I want to search for...

Permit #2025120490

Permit Details

Status: COED

Parcel Id: 04-11-30-5570-00000-2430
CONDITIONED SPACE: 1707 sqft
GARAGE: 437 sqft
OPENED PORCH (WITH ROOF) : 64 sqft
OPENED PORCH (WITH ROOF) : 220 sqft
Total Square Footage: 2428 sqft
Subdivision: 2326 - SOMERSET SUBDIVISION PH 1
Job Phone: 904-596-6645
Location Address: 38 CAMELLIA ST
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 12/23/2025
NOC: RECORDED
Applicant name: MICHAEL T HOLDER
Owner: KB HOME JACKSONVILLE LLC

Address

10475 FORTUNE PARKWAY

JACKSONVILLE, FL 32256

Address

SUITE 100

JACKSONVILLE, FL 32256

Lot: 243
Contracted Stated Job Value: ¤140,000.00
Job Description: SINGLE FAMILY DWELLING
Type: CN

Contractor

KB HOME JACKSONVILLE, LLC
Status Location Address Mailing Address State License Number Phone
ACTIVE

10475 FORTUNE PKWY

JACKSONVILLE, FL 32256

SUITE 100

JACKSONVILLE, FL 32256

CGC1509034 (Exp: 08/31/2026) 904-596-6645

Sub Contractors

BOBBY WAYNE CAMPBELL
Status Location Address State License Number Phone
ACTIVE

117 GUTHRIE ROAD

GREEN COVE SPRINGS, FL 32043

CCC1326752 (Exp: 08/31/2026) 904-200-1600
JAMES E LINTON
Status Location Address State License Number Phone
ACTIVE

200 COLLEGE DR

ORANGE PARK, FL 32065

EC0001152 (Exp: 08/31/2026) 904-272-0272
LARRY WILLIAMS
Status Location Address State License Number Phone
ACTIVE

1750 EMERSON ST

JACKSONVILLE, FL 32207

LI45034 (Exp: 08/31/2026) 904-721-5431
COREY MICHAEL TENNANT
Status Location Address State License Number Phone
ACTIVE

3370 AGRICULTURAL CNETER DR

ST AUGUSTINE, FL 32092

CAC1819063 (Exp: 08/31/2026) 904-829-8898
BENJAMIN MICHAEL RAY
Status Location Address Mailing Address State License Number Phone Fax
ACTIVE

6310 MABLETON PKWY

JACKSONVILLE, FL 32216

SUITE 1000

MABLETON, GA 30126

CFC1428415 (Exp: 08/31/2026) 904-861-5421 904-861-5426

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 04/10/2026 FINAL APPROVED JSTEWART
Note: Note: Dirt was installed, and grade was raised to achieve the min 12" of footing below finish grade. 4/9/2026 - PREVIOUS INSPECTION NOTES Previous Note not rectified........ 1. The 2 front corners of foundation and going down the sides have 12" +/- of foundation wall above finished grade, creating the possibility of bottom of footer is not the required 12" below finish grade (going off of Grade plan submitted and approved). Please repair. NOTE: Builder removed dirt on right side of Home to reveal Bottom of footing, measurement was aproximatly 7"+/-. This does not meet FBC R403.1.4 for a min of 12" below grade. Findings have been sent to supervisor for further review. 4/7/2026 - PREVIOUS INSPECTION NOTES 3/25/2026 - PREVIOUS INSPECTION NOTES 1. The 2 front corners of foundation and going down the sides have 12" +/- of foundation wall above finished grade, creating the possibility of bottom of footer is not the required 12" below finish grade (going off of Grade plan submitted and approved). Please repair. 2. install anti tip bracket. FBCR M1901.2 3. Install screens at roof exhaust terminations (Not the dryer). FBC R303.6 4. No Hot water in home. FBCR P2722.2 5. Please seal master tub at wall (large gap framing exposed). FBCR P2705.1 6. Master tub Missing overflow cover. FBCR P2705.1 – 4
BLD - BUILDING FINAL 04/09/2026 Disapproved - NO FEE JSTEWART
Note: Previous Note not rectified........ 1. The 2 front corners of foundation and going down the sides have 12" +/- of foundation wall above finished grade, creating the possibility of bottom of footer is not the required 12" below finish grade (going off of Grade plan submitted and approved). Please repair. NOTE: Builder removed dirt on right side of Home to reveal Bottom of footing, measurement was aproximatly 7"+/-. This does not meet FBC R403.1.4 for a min of 12" below grade. Findings have been sent to supervisor for further review. 4/7/2026 - PREVIOUS INSPECTION NOTES 3/25/2026 - PREVIOUS INSPECTION NOTES 1. The 2 front corners of foundation and going down the sides have 12" +/- of foundation wall above finished grade, creating the possibility of bottom of footer is not the required 12" below finish grade (going off of Grade plan submitted and approved). Please repair. 2. install anti tip bracket. FBCR M1901.2 3. Install screens at roof exhaust terminations (Not the dryer). FBC R303.6 4. No Hot water in home. FBCR P2722.2 5. Please seal master tub at wall (large gap framing exposed). FBCR P2705.1 6. Master tub Missing overflow cover. FBCR P2705.1 – 4
ROW- FINAL SURVEY/GRADING CERTIFICATION 04/08/2026 APPROVED EMADISON
Note: ** Effective 03/25/26, the ROW Field Survey requirement is no longer in effect for Final Lot Grading and Drainage Certificates for new construction on subdivision and infill lots. All Final Lot Grading and Drainage Certificates for these projects will now be reviewed and approved only in the office. Field verification for the ROW-FIELD SURVEY will no longer be required as part of the standard approval process for these permit types. ** PER P. BUCKLEY CHIEF BUILDING Inspector. ** SCHEDULE YOUR FINALS WHEN YOU ARE READY TO DO SO
BLD - BUILDING FINAL 04/07/2026 CANCELLED BY APPLICANT JSTEWART
Note: 3/25/2026 - PREVIOUS INSPECTION NOTES 1. The 2 front corners of foundation and going down the sides have 12" +/- of foundation wall above finished grade, creating the possibility of bottom of footer is not the required 12" below finish grade (going off of Grade plan submitted and approved). Please repair. 2. install anti tip bracket. FBCR M1901.2 3. Install screens at roof exhaust terminations (Not the dryer). FBC R303.6 4. No Hot water in home. FBCR P2722.2 5. Please seal master tub at wall (large gap framing exposed). FBCR P2705.1 6. Master tub Missing overflow cover. FBCR P2705.1 – 4
ROW - FINAL INSPECTION 03/26/2026 APPROVED EMADISON
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
U -UTILITY RESIDENTIAL FINAL 03/26/2026 FINAL APPROVED BWRIGHT
Note: Inspector Notes from Inspection 9035 No CC, IRR with reclaim
ROW - FINAL APRON (AFTER POUR) 03/26/2026 APPROVED EMADISON
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
BLD - BUILDING FINAL 03/25/2026 Disapproved - NO FEE JSTEWART
Note: 1. The 2 front corners of foundation and going down the sides have 12" +/- of foundation wall above finished grade, creating the possibility of bottom of footer is not the required 12" below finish grade (going off of Grade plan submitted and approved). Please repair. 2. install anti tip bracket. FBCR M1901.2 3. Install screens at roof exhaust terminations (Not the dryer). FBC R303.6 4. No Hot water in home. FBCR P2722.2 5. Please seal master tub at wall (large gap framing exposed). FBCR P2705.1 6. Master tub Missing overflow cover. FBCR P2705.1 – 4
U-CROSS CONNECTION 03/25/2026 APPROVED - AS NOTED BHAINES
Note: No CC, IRR with reclaim
ELECTRIC - EARLY POWER 03/06/2026 APPROVED JSTEWART
Note: Inspector Notes from Inspection 2200 Authorize release of email
LATH/BRICK/ WATER BARRIER 02/27/2026 APPROVED KSANDOE
Note: 2/10/2026 - PREVIOUS INSPECTION NOTES main building approved for siding, Lath for stone to complete. Inspector Notes from Inspection 2420 previous Notes not rectified...... 5. Romex sheathing required to enter holding box min of 1/4". to many to list check all interior walls and exterior walls). NEC 314.17(C) **7 Locations that need corrected, marked with orange paint on floor** Will need corrected prior to Insulation. 2/3/2026 - PREVIOUS INSPECTION NOTES 1. No water test Preassure. (gauge is broken replace). FBCR P2503.5 2. No 5ft head preassure test (empty) FBCR P2503.7 3. Hood duct requires 3 screws at seam connection. M1601.4.2 4. Front door Not installed (onsite). 5. Romex sheathing required to enter holding box min of 1/4". to many to list check all interior walls and exterior walls). NEC 314.17(C) 6. Spare bath exhaust duct is not connected to the fan assembly, required to exhaust to the exterior. M1501.1 / FBCR M1601.4.1
ROW- PRE-APRON (PRE-POUR) 02/26/2026 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. . TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, IN THE UPCOMING MONTHS THE DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS WILL BE REQUIRED TO BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. YOU WILL RECEIVE A NEWS BLAST WHEN THIS BECOMES NECESSARY. 2/25/2026 - PREVIOUS INSPECTION NOTES RECIEVED TEXT ASKING TO CANCEL INSPECTION @ 9:16 AM
ROW- PRE-APRON (PRE-POUR) 02/25/2026 CANCELLED BY APPLICANT TPOLACEK
Note: RECIEVED TEXT ASKING TO CANCEL INSPECTION @ 9:16 AM
DRYWALL NAILING 02/17/2026 APPROVED JSTEWART
INSULATION 02/12/2026 APPROVED JSTEWART
Note: 2/11/2026 - PREVIOUS INSPECTION NOTES Previous Note not rectified......FBC EC R303.1.1.2.1 NEEDS ATTIC CARDS & MARKERS FOR BLOWN INSULATION 2/10/2026 - PREVIOUS INSPECTION NOTES FBC EC R303.1.1.2.1 NEEDS ATTIC CARDS & MARKERS FOR BLOWN INSULATION Inspector Notes from Inspection 2420 previous Notes not rectified...... 5. Romex sheathing required to enter holding box min of 1/4". to many to list check all interior walls and exterior walls). NEC 314.17(C) **7 Locations that need corrected, marked with orange paint on floor** Will need corrected prior to Insulation. 2/3/2026 - PREVIOUS INSPECTION NOTES 1. No water test Preassure. (gauge is broken replace). FBCR P2503.5 2. No 5ft head preassure test (empty) FBCR P2503.7 3. Hood duct requires 3 screws at seam connection. M1601.4.2 4. Front door Not installed (onsite). 5. Romex sheathing required to enter holding box min of 1/4". to many to list check all interior walls and exterior walls). NEC 314.17(C) 6. Spare bath exhaust duct is not connected to the fan assembly, required to exhaust to the exterior. M1501.1 / FBCR M1601.4.1
INSULATION 02/11/2026 Disapproved -FEE REQUIRED JSTEWART
Note: Previous Note not rectified......FBC EC R303.1.1.2.1 NEEDS ATTIC CARDS & MARKERS FOR BLOWN INSULATION 2/10/2026 - PREVIOUS INSPECTION NOTES FBC EC R303.1.1.2.1 NEEDS ATTIC CARDS & MARKERS FOR BLOWN INSULATION Inspector Notes from Inspection 2420 previous Notes not rectified...... 5. Romex sheathing required to enter holding box min of 1/4". to many to list check all interior walls and exterior walls). NEC 314.17(C) **7 Locations that need corrected, marked with orange paint on floor** Will need corrected prior to Insulation. 2/3/2026 - PREVIOUS INSPECTION NOTES 1. No water test Preassure. (gauge is broken replace). FBCR P2503.5 2. No 5ft head preassure test (empty) FBCR P2503.7 3. Hood duct requires 3 screws at seam connection. M1601.4.2 4. Front door Not installed (onsite). 5. Romex sheathing required to enter holding box min of 1/4". to many to list check all interior walls and exterior walls). NEC 314.17(C) 6. Spare bath exhaust duct is not connected to the fan assembly, required to exhaust to the exterior. M1501.1 / FBCR M1601.4.1
LATH/BRICK/ WATER BARRIER 02/10/2026 PARTIALLY APPROVED JSTEWART
Note: main building approved for siding, Lath for stone to complete. Inspector Notes from Inspection 2420 previous Notes not rectified...... 5. Romex sheathing required to enter holding box min of 1/4". to many to list check all interior walls and exterior walls). NEC 314.17(C) **7 Locations that need corrected, marked with orange paint on floor** Will need corrected prior to Insulation. 2/3/2026 - PREVIOUS INSPECTION NOTES 1. No water test Preassure. (gauge is broken replace). FBCR P2503.5 2. No 5ft head preassure test (empty) FBCR P2503.7 3. Hood duct requires 3 screws at seam connection. M1601.4.2 4. Front door Not installed (onsite). 5. Romex sheathing required to enter holding box min of 1/4". to many to list check all interior walls and exterior walls). NEC 314.17(C) 6. Spare bath exhaust duct is not connected to the fan assembly, required to exhaust to the exterior. M1501.1 / FBCR M1601.4.1
INSULATION 02/10/2026 Disapproved - NO FEE JSTEWART
Note: FBC EC R303.1.1.2.1 NEEDS ATTIC CARDS & MARKERS FOR BLOWN INSULATION Inspector Notes from Inspection 2420 previous Notes not rectified...... 5. Romex sheathing required to enter holding box min of 1/4". to many to list check all interior walls and exterior walls). NEC 314.17(C) **7 Locations that need corrected, marked with orange paint on floor** Will need corrected prior to Insulation. 2/3/2026 - PREVIOUS INSPECTION NOTES 1. No water test Preassure. (gauge is broken replace). FBCR P2503.5 2. No 5ft head preassure test (empty) FBCR P2503.7 3. Hood duct requires 3 screws at seam connection. M1601.4.2 4. Front door Not installed (onsite). 5. Romex sheathing required to enter holding box min of 1/4". to many to list check all interior walls and exterior walls). NEC 314.17(C) 6. Spare bath exhaust duct is not connected to the fan assembly, required to exhaust to the exterior. M1501.1 / FBCR M1601.4.1
ELECTRIC-TUG 02/10/2026 APPROVED - AS NOTED JSTEWART
Note: Authorize release of email
ALL ROUGH 02/06/2026 APPROVED - AS NOTED JSTEWART
Note: previous Notes not rectified...... 5. Romex sheathing required to enter holding box min of 1/4". to many to list check all interior walls and exterior walls). NEC 314.17(C) **7 Locations that need corrected, marked with orange paint on floor** Will need corrected prior to Insulation. 2/3/2026 - PREVIOUS INSPECTION NOTES 1. No water test Preassure. (gauge is broken replace). FBCR P2503.5 2. No 5ft head preassure test (empty) FBCR P2503.7 3. Hood duct requires 3 screws at seam connection. M1601.4.2 4. Front door Not installed (onsite). 5. Romex sheathing required to enter holding box min of 1/4". to many to list check all interior walls and exterior walls). NEC 314.17(C) 6. Spare bath exhaust duct is not connected to the fan assembly, required to exhaust to the exterior. M1501.1 / FBCR M1601.4.1
ALL ROUGH 02/03/2026 Disapproved - NO FEE JSTEWART
Note: 1. No water test Preassure. (gauge is broken replace). FBCR P2503.5 2. No 5ft head preassure test (empty) FBCR P2503.7 3. Hood duct requires 3 screws at seam connection. M1601.4.2 4. Front door Not installed (onsite). 5. Romex sheathing required to enter holding box min of 1/4". to many to list check all interior walls and exterior walls). NEC 314.17(C) 6. Spare bath exhaust duct is not connected to the fan assembly, required to exhaust to the exterior. M1501.1 / FBCR M1601.4.1
GRAVITY SEWER TEST 02/03/2026 APPROVED JSTEWART
SEWER TIE IN 02/03/2026 APPROVED JSTEWART
WALL SHEATHING 01/29/2026 APPROVED JSTEWART
ROOF SHEATHING / BRACES/TIES/DOWN CELL 01/29/2026 APPROVED JSTEWART
ROOF VALLEY & METAL 01/29/2026 APPROVED JSTEWART
WATER METER INSTALLATION REQUEST 01/29/2026 APPROVED CBOWERMASTER
MONOLITHIC SLAB 01/13/2026 APPROVED JSTEWART
FORMBOARD SURVEY (OFFICE USE ONLY) 01/09/2026 APPROVED RRICKS
PLUMBING 1ST ROUGH UNDERGROUND 01/09/2026 APPROVED JSTEWART

Review History

Department Status Date In Date Out
ZON COMPLETE 01/08/2026 01/08/2026
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
SW1 COMPLETE 01/08/2026 01/09/2026
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
SW1 COMPLETE 01/07/2026 01/08/2026
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON HOLD 01/07/2026 01/08/2026
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Setback in Left rear near patio not provided
BLD COMPLETE 12/15/2025 12/18/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
CUSVC COMPLETE 12/15/2025 12/19/2025
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 12/15/2025 12/16/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 12/15/2025 12/16/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS COMPLETE 12/15/2025 12/16/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
LOCATE COMPLETE 12/15/2025 12/22/2025
Note: Released By: TONI CHURCHILL - - TCHURCHILL@PALMCOASTGOV.COM
MECH COMPLETE 12/15/2025 12/16/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 12/15/2025 12/16/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 12/15/2025 12/16/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
URB COMPLETE 12/15/2025 12/18/2025
Note: Released By: JOHN BEAUDET - (386)986-2456 - JBEAUDET@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 04/08/2026
FC IMPACT FEE EMS ¤62.00 12/23/2025
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 12/23/2025
FC IMPACT FEE LIBRARY ¤268.00 12/23/2025
FIRE RES IMPACT FEE 10-25 ¤942.00 12/23/2025
WATER METER W/OUT TAP ¤965.03 12/23/2025
PARKS IMPACT FEE 10-25 ¤3,164.00 12/23/2025
RECLAIM WATER PERMIT INSPECTIO ¤40.00 12/23/2025
RSI DRIVEWAY AFTER POUR ¤16.25 12/23/2025
RSE DRIVE PRE POUR INSPECTION ¤32.50 12/23/2025
RSI FIELD SURVEY INSPECTION ¤48.75 12/23/2025
RSI FORMBOARD REVIEW ¤16.25 12/23/2025
RSI PLAN REVIEW NEW ¤48.75 12/23/2025
RSI FNL SURVEY/GRADING CERT ¤48.75 12/23/2025
RSI ROW FINAL INSPECTION ¤16.25 12/23/2025
SCHOOL BOARD IMPACT FEE RES ¤5,450.00 12/23/2025
SURCHARGE FS 533.721 ¤12.37 12/23/2025
SURCHARGE - FS 468.631 ¤18.56 12/23/2025
TRANSP RES IMPACT FEE 10-25 ¤6,435.39 12/23/2025
WASTEWATER PERM INSPECTION ¤80.00 12/23/2025
WASTEWATER PERM REVIEW ¤25.00 12/23/2025
SEWER CAPITAL FACILITY ¤3,737.90 12/23/2025
WATER CAPITAL FACILITY FEE ¤3,161.82 12/23/2025
WATER PERMIT REVIEW ¤25.00 12/23/2025
SITE PLAN 30 ¤30.00 12/23/2025
WATER-METER ¤874.47 12/23/2025
WATER- TURN ON ¤50.00 12/23/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 12/23/2025
INSPECTION - RESIDENTIAL ¤940.50 12/23/2025
PLAN REVIEW - RESIDENTIAL ¤266.76 12/23/2025
Fees Total Due: ¤0.00 Total Paid: ¤27,064.30