I want to search for...

Permit #2025120293

Permit Details

Status: INSPECT

Parcel Id: 07-11-31-7025-00090-0260
CONDITIONED SPACE: 2067 sqft
GARAGE: 597 sqft
OPENED PORCH (WITH ROOF) : 120 sqft
OPENED PORCH (WITH ROOF) : 37 sqft
Total Square Footage: 2821 sqft
Block: 00090
Subdivision: 2189 - SECTION 25-PINE GROVE
Job Phone: 407-476-8195
Location Address: 25 PEBBLE STONE LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 12/26/2025
NOC: RECORDED
Applicant name: CARLETTE RENE WITTE
Owner: INB BFS LAND LLC

Address

7380 WEST SAND LAKE ROAD

ORLANDO, FL 32819

Address

SUITE 600

ORLANDO, FL 32819

Lot: 0260
Contracted Stated Job Value: ¤250,000.00
Job Description: Construction of New SFR
Type: CN

Contractor

INNOVATIVE NATIONWIDE BUILDERS INC
Status Location Address State License Number Phone
ACTIVE

3670 MAGUIRE BLVD #220

,

CRC1330026 (Exp: 08/31/2026) 855-694-6634

Sub Contractors

JASON LEE JAMES
Status Location Address State License Number Phone
ACTIVE

217 N WESTMONTE DR SUITE 1007

ALTAMONTE SPRINGS, FL 32714

CAC1820196 (Exp: 08/31/2026) 407-404-4000
ANTHONY OKEITH FENNELL
Status Location Address State License Number Phone
ACTIVE

217 N. WESTMONTE DR, SUITE 1007

ALTAMONTE SPRINGS, FL 32714

EC13011194 (Exp: 08/31/2026) 407-404-4000
HEATH EDWARD SANFORD
Status Location Address State License Number Phone
ACTIVE

126 EAST END RD

SAN MATEO, FL 32187

CFC1429896 (Exp: 08/31/2026) 386-871-8823
TERRY BRICE DICKERSON
Status Location Address State License Number Phone
ACTIVE

4300 ST JOHN'S PARKWAY

ALPHARETTA, GA 30009

CCC1326209 (Exp: 08/31/2026) 407-548-6733

Inspection History

Type Request Date Result Inspector
ROW - DRAINAGE 06/15/2026 TPOLACEK
Note: 6/9/2026 - PREVIOUS INSPECTION NOTES 6/9/26 YOUR DOUBLE SILTFENCE ON THE RIGHT SIDE HAS FAILED IN SEVERAL ARES AND THERE ARE WASHOUTS AND DIRT/SILT GETTING INTO THE COPC DITCH. YOU ARE REQUIRED TO RESET THE SILT FENCEING ON THE DITCH SLOPE DOUBLE FENCE 5' APART TO CONTAIN ANY FUTURE SEDIMENT. IT IS RAINING SEASON AND IMPERATIVE THAT WE KEEP SEDIMENT OUT OF COPC DRAINAGE CONVEYANCES. YOU ARE ALSO REQUIRED TO INSTALL INLET DRAINAGE PROTECTION ON THE COPC CATCH BASIN TO CATCH ANT SEDIMENT WASHING FROM YOUR SITE THAT MAY WASH INTO COPC STORMWATER CONVEYANCES. PLEASE REST/REPAIR SILT FENCING AROUND SITE. WE WILL BE BACK FOR A COMPLIANCE REINSPECTION 6/15/26. PHOTOS FOR REFERENCE.
ROW - DRAINAGE 06/09/2026 Disapproved -FEE REQUIRED FSLADISH
Note: 6/9/26 YOUR DOUBLE SILTFENCE ON THE RIGHT SIDE HAS FAILED IN SEVERAL ARES AND THERE ARE WASHOUTS AND DIRT/SILT GETTING INTO THE COPC DITCH. YOU ARE REQUIRED TO RESET THE SILT FENCEING ON THE DITCH SLOPE DOUBLE FENCE 5' APART TO CONTAIN ANY FUTURE SEDIMENT. IT IS RAINING SEASON AND IMPERATIVE THAT WE KEEP SEDIMENT OUT OF COPC DRAINAGE CONVEYANCES. YOU ARE ALSO REQUIRED TO INSTALL INLET DRAINAGE PROTECTION ON THE COPC CATCH BASIN TO CATCH ANT SEDIMENT WASHING FROM YOUR SITE THAT MAY WASH INTO COPC STORMWATER CONVEYANCES. PLEASE REST/REPAIR SILT FENCING AROUND SITE. WE WILL BE BACK FOR A COMPLIANCE REINSPECTION 6/15/26. PHOTOS FOR REFERENCE.
ROW- PRE-APRON (PRE-POUR) 06/09/2026 APPROVED FSLADISH
Note: 6/9/26 PIPE INVERT IS GOOD AT TIME OF THIS INSPECTION. BUILDER REFER TO CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED. DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR BEFORE POURING. . IF FIBERGLASS OPTION IS USED, BUILDER REQUIRED TO USE 3000 PSI CONCRETE AT THE TIME OF THE INSPECTION READY TO POUR, IF RAIN, BUILDER SHOULD DOUBLE CHECK SITE FOR ANY STANDING WATER AND VERIFY PIPE ELEVATION HAS NOT CHANGED. NO EXPANSION JOINTS ALLOWED, AT THE TIME OF THIS INSPECTION ALL MINIMUM COPC REQUIREMENTS ARE MET. BUILDER TO BE HELD RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR.
ELECTRIC - EARLY POWER 06/05/2026 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 6/5/2026 1:02:04 PM *** 6/5/26: FPL emailed to release power.
ELECTRIC - EARLY POWER 06/03/2026 CANCELLED BY APPLICANT WEB
DRYWALL NAILING 04/28/2026 APPROVED HCAMACHO
INSULATION 04/23/2026 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 4/23/2026 3:17:55 PM *** Approved 4/21/2026 - PREVIOUS INSPECTION NOTES 4/21/26: Previously listed item 2 remains unresolved. See code listed for approved material application. 2). Fireblocking at the top of the bathtub pack out wall needs to be 1-1/2" thick per FBC-R302.11.1 4/17/2026 - PREVIOUS INSPECTION NOTES 4/17/26: 1). Missing firestop at gap in top plate to the left of laundry box. FS marked on the back side of the wall. FBC-R302.11 2). Fireblocking at the top of the bathtub pack out wall needs to be 1-1/2" thick per FBC-R302.11.1 3). Front entry door is missing foam insulation along perimeter and is missing solid blocking where shim space exceeds 1/4". FBC EC TABLE R402.4.1.1 / FBCR 609.1 4). Miscellaneous Cardboard baffles do not meet the minimum 1" air space from roof sheathing as required. FBC-R806.3. Please check all. Inspector Notes from Inspection 2320 *** NOTES ADDED BY RSIMS 4/15/2026 11:21:24 AM *** 4/15/26: Still need to check ducts at Insulation inspection. Inspector Notes from Inspection 2420 1. Missing Energy calcs. Need to recheck A/C Ducts at insulation.
INSULATION 04/21/2026 Disapproved -FEE REQUIRED RSIMS
Note: 4/21/26: Previously listed item 2 remains unresolved. See code listed for approved material application. 2). Fireblocking at the top of the bathtub pack out wall needs to be 1-1/2" thick per FBC-R302.11.1 4/17/2026 - PREVIOUS INSPECTION NOTES 4/17/26: 1). Missing firestop at gap in top plate to the left of laundry box. FS marked on the back side of the wall. FBC-R302.11 2). Fireblocking at the top of the bathtub pack out wall needs to be 1-1/2" thick per FBC-R302.11.1 3). Front entry door is missing foam insulation along perimeter and is missing solid blocking where shim space exceeds 1/4". FBC EC TABLE R402.4.1.1 / FBCR 609.1 4). Miscellaneous Cardboard baffles do not meet the minimum 1" air space from roof sheathing as required. FBC-R806.3. Please check all. Inspector Notes from Inspection 2320 *** NOTES ADDED BY RSIMS 4/15/2026 11:21:24 AM *** 4/15/26: Still need to check ducts at Insulation inspection. Inspector Notes from Inspection 2420 1. Missing Energy calcs. Need to recheck A/C Ducts at insulation.
INSULATION 04/17/2026 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 4/17/2026 10:13:17 AM *** 4/17/26: 1). Missing firestop at gap in top plate to the left of laundry box. FS marked on the back side of the wall. FBC-R302.11 2). Fireblocking at the top of the bathtub pack out wall needs to be 1-1/2" thick per FBC-R302.11.1 3). Front entry door is missing foam insulation along perimeter and is missing so9lid blocking where shim space exceeds 1/4". FBC EC TABLE R402.4.1.1 / FBCR 609.1 4). Miscellaneous Cardboard baffles do not meet the minimum 1" air space from roof sheathing as required. FBC-R806.3. Please check all. Inspector Notes from Inspection 2320 *** NOTES ADDED BY RSIMS 4/15/2026 11:21:24 AM *** 4/15/26: Still need to check ducts at Insulation inspection. Inspector Notes from Inspection 2420 1. Missing Energy calcs. Need to recheck A/C Ducts at insulation.
LATH/BRICK/ WATER BARRIER 04/15/2026 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 4/15/2026 11:21:24 AM *** 4/15/26: Still need to check ducts at Insulation inspection. Inspector Notes from Inspection 2420 1. Missing Energy calcs. Need to recheck A/C Ducts at insulation.
ELECTRIC-TUG 04/14/2026 APPROVED HCAMACHO
Note: 4/10/2026 - PREVIOUS INSPECTION NOTES 4/10/26: 1). TUG outlet box needs to be secured to the wall. NEC-334.30 / NEC 350.30(A)
ALL ROUGH 04/14/2026 APPROVED - AS NOTED HCAMACHO
Note: 1. Missing Energy calcs. Need to recheck A/C Ducts at insulation.
ELECTRIC-TUG 04/10/2026 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 4/10/2026 2:34:30 PM *** 4/10/26: 1). TUG outlet box needs to be secured to the wall. NEC-334.30 / NEC 350.30(A)
WALL SHEATHING 04/01/2026 APPROVED HCAMACHO
ROOF SHEATHING / BRACES/TIES/DOWN CELL 04/01/2026 APPROVED - AS NOTED HCAMACHO
Note: 1. T03 missing eng. See plans.
ROOF VALLEY & METAL 04/01/2026 APPROVED HCAMACHO
ROOF SHEATHING 03/30/2026 APPROVED HCAMACHO
Note: 3/27/2026 - PREVIOUS INSPECTION NOTES 3/27/26: NOT READY! 1). Contractors still working on installing Roof Sheathing. FBC [A]107.4 Inspector Notes from Inspection 2340 *** NOTES ADDED BY RSIMS 3/6/2026 10:22:45 AM *** 3/6/26: Deficiencies need to be repaired by next inspection. 1). Window Sill mortar beds and/or Concrete Block joints exceed the maximum thickness (sills - 1/2" / CMU joints - 3/8") per FBC-R606.3.1 > Spray painted orange.
ROOF SHEATHING 03/27/2026 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 3/27/2026 9:46:58 AM *** 3/27/26: NOT READY! 1). Contractors still working on installing Roof Sheathing. FBC [A]107.4 Inspector Notes from Inspection 2340 *** NOTES ADDED BY RSIMS 3/6/2026 10:22:45 AM *** 3/6/26: Deficiencies need to be repaired by next inspection. 1). Window Sill mortar beds and/or Concrete Block joints exceed the maximum thickness (sills - 1/2" / CMU joints - 3/8") per FBC-R606.3.1 > Spray painted orange.
TIE BEAM / LINTEL 03/06/2026 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 3/6/2026 10:22:45 AM *** 3/6/26: Deficiencies need to be repaired by next inspection. 1). Window Sill mortar beds and/or Concrete Block joints exceed the maximum thickness (sills - 1/2" / CMU joints - 3/8") per FBC-R606.3.1 > Spray painted orange.
MONOLITHIC SLAB 02/27/2026 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 2/27/2026 10:18:33 AM *** 2/26/2026 - PREVIOUS INSPECTION NOTES 2/26/26: 1). No termite certification or intent to treat displayed in the permit box or on site. FBCR 318
MONOLITHIC SLAB 02/26/2026 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 2/26/2026 1:30:11 PM *** 2/26/26: 1). No termite certification or intent to treat displayed in the permit box or on site. FBCR 318
PLUMBING 1ST ROUGH UNDERGROUND 02/24/2026 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 2/24/2026 3:12:44 PM *** 2/20/2026 - PREVIOUS INSPECTION NOTES 2/20/26: 1). Pressure test is not holding. Gauge reading @ 15psi upon arrival. Per PEX manufacturing guidelines requires 25PSI above working pressure or 100PSI minimum. FBCR P2503.7 2). Hot and Cold water are strapped together and manufacturer requires 6" minimum separation. FBC [A]107.4
GRAVITY SEWER TEST 02/20/2026 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 2/20/2026 9:02:09 AM ***
SEWER TIE IN 02/20/2026 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 2/20/2026 9:02:27 AM ***
PLUMBING 1ST ROUGH UNDERGROUND 02/20/2026 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 2/20/2026 9:15:00 AM *** 2/20/26: 1). Pressure test is not holding. Gauge reading @ 15psi upon arrival. Per PEX manufacturing guidelines requires 25PSI above working pressure or 100PSI minimum. FBCR P2503.7 2). Hot and Cold water are strapped together and manufacturer requires 6" minimum separation. FBC [A]107.4
FORMBOARD SURVEY (OFFICE USE ONLY) 02/19/2026 APPROVED PFLANAGAN
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 02/19/2026 APPROVED PKNAPIK
WATER METER INSTALLATION REQUEST 02/06/2026 APPROVED CBOWERMASTER
U-CROSS CONNECTION
ROW - FINAL APRON (AFTER POUR)
ROW - FINAL INSPECTION
U -UTILITY RESIDENTIAL FINAL
BLD - BUILDING FINAL

Review History

Department Status Date In Date Out
ZON COMPLETE 02/19/2026 02/19/2026
Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM
BLD COMPLETE 02/18/2026 02/19/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
SW1 COMPLETE 02/18/2026 02/19/2026
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON HOLD 02/18/2026 02/18/2026
Note: Held By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM Formboard survey has open form. Need to to be open form.
ENGIN1 COMPLETE 01/20/2026 01/27/2026
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
SW1 COMPLETE 01/20/2026 01/20/2026
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 01/20/2026 01/20/2026
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
MECH COMPLETE 12/16/2025 12/18/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SWALE COMPLETE 12/09/2025 12/30/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
BLD COMPLETE 12/08/2025 12/15/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
CUSVC COMPLETE 12/08/2025 12/16/2025
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 12/08/2025 12/11/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 12/08/2025 12/09/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS CANCEL 12/08/2025 12/09/2025
LOCATE COMPLETE 12/08/2025 12/12/2025
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH HOLD 12/08/2025 12/10/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM State Card needs to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2023 8Th edition
SW1 COMPLETE 12/08/2025 12/15/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Note: There is a ditch in between lot 26 and 25 with a 20' easement. No issues with proposed FFE.
ZON COMPLETE 12/08/2025 12/09/2025
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
RSI REINSPECTION 1 ¤35.00 06/10/2026
RSI REINSPECTION 1 ¤35.00 06/10/2026
REINSPECTION RESIDENTIAL ¤40.00 06/05/2026
REINSPECTION RESIDENTIAL ¤40.00 06/05/2026
REINSPECTION RESIDENTIAL ¤40.00 06/05/2026
FC IMPACT FEE EMS ¤62.00 12/26/2025
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 12/26/2025
FC IMPACT FEE LIBRARY ¤268.00 12/26/2025
FIRE RES IMPACT FEE 10-25 ¤942.00 12/26/2025
PARKS IMPACT FEE 10-25 ¤3,164.00 12/26/2025
RSI DRIVEWAY AFTER POUR ¤16.25 12/26/2025
RSE DRIVE PRE POUR INSPECTION ¤32.50 12/26/2025
RSI FIELD SURVEY INSPECTION ¤48.75 12/26/2025
RSI FORMBOARD REVIEW ¤16.25 12/26/2025
RSI PLAN REVIEW NEW ¤48.75 12/26/2025
RSI FNL SURVEY/GRADING CERT ¤48.75 12/26/2025
WATER- TURN ON ¤50.00 12/26/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 12/26/2025
INSPECTION - RESIDENTIAL ¤1,116.50 12/26/2025
PLAN REVIEW - RESIDENTIAL ¤316.68 12/26/2025
RSI ROW FINAL INSPECTION ¤16.25 12/26/2025
SCHOOL BOARD IMPACT FEE RES ¤5,450.00 12/26/2025
WASTEWATER MAIN EXTENSION IMPA ¤2,385.00 12/26/2025
SURCHARGE FS 533.721 ¤14.63 12/26/2025
SURCHARGE - FS 468.631 ¤21.95 12/26/2025
SW ENG RES REVIEW 240 ¤240.00 12/26/2025
WATER METER W/ TAP ¤2,326.93 12/26/2025
TRANSP RES IMPACT FEE 10-25 ¤7,792.59 12/26/2025
SEWER CREDIT (¤958.00) 12/26/2025
WASTEWATER PERM INSPECTION ¤80.00 12/26/2025
WASTEWATER PERM REVIEW ¤25.00 12/26/2025
SEWER CAPITAL FACILITY ¤4,415.00 12/26/2025
WATER CAPITAL FACILITY FEE ¤3,790.49 12/26/2025
WATER PERMIT REVIEW ¤25.00 12/26/2025
WATER MAIN EXTENSION IMPACT ¤917.27 12/26/2025
SITE PLAN 30 ¤30.00 12/26/2025
Fees Total Due: ¤0.00 Total Paid: ¤33,140.54