Permit #2025120368
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7028-00760-0010 |
| Block: 00760 |
| Subdivision: 2302 - SECTION 28-PINE GROVE |
| Job Phone: 386-931-0184 |
| Location Address: 28 POINBURY DR |
| Type: PO - POOL |
| Issue Date: 12/23/2025 |
| NOC: RECORDED |
| Applicant name: ROY C WALDHAUER |
| Owner: CHANTHAVONG VINNIE VIENG & PHENG H&W |
|
Address 28 POINBURY DRIVE PALM COAST, FL 32164 |
| Lot: 0010 |
| Contracted Stated Job Value: ¤65,000.00 |
| Job Description: SWIMMING POOL |
| Type: CN |
Contractor
BY THE SHORE INC
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| ACTIVE |
1600 N STATE STREET BUNNELL, FL 32110 |
#103 BUNNELL, FL 32110 |
CPC1457705 (Exp: 08/31/2026) | 386-446-5524 | 386-446-5107 |
Sub Contractors
CHRISTOPHER I HALL
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
P. O. Box 2413 Bunnell, FL 32110 |
EC13002161 (Exp: 08/31/2028) | (386) 437-2966 | 386-437-5042 |
ROY CHARLES WALDHAUER
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1600 N STATE STREET # 102 , 0 |
CRC1327300 (Exp: 08/31/2026) | 386-263-8272 | 386-263-8289 |
ROY CHARLES WALDHAUER II
| Status | Location Address | State License Number | Phone |
| ACTIVE |
1600 N STATE STREET # 102 BUNNELL, FL 32110 |
CPC057029 (Exp: 08/31/2026) | 386-263-8272 |
Inspection History
| Type | Request Date | Result | Inspector |
| POOL FINAL | 05/22/2026 | FINAL APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 5/22/2026 1:06:42 PM *** Final Approved 5/6/2026 - PREVIOUS INSPECTION NOTES 5/6/26: 1). two center cables for screen enclosure do not meet the Manufacturer's requirements for zero slack and need to be tightened. FBC [A]107.4 2). Downspouts need to terminate 12" minimum away from foundation/footers. FBCR 318.5 | |||
| POOL FINAL | 05/06/2026 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 5/6/2026 9:10:03 AM *** 5/6/26: 1). two center cables for screen enclosure do not meet the Manufacturer's requirements for zero slack and need to be tightened. FBC [A]107.4 2). Downspouts need to terminate 12" minimum away from foundation/footers. FBCR 318.5 | |||
| U -UTILITY RESIDENTIAL FINAL | 05/04/2026 | FINAL APPROVED | BHAINES |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 05/01/2026 | APPROVED | FSLADISH |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 05/01/2026 | APPROVED | FSLADISH |
| Note: 5/1/26 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S AND/OR HOMEOWNER’S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| ROW - FINAL INSPECTION | 05/01/2026 | APPROVED | FSLADISH |
| Note: 5/1/26 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S AND/OR HOMEOWNER’S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| ELECTRIC AND ALARM | 03/16/2026 | APPROVED | HCAMACHO |
| POOL DECK | 03/02/2026 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 3/2/2026 10:41:51 AM *** 2/27/2026 - PREVIOUS INSPECTION NOTES 2/27/26: Previously listed deficiency is still not fully resolved. Please check entire footer for rebar clearance, loose dirt removal and required dimensions. Per code footers and slab area are to be well compacted and/or undesturbed soil. FBC-R404.1.3.3.7.4 / FBC [A]107.4 2/25/2026 - PREVIOUS INSPECTION NOTES 2/24/26: Previously listed deficiency is still not fully resolved. Please check entire footer for rebar clearance, loose dirt removal and required dimensions. 2/23/2026 - PREVIOUS INSPECTION NOTES 2/23/26: 1). Dirty cave in at numerous spots throughout most of the footer needs to be cleaned out to provide required rebar clearance and meet the footer requirements on plans, etc. FBC-R404.1.3.3.7.4 / FBC [A]107.4 2/19/2026 - PREVIOUS INSPECTION NOTES 2/19/26: 1). Need roots and any debris removed from deck area. FBC R318.6.2 2). Soil needs to be tamped to meet compaction requirements. FBCR 506.2.1 3). Missing 6mil. vapor barrier against house as required. FBC R506.2.3 4). Pool deck at existing Lanai will not meet the minimum thickness listed on pool plans and / or the minimum thickness required by code. FBC R506.1 | |||
| POOL DECK | 02/27/2026 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 2/27/2026 8:58:10 AM *** 2/27/26: Previously listed deficiency is still not fully resolved. Please check entire footer for rebar clearance, loose dirt removal and required dimensions. Per code footers and slab area are to be well compacted and/or undesturbed soil. FBC-R404.1.3.3.7.4 / FBC [A]107.4 2/25/2026 - PREVIOUS INSPECTION NOTES 2/24/26: Previously listed deficiency is still not fully resolved. Please check entire footer for rebar clearance, loose dirt removal and required dimensions. 2/23/2026 - PREVIOUS INSPECTION NOTES 2/23/26: 1). Dirty cave in at numerous spots throughout most of the footer needs to be cleaned out to provide required rebar clearance and meet the footer requirements on plans, etc. FBC-R404.1.3.3.7.4 / FBC [A]107.4 2/19/2026 - PREVIOUS INSPECTION NOTES 2/19/26: 1). Need roots and any debris removed from deck area. FBC R318.6.2 2). Soil needs to be tamped to meet compaction requirements. FBCR 506.2.1 3). Missing 6mil. vapor barrier against house as required. FBC R506.2.3 4). Pool deck at existing Lanai will not meet the minimum thickness listed on pool plans and / or the minimum thickness required by code. FBC R506.1 | |||
| POOL DECK | 02/25/2026 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 2/25/2026 11:34:22 AM *** 2/24/26: Previously listed deficiency is still not fully resolved. Please check entire footer for rebar clearance, loose dirt removal and required dimensions. 2/23/2026 - PREVIOUS INSPECTION NOTES 2/23/26: 1). Dirty cave in at numerous spots throughout most of the footer needs to be cleaned out to provide required rebar clearance and meet the footer requirements on plans, etc. FBC-R404.1.3.3.7.4 / FBC [A]107.4 2/19/2026 - PREVIOUS INSPECTION NOTES 2/19/26: 1). Need roots and any debris removed from deck area. FBC R318.6.2 2). Soil needs to be tamped to meet compaction requirements. FBCR 506.2.1 3). Missing 6mil. vapor barrier against house as required. FBC R506.2.3 4). Pool deck at existing Lanai will not meet the minimum thickness listed on pool plans and / or the minimum thickness required by code. FBC R506.1 | |||
| POOL DECK | 02/23/2026 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 2/23/2026 8:57:17 AM *** 2/23/26: 1). Dirty cave in at numerous spots throughout most of the footer needs to be cleaned out to provide required rebar clearance and meet the footer requirements on plans, etc. FBC-R404.1.3.3.7.4 / FBC [A]107.4 2/19/2026 - PREVIOUS INSPECTION NOTES 2/19/26: 1). Need roots and any debris removed from deck area. FBC R318.6.2 2). Soil needs to be tamped to meet compaction requirements. FBCR 506.2.1 3). Missing 6mil. vapor barrier against house as required. FBC R506.2.3 4). Pool deck at existing Lanai will not meet the minimum thickness listed on pool plans and / or the minimum thickness required by code. FBC R506.1 | |||
| POOL DECK | 02/19/2026 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 2/19/2026 11:08:20 AM *** 2/19/26: 1). Need roots and any debris removed from deck area. FBC R318.6.2 2). Soil needs to be tamped to meet compaction requirements. FBCR 506.2.1 3). Missing 6mil. vapor barrier against house as required. FBC R506.2.3 4). Pool deck at existing Lanai will not meet the minimum thickness listed on pool plans and / or the minimum thickness required by code. FBC R506.1 | |||
| STEEL AND GROUND | 01/08/2026 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 1/8/2026 10:39:30 AM *** 1/7/2026 - PREVIOUS INSPECTION NOTES 1/7/26: 1). Please provide a ground to steel connection at spa area to assure proper conductive requirements. (or tie vertical steel from main pool to spa steel. Currently only one bar is connected.). NEC 680.26(B). | |||
| STEEL AND GROUND | 01/07/2026 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 1/7/2026 12:18:00 PM *** 1/7/26: 1). Please provide a ground to steel connection at spa area to assure proper conductive requirements. (or tie vertical steel from main pool to spa steel. Currently only one bar is connected.). NEC 680.26(B). |
Review History
| Department | Status | Date In | Date Out |
| BADMIN | INFORMATION | 04/30/2026 | 04/30/2026 |
| Note: Marked INFORMATION By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM MAIN CONTRACTOR INACTIVE, CAN NOT SCHEDULE FINAL SURVEY INSPECTION | |||
| RSI | COMPLETE | 01/22/2026 | 01/27/2026 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 01/22/2026 | 01/22/2026 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 01/22/2026 | 01/26/2026 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 12/23/2025 | 12/30/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 12/23/2025 | 12/30/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 12/23/2025 | 12/23/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 12/16/2025 | 12/18/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BFLOOD | CANCEL | 12/10/2025 | 12/12/2025 |
| BLD | HOLD | 12/10/2025 | 12/16/2025 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Master Plans are in a different contractors name. List that contractor as a sub. | |||
| ELEC | COMPLETE | 12/10/2025 | 12/15/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 12/10/2025 | 12/12/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| RSI | COMPLETE | 12/10/2025 | 12/11/2025 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 12/10/2025 | 12/10/2025 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/05/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/05/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/05/2026 |
| CONTRACTOR CHANGE | ¤20.00 | 12/23/2025 |
| RSI FIELD SURVEY INSPECTION | ¤48.75 | 12/23/2025 |
| RSI PLAN REVIEW NEW | ¤48.75 | 12/23/2025 |
| RSI FNL SURVEY/GRADING CERT | ¤48.75 | 12/23/2025 |
| RSI ROW FINAL INSPECTION | ¤16.25 | 12/23/2025 |
| SURCHARGE FS 533.721 | ¤2.55 | 12/23/2025 |
| SURCHARGE - FS 468.631 | ¤3.83 | 12/23/2025 |
| SITE PLAN 30 | ¤30.00 | 12/23/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 12/23/2025 |
| INSPECTION- POOL | ¤160.00 | 12/23/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤65.00 | 12/23/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤593.88 |