I want to search for...

Permit #2025120487

Permit Details

Status: INSPECT

Parcel Id: 04-11-30-5571-00000-3400
CONDITIONED SPACE: 2003 sqft
GARAGE: 477 sqft
OPENED PORCH (WITH ROOF) : 78 sqft
OPENED PORCH (WITH ROOF) : 112 sqft
Total Square Footage: 2670 sqft
Subdivision: 2366 - SOMERSET SUBDIVISION PH 2
Job Phone: 904-596-6645
Location Address: 49 SOMERSET AVE
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 01/22/2026
NOC: RECORDED
Applicant name: MICHAEL T HOLDER
Owner: KB HOME JACKSONVILLE LLC

Address

10475 FORTUNE PARKWAY

JACKSONVILLE, FL 32256

Address

SUITE 100

JACKSONVILLE, FL 32256

Lot: 340
Contracted Stated Job Value: ¤140,000.00
Job Description: SINGLE FAMILY DWELLING
Type: CN

Contractor

KB HOME JACKSONVILLE, LLC
Status Location Address Mailing Address State License Number Phone
ACTIVE

10475 FORTUNE PKWY

JACKSONVILLE, FL 32256

SUITE 100

JACKSONVILLE, FL 32256

CGC1509034 (Exp: 08/31/2026) 904-596-6645

Sub Contractors

LARRY WILLIAMS
Status Location Address State License Number Phone
ACTIVE

1750 EMERSON ST

JACKSONVILLE, FL 32207

LI45034 (Exp: 08/31/2026) 904-721-5431
JAMES E LINTON
Status Location Address State License Number Phone
ACTIVE

200 COLLEGE DR

ORANGE PARK, FL 32065

EC0001152 (Exp: 08/31/2026) 904-272-0272
BENJAMIN MICHAEL RAY
Status Location Address Mailing Address State License Number Phone Fax
ACTIVE

6310 MABLETON PKWY

JACKSONVILLE, FL 32216

SUITE 1000

MABLETON, GA 30126

CFC1428415 (Exp: 08/31/2026) 904-861-5421 904-861-5426
COREY MICHAEL TENNANT
Status Location Address State License Number Phone
ACTIVE

3370 AGRICULTURAL CNETER DR

ST AUGUSTINE, FL 32092

CAC1819063 (Exp: 08/31/2026) 904-829-8898
BOBBY WAYNE CAMPBELL
Status Location Address State License Number Phone
ACTIVE

117 GUTHRIE ROAD

GREEN COVE SPRINGS, FL 32043

CCC1326752 (Exp: 08/31/2026) 904-200-1600

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 05/27/2026 FINAL APPROVED JSTEWART
Note: 5/26/2026 - PREVIOUS INSPECTION NOTES 4/24/2026 - PREVIOUS INSPECTION NOTES 1. Left side of garage wall needs to be re graded, to much foundation wall above current grade (11"-10"). per grade and drainage plan should have 7.2" of foundation wall above grade to achieve required 12" of footing below grade. R403.1.4 2. exterior roof exhaust termination require screens (not dryer). FBC R303.6 3. Locking caps at AC need locked. FBCR M1411.8 4. Pipes at exterior tankless water heater require insulation. 5. Garage overhead door weather strip needs secured to wall (free from gaps). FBC EC TABLE R402.4.1.1 6. Please seal hole in garage wall by irrigation conduit. FBC EC TABLE R402.4.1.1 7. No Hot water in building (power is on). FBCR P2705.1 – 4 8. Master bedroom ceiling empty JB needs to be sealed off from attic air intrusion. FEBC R402.4.6 Air-sealed electrical and communication boxes.
BLD - BUILDING FINAL 05/26/2026 CANCELLED BY APPLICANT HCAMACHO
Note: 4/24/2026 - PREVIOUS INSPECTION NOTES 1. Left side of garage wall needs to be re graded, to much foundation wall above current grade (11"-10"). per grade and drainage plan should have 7.2" of foundation wall above grade to achieve required 12" of footing below grade. R403.1.4 2. exterior roof exhaust termination require screens (not dryer). FBC R303.6 3. Locking caps at AC need locked. FBCR M1411.8 4. Pipes at exterior tankless water heater require insulation. 5. Garage overhead door weather strip needs secured to wall (free from gaps). FBC EC TABLE R402.4.1.1 6. Please seal hole in garage wall by irrigation conduit. FBC EC TABLE R402.4.1.1 7. No Hot water in building (power is on). FBCR P2705.1 – 4 8. Master bedroom ceiling empty JB needs to be sealed off from attic air intrusion. FEBC R402.4.6 Air-sealed electrical and communication boxes.
ROW- FINAL SURVEY/GRADING CERTIFICATION 05/14/2026 Disapproved - NO FEE RRICKS
Note: 5/14/2026 - RRicks Checklist Item 23: As discussed with Fidel and Scott, the approved master plan and the approved grading plan have this lot as an A-type NOT a B-type. Gabriel and I conducted a site visit and there is severe erosion on 49,51, and 53 where the ground was disturbed and new sod was installed. Please make all necessary corrections as soon as possible.
ROW- PROJECT STATUS 05/14/2026 APPROVED - AS NOTED RRICKS
Note: 5/14/2026 - RRicks Gabriel and I conducted a site visit and there is severe erosion on 49,51, and 53 where the ground was disturbed and new sod was installed. Please make all necessary corrections as soon as possible.
U-CROSS CONNECTION 04/24/2026 APPROVED - AS NOTED BHAINES
Note: No CC, IRR with reclaim
BLD - BUILDING FINAL 04/24/2026 Disapproved -FEE REQUIRED JSTEWART
Note: 1. Left side of garage wall needs to be re graded, to much foundation wall above current grade (11"-10"). per grade and drainage plan should have 7.2" of foundation wall above grade to achieve required 12" of footing below grade. R403.1.4 2. exterior roof exhaust termination require screens (not dryer). FBC R303.6 3. Locking caps at AC need locked. FBCR M1411.8 4. Pipes at exterior tankless water heater require insulation. 5. Garage overhead door weather strip needs secured to wall (free from gaps). FBC EC TABLE R402.4.1.1 6. Please seal hole in garage wall by irrigation conduit. FBC EC TABLE R402.4.1.1 7. No Hot water in building (power is on). FBCR P2705.1 – 4 8. Master bedroom ceiling empty JB needs to be sealed off from attic air intrusion. FEBC R402.4.6 Air-sealed electrical and communication boxes.
ELECTRIC - EARLY POWER 04/02/2026 APPROVED JSTEWART
Note: 3/30/2026 - PREVIOUS INSPECTION NOTES 1. (2) front entry coach lights need caps and covered. NEC 110.27 2. bedroom 1....3way light switch needs a faceplate. NEC 110.27 3. bedroom 2....3way light switch needs a faceplate. NEC 110.27 4. bedroom 3....3way light switch needs a faceplate. NEC 110.27 5. Dryer receptacle needs a faceplate. NEC 110.27 Inspector Notes from Inspection 2200 Authorize release of email.
ELECTRIC - EARLY POWER 03/30/2026 Disapproved -FEE REQUIRED JSTEWART
Note: 1. (2) front entry coach lights need caps and covered. NEC 110.27 2. bedroom 1....3way light switch needs a faceplate. NEC 110.27 3. bedroom 2....3way light switch needs a faceplate. NEC 110.27 4. bedroom 3....3way light switch needs a faceplate. NEC 110.27 5. Dryer receptacle needs a faceplate. NEC 110.27 Inspector Notes from Inspection 2200 Authorize release of email.
LATH/BRICK/ WATER BARRIER 03/23/2026 APPROVED JSTEWART
ROW- PRE-APRON (PRE-POUR) 03/11/2026 APPROVED - AS NOTED EMADISON
Note: ** 03/11/26 ** READY TO POUR ** AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE
DRYWALL NAILING 03/09/2026 APPROVED JSTEWART
Note: 3/6/2026 - PREVIOUS INSPECTION NOTES Bedroom behind garage, 4ft sheet not fastened between door and closet.
DRYWALL NAILING 03/06/2026 Disapproved - NO FEE JSTEWART
Note: Bedroom behind garage, 4ft sheet not fastened between door and closet.
INSULATION 03/04/2026 APPROVED JSTEWART
Note: Previous Notes not rectified.......If not rectified by Insulation Inspection, approval cannot be given. 1. Romex entering outlet boxes required min 1/4" of the sheathing min in box. multiple all over need fixed. NEC 314.17(C) 2. SD/CO in hallway at AHU closet is not wired. per plan / FBCR 314 & 315 (Exterior walls outlet boxes are good, interior wall and ceiling boxes).
LATH/BRICK/ WATER BARRIER 03/04/2026 APPROVED JSTEWART
Note: 3/2/2026 - PREVIOUS INSPECTION NOTES On back wall, appears AC power was relocated Please seal Hole in Plywood, and install water barrier at relocated romex.
LATH/BRICK/ WATER BARRIER 03/02/2026 Disapproved - NO FEE JSTEWART
Note: On back wall, appears AC power was relocated Please seal Hole in Plywood, and install water barrier at relocated romex.
ALL ROUGH 03/02/2026 APPROVED - AS NOTED JSTEWART
Note: Previous Notes not rectified.......If not rectified by Insulation Inspection, approval cannot be given. 1. Romex entering outlet boxes required min 1/4" of the sheathing min in box. multiple all over need fixed. NEC 314.17(C) 2. SD/CO in hallway at AHU closet is not wired. per plan / FBCR 314 & 315 (Exterior walls outlet boxes are good, interior wall and ceiling boxes). 2/26/2026 - PREVIOUS INSPECTION NOTES 1. Romex entering outlet boxes required min 1/4" of the sheathing min in box. multiple all over need fixed. NEC 314.17(C) 2. SD/CO in hallway at AHU closet is not wired. per plan / FBCR 314 & 315 3. No 5ft head. FBCR P2503.5 4. very low water preassure. FBCR P2503.7 5. install mechanical fasteners at all bath fan exhaust duct to assembly. FBCR M1601.4.1 6. hood duct requires (3) screws at lap joint. FBCR M1601.4.1 7. Air supply duct required 1 1/2" clearence from roof deck. FBC 1510.12
ALL ROUGH 02/26/2026 Disapproved - NO FEE JSTEWART
Note: 1. Romex entering outlet boxes required min 1/4" of the sheathing min in box. multiple all over need fixed. NEC 314.17(C) 2. SD/CO in hallway at AHU closet is not wired. per plan / FBCR 314 & 315 3. No 5ft head. FBCR P2503.5 4. very low water preassure. FBCR P2503.7 5. install mechanical fasteners at all bath fan exhaust duct to assembly. FBCR M1601.4.1 6. hood duct requires (3) screws at lap joint. FBCR M1601.4.1 7. Air supply duct required 1 1/2" clearence from roof deck. FBC 1510.12
ROOF VALLEY & METAL 02/26/2026 APPROVED JSTEWART
ELECTRIC-TUG 02/25/2026 APPROVED - AS NOTED JSTEWART
Note: Authorize release of email.
SEWER TIE IN 02/20/2026 APPROVED JSTEWART
Note: onsite inspection. 2/9/2026 - PREVIOUS INSPECTION NOTES
GRAVITY SEWER TEST 02/20/2026 APPROVED JSTEWART
Note: onsite inspection. 2/9/2026 - PREVIOUS INSPECTION NOTES
WALL SHEATHING 02/20/2026 APPROVED JSTEWART
ROOF SHEATHING / BRACES/TIES/DOWN CELL 02/20/2026 APPROVED JSTEWART
SEWER TIE IN 02/09/2026 CANCELLED BY APPLICANT JSTEWART
GRAVITY SEWER TEST 02/09/2026 CANCELLED BY APPLICANT JSTEWART
MONOLITHIC SLAB 02/05/2026 APPROVED JSTEWART
Note: Live Virtual inspection, Correction was completed. 2/4/2026 - PREVIOUS INSPECTION NOTES Missing footing for interior bearing wall in location of Bedroom 2 and bedroom 2. per plans Page S1, for deatil SD1 H.
MONOLITHIC SLAB 02/04/2026 Disapproved - NO FEE JSTEWART
Note: Missing footing for interior bearing wall in location of Bedroom 2 and bedroom 2. per plans Page S1, for deatil SD1 H.
PLUMBING 1ST ROUGH UNDERGROUND 02/02/2026 APPROVED JSTEWART
WATER METER INSTALLATION REQUEST 02/02/2026 APPROVED BVITALE
FORMBOARD SURVEY (OFFICE USE ONLY) 01/30/2026 APPROVED RRICKS
ROW - FINAL APRON (AFTER POUR)
ROW- FINAL SURVEY/GRADING CERTIFICATION
Note: 5/14/2026 8:43:28 AM- PREVIOUS INSPECTION NOTES 5/14/2026 - RRicks Checklist Item 23: As discussed with Fidel and Scott, the approved master plan and the approved grading plan have this lot as an A-type NOT a B-type. Gabriel and I conducted a site visit and there is severe erosion on 49,51, and 53 where the ground was disturbed and new sod was installed. Please make all necessary corrections as soon as possible.
ROW - FINAL INSPECTION
U -UTILITY RESIDENTIAL FINAL

Review History

Department Status Date In Date Out
SW1 COMPLETE 01/30/2026 01/30/2026
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 01/30/2026 01/30/2026
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
SW1 COMPLETE 01/15/2026 01/15/2026
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Approved as noted: Grading plan does not SDMFD by 0.2', please ensure that no considerable deviations are made to the FFE affecting the grades.
BADMIN INFORMATION 01/06/2026 01/06/2026
Note: Marked INFORMATION By: JAZMIN ROSARIO - - JROSARIO@PALMCOASTGOV.COM REVISION FORM SUBMITTED BUT NO UPDATED DOCUMENTS FOR REVIEW.
BLD COMPLETE 12/15/2025 12/18/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
CUSVC COMPLETE 12/15/2025 12/19/2025
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 12/15/2025 12/16/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 12/15/2025 12/16/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS COMPLETE 12/15/2025 12/16/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
LOCATE COMPLETE 12/15/2025 12/22/2025
Note: Released By: TONI CHURCHILL - - TCHURCHILL@PALMCOASTGOV.COM
MECH COMPLETE 12/15/2025 12/16/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 HOLD 12/15/2025 12/16/2025
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM The lots on this street were submitted for the SDMFD #6508. Please submit add these to the modification request.
ZON COMPLETE 12/15/2025 12/16/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
URB COMPLETE 12/15/2025 12/18/2025
Note: Released By: JOHN BEAUDET - (386)986-2456 - JBEAUDET@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
FC IMPACT FEE EMS ¤62.00 01/22/2026
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 01/22/2026
FC IMPACT FEE LIBRARY ¤268.00 01/22/2026
FIRE RES IMPACT FEE 10-25 ¤942.00 01/22/2026
WATER METER W/OUT TAP ¤965.03 01/22/2026
PARKS IMPACT FEE 10-25 ¤3,164.00 01/22/2026
RECLAIM WATER PERMIT INSPECTIO ¤40.00 01/22/2026
RSI DRIVEWAY AFTER POUR ¤16.25 01/22/2026
RSE DRIVE PRE POUR INSPECTION ¤32.50 01/22/2026
RSI FIELD SURVEY INSPECTION ¤48.75 01/22/2026
RSI FORMBOARD REVIEW ¤16.25 01/22/2026
RSI PLAN REVIEW NEW ¤48.75 01/22/2026
RSI FNL SURVEY/GRADING CERT ¤48.75 01/22/2026
RSI ROW FINAL INSPECTION ¤16.25 01/22/2026
SCHOOL BOARD IMPACT FEE RES ¤5,450.00 01/22/2026
SURCHARGE FS 533.721 ¤14.03 01/22/2026
SURCHARGE - FS 468.631 ¤21.05 01/22/2026
TRANSP RES IMPACT FEE 10-25 ¤7,551.31 01/22/2026
WASTEWATER PERM INSPECTION ¤80.00 01/22/2026
WASTEWATER PERM REVIEW ¤25.00 01/22/2026
SEWER CAPITAL FACILITY ¤3,628.86 01/22/2026
WATER CAPITAL FACILITY FEE ¤3,091.14 01/22/2026
WATER PERMIT REVIEW ¤25.00 01/22/2026
SITE PLAN 30 ¤30.00 01/22/2026
WATER-METER ¤874.47 01/22/2026
WATER- TURN ON ¤50.00 01/22/2026
ADMINISTRATIVE RESIDENTIAL ¤30.00 01/22/2026
INSPECTION - RESIDENTIAL ¤1,069.75 01/22/2026
PLAN REVIEW - RESIDENTIAL ¤303.42 01/22/2026
REINSPECTION RESIDENTIAL ¤40.00
REINSPECTION RESIDENTIAL ¤40.00
Fees Total Due: ¤80.00 Total Paid: ¤28,130.56