HORIZONTAL, 10 FEET VERTICAL PVC 4 FOOT HORIZONTAL, 10 FEET VERTICAL (AIR vent pipes )
ALL ROUGH 03/12/2026 APPROVED - AS NOTED CVANSTRAHLEN
Note: Please fix items before next inspection #1-FBCR P2605.1-PIPE SUPPORT PEX 32" HORIZONTAL 10 FOOT VERTICAL CPVC UP TO 1" - 3 FEET HORIZONTAL, 10 FEET VERTICAL CPVC 1 1/4" AND UP - 4 FEET HORIZONTAL, 10 FEET VERTICAL PVC 4 FOOT HORIZONTAL, 10 FEET VERTICAL (AIR vent pipes )
ELECTRIC-TUG 03/11/2026 APPROVED CVANSTRAHLEN
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/09/2026 APPROVED CVANSTRAHLEN
ROOF VALLEY & METAL 03/05/2026 APPROVED CVANSTRAHLEN
ROOF SHEATHING 03/03/2026 APPROVED CVANSTRAHLEN
Note: 2/27/2026 - PREVIOUS INSPECTION NOTES 2-27-26 1. Not ready.
ROOF SHEATHING 02/27/2026 Disapproved - NO FEE BTAYLOR
Note: 2-27-26 1. Not ready.
WALL SHEATHING 02/27/2026 APPROVED BTAYLOR
TIE BEAM / LINTEL 02/18/2026 APPROVED CVANSTRAHLEN
MONOLITHIC SLAB 02/10/2026 APPROVED CVANSTRAHLEN
Note: 2/9/2026 - PREVIOUS INSPECTION NOTES FBCR 506.2.1-TERMITE TREATMENT OR NOTICE OF INTENT FOR BORACARE
MONOLITHIC SLAB 02/09/2026 Disapproved - NO FEE CVANSTRAHLEN
Note: *** NOTES ADDED BY CVANSTRAHLEN 2/9/2026 9:42:36 AM *** FBC 3302.2-NEEDS DUMPSTER FBC 3307.1-NEEDS SILT FENCE PROPERLY INSTALLED FBCR 506.2.1-TERMITE TREATMENT OR NOTICE OF INTENT FOR BORACARE
PLUMBING 1ST ROUGH UNDERGROUND 02/05/2026 APPROVED CVANSTRAHLEN
FORMBOARD SURVEY (OFFICE USE ONLY) 02/04/2026 APPROVED RRICKS
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 02/04/2026 APPROVED PKNAPIK
WATER METER INSTALLATION REQUEST 01/15/2026 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
BLD COMPLETE 02/04/2026 02/04/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
SW1 COMPLETE 02/04/2026 02/04/2026
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 02/04/2026 02/04/2026
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ZON COMPLETE 11/26/2025 11/26/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
SWALE COMPLETE 11/19/2025 12/04/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
BLD COMPLETE 11/18/2025 11/24/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
CUSVC COMPLETE 11/18/2025 11/21/2025
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 11/18/2025 11/19/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 11/18/2025 11/19/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS CANCEL 11/18/2025 11/20/2025
LOCATE COMPLETE 11/18/2025 11/21/2025
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 11/18/2025 11/20/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 11/18/2025 11/24/2025
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON HOLD 11/18/2025 11/21/2025
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Elevation plan Windows and doors facing the Right of way need banding all aroundadjust plans accordingly.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 05/19/2026
FC IMPACT FEE EMS ¤62.00 12/04/2025
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 12/04/2025
FC IMPACT FEE LIBRARY ¤268.00 12/04/2025
FIRE RES IMPACT FEE 10-25 ¤942.00 12/04/2025
PEP TANK INSTALL ¤756.74 12/04/2025
PARKS IMPACT FEE 10-25 ¤3,164.00 12/04/2025
RSI DRIVEWAY AFTER POUR ¤16.25 12/04/2025
RSE DRIVE PRE POUR INSPECTION ¤32.50 12/04/2025
RSI FIELD SURVEY INSPECTION ¤48.75 12/04/2025
RSI FORMBOARD REVIEW ¤16.25 12/04/2025
RSI PLAN REVIEW NEW ¤48.75 12/04/2025
RSI FNL SURVEY/GRADING CERT ¤48.75 12/04/2025
RSI ROW FINAL INSPECTION ¤16.25 12/04/2025
SCHOOL BOARD IMPACT FEE RES ¤5,450.00 12/04/2025
WASTEWATER MAIN EXTENSION IMPA ¤2,385.00 12/04/2025
SURCHARGE FS 533.721 ¤12.37 12/04/2025
SURCHARGE - FS 468.631 ¤18.56 12/04/2025
SW ENG RES REVIEW 240 ¤240.00 12/04/2025
WATER METER W/ TAP ¤2,326.93 12/04/2025
TRANSP RES IMPACT FEE 10-25 ¤6,789.77 12/04/2025
SEWER CREDIT (¤1,812.53) 12/04/2025
WASTEWATER PERM INSPECTION ¤80.00 12/04/2025
WASTEWATER PERM REVIEW ¤25.00 12/04/2025
SEWER CAPITAL FACILITY ¤4,415.00 12/04/2025
WATER CREDIT (¤299.27) 12/04/2025
WATER CAPITAL FACILITY FEE ¤3,790.49 12/04/2025
WATER PERMIT REVIEW ¤25.00 12/04/2025
WATER MAIN EXTENSION IMPACT ¤917.27 12/04/2025
SITE PLAN 30 ¤30.00 12/04/2025
WATER- TURN ON ¤50.00 12/04/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 12/04/2025
INSPECTION - RESIDENTIAL ¤940.50 12/04/2025
PLAN REVIEW - RESIDENTIAL ¤266.76 12/04/2025
Fees Total Due: ¤0.00 Total Paid: ¤31,359.09