I want to search for...
Permit #2025120619
Permit Details
Status: INSPECT
| Parcel Id: 07-11-31-7030-00300-0270 |
| GARAGE: 508 sqft |
| OPENED PORCH (WITH ROOF) : 259 sqft |
| CONDITIONED SPACE: 2332 sqft |
| Total Square Footage: 3099 sqft |
| Block: 00300 |
| Subdivision: 2154 - SECTION 30-ROYAL PALMS |
| Job Phone: 352-433-8382 |
| Location Address: 38 RADFORD LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 01/08/2026 |
| NOC: RECORDED |
| Applicant name: ALFREDO E SCHEER |
| Owner: PIERCE WILLIAM E & ANNETTE MARIE |
|
Address 42 ST ANDREWS COURT PALM COAST, FL 32137 |
| Lot: 0270 |
| Contracted Stated Job Value: ¤165,000.00 |
| Job Description: Single Family |
| Type: CN |
Contractor
ESTELA LIVING LLC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
237 S. DIXIE HWY, 4TH FLOOR CORAL GABLES, FL 33133 |
CGC1534535 (Exp: 08/31/2026) | 352-433-8382 |
Sub Contractors
DUSTIN L ESTEP
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2041 N HIAWASSEE RD APOPKA, FL 32703 |
CCC1330971 (Exp: 08/31/2026) | 407-702-0206 | 352-988-6629 |
JUAN CARLOS GONZALEZ
| Status | Location Address | State License Number |
| ACTIVE |
1328 COUNTY ROAD 308 CRESCENT CITY, FL 32112 |
RF11067806 (Exp: 08/31/2027) |
JOSEPH H STRADA JR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3400 ST JOHNS PKWY SANFORD, FL 32771 |
CAC043953 (Exp: 08/31/2026) | 877-906-1113 |
JOSEPH HORATIO STRADA JR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3400 ST JOHNS PARKWAY SANFORD, FL 32771 |
EC13003715 (Exp: 08/31/2026) | 877-906-1113 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROW- PRE-APRON (PRE-POUR) | 06/04/2026 | APPROVED | FSLADISH |
| Note: 6/4/26 PIPE INVERT IS GOOD AT TIME OF THIS INSPECTION. BUILDER REFER TO CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED. DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR BEFORE POURING. . IF FIBERGLASS OPTION IS USED, BUILDER REQUIRED TO USE 3000 PSI CONCRETE AT THE TIME OF THE INSPECTION READY TO POUR, IF RAIN, BUILDER SHOULD DOUBLE CHECK SITE FOR ANY STANDING WATER AND VERIFY PIPE ELEVATION HAS NOT CHANGED. NO EXPANSION JOINTS ALLOWED, AT THE TIME OF THIS INSPECTION ALL MINIMUM COPC REQUIREMENTS ARE MET. BUILDER TO BE HELD RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR. | |||
| SEWER TIE IN | 05/29/2026 | APPROVED | CVANSTRAHLEN |
| Note: 5/28/2026 - PREVIOUS INSPECTION NOTES Please fix item before next inspection #1- Utilities like the City of Palm Coast Utility Department mandate that a cleanout be placed within 3 feet from the end of the PEP tank to provide a concrete reference point for elevation and maintenance. ( connection not visible ) Inspector Notes from Inspection 2060 FBC 3303.5-SWALE CLEAR 2/18/2026 - PREVIOUS INSPECTION NOTES Please fis items before next inspection #1-Please seperate Hot water and cold water in trench (clear path) min 6" for thermal transfer per Uponer manufacturer spec. 308.9 Parallel water distribution systems. Please sleeve all water supply lines that cross plumbing. FBCP 305.2 Stress and strain #2-FBCR P2503.5-NEEDS 5 FOOT HEAD TEST ON DWV ( not water on pipe , fill with water to top ) #3-Missing a pressure gauge | |||
| GRAVITY SEWER TEST | 05/28/2026 | APPROVED | CVANSTRAHLEN |
| Note: Inspector Notes from Inspection 2060 FBC 3303.5-SWALE CLEAR 2/18/2026 - PREVIOUS INSPECTION NOTES Please fis items before next inspection #1-Please seperate Hot water and cold water in trench (clear path) min 6" for thermal transfer per Uponer manufacturer spec. 308.9 Parallel water distribution systems. Please sleeve all water supply lines that cross plumbing. FBCP 305.2 Stress and strain #2-FBCR P2503.5-NEEDS 5 FOOT HEAD TEST ON DWV ( not water on pipe , fill with water to top ) #3-Missing a pressure gauge | |||
| SEWER TIE IN | 05/28/2026 | Disapproved - NO FEE | CVANSTRAHLEN |
| Note: Please fix item before next inspection #1- Utilities like the City of Palm Coast Utility Department mandate that a cleanout be placed within 3 feet from the end of the PEP tank to provide a concrete reference point for elevation and maintenance. ( connection not visible ) Inspector Notes from Inspection 2060 FBC 3303.5-SWALE CLEAR 2/18/2026 - PREVIOUS INSPECTION NOTES Please fis items before next inspection #1-Please seperate Hot water and cold water in trench (clear path) min 6" for thermal transfer per Uponer manufacturer spec. 308.9 Parallel water distribution systems. Please sleeve all water supply lines that cross plumbing. FBCP 305.2 Stress and strain #2-FBCR P2503.5-NEEDS 5 FOOT HEAD TEST ON DWV ( not water on pipe , fill with water to top ) #3-Missing a pressure gauge | |||
| ELECTRIC - EARLY POWER | 05/27/2026 | APPROVED | CVANSTRAHLEN |
| Note: 5/15/2026 - PREVIOUS INSPECTION NOTES Please fix item before next inspection #1-NEC 250.24(A)(1) & 250.52(A)(3)-GROUNDING OF SERVICE - NEC-a ground rod or a complete grounding electrode system is required by the Florida Building Code and NEC Article 250 to obtain permanent or temporary power approval. For new construction, a concrete-encased electrode | |||
| ELECTRIC - EARLY POWER | 05/15/2026 | Disapproved - NO FEE | CVANSTRAHLEN |
| Note: Please fix item before next inspection #1-NEC 250.24(A)(1) & 250.52(A)(3)-GROUNDING OF SERVICE - NEC-a ground rod or a complete grounding electrode system is required by the Florida Building Code and NEC Article 250 to obtain permanent or temporary power approval. For new construction, a concrete-encased electrode | |||
| PEP TANK INSTALLATION REQUEST | 05/06/2026 | APPROVED | ISANDERSON |
| DRYWALL NAILING | 04/21/2026 | APPROVED | CVANSTRAHLEN |
| DRYWALL NAILING | 04/17/2026 | CANCELLED BY APPLICANT | WEB |
| LATH/BRICK/ WATER BARRIER | 04/17/2026 | APPROVED | CVANSTRAHLEN |
| INSULATION | 04/10/2026 | APPROVED | HCAMACHO |
| Note: New inspection due to canceled inspection 4/8/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1-Missing Fire rate foam where mark is with red sharpie market Items #1 #2 #3 from previous inspection not fix Item #1 can be inspected at final Inspector Notes from Inspection 2420 *** NOTES ADDED BY CVANSTRAHLEN 4/6/2026 2:21:49 PM *** please fix #2-FBCR P2605.1-PIPE SUPPORT PEX 32" HORIZONTAL 10 FOOT VERTICAL CPVC UP TO 1" - 3 FEET HORIZONTAL, 10 FEET VERTICAL CPVC 1 1/4" AND UP - 4 FEET HORIZONTAL, 10 FEET VERTICAL PVC 4 FOOT HORIZONTAL, 10 FEET VERTICAL #3-FBCR P2503.7-NEEDS WATER TEST ON DWV - 5 FT HEAD PRESSURE ABOVE HIGHEST FIXTURE - FILL TUB TO OVERFLOW Please fix items before next inspection #1-Missing Fl Approval number for windows and slidding door on Fl Approval sheet | |||
| INSULATION | 04/09/2026 | CANCELLED BY APPLICANT | WEB |
| Note: 4/8/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1-Missing Fire rate foam where mark is with red sharpie market Items #1 #2 #3 from previous inspection not fix Item #1 can be inspected at final Inspector Notes from Inspection 2420 *** NOTES ADDED BY CVANSTRAHLEN 4/6/2026 2:21:49 PM *** please fix #2-FBCR P2605.1-PIPE SUPPORT PEX 32" HORIZONTAL 10 FOOT VERTICAL CPVC UP TO 1" - 3 FEET HORIZONTAL, 10 FEET VERTICAL CPVC 1 1/4" AND UP - 4 FEET HORIZONTAL, 10 FEET VERTICAL PVC 4 FOOT HORIZONTAL, 10 FEET VERTICAL #3-FBCR P2503.7-NEEDS WATER TEST ON DWV - 5 FT HEAD PRESSURE ABOVE HIGHEST FIXTURE - FILL TUB TO OVERFLOW Please fix items before next inspection #1-Missing Fl Approval number for windows and slidding door on Fl Approval sheet | |||
| INSULATION | 04/08/2026 | Disapproved -FEE REQUIRED | CVANSTRAHLEN |
| Note: Please fix items before next inspection #1-Missing Fire rate foam where mark is with red sharpie market Items #1 #2 #3 from previous inspection not fix Item #1 can be inspected at final Inspector Notes from Inspection 2420 *** NOTES ADDED BY CVANSTRAHLEN 4/6/2026 2:21:49 PM *** please fix #2-FBCR P2605.1-PIPE SUPPORT PEX 32" HORIZONTAL 10 FOOT VERTICAL CPVC UP TO 1" - 3 FEET HORIZONTAL, 10 FEET VERTICAL CPVC 1 1/4" AND UP - 4 FEET HORIZONTAL, 10 FEET VERTICAL PVC 4 FOOT HORIZONTAL, 10 FEET VERTICAL #3-FBCR P2503.7-NEEDS WATER TEST ON DWV - 5 FT HEAD PRESSURE ABOVE HIGHEST FIXTURE - FILL TUB TO OVERFLOW Please fix items before next inspection #1-Missing Fl Approval number for windows and slidding door on Fl Approval sheet | |||
| ALL ROUGH | 04/06/2026 | APPROVED - AS NOTED | CVANSTRAHLEN |
| Note: *** NOTES ADDED BY CVANSTRAHLEN 4/6/2026 2:21:49 PM *** please fix #2-FBCR P2605.1-PIPE SUPPORT PEX 32" HORIZONTAL 10 FOOT VERTICAL CPVC UP TO 1" - 3 FEET HORIZONTAL, 10 FEET VERTICAL CPVC 1 1/4" AND UP - 4 FEET HORIZONTAL, 10 FEET VERTICAL PVC 4 FOOT HORIZONTAL, 10 FEET VERTICAL #3-FBCR P2503.7-NEEDS WATER TEST ON DWV - 5 FT HEAD PRESSURE ABOVE HIGHEST FIXTURE - FILL TUB TO OVERFLOW Please fix items before next inspection #1-Missing Fl Approval number for windows and slidding door on Fl Approval sheet | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 04/02/2026 | APPROVED | CVANSTRAHLEN |
| Note: 3/27/2026 - PREVIOUS INSPECTION NOTES 3/26/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection Item #1 and #2 need to be fix before next inspection . thank you 3/23/2026 - PREVIOUS INSPECTION NOTES cancelled by phone call 3/19/2026 - PREVIOUS INSPECTION NOTES 1. Part of the bearing wall in garage calls for 2x6 and 2x4 is installed including the post. Page S-5 marked 2. Bearing wall in garage is missing screws see note on page S-5. marked 3. Bearing wall in bedroom is missing screws and anchor bolts. see page S-5 and Detail B SD-3a. marked | |||
| WALL SHEATHING | 03/31/2026 | APPROVED | CVANSTRAHLEN |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/27/2026 | CANCELLED BY APPLICANT | CVANSTRAHLEN |
| Note: 3/26/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection Item #1 and #2 need to be fix before next inspection . thank you 3/23/2026 - PREVIOUS INSPECTION NOTES cancelled by phone call 3/19/2026 - PREVIOUS INSPECTION NOTES 1. Part of the bearing wall in garage calls for 2x6 and 2x4 is installed including the post. Page S-5 marked 2. Bearing wall in garage is missing screws see note on page S-5. marked 3. Bearing wall in bedroom is missing screws and anchor bolts. see page S-5 and Detail B SD-3a. marked | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/26/2026 | Disapproved -FEE REQUIRED | CVANSTRAHLEN |
| Note: Please fix items before next inspection Item #1 and #2 need to be fix before next inspection . thank you 3/23/2026 - PREVIOUS INSPECTION NOTES cancelled by phone call 3/19/2026 - PREVIOUS INSPECTION NOTES 1. Part of the bearing wall in garage calls for 2x6 and 2x4 is installed including the post. Page S-5 marked 2. Bearing wall in garage is missing screws see note on page S-5. marked 3. Bearing wall in bedroom is missing screws and anchor bolts. see page S-5 and Detail B SD-3a. marked | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/23/2026 | CANCELLED BY APPLICANT | CVANSTRAHLEN |
| Note: cancelled by phone call 3/19/2026 - PREVIOUS INSPECTION NOTES 1. Part of the bearing wall in garage calls for 2x6 and 2x4 is installed including the post. Page S-5 marked 2. Bearing wall in garage is missing screws see note on page S-5. marked 3. Bearing wall in bedroom is missing screws and anchor bolts. see page S-5 and Detail B SD-3a. marked | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/19/2026 | Disapproved - NO FEE | HCAMACHO |
| Note: 1. Part of the bearing wall in garage calls for 2x6 and 2x4 is installed including the post. Page S-5 marked 2. Bearing wall in garage is missing screws see note on page S-5. marked 3. Bearing wall in bedroom is missing screws and anchor bolts. see page S-5 and Detail B SD-3a. marked | |||
| ROOF VALLEY & METAL | 03/19/2026 | APPROVED | HCAMACHO |
| BLD - BUILDING FINAL | 03/19/2026 | CANCELLED BY APPLICANT | WEB |
| Note: Inspector Notes from Inspection 2465 *** NOTES ADDED BY RSIMS 3/17/2026 2:23:54 PM *** 3/17/26: Approved to dry in. Previously noted deficiency will still need to be resolved by Inspection 2460. Inspector Notes from Inspection 2340 Please fix item before next inspectionn #1-right side wall have 30' 1-1/2" is hanging out of slab , please have engineering fix , summit for revision and approval | |||
| ROOF SHEATHING | 03/17/2026 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 3/17/2026 2:23:54 PM *** 3/17/26: Approved to dry in. Previously noted deficiency will still need to be resolved by Inspection 2460. Inspector Notes from Inspection 2340 Please fix item before next inspectionn #1-right side wall have 30' 1-1/2" is hanging out of slab , please have engineering fix , summit for revision and approval | |||
| TIE BEAM / LINTEL | 03/09/2026 | APPROVED - AS NOTED | CVANSTRAHLEN |
| Note: Please fix item before next inspectionn #1-right side wall have 30' 1-1/2" is hanging out of slab , please have engineering fix , summit for revision and approval | |||
| MONOLITHIC SLAB | 02/27/2026 | APPROVED | BTAYLOR |
| Note: 2/25/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1-FBCR 318-MISSING UFER GROUND - CONCRETE ENCASED ELECTRODE ARE ( not tie to rebars ) #2-FBC R318.6.2 -REMOVE ALL VEGETATION , DEBRIS OF MATERIAL #3-FBCRP2603.4-SLEEVE PLUMBING OR PROVIDE A RELIEVING ARCH THROUGH FOUNDATION WALL ( BY MAIN DRAIN LINE BEHING GARAGE WALL BATHROOM , AND FOTTING BY LEAVING ROOM AREA ) | |||
| MONOLITHIC SLAB | 02/25/2026 | Disapproved - NO FEE | CVANSTRAHLEN |
| Note: Please fix items before next inspection #1-FBCR 318-MISSING UFER GROUND - CONCRETE ENCASED ELECTRODE ARE ( not tie to rebars ) #2-FBC R318.6.2 -REMOVE ALL VEGETATION , DEBRIS OF MATERIAL #3-FBCRP2603.4-SLEEVE PLUMBING OR PROVIDE A RELIEVING ARCH THROUGH FOUNDATION WALL ( BY MAIN DRAIN LINE BEHING GARAGE WALL BATHROOM , AND FOTTING BY LEAVING ROOM AREA ) | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 02/20/2026 | APPROVED - AS NOTED | CVANSTRAHLEN |
| Note: FBC 3303.5-SWALE CLEAR 2/18/2026 - PREVIOUS INSPECTION NOTES Please fis items before next inspection #1-Please seperate Hot water and cold water in trench (clear path) min 6" for thermal transfer per Uponer manufacturer spec. 308.9 Parallel water distribution systems. Please sleeve all water supply lines that cross plumbing. FBCP 305.2 Stress and strain #2-FBCR P2503.5-NEEDS 5 FOOT HEAD TEST ON DWV ( not water on pipe , fill with water to top ) #3-Missing a pressure gauge | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 02/18/2026 | Disapproved -FEE REQUIRED | CVANSTRAHLEN |
| Note: Please fis items before next inspection #1-Please seperate Hot water and cold water in trench (clear path) min 6" for thermal transfer per Uponer manufacturer spec. 308.9 Parallel water distribution systems. Please sleeve all water supply lines that cross plumbing. FBCP 305.2 Stress and strain #2-FBCR P2503.5-NEEDS 5 FOOT HEAD TEST ON DWV ( not water on pipe , fill with water to top ) #3-Missing a pressure gauge | |||
| FORMBOARD SURVEY (OFFICE USE ONLY) | 02/17/2026 | APPROVED | RRICKS |
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 02/10/2026 | APPROVED | PKNAPIK |
| WATER METER INSTALLATION REQUEST | 01/20/2026 | APPROVED | CBOWERMASTER |
| BLD - BUILDING FINAL | |||
| Note: New inspection due to canceled inspection Inspector Notes from Inspection 2465 *** NOTES ADDED BY RSIMS 3/17/2026 2:23:54 PM *** 3/17/26: Approved to dry in. Previously noted deficiency will still need to be resolved by Inspection 2460. Inspector Notes from Inspection 2340 Please fix item before next inspectionn #1-right side wall have 30' 1-1/2" is hanging out of slab , please have engineering fix , summit for revision and approval | |||
| ROW - FINAL APRON (AFTER POUR) | |||
| ROW - FINAL INSPECTION | |||
| U -UTILITY RESIDENTIAL FINAL | |||
| U-CROSS CONNECTION |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 03/13/2026 | 03/18/2026 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 02/17/2026 | 02/17/2026 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 02/17/2026 | 02/17/2026 |
| Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 02/10/2026 | 02/10/2026 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 01/29/2026 | 01/30/2026 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 12/26/2025 | 12/26/2025 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 12/26/2025 | 12/29/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| SW1 | CANCEL | 12/26/2025 | 12/31/2025 |
| SWALE | COMPLETE | 12/19/2025 | 01/06/2026 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 12/18/2025 | 12/26/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 12/18/2025 | 12/23/2025 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 12/18/2025 | 12/26/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 12/18/2025 | 12/19/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 12/18/2025 | 12/18/2025 |
| LOCATE | COMPLETE | 12/18/2025 | 12/23/2025 |
| Note: Released By: TONI CHURCHILL - - TCHURCHILL@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 12/18/2025 | 12/19/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 12/18/2025 | 12/22/2025 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | HOLD | 12/18/2025 | 12/18/2025 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM te site plan does not match any of the plans you have the wrong house on there |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| FC IMPACT FEE EMS | ¤62.00 | 01/08/2026 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 01/08/2026 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 01/08/2026 |
| FIRE RES IMPACT FEE 10-25 | ¤942.00 | 01/08/2026 |
| PEP TANK INSTALL | ¤756.74 | 01/08/2026 |
| PARKS IMPACT FEE 10-25 | ¤3,164.00 | 01/08/2026 |
| RSI DRIVEWAY AFTER POUR | ¤16.25 | 01/08/2026 |
| RSE DRIVE PRE POUR INSPECTION | ¤32.50 | 01/08/2026 |
| RSI FIELD SURVEY INSPECTION | ¤48.75 | 01/08/2026 |
| RSI FORMBOARD REVIEW | ¤16.25 | 01/08/2026 |
| RSI PLAN REVIEW NEW | ¤48.75 | 01/08/2026 |
| RSI FNL SURVEY/GRADING CERT | ¤48.75 | 01/08/2026 |
| RSI ROW FINAL INSPECTION | ¤16.25 | 01/08/2026 |
| SCHOOL BOARD IMPACT FEE RES | ¤5,450.00 | 01/08/2026 |
| WASTEWATER MAIN EXTENSION IMPA | ¤2,385.00 | 01/08/2026 |
| SURCHARGE FS 533.721 | ¤16.26 | 01/08/2026 |
| SURCHARGE - FS 468.631 | ¤24.38 | 01/08/2026 |
| SW ENG RES REVIEW 240 | ¤240.00 | 01/08/2026 |
| WATER METER W/ TAP | ¤2,326.93 | 01/08/2026 |
| TRANSP RES IMPACT FEE 10-25 | ¤8,791.64 | 01/08/2026 |
| SEWER CREDIT | (¤1,147.00) | 01/08/2026 |
| WASTEWATER PERM INSPECTION | ¤80.00 | 01/08/2026 |
| WASTEWATER PERM REVIEW | ¤25.00 | 01/08/2026 |
| SEWER CAPITAL FACILITY | ¤4,415.00 | 01/08/2026 |
| WATER CAPITAL FACILITY FEE | ¤3,790.49 | 01/08/2026 |
| WATER PERMIT REVIEW | ¤25.00 | 01/08/2026 |
| WATER MAIN EXTENSION IMPACT | ¤917.27 | 01/08/2026 |
| SITE PLAN 30 | ¤30.00 | 01/08/2026 |
| WATER- TURN ON | ¤50.00 | 01/08/2026 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 01/08/2026 |
| INSPECTION - RESIDENTIAL | ¤1,243.00 | 01/08/2026 |
| PLAN REVIEW - RESIDENTIAL | ¤352.56 | 01/08/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | |
| REINSPECTION RESIDENTIAL | ¤40.00 | |
| REINSPECTION RESIDENTIAL | ¤40.00 | |
| Fees | Total Due: ¤120.00 | Total Paid: ¤34,683.77 |