I want to search for...
Permit #2025110863
Permit Details
Status: COED
| Parcel Id: 07-11-31-7026-00150-0180 |
| Block: 00150 |
| Subdivision: 7026 - |
| Job Phone: 407-814-3572 |
| Location Address: 22 PINETREE DR |
| Type: RF - REROOF |
| Issue Date: 11/25/2025 |
| NOC: RECORDED |
| Applicant name: JAMIE MARIE BOCCARD |
| Owner: SERRANO KIM |
|
Address 22 PINETREE DRIVE PALM COAST, FL 32164 |
| Lot: 0180 |
| Contracted Stated Job Value: ¤15,100.00 |
| Job Description: Re-Roof - |
| Type: CN |
Contractor
BEST PRICE ROOFING INC
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
1232 ROCK SPRINGS ROAD APOPKA, FL 32704 |
SUITE 12 APOPKA, FL 32704 |
CCC1331261 (Exp: 08/31/2026) | 407-814-3572 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROOF FINAL | 12/11/2025 | FINAL APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 12/10/2025 3:12:31 PM *** 12/8/2025 - PREVIOUS INSPECTION NOTES 12/8/25: 1). Dryer exhaust has the screen removed but does not have a self closing damper as required. FBC M1502.3 The gooseneck will need to be replaced with a self closing damper equipped type. Please refer to the FBC cited for full code requirements. (shown below). M1502.3 Duct termination. Exhaust ducts shall terminate on the outside of the building. Exhaust duct terminations shall be in accordance with the dryer manufacturer's installation instructions. If the manufacturer's instructions do not specify a termination location, the exhaust duct shall terminate not less than 3 feet (914mm) in any direction from openings into buildings. Exhaust duct terminations shall be equipped with a backdraft damper. Screens shall not be installed at the duct termination. 12/5/2025 - PREVIOUS INSPECTION NOTES 12/5/25: 1). dryer gooseneck needs screen removed as required. FBC M1502.3 2). Drip edge needs to be sealed where it meets or enters stucco in both areas at front entry. FBC-R903.2 | |||
| ROOF FINAL | 12/08/2025 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 12/8/2025 11:13:14 AM *** 12/8/25: 1). Dryer exhaust has the screen removed but does not have a self closing damper as required. FBC M1502.3 The gooseneck will need to be replaced with a self closing damper equipped type. Please refer to the FBC cited for full code requirements. (shown below). M1502.3 Duct termination. Exhaust ducts shall terminate on the outside of the building. Exhaust duct terminations shall be in accordance with the dryer manufacturer's installation instructions. If the manufacturer's instructions do not specify a termination location, the exhaust duct shall terminate not less than 3 feet (914mm) in any direction from openings into buildings. Exhaust duct terminations shall be equipped with a backdraft damper. Screens shall not be installed at the duct termination. 12/5/2025 - PREVIOUS INSPECTION NOTES 12/5/25: 1). dryer gooseneck needs screen removed as required. FBC M1502.3 2). Drip edge needs to be sealed where it meets or enters stucco in both areas at front entry. FBC-R903.2 | |||
| ROOF FINAL | 12/05/2025 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 12/5/2025 10:55:02 AM *** 12/5/25: 1). dryer gooseneck needs screen removed as required. FBC M1502.3 2). Drip edge needs to vbe sealed where it meets or enters stucco in both areas at front entry. FBC-R903.2 | |||
| ROOF IN PROGRESS- MIDROOF | 12/03/2025 | APPROVED | MCONTRYMAN |
| ROOF AFFIDAVIT | 12/03/2025 | APPROVED | MRAMOS |
| ROOF IN PROGRESS- MIDROOF | 12/02/2025 | CANCELLED BY APPLICANT | WEB |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/08/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/05/2025 |
| SURCHARGE FS 533.721 | ¤2.00 | 11/25/2025 |
| SURCHARGE - FS 468.631 | ¤2.00 | 11/25/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 11/25/2025 |
| INSPECTION - RESIDENTIAL | ¤60.00 | 11/25/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤174.00 |