I want to search for...

Permit #2025120726

Permit Details

Status: COED

Parcel Id: 07-11-31-7058-00100-0240
CONDITIONED SPACE: 1333 sqft
GARAGE: 406 sqft
OPENED PORCH (WITH ROOF) : 222 sqft
Total Square Footage: 1961 sqft
Block: 00100
Subdivision: 2215 - SECTION 58-SEMINOLE PARK
Job Phone: 386-445-9009
Location Address: 19 SENSENEY PATH
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 12/31/2025
NOC: RECORDED
Applicant name: BRIAN ANDREW GAZZOLI
Owner: SEAGATE HOMES LLC

Address

185 CYPRESS POINT PARKWAY SUITE 7

PALM COAST, FL 32164

Lot: 0240
Contracted Stated Job Value: ¤253,158.00
Job Description: single family home
Type: CN

Contractor

SEAGATE HOMES, LLC
Status Location Address Mailing Address State License Number Phone
ACTIVE

185 CYPRESS POINT PARKWAY

Palm Coast, FL 32137

SUITE 7

Palm Coast, FL 32137

CGC1518372 (Exp: 08/31/2026) 386-246-6132

Sub Contractors

TIMUR ISPARYAN
Status Location Address State License Number Phone Fax
ACTIVE

3665 SPRINK PARK ROAD

JACKSONVILLE , FL 32207

CMC1249968 (Exp: 08/31/2026) 904-245-1818 904-337-1910
RICHARD H SIMMONS JR
Status Location Address State License Number Phone Fax
ACTIVE

PO BOX 1963

BUNNELL, FL 32110

ES12001217 (Exp: 08/31/2026) 386-437-0607 386-437-1847
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
CHAD DAVID GRESSANI
Status Location Address State License Number Phone Fax
ACTIVE

2640 BROOKSHIRE CIRCLE

MELBOURNE, FL 32904

CCC1327235 (Exp: 08/31/2026) 321-288-6415 321-729-8997

Inspection History

Type Request Date Result Inspector
ROW - FINAL INSPECTION 06/03/2026 APPROVED FSLADISH
Note: 6/3/26 CITY OF PALM COAST MINIMUM STANDARDS ARE MET AT THE TIME OF THIS INSPECTION. IT IS THE BUILDER'S AND/OR HOMEOWNER’S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. 6/1/2026 - PREVIOUS INSPECTION NOTES 6/1/26 YOU ARE REQUIRED TO CLEAN OUT CULVERT ENDS TO ENSURE DRAINAGE FLOW. YOR LEFT SIDE NEAR CULVERT MITERED END HAS WASHED IN SOME AND NEEDS TO BE CORRECTED. SEE PHOTO FOR REFERENCE. _____________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9463 5/27/26 THIS IS A DUPLICATE INSPECTION REQUEST. THIS LDAGC WAS APPROVED YESTERDAY 5/26/26. I AM APPROVING AS NOTED.
U -UTILITY RESIDENTIAL FINAL 06/01/2026 FINAL APPROVED BHAINES
U-CROSS CONNECTION 06/01/2026 APPROVED - AS NOTED BHAINES
Note: No CC
ROW - FINAL APRON (AFTER POUR) 06/01/2026 APPROVED FSLADISH
Note: 6/1/26 AT THE TIME OF THE INSPECTION ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. ______________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9463 5/27/26 THIS IS A DUPLICATE INSPECTION REQUEST. THIS LDAGC WAS APPROVED YESTERDAY 5/26/26. I AM APPROVING AS NOTED.
ROW - FINAL INSPECTION 06/01/2026 Disapproved -FEE REQUIRED FSLADISH
Note: 6/1/26 YOU ARE REQUIRED TO CLEAN OUT CULVERT ENDS TO ENSURE DRAINAGE FLOW. YOR LEFT SIDE NEAR CULVERT MITERED END HAS WASHED IN SOME AND NEEDS TO BE CORRECTED. SEE PHOTO FOR REFERENCE. _____________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9463 5/27/26 THIS IS A DUPLICATE INSPECTION REQUEST. THIS LDAGC WAS APPROVED YESTERDAY 5/26/26. I AM APPROVING AS NOTED.
BLD - BUILDING FINAL 06/01/2026 APPROVED CVANSTRAHLEN
ROW- FINAL SURVEY/GRADING CERTIFICATION 05/27/2026 APPROVED - AS NOTED FSLADISH
Note: 5/27/26 THIS IS A DUPLICATE INSPECTION REQUEST. THIS LDAGC WAS APPROVED YESTERDAY 5/26/26. I AM APPROVING AS NOTED.
ROW- FINAL SURVEY/GRADING CERTIFICATION 05/26/2026 APPROVED FSLADISH
Note: 5/26/26 BASED ON THE ENGINEER SIGNED AND SEALED LGADC MEETING THE COPC MINIMUM REQUIREMENTS AT THE TIME OF THIS INSPECTION, I AM APPROVING THIS DOCUMENT. Effective 3/25/26, the ROW Field Survey requirement is no longer in effect for Final Lot Grading and Drainage Certification for new construction on subdivision and infill lots. All Final Lot Grading and Drainage Certificates for these projects will now be reviewed and approved only in the office. Field verification for the ROW-FIELD SURVEY will no longer be required as part of the standard approval process for these permit types. 5/20/2026 - PREVIOUS INSPECTION NOTES 5/20/26 YOU ARE REQUIRED TO PROVIDE THE FFE ON THE IMPROVED LOT DIRECTLY BEHIND YOU. Finished Floor Elevations (FFE): Section 300.01 B(2) V-15 Finished Floor Elevations (FFE): 2) Finished Floor Elevation (FFE) of the living area of all improved structures on adjacent
ROW- FINAL SURVEY/GRADING CERTIFICATION 05/20/2026 Disapproved - NO FEE FSLADISH
Note: 5/20/26 YOU ARE REQUIRED TO PROVIDE THE FFE ON THE IMPROVED LOT DIRECTLY BEHIND YOU. Finished Floor Elevations (FFE): Section 300.01 B(2) V-15 Finished Floor Elevations (FFE): 2) Finished Floor Elevation (FFE) of the living area of all improved structures on adjacent
ROW- PRE-APRON (PRE-POUR) 04/20/2026 APPROVED PFLANAGAN
Note: IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection.
ELECTRIC - EARLY POWER 04/14/2026 APPROVED RMARTIN
DRYWALL NAILING 03/12/2026 APPROVED KSANDOE
INSULATION 03/09/2026 APPROVED CVANSTRAHLEN
Note: Inspector Notes from Inspection 2420 *** NOTES ADDED BY CVANSTRAHLEN 3/5/2026 9:31:48 AM *** Please fix #2-exhausted master bathroom missing support Flex duct connection #3-bathtub need fill water to top of over flow Please fix items before next inspection #1-FBCR P2605.1-PIPE SUPPORT PEX 32" HORIZONTAL 10 FOOT VERTICAL CPVC UP TO 1" - 3 FEET HORIZONTAL, 10 FEET VERTICAL CPVC 1 1/4" AND UP - 4 FEET HORIZONTAL, 10 FEET VERTICAL PVC 4 FOOT HORIZONTAL, 10 FEET VERTICAL ( laundry and master bathroom )
GRAVITY SEWER TEST 03/09/2026 APPROVED KSANDOE
SEWER TIE IN 03/09/2026 APPROVED KSANDOE
LATH/BRICK/ WATER BARRIER 03/06/2026 APPROVED - AS NOTED CVANSTRAHLEN
Note: Will check previous note on insulation inspection Inspector Notes from Inspection 2420 *** NOTES ADDED BY CVANSTRAHLEN 3/5/2026 9:31:48 AM *** Please fix #2-exhausted master bathroom missing support Flex duct connection #3-bathtub need fill water to top of over flow Please fix items before next inspection #1-FBCR P2605.1-PIPE SUPPORT PEX 32" HORIZONTAL 10 FOOT VERTICAL CPVC UP TO 1" - 3 FEET HORIZONTAL, 10 FEET VERTICAL CPVC 1 1/4" AND UP - 4 FEET HORIZONTAL, 10 FEET VERTICAL PVC 4 FOOT HORIZONTAL, 10 FEET VERTICAL ( laundry and master bathroom )
ALL ROUGH 03/05/2026 APPROVED - AS NOTED CVANSTRAHLEN
Note: *** NOTES ADDED BY CVANSTRAHLEN 3/5/2026 9:31:48 AM *** Please fix #2-exhausted master bathroom missing support Flex duct connection #3-bathtub need fill water to top of over flow Please fix items before next inspection #1-FBCR P2605.1-PIPE SUPPORT PEX 32" HORIZONTAL 10 FOOT VERTICAL CPVC UP TO 1" - 3 FEET HORIZONTAL, 10 FEET VERTICAL CPVC 1 1/4" AND UP - 4 FEET HORIZONTAL, 10 FEET VERTICAL PVC 4 FOOT HORIZONTAL, 10 FEET VERTICAL ( laundry and master bathroom )
ROOF VALLEY & METAL 02/26/2026 APPROVED KSANDOE
WALL SHEATHING 02/24/2026 APPROVED CVANSTRAHLEN
ROOF SHEATHING / BRACES/TIES/DOWN CELL 02/24/2026 APPROVED CVANSTRAHLEN
TIE BEAM / LINTEL 02/10/2026 APPROVED BTAYLOR
MONOLITHIC SLAB 01/30/2026 APPROVED BTAYLOR
PLUMBING 1ST ROUGH UNDERGROUND 01/28/2026 APPROVED BTAYLOR
FORMBOARD SURVEY (OFFICE USE ONLY) 01/27/2026 APPROVED RRICKS
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 01/20/2026 APPROVED PKNAPIK
WATER METER INSTALLATION REQUEST 01/08/2026 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
SW1 COMPLETE 01/27/2026 01/27/2026
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 01/27/2026 01/27/2026
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD COMPLETE 01/20/2026 01/20/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
SWALE COMPLETE 12/29/2025 01/15/2026
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
BLD COMPLETE 12/22/2025 12/30/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
CUSVC COMPLETE 12/22/2025 12/30/2025
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 12/22/2025 12/29/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 12/22/2025 12/29/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS CANCEL 12/22/2025 12/22/2025
LOCATE COMPLETE 12/22/2025 12/26/2025
Note: Released By: TONI CHURCHILL - - TCHURCHILL@PALMCOASTGOV.COM
MECH COMPLETE 12/22/2025 12/23/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 12/22/2025 12/30/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 12/22/2025 12/23/2025
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
RSI REINSPECTION 1 ¤35.00 06/03/2026
RSI ROW FINAL INSPECTION ¤16.25 12/31/2025
SCHOOL BOARD IMPACT FEE RES ¤5,450.00 12/31/2025
WASTEWATER MAIN EXTENSION IMPA ¤2,385.00 12/31/2025
SURCHARGE FS 533.721 ¤9.90 12/31/2025
SURCHARGE - FS 468.631 ¤14.85 12/31/2025
SW ENG RES REVIEW 240 ¤240.00 12/31/2025
WATER METER W/ TAP ¤2,326.93 12/31/2025
TRANSP RES IMPACT FEE 10-25 ¤5,025.41 12/31/2025
SEWER CREDIT (¤1,342.00) 12/31/2025
WASTEWATER PERM INSPECTION ¤80.00 12/31/2025
WASTEWATER PERM REVIEW ¤25.00 12/31/2025
SEWER CAPITAL FACILITY ¤4,415.00 12/31/2025
WATER CAPITAL FACILITY FEE ¤3,790.49 12/31/2025
WATER PERMIT REVIEW ¤25.00 12/31/2025
WATER MAIN EXTENSION IMPACT ¤917.27 12/31/2025
SITE PLAN 30 ¤30.00 12/31/2025
WATER- TURN ON ¤50.00 12/31/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 12/31/2025
INSPECTION - RESIDENTIAL ¤748.00 12/31/2025
PLAN REVIEW - RESIDENTIAL ¤212.16 12/31/2025
FC IMPACT FEE EMS ¤62.00 12/31/2025
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 12/31/2025
FC IMPACT FEE LIBRARY ¤268.00 12/31/2025
FIRE RES IMPACT FEE 10-25 ¤942.00 12/31/2025
PARKS IMPACT FEE 10-25 ¤3,164.00 12/31/2025
RSI DRIVEWAY AFTER POUR ¤16.25 12/31/2025
RSE DRIVE PRE POUR INSPECTION ¤32.50 12/31/2025
RSI FIELD SURVEY INSPECTION ¤48.75 12/31/2025
RSI FORMBOARD REVIEW ¤16.25 12/31/2025
RSI PLAN REVIEW NEW ¤48.75 12/31/2025
RSI FNL SURVEY/GRADING CERT ¤48.75 12/31/2025
Fees Total Due: ¤0.00 Total Paid: ¤29,349.51