I want to search for...
Permit #2025120487
Permit Details
Status: INSPECT
| Parcel Id: 04-11-30-5571-00000-3400 |
| CONDITIONED SPACE: 2003 sqft |
| GARAGE: 477 sqft |
| OPENED PORCH (WITH ROOF) : 78 sqft |
| OPENED PORCH (WITH ROOF) : 112 sqft |
| Total Square Footage: 2670 sqft |
| Subdivision: 2366 - SOMERSET SUBDIVISION PH 2 |
| Job Phone: 904-596-6645 |
| Location Address: 49 SOMERSET AVE |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 01/22/2026 |
| NOC: RECORDED |
| Applicant name: MICHAEL T HOLDER |
| Owner: KB HOME JACKSONVILLE LLC |
|
Address 10475 FORTUNE PARKWAY JACKSONVILLE, FL 32256 |
|
Address SUITE 100 JACKSONVILLE, FL 32256 |
| Lot: 340 |
| Contracted Stated Job Value: ¤140,000.00 |
| Job Description: SINGLE FAMILY DWELLING |
| Type: CN |
Contractor
KB HOME JACKSONVILLE, LLC
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
10475 FORTUNE PKWY JACKSONVILLE, FL 32256 |
SUITE 100 JACKSONVILLE, FL 32256 |
CGC1509034 (Exp: 08/31/2026) | 904-596-6645 |
Sub Contractors
LARRY WILLIAMS
| Status | Location Address | State License Number | Phone |
| ACTIVE |
1750 EMERSON ST JACKSONVILLE, FL 32207 |
LI45034 (Exp: 08/31/2026) | 904-721-5431 |
JAMES E LINTON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
200 COLLEGE DR ORANGE PARK, FL 32065 |
EC0001152 (Exp: 08/31/2026) | 904-272-0272 |
BENJAMIN MICHAEL RAY
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| ACTIVE |
6310 MABLETON PKWY JACKSONVILLE, FL 32216 |
SUITE 1000 MABLETON, GA 30126 |
CFC1428415 (Exp: 08/31/2026) | 904-861-5421 | 904-861-5426 |
COREY MICHAEL TENNANT
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3370 AGRICULTURAL CNETER DR ST AUGUSTINE, FL 32092 |
CAC1819063 (Exp: 08/31/2026) | 904-829-8898 |
BOBBY WAYNE CAMPBELL
| Status | Location Address | State License Number | Phone |
| ACTIVE |
117 GUTHRIE ROAD GREEN COVE SPRINGS, FL 32043 |
CCC1326752 (Exp: 08/31/2026) | 904-200-1600 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 05/27/2026 | FINAL APPROVED | JSTEWART |
| Note: 5/26/2026 - PREVIOUS INSPECTION NOTES 4/24/2026 - PREVIOUS INSPECTION NOTES 1. Left side of garage wall needs to be re graded, to much foundation wall above current grade (11"-10"). per grade and drainage plan should have 7.2" of foundation wall above grade to achieve required 12" of footing below grade. R403.1.4 2. exterior roof exhaust termination require screens (not dryer). FBC R303.6 3. Locking caps at AC need locked. FBCR M1411.8 4. Pipes at exterior tankless water heater require insulation. 5. Garage overhead door weather strip needs secured to wall (free from gaps). FBC EC TABLE R402.4.1.1 6. Please seal hole in garage wall by irrigation conduit. FBC EC TABLE R402.4.1.1 7. No Hot water in building (power is on). FBCR P2705.1 – 4 8. Master bedroom ceiling empty JB needs to be sealed off from attic air intrusion. FEBC R402.4.6 Air-sealed electrical and communication boxes. | |||
| BLD - BUILDING FINAL | 05/26/2026 | CANCELLED BY APPLICANT | HCAMACHO |
| Note: 4/24/2026 - PREVIOUS INSPECTION NOTES 1. Left side of garage wall needs to be re graded, to much foundation wall above current grade (11"-10"). per grade and drainage plan should have 7.2" of foundation wall above grade to achieve required 12" of footing below grade. R403.1.4 2. exterior roof exhaust termination require screens (not dryer). FBC R303.6 3. Locking caps at AC need locked. FBCR M1411.8 4. Pipes at exterior tankless water heater require insulation. 5. Garage overhead door weather strip needs secured to wall (free from gaps). FBC EC TABLE R402.4.1.1 6. Please seal hole in garage wall by irrigation conduit. FBC EC TABLE R402.4.1.1 7. No Hot water in building (power is on). FBCR P2705.1 – 4 8. Master bedroom ceiling empty JB needs to be sealed off from attic air intrusion. FEBC R402.4.6 Air-sealed electrical and communication boxes. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 05/14/2026 | Disapproved - NO FEE | RRICKS |
| Note: 5/14/2026 - RRicks Checklist Item 23: As discussed with Fidel and Scott, the approved master plan and the approved grading plan have this lot as an A-type NOT a B-type. Gabriel and I conducted a site visit and there is severe erosion on 49,51, and 53 where the ground was disturbed and new sod was installed. Please make all necessary corrections as soon as possible. | |||
| ROW- PROJECT STATUS | 05/14/2026 | APPROVED - AS NOTED | RRICKS |
| Note: 5/14/2026 - RRicks Gabriel and I conducted a site visit and there is severe erosion on 49,51, and 53 where the ground was disturbed and new sod was installed. Please make all necessary corrections as soon as possible. | |||
| U-CROSS CONNECTION | 04/24/2026 | APPROVED - AS NOTED | BHAINES |
| Note: No CC, IRR with reclaim | |||
| BLD - BUILDING FINAL | 04/24/2026 | Disapproved -FEE REQUIRED | JSTEWART |
| Note: 1. Left side of garage wall needs to be re graded, to much foundation wall above current grade (11"-10"). per grade and drainage plan should have 7.2" of foundation wall above grade to achieve required 12" of footing below grade. R403.1.4 2. exterior roof exhaust termination require screens (not dryer). FBC R303.6 3. Locking caps at AC need locked. FBCR M1411.8 4. Pipes at exterior tankless water heater require insulation. 5. Garage overhead door weather strip needs secured to wall (free from gaps). FBC EC TABLE R402.4.1.1 6. Please seal hole in garage wall by irrigation conduit. FBC EC TABLE R402.4.1.1 7. No Hot water in building (power is on). FBCR P2705.1 – 4 8. Master bedroom ceiling empty JB needs to be sealed off from attic air intrusion. FEBC R402.4.6 Air-sealed electrical and communication boxes. | |||
| ELECTRIC - EARLY POWER | 04/02/2026 | APPROVED | JSTEWART |
| Note: 3/30/2026 - PREVIOUS INSPECTION NOTES 1. (2) front entry coach lights need caps and covered. NEC 110.27 2. bedroom 1....3way light switch needs a faceplate. NEC 110.27 3. bedroom 2....3way light switch needs a faceplate. NEC 110.27 4. bedroom 3....3way light switch needs a faceplate. NEC 110.27 5. Dryer receptacle needs a faceplate. NEC 110.27 Inspector Notes from Inspection 2200 Authorize release of email. | |||
| ELECTRIC - EARLY POWER | 03/30/2026 | Disapproved -FEE REQUIRED | JSTEWART |
| Note: 1. (2) front entry coach lights need caps and covered. NEC 110.27 2. bedroom 1....3way light switch needs a faceplate. NEC 110.27 3. bedroom 2....3way light switch needs a faceplate. NEC 110.27 4. bedroom 3....3way light switch needs a faceplate. NEC 110.27 5. Dryer receptacle needs a faceplate. NEC 110.27 Inspector Notes from Inspection 2200 Authorize release of email. | |||
| LATH/BRICK/ WATER BARRIER | 03/23/2026 | APPROVED | JSTEWART |
| ROW- PRE-APRON (PRE-POUR) | 03/11/2026 | APPROVED - AS NOTED | EMADISON |
| Note: ** 03/11/26 ** READY TO POUR ** AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE | |||
| DRYWALL NAILING | 03/09/2026 | APPROVED | JSTEWART |
| Note: 3/6/2026 - PREVIOUS INSPECTION NOTES Bedroom behind garage, 4ft sheet not fastened between door and closet. | |||
| DRYWALL NAILING | 03/06/2026 | Disapproved - NO FEE | JSTEWART |
| Note: Bedroom behind garage, 4ft sheet not fastened between door and closet. | |||
| INSULATION | 03/04/2026 | APPROVED | JSTEWART |
| Note: Previous Notes not rectified.......If not rectified by Insulation Inspection, approval cannot be given. 1. Romex entering outlet boxes required min 1/4" of the sheathing min in box. multiple all over need fixed. NEC 314.17(C) 2. SD/CO in hallway at AHU closet is not wired. per plan / FBCR 314 & 315 (Exterior walls outlet boxes are good, interior wall and ceiling boxes). | |||
| LATH/BRICK/ WATER BARRIER | 03/04/2026 | APPROVED | JSTEWART |
| Note: 3/2/2026 - PREVIOUS INSPECTION NOTES On back wall, appears AC power was relocated Please seal Hole in Plywood, and install water barrier at relocated romex. | |||
| LATH/BRICK/ WATER BARRIER | 03/02/2026 | Disapproved - NO FEE | JSTEWART |
| Note: On back wall, appears AC power was relocated Please seal Hole in Plywood, and install water barrier at relocated romex. | |||
| ALL ROUGH | 03/02/2026 | APPROVED - AS NOTED | JSTEWART |
| Note: Previous Notes not rectified.......If not rectified by Insulation Inspection, approval cannot be given. 1. Romex entering outlet boxes required min 1/4" of the sheathing min in box. multiple all over need fixed. NEC 314.17(C) 2. SD/CO in hallway at AHU closet is not wired. per plan / FBCR 314 & 315 (Exterior walls outlet boxes are good, interior wall and ceiling boxes). 2/26/2026 - PREVIOUS INSPECTION NOTES 1. Romex entering outlet boxes required min 1/4" of the sheathing min in box. multiple all over need fixed. NEC 314.17(C) 2. SD/CO in hallway at AHU closet is not wired. per plan / FBCR 314 & 315 3. No 5ft head. FBCR P2503.5 4. very low water preassure. FBCR P2503.7 5. install mechanical fasteners at all bath fan exhaust duct to assembly. FBCR M1601.4.1 6. hood duct requires (3) screws at lap joint. FBCR M1601.4.1 7. Air supply duct required 1 1/2" clearence from roof deck. FBC 1510.12 | |||
| ALL ROUGH | 02/26/2026 | Disapproved - NO FEE | JSTEWART |
| Note: 1. Romex entering outlet boxes required min 1/4" of the sheathing min in box. multiple all over need fixed. NEC 314.17(C) 2. SD/CO in hallway at AHU closet is not wired. per plan / FBCR 314 & 315 3. No 5ft head. FBCR P2503.5 4. very low water preassure. FBCR P2503.7 5. install mechanical fasteners at all bath fan exhaust duct to assembly. FBCR M1601.4.1 6. hood duct requires (3) screws at lap joint. FBCR M1601.4.1 7. Air supply duct required 1 1/2" clearence from roof deck. FBC 1510.12 | |||
| ROOF VALLEY & METAL | 02/26/2026 | APPROVED | JSTEWART |
| ELECTRIC-TUG | 02/25/2026 | APPROVED - AS NOTED | JSTEWART |
| Note: Authorize release of email. | |||
| SEWER TIE IN | 02/20/2026 | APPROVED | JSTEWART |
| Note: onsite inspection. 2/9/2026 - PREVIOUS INSPECTION NOTES | |||
| GRAVITY SEWER TEST | 02/20/2026 | APPROVED | JSTEWART |
| Note: onsite inspection. 2/9/2026 - PREVIOUS INSPECTION NOTES | |||
| WALL SHEATHING | 02/20/2026 | APPROVED | JSTEWART |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/20/2026 | APPROVED | JSTEWART |
| SEWER TIE IN | 02/09/2026 | CANCELLED BY APPLICANT | JSTEWART |
| GRAVITY SEWER TEST | 02/09/2026 | CANCELLED BY APPLICANT | JSTEWART |
| MONOLITHIC SLAB | 02/05/2026 | APPROVED | JSTEWART |
| Note: Live Virtual inspection, Correction was completed. 2/4/2026 - PREVIOUS INSPECTION NOTES Missing footing for interior bearing wall in location of Bedroom 2 and bedroom 2. per plans Page S1, for deatil SD1 H. | |||
| MONOLITHIC SLAB | 02/04/2026 | Disapproved - NO FEE | JSTEWART |
| Note: Missing footing for interior bearing wall in location of Bedroom 2 and bedroom 2. per plans Page S1, for deatil SD1 H. | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 02/02/2026 | APPROVED | JSTEWART |
| WATER METER INSTALLATION REQUEST | 02/02/2026 | APPROVED | BVITALE |
| FORMBOARD SURVEY (OFFICE USE ONLY) | 01/30/2026 | APPROVED | RRICKS |
| ROW - FINAL APRON (AFTER POUR) | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | |||
| Note: 5/14/2026 8:43:28 AM- PREVIOUS INSPECTION NOTES 5/14/2026 - RRicks Checklist Item 23: As discussed with Fidel and Scott, the approved master plan and the approved grading plan have this lot as an A-type NOT a B-type. Gabriel and I conducted a site visit and there is severe erosion on 49,51, and 53 where the ground was disturbed and new sod was installed. Please make all necessary corrections as soon as possible. | |||
| ROW - FINAL INSPECTION | |||
| U -UTILITY RESIDENTIAL FINAL |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 01/30/2026 | 01/30/2026 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 01/30/2026 | 01/30/2026 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 01/15/2026 | 01/15/2026 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Approved as noted: Grading plan does not SDMFD by 0.2', please ensure that no considerable deviations are made to the FFE affecting the grades. | |||
| BADMIN | INFORMATION | 01/06/2026 | 01/06/2026 |
| Note: Marked INFORMATION By: JAZMIN ROSARIO - - JROSARIO@PALMCOASTGOV.COM REVISION FORM SUBMITTED BUT NO UPDATED DOCUMENTS FOR REVIEW. | |||
| BLD | COMPLETE | 12/15/2025 | 12/18/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 12/15/2025 | 12/19/2025 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 12/15/2025 | 12/16/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 12/15/2025 | 12/16/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| GAS | COMPLETE | 12/15/2025 | 12/16/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 12/15/2025 | 12/22/2025 |
| Note: Released By: TONI CHURCHILL - - TCHURCHILL@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 12/15/2025 | 12/16/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 12/15/2025 | 12/16/2025 |
| Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM The lots on this street were submitted for the SDMFD #6508. Please submit add these to the modification request. | |||
| ZON | COMPLETE | 12/15/2025 | 12/16/2025 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| URB | COMPLETE | 12/15/2025 | 12/18/2025 |
| Note: Released By: JOHN BEAUDET - (386)986-2456 - JBEAUDET@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| FC IMPACT FEE EMS | ¤62.00 | 01/22/2026 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 01/22/2026 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 01/22/2026 |
| FIRE RES IMPACT FEE 10-25 | ¤942.00 | 01/22/2026 |
| WATER METER W/OUT TAP | ¤965.03 | 01/22/2026 |
| PARKS IMPACT FEE 10-25 | ¤3,164.00 | 01/22/2026 |
| RECLAIM WATER PERMIT INSPECTIO | ¤40.00 | 01/22/2026 |
| RSI DRIVEWAY AFTER POUR | ¤16.25 | 01/22/2026 |
| RSE DRIVE PRE POUR INSPECTION | ¤32.50 | 01/22/2026 |
| RSI FIELD SURVEY INSPECTION | ¤48.75 | 01/22/2026 |
| RSI FORMBOARD REVIEW | ¤16.25 | 01/22/2026 |
| RSI PLAN REVIEW NEW | ¤48.75 | 01/22/2026 |
| RSI FNL SURVEY/GRADING CERT | ¤48.75 | 01/22/2026 |
| RSI ROW FINAL INSPECTION | ¤16.25 | 01/22/2026 |
| SCHOOL BOARD IMPACT FEE RES | ¤5,450.00 | 01/22/2026 |
| SURCHARGE FS 533.721 | ¤14.03 | 01/22/2026 |
| SURCHARGE - FS 468.631 | ¤21.05 | 01/22/2026 |
| TRANSP RES IMPACT FEE 10-25 | ¤7,551.31 | 01/22/2026 |
| WASTEWATER PERM INSPECTION | ¤80.00 | 01/22/2026 |
| WASTEWATER PERM REVIEW | ¤25.00 | 01/22/2026 |
| SEWER CAPITAL FACILITY | ¤3,628.86 | 01/22/2026 |
| WATER CAPITAL FACILITY FEE | ¤3,091.14 | 01/22/2026 |
| WATER PERMIT REVIEW | ¤25.00 | 01/22/2026 |
| SITE PLAN 30 | ¤30.00 | 01/22/2026 |
| WATER-METER | ¤874.47 | 01/22/2026 |
| WATER- TURN ON | ¤50.00 | 01/22/2026 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 01/22/2026 |
| INSPECTION - RESIDENTIAL | ¤1,069.75 | 01/22/2026 |
| PLAN REVIEW - RESIDENTIAL | ¤303.42 | 01/22/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | |
| REINSPECTION RESIDENTIAL | ¤40.00 | |
| Fees | Total Due: ¤80.00 | Total Paid: ¤28,130.56 |