Applicant name: SCOTT T SAREL
Owner: CURRIE GEORGE

Address

7 ROCKET LANE

PALM COAST, FL 32164

Lot: 0070
Contracted Stated Job Value: ¤21,378.84
Job Description: REMOVE AND REPLACE 6 SLIDING GLASS DOORS SIZE FOR SIZE REF 2023030985
Type: CN
Original Permit #: 2023030985

Contractor

MIRACLE WINDOWS AND SUNROOMS
Status Location Address State License Number Phone
INACTIVE

8933 WESTERN WAY

JACKSONVILLE , FL 32256

CBC1264981 (Exp: 08/31/2026) 855-232-4544

Inspection History

Type Request Date Result Inspector
FINAL - BUILDING MISC 05/02/2023 Disapproved -FEE REQUIRED JWALKER
Note: 5/2/23 Revision requested below at previous inspection has not been submitted to the building department. 2 workers onsite listed corrections have not been completed. Please ensure work is complete before calling for inspections. 4/6/2023 - PREVIOUS INSPECTION NOTES 1. The slider labels do not have the FL product approval numbers. 2. The slider openings have been furred at the header and sides the lumber used against the CMU walls and header are not pressure treated. 3. The sliders have not been fastened as per the details showing 4" from the inside corners and 16" o.c. after that. 4. The strucco has not been completed at the exterior. Please submitt a revision to the building department showing the newly added blocking and headers. Please show type of lumber and how the blocking fastens to the cmu.
FINAL - BUILDING MISC 04/06/2023 Disapproved -FEE REQUIRED JWALKER
Note: 1. The slider labels do not have the FL product approval numbers. 2. The slider openings have been furred at the header and sides the lumber used against the CMU walls and header are not pressure treated. 3. The sliders have not been fastened as per the details showing 4" from the inside corners and 16" o.c. after that. 4. The strucco has not been completed at the exterior. Please submitt a revision to the building department showing the newly added blocking and headers. Please show type of lumber and how the blocking fastens to the cmu.
FINAL - BUILDING MISC
Note: 5/2/2023 - PREVIOUS INSPECTION NOTES 5/2/23 Revision requested below at previous inspection has not been submitted to the building department. 2 workers onsite listed corrections have not been completed. Please ensure work is complete before calling for inspections. 4/6/2023 - PREVIOUS INSPECTION NOTES 1. The slider labels do not have the FL product approval numbers. 2. The slider openings have been furred at the header and sides the lumber used against the CMU walls and header are not pressure treated. 3. The sliders have not been fastened as per the details showing 4" from the inside corners and 16" o.c. after that. 4. The strucco has not been completed at the exterior. Please submitt a revision to the building department showing the newly added blocking and headers. Please show type of lumber and how the blocking fastens to the cmu.

Review History

Department Status Date In Date Out
BADMIN INFORMATION 05/08/2023 05/08/2023
Note: Marked INFORMATION By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM RENAME TO SUPPORTING DOC.PDF

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADMINISTRATIVE RESIDENTIAL ¤30.00 12/15/2025
INSPECTION - RESIDENTIAL ¤60.50 12/15/2025
REINSPECTION RESIDENTIAL ¤40.00 12/15/2025
SURCHARGE FS 533.721 ¤2.00 12/15/2025
SURCHARGE - FS 468.631 ¤2.00 12/15/2025