I want to search for...

Permit #2025120619

Permit Details

Status: INSPECT

Parcel Id: 07-11-31-7030-00300-0270
GARAGE: 508 sqft
OPENED PORCH (WITH ROOF) : 259 sqft
CONDITIONED SPACE: 2332 sqft
Total Square Footage: 3099 sqft
Block: 00300
Subdivision: 2154 - SECTION 30-ROYAL PALMS
Job Phone: 352-433-8382
Location Address: 38 RADFORD LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 01/08/2026
NOC: RECORDED
Applicant name: ALFREDO E SCHEER
Owner: PIERCE WILLIAM E & ANNETTE MARIE

Address

42 ST ANDREWS COURT

PALM COAST, FL 32137

Lot: 0270
Contracted Stated Job Value: ¤165,000.00
Job Description: Single Family
Type: CN

Contractor

ESTELA LIVING LLC
Status Location Address State License Number Phone
ACTIVE

237 S. DIXIE HWY, 4TH FLOOR

CORAL GABLES, FL 33133

CGC1534535 (Exp: 08/31/2026) 352-433-8382

Sub Contractors

DUSTIN L ESTEP
Status Location Address State License Number Phone Fax
ACTIVE

2041 N HIAWASSEE RD

APOPKA, FL 32703

CCC1330971 (Exp: 08/31/2026) 407-702-0206 352-988-6629
JUAN CARLOS GONZALEZ
Status Location Address State License Number
ACTIVE

1328 COUNTY ROAD 308

CRESCENT CITY, FL 32112

RF11067806 (Exp: 08/31/2027)
JOSEPH H STRADA JR
Status Location Address State License Number Phone
ACTIVE

3400 ST JOHNS PKWY

SANFORD, FL 32771

CAC043953 (Exp: 08/31/2026) 877-906-1113
JOSEPH HORATIO STRADA JR
Status Location Address State License Number Phone
ACTIVE

3400 ST JOHNS PARKWAY

SANFORD, FL 32771

EC13003715 (Exp: 08/31/2026) 877-906-1113

Inspection History

Type Request Date Result Inspector
ROW- PRE-APRON (PRE-POUR) 06/04/2026 APPROVED FSLADISH
Note: 6/4/26 PIPE INVERT IS GOOD AT TIME OF THIS INSPECTION. BUILDER REFER TO CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED. DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR BEFORE POURING. . IF FIBERGLASS OPTION IS USED, BUILDER REQUIRED TO USE 3000 PSI CONCRETE AT THE TIME OF THE INSPECTION READY TO POUR, IF RAIN, BUILDER SHOULD DOUBLE CHECK SITE FOR ANY STANDING WATER AND VERIFY PIPE ELEVATION HAS NOT CHANGED. NO EXPANSION JOINTS ALLOWED, AT THE TIME OF THIS INSPECTION ALL MINIMUM COPC REQUIREMENTS ARE MET. BUILDER TO BE HELD RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR.
SEWER TIE IN 05/29/2026 APPROVED CVANSTRAHLEN
Note: 5/28/2026 - PREVIOUS INSPECTION NOTES Please fix item before next inspection #1- Utilities like the City of Palm Coast Utility Department mandate that a cleanout be placed within 3 feet from the end of the PEP tank to provide a concrete reference point for elevation and maintenance. ( connection not visible ) Inspector Notes from Inspection 2060 FBC 3303.5-SWALE CLEAR 2/18/2026 - PREVIOUS INSPECTION NOTES Please fis items before next inspection #1-Please seperate Hot water and cold water in trench (clear path) min 6" for thermal transfer per Uponer manufacturer spec. 308.9 Parallel water distribution systems. Please sleeve all water supply lines that cross plumbing. FBCP 305.2 Stress and strain #2-FBCR P2503.5-NEEDS 5 FOOT HEAD TEST ON DWV ( not water on pipe , fill with water to top ) #3-Missing a pressure gauge
GRAVITY SEWER TEST 05/28/2026 APPROVED CVANSTRAHLEN
Note: Inspector Notes from Inspection 2060 FBC 3303.5-SWALE CLEAR 2/18/2026 - PREVIOUS INSPECTION NOTES Please fis items before next inspection #1-Please seperate Hot water and cold water in trench (clear path) min 6" for thermal transfer per Uponer manufacturer spec. 308.9 Parallel water distribution systems. Please sleeve all water supply lines that cross plumbing. FBCP 305.2 Stress and strain #2-FBCR P2503.5-NEEDS 5 FOOT HEAD TEST ON DWV ( not water on pipe , fill with water to top ) #3-Missing a pressure gauge
SEWER TIE IN 05/28/2026 Disapproved - NO FEE CVANSTRAHLEN
Note: Please fix item before next inspection #1- Utilities like the City of Palm Coast Utility Department mandate that a cleanout be placed within 3 feet from the end of the PEP tank to provide a concrete reference point for elevation and maintenance. ( connection not visible ) Inspector Notes from Inspection 2060 FBC 3303.5-SWALE CLEAR 2/18/2026 - PREVIOUS INSPECTION NOTES Please fis items before next inspection #1-Please seperate Hot water and cold water in trench (clear path) min 6" for thermal transfer per Uponer manufacturer spec. 308.9 Parallel water distribution systems. Please sleeve all water supply lines that cross plumbing. FBCP 305.2 Stress and strain #2-FBCR P2503.5-NEEDS 5 FOOT HEAD TEST ON DWV ( not water on pipe , fill with water to top ) #3-Missing a pressure gauge
ELECTRIC - EARLY POWER 05/27/2026 APPROVED CVANSTRAHLEN
Note: 5/15/2026 - PREVIOUS INSPECTION NOTES Please fix item before next inspection #1-NEC 250.24(A)(1) & 250.52(A)(3)-GROUNDING OF SERVICE - NEC-a ground rod or a complete grounding electrode system is required by the Florida Building Code and NEC Article 250 to obtain permanent or temporary power approval. For new construction, a concrete-encased electrode
ELECTRIC - EARLY POWER 05/15/2026 Disapproved - NO FEE CVANSTRAHLEN
Note: Please fix item before next inspection #1-NEC 250.24(A)(1) & 250.52(A)(3)-GROUNDING OF SERVICE - NEC-a ground rod or a complete grounding electrode system is required by the Florida Building Code and NEC Article 250 to obtain permanent or temporary power approval. For new construction, a concrete-encased electrode
PEP TANK INSTALLATION REQUEST 05/06/2026 APPROVED ISANDERSON
DRYWALL NAILING 04/21/2026 APPROVED CVANSTRAHLEN
DRYWALL NAILING 04/17/2026 CANCELLED BY APPLICANT WEB
LATH/BRICK/ WATER BARRIER 04/17/2026 APPROVED CVANSTRAHLEN
INSULATION 04/10/2026 APPROVED HCAMACHO
Note: New inspection due to canceled inspection 4/8/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1-Missing Fire rate foam where mark is with red sharpie market Items #1 #2 #3 from previous inspection not fix Item #1 can be inspected at final Inspector Notes from Inspection 2420 *** NOTES ADDED BY CVANSTRAHLEN 4/6/2026 2:21:49 PM *** please fix #2-FBCR P2605.1-PIPE SUPPORT PEX 32" HORIZONTAL 10 FOOT VERTICAL CPVC UP TO 1" - 3 FEET HORIZONTAL, 10 FEET VERTICAL CPVC 1 1/4" AND UP - 4 FEET HORIZONTAL, 10 FEET VERTICAL PVC 4 FOOT HORIZONTAL, 10 FEET VERTICAL #3-FBCR P2503.7-NEEDS WATER TEST ON DWV - 5 FT HEAD PRESSURE ABOVE HIGHEST FIXTURE - FILL TUB TO OVERFLOW Please fix items before next inspection #1-Missing Fl Approval number for windows and slidding door on Fl Approval sheet
INSULATION 04/09/2026 CANCELLED BY APPLICANT WEB
Note: 4/8/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1-Missing Fire rate foam where mark is with red sharpie market Items #1 #2 #3 from previous inspection not fix Item #1 can be inspected at final Inspector Notes from Inspection 2420 *** NOTES ADDED BY CVANSTRAHLEN 4/6/2026 2:21:49 PM *** please fix #2-FBCR P2605.1-PIPE SUPPORT PEX 32" HORIZONTAL 10 FOOT VERTICAL CPVC UP TO 1" - 3 FEET HORIZONTAL, 10 FEET VERTICAL CPVC 1 1/4" AND UP - 4 FEET HORIZONTAL, 10 FEET VERTICAL PVC 4 FOOT HORIZONTAL, 10 FEET VERTICAL #3-FBCR P2503.7-NEEDS WATER TEST ON DWV - 5 FT HEAD PRESSURE ABOVE HIGHEST FIXTURE - FILL TUB TO OVERFLOW Please fix items before next inspection #1-Missing Fl Approval number for windows and slidding door on Fl Approval sheet
INSULATION 04/08/2026 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: Please fix items before next inspection #1-Missing Fire rate foam where mark is with red sharpie market Items #1 #2 #3 from previous inspection not fix Item #1 can be inspected at final Inspector Notes from Inspection 2420 *** NOTES ADDED BY CVANSTRAHLEN 4/6/2026 2:21:49 PM *** please fix #2-FBCR P2605.1-PIPE SUPPORT PEX 32" HORIZONTAL 10 FOOT VERTICAL CPVC UP TO 1" - 3 FEET HORIZONTAL, 10 FEET VERTICAL CPVC 1 1/4" AND UP - 4 FEET HORIZONTAL, 10 FEET VERTICAL PVC 4 FOOT HORIZONTAL, 10 FEET VERTICAL #3-FBCR P2503.7-NEEDS WATER TEST ON DWV - 5 FT HEAD PRESSURE ABOVE HIGHEST FIXTURE - FILL TUB TO OVERFLOW Please fix items before next inspection #1-Missing Fl Approval number for windows and slidding door on Fl Approval sheet
ALL ROUGH 04/06/2026 APPROVED - AS NOTED CVANSTRAHLEN
Note: *** NOTES ADDED BY CVANSTRAHLEN 4/6/2026 2:21:49 PM *** please fix #2-FBCR P2605.1-PIPE SUPPORT PEX 32" HORIZONTAL 10 FOOT VERTICAL CPVC UP TO 1" - 3 FEET HORIZONTAL, 10 FEET VERTICAL CPVC 1 1/4" AND UP - 4 FEET HORIZONTAL, 10 FEET VERTICAL PVC 4 FOOT HORIZONTAL, 10 FEET VERTICAL #3-FBCR P2503.7-NEEDS WATER TEST ON DWV - 5 FT HEAD PRESSURE ABOVE HIGHEST FIXTURE - FILL TUB TO OVERFLOW Please fix items before next inspection #1-Missing Fl Approval number for windows and slidding door on Fl Approval sheet
ROOF SHEATHING / BRACES/TIES/DOWN CELL 04/02/2026 APPROVED CVANSTRAHLEN
Note: 3/27/2026 - PREVIOUS INSPECTION NOTES 3/26/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection Item #1 and #2 need to be fix before next inspection . thank you 3/23/2026 - PREVIOUS INSPECTION NOTES cancelled by phone call 3/19/2026 - PREVIOUS INSPECTION NOTES 1. Part of the bearing wall in garage calls for 2x6 and 2x4 is installed including the post. Page S-5 marked 2. Bearing wall in garage is missing screws see note on page S-5. marked 3. Bearing wall in bedroom is missing screws and anchor bolts. see page S-5 and Detail B SD-3a. marked
WALL SHEATHING 03/31/2026 APPROVED CVANSTRAHLEN
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/27/2026 CANCELLED BY APPLICANT CVANSTRAHLEN
Note: 3/26/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection Item #1 and #2 need to be fix before next inspection . thank you 3/23/2026 - PREVIOUS INSPECTION NOTES cancelled by phone call 3/19/2026 - PREVIOUS INSPECTION NOTES 1. Part of the bearing wall in garage calls for 2x6 and 2x4 is installed including the post. Page S-5 marked 2. Bearing wall in garage is missing screws see note on page S-5. marked 3. Bearing wall in bedroom is missing screws and anchor bolts. see page S-5 and Detail B SD-3a. marked
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/26/2026 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: Please fix items before next inspection Item #1 and #2 need to be fix before next inspection . thank you 3/23/2026 - PREVIOUS INSPECTION NOTES cancelled by phone call 3/19/2026 - PREVIOUS INSPECTION NOTES 1. Part of the bearing wall in garage calls for 2x6 and 2x4 is installed including the post. Page S-5 marked 2. Bearing wall in garage is missing screws see note on page S-5. marked 3. Bearing wall in bedroom is missing screws and anchor bolts. see page S-5 and Detail B SD-3a. marked
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/23/2026 CANCELLED BY APPLICANT CVANSTRAHLEN
Note: cancelled by phone call 3/19/2026 - PREVIOUS INSPECTION NOTES 1. Part of the bearing wall in garage calls for 2x6 and 2x4 is installed including the post. Page S-5 marked 2. Bearing wall in garage is missing screws see note on page S-5. marked 3. Bearing wall in bedroom is missing screws and anchor bolts. see page S-5 and Detail B SD-3a. marked
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/19/2026 Disapproved - NO FEE HCAMACHO
Note: 1. Part of the bearing wall in garage calls for 2x6 and 2x4 is installed including the post. Page S-5 marked 2. Bearing wall in garage is missing screws see note on page S-5. marked 3. Bearing wall in bedroom is missing screws and anchor bolts. see page S-5 and Detail B SD-3a. marked
ROOF VALLEY & METAL 03/19/2026 APPROVED HCAMACHO
BLD - BUILDING FINAL 03/19/2026 CANCELLED BY APPLICANT WEB
Note: Inspector Notes from Inspection 2465 *** NOTES ADDED BY RSIMS 3/17/2026 2:23:54 PM *** 3/17/26: Approved to dry in. Previously noted deficiency will still need to be resolved by Inspection 2460. Inspector Notes from Inspection 2340 Please fix item before next inspectionn #1-right side wall have 30' 1-1/2" is hanging out of slab , please have engineering fix , summit for revision and approval
ROOF SHEATHING 03/17/2026 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 3/17/2026 2:23:54 PM *** 3/17/26: Approved to dry in. Previously noted deficiency will still need to be resolved by Inspection 2460. Inspector Notes from Inspection 2340 Please fix item before next inspectionn #1-right side wall have 30' 1-1/2" is hanging out of slab , please have engineering fix , summit for revision and approval
TIE BEAM / LINTEL 03/09/2026 APPROVED - AS NOTED CVANSTRAHLEN
Note: Please fix item before next inspectionn #1-right side wall have 30' 1-1/2" is hanging out of slab , please have engineering fix , summit for revision and approval
MONOLITHIC SLAB 02/27/2026 APPROVED BTAYLOR
Note: 2/25/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1-FBCR 318-MISSING UFER GROUND - CONCRETE ENCASED ELECTRODE ARE ( not tie to rebars ) #2-FBC R318.6.2 -REMOVE ALL VEGETATION , DEBRIS OF MATERIAL #3-FBCRP2603.4-SLEEVE PLUMBING OR PROVIDE A RELIEVING ARCH THROUGH FOUNDATION WALL ( BY MAIN DRAIN LINE BEHING GARAGE WALL BATHROOM , AND FOTTING BY LEAVING ROOM AREA )
MONOLITHIC SLAB 02/25/2026 Disapproved - NO FEE CVANSTRAHLEN
Note: Please fix items before next inspection #1-FBCR 318-MISSING UFER GROUND - CONCRETE ENCASED ELECTRODE ARE ( not tie to rebars ) #2-FBC R318.6.2 -REMOVE ALL VEGETATION , DEBRIS OF MATERIAL #3-FBCRP2603.4-SLEEVE PLUMBING OR PROVIDE A RELIEVING ARCH THROUGH FOUNDATION WALL ( BY MAIN DRAIN LINE BEHING GARAGE WALL BATHROOM , AND FOTTING BY LEAVING ROOM AREA )
PLUMBING 1ST ROUGH UNDERGROUND 02/20/2026 APPROVED - AS NOTED CVANSTRAHLEN
Note: FBC 3303.5-SWALE CLEAR 2/18/2026 - PREVIOUS INSPECTION NOTES Please fis items before next inspection #1-Please seperate Hot water and cold water in trench (clear path) min 6" for thermal transfer per Uponer manufacturer spec. 308.9 Parallel water distribution systems. Please sleeve all water supply lines that cross plumbing. FBCP 305.2 Stress and strain #2-FBCR P2503.5-NEEDS 5 FOOT HEAD TEST ON DWV ( not water on pipe , fill with water to top ) #3-Missing a pressure gauge
PLUMBING 1ST ROUGH UNDERGROUND 02/18/2026 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: Please fis items before next inspection #1-Please seperate Hot water and cold water in trench (clear path) min 6" for thermal transfer per Uponer manufacturer spec. 308.9 Parallel water distribution systems. Please sleeve all water supply lines that cross plumbing. FBCP 305.2 Stress and strain #2-FBCR P2503.5-NEEDS 5 FOOT HEAD TEST ON DWV ( not water on pipe , fill with water to top ) #3-Missing a pressure gauge
FORMBOARD SURVEY (OFFICE USE ONLY) 02/17/2026 APPROVED RRICKS
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 02/10/2026 APPROVED PKNAPIK
WATER METER INSTALLATION REQUEST 01/20/2026 APPROVED CBOWERMASTER
BLD - BUILDING FINAL
Note: New inspection due to canceled inspection Inspector Notes from Inspection 2465 *** NOTES ADDED BY RSIMS 3/17/2026 2:23:54 PM *** 3/17/26: Approved to dry in. Previously noted deficiency will still need to be resolved by Inspection 2460. Inspector Notes from Inspection 2340 Please fix item before next inspectionn #1-right side wall have 30' 1-1/2" is hanging out of slab , please have engineering fix , summit for revision and approval
ROW - FINAL APRON (AFTER POUR)
ROW - FINAL INSPECTION
U -UTILITY RESIDENTIAL FINAL
U-CROSS CONNECTION

Review History

Department Status Date In Date Out
BLD COMPLETE 03/13/2026 03/18/2026
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
SW1 COMPLETE 02/17/2026 02/17/2026
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 02/17/2026 02/17/2026
Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM
BLD COMPLETE 02/10/2026 02/10/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD COMPLETE 01/29/2026 01/30/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
ZON COMPLETE 12/26/2025 12/26/2025
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
ENGIN1 COMPLETE 12/26/2025 12/29/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
SW1 CANCEL 12/26/2025 12/31/2025
SWALE COMPLETE 12/19/2025 01/06/2026
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
BLD COMPLETE 12/18/2025 12/26/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
CUSVC COMPLETE 12/18/2025 12/23/2025
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 12/18/2025 12/26/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 12/18/2025 12/19/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS CANCEL 12/18/2025 12/18/2025
LOCATE COMPLETE 12/18/2025 12/23/2025
Note: Released By: TONI CHURCHILL - - TCHURCHILL@PALMCOASTGOV.COM
MECH COMPLETE 12/18/2025 12/19/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 12/18/2025 12/22/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON HOLD 12/18/2025 12/18/2025
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM te site plan does not match any of the plans you have the wrong house on there

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
FC IMPACT FEE EMS ¤62.00 01/08/2026
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 01/08/2026
FC IMPACT FEE LIBRARY ¤268.00 01/08/2026
FIRE RES IMPACT FEE 10-25 ¤942.00 01/08/2026
PEP TANK INSTALL ¤756.74 01/08/2026
PARKS IMPACT FEE 10-25 ¤3,164.00 01/08/2026
RSI DRIVEWAY AFTER POUR ¤16.25 01/08/2026
RSE DRIVE PRE POUR INSPECTION ¤32.50 01/08/2026
RSI FIELD SURVEY INSPECTION ¤48.75 01/08/2026
RSI FORMBOARD REVIEW ¤16.25 01/08/2026
RSI PLAN REVIEW NEW ¤48.75 01/08/2026
RSI FNL SURVEY/GRADING CERT ¤48.75 01/08/2026
RSI ROW FINAL INSPECTION ¤16.25 01/08/2026
SCHOOL BOARD IMPACT FEE RES ¤5,450.00 01/08/2026
WASTEWATER MAIN EXTENSION IMPA ¤2,385.00 01/08/2026
SURCHARGE FS 533.721 ¤16.26 01/08/2026
SURCHARGE - FS 468.631 ¤24.38 01/08/2026
SW ENG RES REVIEW 240 ¤240.00 01/08/2026
WATER METER W/ TAP ¤2,326.93 01/08/2026
TRANSP RES IMPACT FEE 10-25 ¤8,791.64 01/08/2026
SEWER CREDIT (¤1,147.00) 01/08/2026
WASTEWATER PERM INSPECTION ¤80.00 01/08/2026
WASTEWATER PERM REVIEW ¤25.00 01/08/2026
SEWER CAPITAL FACILITY ¤4,415.00 01/08/2026
WATER CAPITAL FACILITY FEE ¤3,790.49 01/08/2026
WATER PERMIT REVIEW ¤25.00 01/08/2026
WATER MAIN EXTENSION IMPACT ¤917.27 01/08/2026
SITE PLAN 30 ¤30.00 01/08/2026
WATER- TURN ON ¤50.00 01/08/2026
ADMINISTRATIVE RESIDENTIAL ¤30.00 01/08/2026
INSPECTION - RESIDENTIAL ¤1,243.00 01/08/2026
PLAN REVIEW - RESIDENTIAL ¤352.56 01/08/2026
REINSPECTION RESIDENTIAL ¤40.00
REINSPECTION RESIDENTIAL ¤40.00
REINSPECTION RESIDENTIAL ¤40.00
Fees Total Due: ¤120.00 Total Paid: ¤34,683.77