I want to search for...
Permit #2025120293
Permit Details
Status: INSPECT
| Parcel Id: 07-11-31-7025-00090-0260 |
| CONDITIONED SPACE: 2067 sqft |
| GARAGE: 597 sqft |
| OPENED PORCH (WITH ROOF) : 120 sqft |
| OPENED PORCH (WITH ROOF) : 37 sqft |
| Total Square Footage: 2821 sqft |
| Block: 00090 |
| Subdivision: 2189 - SECTION 25-PINE GROVE |
| Job Phone: 407-476-8195 |
| Location Address: 25 PEBBLE STONE LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 12/26/2025 |
| NOC: RECORDED |
| Applicant name: CARLETTE RENE WITTE |
| Owner: INB BFS LAND LLC |
|
Address 7380 WEST SAND LAKE ROAD ORLANDO, FL 32819 |
|
Address SUITE 600 ORLANDO, FL 32819 |
| Lot: 0260 |
| Contracted Stated Job Value: ¤250,000.00 |
| Job Description: Construction of New SFR |
| Type: CN |
Contractor
INNOVATIVE NATIONWIDE BUILDERS INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3670 MAGUIRE BLVD #220 , |
CRC1330026 (Exp: 08/31/2026) | 855-694-6634 |
Sub Contractors
JASON LEE JAMES
| Status | Location Address | State License Number | Phone |
| ACTIVE |
217 N WESTMONTE DR SUITE 1007 ALTAMONTE SPRINGS, FL 32714 |
CAC1820196 (Exp: 08/31/2026) | 407-404-4000 |
ANTHONY OKEITH FENNELL
| Status | Location Address | State License Number | Phone |
| ACTIVE |
217 N. WESTMONTE DR, SUITE 1007 ALTAMONTE SPRINGS, FL 32714 |
EC13011194 (Exp: 08/31/2026) | 407-404-4000 |
HEATH EDWARD SANFORD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
126 EAST END RD SAN MATEO, FL 32187 |
CFC1429896 (Exp: 08/31/2026) | 386-871-8823 |
TERRY BRICE DICKERSON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4300 ST JOHN'S PARKWAY ALPHARETTA, GA 30009 |
CCC1326209 (Exp: 08/31/2026) | 407-548-6733 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROW - DRAINAGE | 06/15/2026 | TPOLACEK | |
| Note: 6/9/2026 - PREVIOUS INSPECTION NOTES 6/9/26 YOUR DOUBLE SILTFENCE ON THE RIGHT SIDE HAS FAILED IN SEVERAL ARES AND THERE ARE WASHOUTS AND DIRT/SILT GETTING INTO THE COPC DITCH. YOU ARE REQUIRED TO RESET THE SILT FENCEING ON THE DITCH SLOPE DOUBLE FENCE 5' APART TO CONTAIN ANY FUTURE SEDIMENT. IT IS RAINING SEASON AND IMPERATIVE THAT WE KEEP SEDIMENT OUT OF COPC DRAINAGE CONVEYANCES. YOU ARE ALSO REQUIRED TO INSTALL INLET DRAINAGE PROTECTION ON THE COPC CATCH BASIN TO CATCH ANT SEDIMENT WASHING FROM YOUR SITE THAT MAY WASH INTO COPC STORMWATER CONVEYANCES. PLEASE REST/REPAIR SILT FENCING AROUND SITE. WE WILL BE BACK FOR A COMPLIANCE REINSPECTION 6/15/26. PHOTOS FOR REFERENCE. | |||
| ROW - DRAINAGE | 06/09/2026 | Disapproved -FEE REQUIRED | FSLADISH |
| Note: 6/9/26 YOUR DOUBLE SILTFENCE ON THE RIGHT SIDE HAS FAILED IN SEVERAL ARES AND THERE ARE WASHOUTS AND DIRT/SILT GETTING INTO THE COPC DITCH. YOU ARE REQUIRED TO RESET THE SILT FENCEING ON THE DITCH SLOPE DOUBLE FENCE 5' APART TO CONTAIN ANY FUTURE SEDIMENT. IT IS RAINING SEASON AND IMPERATIVE THAT WE KEEP SEDIMENT OUT OF COPC DRAINAGE CONVEYANCES. YOU ARE ALSO REQUIRED TO INSTALL INLET DRAINAGE PROTECTION ON THE COPC CATCH BASIN TO CATCH ANT SEDIMENT WASHING FROM YOUR SITE THAT MAY WASH INTO COPC STORMWATER CONVEYANCES. PLEASE REST/REPAIR SILT FENCING AROUND SITE. WE WILL BE BACK FOR A COMPLIANCE REINSPECTION 6/15/26. PHOTOS FOR REFERENCE. | |||
| ROW- PRE-APRON (PRE-POUR) | 06/09/2026 | APPROVED | FSLADISH |
| Note: 6/9/26 PIPE INVERT IS GOOD AT TIME OF THIS INSPECTION. BUILDER REFER TO CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED. DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR BEFORE POURING. . IF FIBERGLASS OPTION IS USED, BUILDER REQUIRED TO USE 3000 PSI CONCRETE AT THE TIME OF THE INSPECTION READY TO POUR, IF RAIN, BUILDER SHOULD DOUBLE CHECK SITE FOR ANY STANDING WATER AND VERIFY PIPE ELEVATION HAS NOT CHANGED. NO EXPANSION JOINTS ALLOWED, AT THE TIME OF THIS INSPECTION ALL MINIMUM COPC REQUIREMENTS ARE MET. BUILDER TO BE HELD RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR. | |||
| ELECTRIC - EARLY POWER | 06/05/2026 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 6/5/2026 1:02:04 PM *** 6/5/26: FPL emailed to release power. | |||
| ELECTRIC - EARLY POWER | 06/03/2026 | CANCELLED BY APPLICANT | WEB |
| DRYWALL NAILING | 04/28/2026 | APPROVED | HCAMACHO |
| INSULATION | 04/23/2026 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 4/23/2026 3:17:55 PM *** Approved 4/21/2026 - PREVIOUS INSPECTION NOTES 4/21/26: Previously listed item 2 remains unresolved. See code listed for approved material application. 2). Fireblocking at the top of the bathtub pack out wall needs to be 1-1/2" thick per FBC-R302.11.1 4/17/2026 - PREVIOUS INSPECTION NOTES 4/17/26: 1). Missing firestop at gap in top plate to the left of laundry box. FS marked on the back side of the wall. FBC-R302.11 2). Fireblocking at the top of the bathtub pack out wall needs to be 1-1/2" thick per FBC-R302.11.1 3). Front entry door is missing foam insulation along perimeter and is missing solid blocking where shim space exceeds 1/4". FBC EC TABLE R402.4.1.1 / FBCR 609.1 4). Miscellaneous Cardboard baffles do not meet the minimum 1" air space from roof sheathing as required. FBC-R806.3. Please check all. Inspector Notes from Inspection 2320 *** NOTES ADDED BY RSIMS 4/15/2026 11:21:24 AM *** 4/15/26: Still need to check ducts at Insulation inspection. Inspector Notes from Inspection 2420 1. Missing Energy calcs. Need to recheck A/C Ducts at insulation. | |||
| INSULATION | 04/21/2026 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 4/21/26: Previously listed item 2 remains unresolved. See code listed for approved material application. 2). Fireblocking at the top of the bathtub pack out wall needs to be 1-1/2" thick per FBC-R302.11.1 4/17/2026 - PREVIOUS INSPECTION NOTES 4/17/26: 1). Missing firestop at gap in top plate to the left of laundry box. FS marked on the back side of the wall. FBC-R302.11 2). Fireblocking at the top of the bathtub pack out wall needs to be 1-1/2" thick per FBC-R302.11.1 3). Front entry door is missing foam insulation along perimeter and is missing solid blocking where shim space exceeds 1/4". FBC EC TABLE R402.4.1.1 / FBCR 609.1 4). Miscellaneous Cardboard baffles do not meet the minimum 1" air space from roof sheathing as required. FBC-R806.3. Please check all. Inspector Notes from Inspection 2320 *** NOTES ADDED BY RSIMS 4/15/2026 11:21:24 AM *** 4/15/26: Still need to check ducts at Insulation inspection. Inspector Notes from Inspection 2420 1. Missing Energy calcs. Need to recheck A/C Ducts at insulation. | |||
| INSULATION | 04/17/2026 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 4/17/2026 10:13:17 AM *** 4/17/26: 1). Missing firestop at gap in top plate to the left of laundry box. FS marked on the back side of the wall. FBC-R302.11 2). Fireblocking at the top of the bathtub pack out wall needs to be 1-1/2" thick per FBC-R302.11.1 3). Front entry door is missing foam insulation along perimeter and is missing so9lid blocking where shim space exceeds 1/4". FBC EC TABLE R402.4.1.1 / FBCR 609.1 4). Miscellaneous Cardboard baffles do not meet the minimum 1" air space from roof sheathing as required. FBC-R806.3. Please check all. Inspector Notes from Inspection 2320 *** NOTES ADDED BY RSIMS 4/15/2026 11:21:24 AM *** 4/15/26: Still need to check ducts at Insulation inspection. Inspector Notes from Inspection 2420 1. Missing Energy calcs. Need to recheck A/C Ducts at insulation. | |||
| LATH/BRICK/ WATER BARRIER | 04/15/2026 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 4/15/2026 11:21:24 AM *** 4/15/26: Still need to check ducts at Insulation inspection. Inspector Notes from Inspection 2420 1. Missing Energy calcs. Need to recheck A/C Ducts at insulation. | |||
| ELECTRIC-TUG | 04/14/2026 | APPROVED | HCAMACHO |
| Note: 4/10/2026 - PREVIOUS INSPECTION NOTES 4/10/26: 1). TUG outlet box needs to be secured to the wall. NEC-334.30 / NEC 350.30(A) | |||
| ALL ROUGH | 04/14/2026 | APPROVED - AS NOTED | HCAMACHO |
| Note: 1. Missing Energy calcs. Need to recheck A/C Ducts at insulation. | |||
| ELECTRIC-TUG | 04/10/2026 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 4/10/2026 2:34:30 PM *** 4/10/26: 1). TUG outlet box needs to be secured to the wall. NEC-334.30 / NEC 350.30(A) | |||
| WALL SHEATHING | 04/01/2026 | APPROVED | HCAMACHO |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 04/01/2026 | APPROVED - AS NOTED | HCAMACHO |
| Note: 1. T03 missing eng. See plans. | |||
| ROOF VALLEY & METAL | 04/01/2026 | APPROVED | HCAMACHO |
| ROOF SHEATHING | 03/30/2026 | APPROVED | HCAMACHO |
| Note: 3/27/2026 - PREVIOUS INSPECTION NOTES 3/27/26: NOT READY! 1). Contractors still working on installing Roof Sheathing. FBC [A]107.4 Inspector Notes from Inspection 2340 *** NOTES ADDED BY RSIMS 3/6/2026 10:22:45 AM *** 3/6/26: Deficiencies need to be repaired by next inspection. 1). Window Sill mortar beds and/or Concrete Block joints exceed the maximum thickness (sills - 1/2" / CMU joints - 3/8") per FBC-R606.3.1 > Spray painted orange. | |||
| ROOF SHEATHING | 03/27/2026 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 3/27/2026 9:46:58 AM *** 3/27/26: NOT READY! 1). Contractors still working on installing Roof Sheathing. FBC [A]107.4 Inspector Notes from Inspection 2340 *** NOTES ADDED BY RSIMS 3/6/2026 10:22:45 AM *** 3/6/26: Deficiencies need to be repaired by next inspection. 1). Window Sill mortar beds and/or Concrete Block joints exceed the maximum thickness (sills - 1/2" / CMU joints - 3/8") per FBC-R606.3.1 > Spray painted orange. | |||
| TIE BEAM / LINTEL | 03/06/2026 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 3/6/2026 10:22:45 AM *** 3/6/26: Deficiencies need to be repaired by next inspection. 1). Window Sill mortar beds and/or Concrete Block joints exceed the maximum thickness (sills - 1/2" / CMU joints - 3/8") per FBC-R606.3.1 > Spray painted orange. | |||
| MONOLITHIC SLAB | 02/27/2026 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 2/27/2026 10:18:33 AM *** 2/26/2026 - PREVIOUS INSPECTION NOTES 2/26/26: 1). No termite certification or intent to treat displayed in the permit box or on site. FBCR 318 | |||
| MONOLITHIC SLAB | 02/26/2026 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 2/26/2026 1:30:11 PM *** 2/26/26: 1). No termite certification or intent to treat displayed in the permit box or on site. FBCR 318 | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 02/24/2026 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 2/24/2026 3:12:44 PM *** 2/20/2026 - PREVIOUS INSPECTION NOTES 2/20/26: 1). Pressure test is not holding. Gauge reading @ 15psi upon arrival. Per PEX manufacturing guidelines requires 25PSI above working pressure or 100PSI minimum. FBCR P2503.7 2). Hot and Cold water are strapped together and manufacturer requires 6" minimum separation. FBC [A]107.4 | |||
| GRAVITY SEWER TEST | 02/20/2026 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 2/20/2026 9:02:09 AM *** | |||
| SEWER TIE IN | 02/20/2026 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 2/20/2026 9:02:27 AM *** | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 02/20/2026 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 2/20/2026 9:15:00 AM *** 2/20/26: 1). Pressure test is not holding. Gauge reading @ 15psi upon arrival. Per PEX manufacturing guidelines requires 25PSI above working pressure or 100PSI minimum. FBCR P2503.7 2). Hot and Cold water are strapped together and manufacturer requires 6" minimum separation. FBC [A]107.4 | |||
| FORMBOARD SURVEY (OFFICE USE ONLY) | 02/19/2026 | APPROVED | PFLANAGAN |
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 02/19/2026 | APPROVED | PKNAPIK |
| WATER METER INSTALLATION REQUEST | 02/06/2026 | APPROVED | CBOWERMASTER |
| U-CROSS CONNECTION | |||
| ROW - FINAL APRON (AFTER POUR) | |||
| ROW - FINAL INSPECTION | |||
| U -UTILITY RESIDENTIAL FINAL | |||
| BLD - BUILDING FINAL |
Review History
| Department | Status | Date In | Date Out |
| ZON | COMPLETE | 02/19/2026 | 02/19/2026 |
| Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 02/18/2026 | 02/19/2026 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 02/18/2026 | 02/19/2026 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | HOLD | 02/18/2026 | 02/18/2026 |
| Note: Held By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM Formboard survey has open form. Need to to be open form. | |||
| ENGIN1 | COMPLETE | 01/20/2026 | 01/27/2026 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 01/20/2026 | 01/20/2026 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 01/20/2026 | 01/20/2026 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 12/16/2025 | 12/18/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 12/09/2025 | 12/30/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 12/08/2025 | 12/15/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 12/08/2025 | 12/16/2025 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 12/08/2025 | 12/11/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 12/08/2025 | 12/09/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 12/08/2025 | 12/09/2025 |
| LOCATE | COMPLETE | 12/08/2025 | 12/12/2025 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | HOLD | 12/08/2025 | 12/10/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM State Card needs to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2023 8Th edition | |||
| SW1 | COMPLETE | 12/08/2025 | 12/15/2025 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Note: There is a ditch in between lot 26 and 25 with a 20' easement. No issues with proposed FFE. | |||
| ZON | COMPLETE | 12/08/2025 | 12/09/2025 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| RSI REINSPECTION 1 | ¤35.00 | 06/10/2026 |
| RSI REINSPECTION 1 | ¤35.00 | 06/10/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 06/05/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 06/05/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 06/05/2026 |
| FC IMPACT FEE EMS | ¤62.00 | 12/26/2025 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 12/26/2025 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 12/26/2025 |
| FIRE RES IMPACT FEE 10-25 | ¤942.00 | 12/26/2025 |
| PARKS IMPACT FEE 10-25 | ¤3,164.00 | 12/26/2025 |
| RSI DRIVEWAY AFTER POUR | ¤16.25 | 12/26/2025 |
| RSE DRIVE PRE POUR INSPECTION | ¤32.50 | 12/26/2025 |
| RSI FIELD SURVEY INSPECTION | ¤48.75 | 12/26/2025 |
| RSI FORMBOARD REVIEW | ¤16.25 | 12/26/2025 |
| RSI PLAN REVIEW NEW | ¤48.75 | 12/26/2025 |
| RSI FNL SURVEY/GRADING CERT | ¤48.75 | 12/26/2025 |
| WATER- TURN ON | ¤50.00 | 12/26/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 12/26/2025 |
| INSPECTION - RESIDENTIAL | ¤1,116.50 | 12/26/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤316.68 | 12/26/2025 |
| RSI ROW FINAL INSPECTION | ¤16.25 | 12/26/2025 |
| SCHOOL BOARD IMPACT FEE RES | ¤5,450.00 | 12/26/2025 |
| WASTEWATER MAIN EXTENSION IMPA | ¤2,385.00 | 12/26/2025 |
| SURCHARGE FS 533.721 | ¤14.63 | 12/26/2025 |
| SURCHARGE - FS 468.631 | ¤21.95 | 12/26/2025 |
| SW ENG RES REVIEW 240 | ¤240.00 | 12/26/2025 |
| WATER METER W/ TAP | ¤2,326.93 | 12/26/2025 |
| TRANSP RES IMPACT FEE 10-25 | ¤7,792.59 | 12/26/2025 |
| SEWER CREDIT | (¤958.00) | 12/26/2025 |
| WASTEWATER PERM INSPECTION | ¤80.00 | 12/26/2025 |
| WASTEWATER PERM REVIEW | ¤25.00 | 12/26/2025 |
| SEWER CAPITAL FACILITY | ¤4,415.00 | 12/26/2025 |
| WATER CAPITAL FACILITY FEE | ¤3,790.49 | 12/26/2025 |
| WATER PERMIT REVIEW | ¤25.00 | 12/26/2025 |
| WATER MAIN EXTENSION IMPACT | ¤917.27 | 12/26/2025 |
| SITE PLAN 30 | ¤30.00 | 12/26/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤33,140.54 |