I want to search for...
Permit #2025120490
Permit Details
Status: COED
| Parcel Id: 04-11-30-5570-00000-2430 |
| CONDITIONED SPACE: 1707 sqft |
| GARAGE: 437 sqft |
| OPENED PORCH (WITH ROOF) : 64 sqft |
| OPENED PORCH (WITH ROOF) : 220 sqft |
| Total Square Footage: 2428 sqft |
| Subdivision: 2326 - SOMERSET SUBDIVISION PH 1 |
| Job Phone: 904-596-6645 |
| Location Address: 38 CAMELLIA ST |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 12/23/2025 |
| NOC: RECORDED |
| Applicant name: MICHAEL T HOLDER |
| Owner: KB HOME JACKSONVILLE LLC |
|
Address 10475 FORTUNE PARKWAY JACKSONVILLE, FL 32256 |
|
Address SUITE 100 JACKSONVILLE, FL 32256 |
| Lot: 243 |
| Contracted Stated Job Value: ¤140,000.00 |
| Job Description: SINGLE FAMILY DWELLING |
| Type: CN |
Contractor
KB HOME JACKSONVILLE, LLC
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
10475 FORTUNE PKWY JACKSONVILLE, FL 32256 |
SUITE 100 JACKSONVILLE, FL 32256 |
CGC1509034 (Exp: 08/31/2026) | 904-596-6645 |
Sub Contractors
BOBBY WAYNE CAMPBELL
| Status | Location Address | State License Number | Phone |
| ACTIVE |
117 GUTHRIE ROAD GREEN COVE SPRINGS, FL 32043 |
CCC1326752 (Exp: 08/31/2026) | 904-200-1600 |
JAMES E LINTON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
200 COLLEGE DR ORANGE PARK, FL 32065 |
EC0001152 (Exp: 08/31/2026) | 904-272-0272 |
LARRY WILLIAMS
| Status | Location Address | State License Number | Phone |
| ACTIVE |
1750 EMERSON ST JACKSONVILLE, FL 32207 |
LI45034 (Exp: 08/31/2026) | 904-721-5431 |
COREY MICHAEL TENNANT
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3370 AGRICULTURAL CNETER DR ST AUGUSTINE, FL 32092 |
CAC1819063 (Exp: 08/31/2026) | 904-829-8898 |
BENJAMIN MICHAEL RAY
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| ACTIVE |
6310 MABLETON PKWY JACKSONVILLE, FL 32216 |
SUITE 1000 MABLETON, GA 30126 |
CFC1428415 (Exp: 08/31/2026) | 904-861-5421 | 904-861-5426 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 04/10/2026 | FINAL APPROVED | JSTEWART |
| Note: Note: Dirt was installed, and grade was raised to achieve the min 12" of footing below finish grade. 4/9/2026 - PREVIOUS INSPECTION NOTES Previous Note not rectified........ 1. The 2 front corners of foundation and going down the sides have 12" +/- of foundation wall above finished grade, creating the possibility of bottom of footer is not the required 12" below finish grade (going off of Grade plan submitted and approved). Please repair. NOTE: Builder removed dirt on right side of Home to reveal Bottom of footing, measurement was aproximatly 7"+/-. This does not meet FBC R403.1.4 for a min of 12" below grade. Findings have been sent to supervisor for further review. 4/7/2026 - PREVIOUS INSPECTION NOTES 3/25/2026 - PREVIOUS INSPECTION NOTES 1. The 2 front corners of foundation and going down the sides have 12" +/- of foundation wall above finished grade, creating the possibility of bottom of footer is not the required 12" below finish grade (going off of Grade plan submitted and approved). Please repair. 2. install anti tip bracket. FBCR M1901.2 3. Install screens at roof exhaust terminations (Not the dryer). FBC R303.6 4. No Hot water in home. FBCR P2722.2 5. Please seal master tub at wall (large gap framing exposed). FBCR P2705.1 6. Master tub Missing overflow cover. FBCR P2705.1 – 4 | |||
| BLD - BUILDING FINAL | 04/09/2026 | Disapproved - NO FEE | JSTEWART |
| Note: Previous Note not rectified........ 1. The 2 front corners of foundation and going down the sides have 12" +/- of foundation wall above finished grade, creating the possibility of bottom of footer is not the required 12" below finish grade (going off of Grade plan submitted and approved). Please repair. NOTE: Builder removed dirt on right side of Home to reveal Bottom of footing, measurement was aproximatly 7"+/-. This does not meet FBC R403.1.4 for a min of 12" below grade. Findings have been sent to supervisor for further review. 4/7/2026 - PREVIOUS INSPECTION NOTES 3/25/2026 - PREVIOUS INSPECTION NOTES 1. The 2 front corners of foundation and going down the sides have 12" +/- of foundation wall above finished grade, creating the possibility of bottom of footer is not the required 12" below finish grade (going off of Grade plan submitted and approved). Please repair. 2. install anti tip bracket. FBCR M1901.2 3. Install screens at roof exhaust terminations (Not the dryer). FBC R303.6 4. No Hot water in home. FBCR P2722.2 5. Please seal master tub at wall (large gap framing exposed). FBCR P2705.1 6. Master tub Missing overflow cover. FBCR P2705.1 – 4 | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 04/08/2026 | APPROVED | EMADISON |
| Note: ** Effective 03/25/26, the ROW Field Survey requirement is no longer in effect for Final Lot Grading and Drainage Certificates for new construction on subdivision and infill lots. All Final Lot Grading and Drainage Certificates for these projects will now be reviewed and approved only in the office. Field verification for the ROW-FIELD SURVEY will no longer be required as part of the standard approval process for these permit types. ** PER P. BUCKLEY CHIEF BUILDING Inspector. ** SCHEDULE YOUR FINALS WHEN YOU ARE READY TO DO SO | |||
| BLD - BUILDING FINAL | 04/07/2026 | CANCELLED BY APPLICANT | JSTEWART |
| Note: 3/25/2026 - PREVIOUS INSPECTION NOTES 1. The 2 front corners of foundation and going down the sides have 12" +/- of foundation wall above finished grade, creating the possibility of bottom of footer is not the required 12" below finish grade (going off of Grade plan submitted and approved). Please repair. 2. install anti tip bracket. FBCR M1901.2 3. Install screens at roof exhaust terminations (Not the dryer). FBC R303.6 4. No Hot water in home. FBCR P2722.2 5. Please seal master tub at wall (large gap framing exposed). FBCR P2705.1 6. Master tub Missing overflow cover. FBCR P2705.1 – 4 | |||
| ROW - FINAL INSPECTION | 03/26/2026 | APPROVED | EMADISON |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| U -UTILITY RESIDENTIAL FINAL | 03/26/2026 | FINAL APPROVED | BWRIGHT |
| Note: Inspector Notes from Inspection 9035 No CC, IRR with reclaim | |||
| ROW - FINAL APRON (AFTER POUR) | 03/26/2026 | APPROVED | EMADISON |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| BLD - BUILDING FINAL | 03/25/2026 | Disapproved - NO FEE | JSTEWART |
| Note: 1. The 2 front corners of foundation and going down the sides have 12" +/- of foundation wall above finished grade, creating the possibility of bottom of footer is not the required 12" below finish grade (going off of Grade plan submitted and approved). Please repair. 2. install anti tip bracket. FBCR M1901.2 3. Install screens at roof exhaust terminations (Not the dryer). FBC R303.6 4. No Hot water in home. FBCR P2722.2 5. Please seal master tub at wall (large gap framing exposed). FBCR P2705.1 6. Master tub Missing overflow cover. FBCR P2705.1 – 4 | |||
| U-CROSS CONNECTION | 03/25/2026 | APPROVED - AS NOTED | BHAINES |
| Note: No CC, IRR with reclaim | |||
| ELECTRIC - EARLY POWER | 03/06/2026 | APPROVED | JSTEWART |
| Note: Inspector Notes from Inspection 2200 Authorize release of email | |||
| LATH/BRICK/ WATER BARRIER | 02/27/2026 | APPROVED | KSANDOE |
| Note: 2/10/2026 - PREVIOUS INSPECTION NOTES main building approved for siding, Lath for stone to complete. Inspector Notes from Inspection 2420 previous Notes not rectified...... 5. Romex sheathing required to enter holding box min of 1/4". to many to list check all interior walls and exterior walls). NEC 314.17(C) **7 Locations that need corrected, marked with orange paint on floor** Will need corrected prior to Insulation. 2/3/2026 - PREVIOUS INSPECTION NOTES 1. No water test Preassure. (gauge is broken replace). FBCR P2503.5 2. No 5ft head preassure test (empty) FBCR P2503.7 3. Hood duct requires 3 screws at seam connection. M1601.4.2 4. Front door Not installed (onsite). 5. Romex sheathing required to enter holding box min of 1/4". to many to list check all interior walls and exterior walls). NEC 314.17(C) 6. Spare bath exhaust duct is not connected to the fan assembly, required to exhaust to the exterior. M1501.1 / FBCR M1601.4.1 | |||
| ROW- PRE-APRON (PRE-POUR) | 02/26/2026 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. . TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, IN THE UPCOMING MONTHS THE DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS WILL BE REQUIRED TO BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. YOU WILL RECEIVE A NEWS BLAST WHEN THIS BECOMES NECESSARY. 2/25/2026 - PREVIOUS INSPECTION NOTES RECIEVED TEXT ASKING TO CANCEL INSPECTION @ 9:16 AM | |||
| ROW- PRE-APRON (PRE-POUR) | 02/25/2026 | CANCELLED BY APPLICANT | TPOLACEK |
| Note: RECIEVED TEXT ASKING TO CANCEL INSPECTION @ 9:16 AM | |||
| DRYWALL NAILING | 02/17/2026 | APPROVED | JSTEWART |
| INSULATION | 02/12/2026 | APPROVED | JSTEWART |
| Note: 2/11/2026 - PREVIOUS INSPECTION NOTES Previous Note not rectified......FBC EC R303.1.1.2.1 NEEDS ATTIC CARDS & MARKERS FOR BLOWN INSULATION 2/10/2026 - PREVIOUS INSPECTION NOTES FBC EC R303.1.1.2.1 NEEDS ATTIC CARDS & MARKERS FOR BLOWN INSULATION Inspector Notes from Inspection 2420 previous Notes not rectified...... 5. Romex sheathing required to enter holding box min of 1/4". to many to list check all interior walls and exterior walls). NEC 314.17(C) **7 Locations that need corrected, marked with orange paint on floor** Will need corrected prior to Insulation. 2/3/2026 - PREVIOUS INSPECTION NOTES 1. No water test Preassure. (gauge is broken replace). FBCR P2503.5 2. No 5ft head preassure test (empty) FBCR P2503.7 3. Hood duct requires 3 screws at seam connection. M1601.4.2 4. Front door Not installed (onsite). 5. Romex sheathing required to enter holding box min of 1/4". to many to list check all interior walls and exterior walls). NEC 314.17(C) 6. Spare bath exhaust duct is not connected to the fan assembly, required to exhaust to the exterior. M1501.1 / FBCR M1601.4.1 | |||
| INSULATION | 02/11/2026 | Disapproved -FEE REQUIRED | JSTEWART |
| Note: Previous Note not rectified......FBC EC R303.1.1.2.1 NEEDS ATTIC CARDS & MARKERS FOR BLOWN INSULATION 2/10/2026 - PREVIOUS INSPECTION NOTES FBC EC R303.1.1.2.1 NEEDS ATTIC CARDS & MARKERS FOR BLOWN INSULATION Inspector Notes from Inspection 2420 previous Notes not rectified...... 5. Romex sheathing required to enter holding box min of 1/4". to many to list check all interior walls and exterior walls). NEC 314.17(C) **7 Locations that need corrected, marked with orange paint on floor** Will need corrected prior to Insulation. 2/3/2026 - PREVIOUS INSPECTION NOTES 1. No water test Preassure. (gauge is broken replace). FBCR P2503.5 2. No 5ft head preassure test (empty) FBCR P2503.7 3. Hood duct requires 3 screws at seam connection. M1601.4.2 4. Front door Not installed (onsite). 5. Romex sheathing required to enter holding box min of 1/4". to many to list check all interior walls and exterior walls). NEC 314.17(C) 6. Spare bath exhaust duct is not connected to the fan assembly, required to exhaust to the exterior. M1501.1 / FBCR M1601.4.1 | |||
| LATH/BRICK/ WATER BARRIER | 02/10/2026 | PARTIALLY APPROVED | JSTEWART |
| Note: main building approved for siding, Lath for stone to complete. Inspector Notes from Inspection 2420 previous Notes not rectified...... 5. Romex sheathing required to enter holding box min of 1/4". to many to list check all interior walls and exterior walls). NEC 314.17(C) **7 Locations that need corrected, marked with orange paint on floor** Will need corrected prior to Insulation. 2/3/2026 - PREVIOUS INSPECTION NOTES 1. No water test Preassure. (gauge is broken replace). FBCR P2503.5 2. No 5ft head preassure test (empty) FBCR P2503.7 3. Hood duct requires 3 screws at seam connection. M1601.4.2 4. Front door Not installed (onsite). 5. Romex sheathing required to enter holding box min of 1/4". to many to list check all interior walls and exterior walls). NEC 314.17(C) 6. Spare bath exhaust duct is not connected to the fan assembly, required to exhaust to the exterior. M1501.1 / FBCR M1601.4.1 | |||
| INSULATION | 02/10/2026 | Disapproved - NO FEE | JSTEWART |
| Note: FBC EC R303.1.1.2.1 NEEDS ATTIC CARDS & MARKERS FOR BLOWN INSULATION Inspector Notes from Inspection 2420 previous Notes not rectified...... 5. Romex sheathing required to enter holding box min of 1/4". to many to list check all interior walls and exterior walls). NEC 314.17(C) **7 Locations that need corrected, marked with orange paint on floor** Will need corrected prior to Insulation. 2/3/2026 - PREVIOUS INSPECTION NOTES 1. No water test Preassure. (gauge is broken replace). FBCR P2503.5 2. No 5ft head preassure test (empty) FBCR P2503.7 3. Hood duct requires 3 screws at seam connection. M1601.4.2 4. Front door Not installed (onsite). 5. Romex sheathing required to enter holding box min of 1/4". to many to list check all interior walls and exterior walls). NEC 314.17(C) 6. Spare bath exhaust duct is not connected to the fan assembly, required to exhaust to the exterior. M1501.1 / FBCR M1601.4.1 | |||
| ELECTRIC-TUG | 02/10/2026 | APPROVED - AS NOTED | JSTEWART |
| Note: Authorize release of email | |||
| ALL ROUGH | 02/06/2026 | APPROVED - AS NOTED | JSTEWART |
| Note: previous Notes not rectified...... 5. Romex sheathing required to enter holding box min of 1/4". to many to list check all interior walls and exterior walls). NEC 314.17(C) **7 Locations that need corrected, marked with orange paint on floor** Will need corrected prior to Insulation. 2/3/2026 - PREVIOUS INSPECTION NOTES 1. No water test Preassure. (gauge is broken replace). FBCR P2503.5 2. No 5ft head preassure test (empty) FBCR P2503.7 3. Hood duct requires 3 screws at seam connection. M1601.4.2 4. Front door Not installed (onsite). 5. Romex sheathing required to enter holding box min of 1/4". to many to list check all interior walls and exterior walls). NEC 314.17(C) 6. Spare bath exhaust duct is not connected to the fan assembly, required to exhaust to the exterior. M1501.1 / FBCR M1601.4.1 | |||
| ALL ROUGH | 02/03/2026 | Disapproved - NO FEE | JSTEWART |
| Note: 1. No water test Preassure. (gauge is broken replace). FBCR P2503.5 2. No 5ft head preassure test (empty) FBCR P2503.7 3. Hood duct requires 3 screws at seam connection. M1601.4.2 4. Front door Not installed (onsite). 5. Romex sheathing required to enter holding box min of 1/4". to many to list check all interior walls and exterior walls). NEC 314.17(C) 6. Spare bath exhaust duct is not connected to the fan assembly, required to exhaust to the exterior. M1501.1 / FBCR M1601.4.1 | |||
| GRAVITY SEWER TEST | 02/03/2026 | APPROVED | JSTEWART |
| SEWER TIE IN | 02/03/2026 | APPROVED | JSTEWART |
| WALL SHEATHING | 01/29/2026 | APPROVED | JSTEWART |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 01/29/2026 | APPROVED | JSTEWART |
| ROOF VALLEY & METAL | 01/29/2026 | APPROVED | JSTEWART |
| WATER METER INSTALLATION REQUEST | 01/29/2026 | APPROVED | CBOWERMASTER |
| MONOLITHIC SLAB | 01/13/2026 | APPROVED | JSTEWART |
| FORMBOARD SURVEY (OFFICE USE ONLY) | 01/09/2026 | APPROVED | RRICKS |
| PLUMBING 1ST ROUGH UNDERGROUND | 01/09/2026 | APPROVED | JSTEWART |
Review History
| Department | Status | Date In | Date Out |
| ZON | COMPLETE | 01/08/2026 | 01/08/2026 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 01/08/2026 | 01/09/2026 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 01/07/2026 | 01/08/2026 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | HOLD | 01/07/2026 | 01/08/2026 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Setback in Left rear near patio not provided | |||
| BLD | COMPLETE | 12/15/2025 | 12/18/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 12/15/2025 | 12/19/2025 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 12/15/2025 | 12/16/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 12/15/2025 | 12/16/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| GAS | COMPLETE | 12/15/2025 | 12/16/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 12/15/2025 | 12/22/2025 |
| Note: Released By: TONI CHURCHILL - - TCHURCHILL@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 12/15/2025 | 12/16/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 12/15/2025 | 12/16/2025 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 12/15/2025 | 12/16/2025 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| URB | COMPLETE | 12/15/2025 | 12/18/2025 |
| Note: Released By: JOHN BEAUDET - (386)986-2456 - JBEAUDET@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 04/08/2026 |
| FC IMPACT FEE EMS | ¤62.00 | 12/23/2025 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 12/23/2025 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 12/23/2025 |
| FIRE RES IMPACT FEE 10-25 | ¤942.00 | 12/23/2025 |
| WATER METER W/OUT TAP | ¤965.03 | 12/23/2025 |
| PARKS IMPACT FEE 10-25 | ¤3,164.00 | 12/23/2025 |
| RECLAIM WATER PERMIT INSPECTIO | ¤40.00 | 12/23/2025 |
| RSI DRIVEWAY AFTER POUR | ¤16.25 | 12/23/2025 |
| RSE DRIVE PRE POUR INSPECTION | ¤32.50 | 12/23/2025 |
| RSI FIELD SURVEY INSPECTION | ¤48.75 | 12/23/2025 |
| RSI FORMBOARD REVIEW | ¤16.25 | 12/23/2025 |
| RSI PLAN REVIEW NEW | ¤48.75 | 12/23/2025 |
| RSI FNL SURVEY/GRADING CERT | ¤48.75 | 12/23/2025 |
| RSI ROW FINAL INSPECTION | ¤16.25 | 12/23/2025 |
| SCHOOL BOARD IMPACT FEE RES | ¤5,450.00 | 12/23/2025 |
| SURCHARGE FS 533.721 | ¤12.37 | 12/23/2025 |
| SURCHARGE - FS 468.631 | ¤18.56 | 12/23/2025 |
| TRANSP RES IMPACT FEE 10-25 | ¤6,435.39 | 12/23/2025 |
| WASTEWATER PERM INSPECTION | ¤80.00 | 12/23/2025 |
| WASTEWATER PERM REVIEW | ¤25.00 | 12/23/2025 |
| SEWER CAPITAL FACILITY | ¤3,737.90 | 12/23/2025 |
| WATER CAPITAL FACILITY FEE | ¤3,161.82 | 12/23/2025 |
| WATER PERMIT REVIEW | ¤25.00 | 12/23/2025 |
| SITE PLAN 30 | ¤30.00 | 12/23/2025 |
| WATER-METER | ¤874.47 | 12/23/2025 |
| WATER- TURN ON | ¤50.00 | 12/23/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 12/23/2025 |
| INSPECTION - RESIDENTIAL | ¤940.50 | 12/23/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤266.76 | 12/23/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤27,064.30 |