I want to search for...

Permit #2025120425

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7057-00110-0010
Block: 00110
Subdivision: 2123 - SECTION 57-ULYSSES TREES
Job Phone: 386-439-3416
Location Address: 26 UTIDE CT
Type: ME - MECHANICAL
Issue Date: 12/11/2025
NOC: Unknown
Applicant name: CHARLES WEYANT
Owner: VINING DOUGLAS & BONNIE H&W

Address

26 UTIDE COURT

PALM COAST, FL 32164

Lot: 0010
Contracted Stated Job Value: ¤12,191.00
Job Description: HVAC equipment change-out - Like for Like 3 Ton
Type: CN

Contractor

ACCU TEMP HEATING & AIR CONDITIONING INC.
Status Location Address State License Number Phone
ACTIVE

PO BOX 1261

FLAGLER BEACH, FL 32136

CAC1815058 (Exp: 08/31/2026) (386)246-7745

Inspection History

Type Request Date Result Inspector
HVAC FINAL 04/10/2026 APPROVED CVANSTRAHLEN
Note: 3/18/2026 - PREVIOUS INSPECTION NOTES 3/18/26 1. Wrong size breaker for ODU. Max 25amp and 35amp is installed NEC 440.4 2. Heat strips not marked on AH so could not verify amperage required FBCR M1303.1
HVAC FINAL 03/18/2026 Disapproved - NO FEE MCONTRYMAN
Note: 3/18/26 1. Wrong size breaker for ODU. Max 25amp and 35amp is installed NEC 440.4 2. Heat strips not marked on AH so could not verify amperage required FBCR M1303.1

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADMINISTRATIVE RESIDENTIAL ¤30.00 12/11/2025
INSPECTION - MECHANICAL ¤60.00 12/11/2025
SURCHARGE FS 533.721 ¤2.00 12/11/2025
SURCHARGE - FS 468.631 ¤2.00 12/11/2025
Fees Total Due: ¤0.00 Total Paid: ¤94.00