I want to search for...
Permit #2025120772
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7023-00250-0110 |
| Block: 00250 |
| Subdivision: 7023 - |
| Job Phone: (386)627-0927 |
| Location Address: 22 WHITTLESEY LN |
| Type: PO - POOL |
| Issue Date: 01/08/2026 |
| NOC: RECORDED |
| Applicant name: JASON BRET PAVLOW |
| Owner: KEMMERLING RONALD L JR & DEE DEE H&W |
|
Address 22 WHITTLESEY LANE PALM COAST, FL 32164 |
| Lot: 0110 |
| Contracted Stated Job Value: ¤61,900.00 |
| Job Description: POOL |
| Type: CN |
Contractor
WATERSIDE POOLS INC
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| ACTIVE |
15 HARGROVE LANE PALM COAST , FL 32137 |
#3K PALM COAST , FL 32137 |
CPC1457358 (Exp: 08/31/2026) | (386)447-3390 | (386)447-3391 |
Sub Contractors
CHRISTOPHER I HALL
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
P. O. Box 2413 Bunnell, FL 32110 |
EC13002161 (Exp: 08/31/2028) | (386) 437-2966 | 386-437-5042 |
Inspection History
| Type | Request Date | Result | Inspector |
| POOL FINAL | 04/30/2026 | FINAL APPROVED | HCAMACHO |
| U -UTILITY RESIDENTIAL FINAL | 04/29/2026 | FINAL APPROVED | BHAINES |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 04/28/2026 | APPROVED | EMADISON |
| Note: | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 04/28/2026 | APPROVED | EMADISON |
| Note: ** SPOKE TO HOMEOWNER AT THE TIME OF THIS INSPECTION INDICATED NO ISSUES WITH DRAINAGE FROM PREVIOUS HEAVY RAINS ABOUT 2 WEEKS AGO ** AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW - FINAL INSPECTION | 04/28/2026 | APPROVED | EMADISON |
| Note: ** AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 04/27/2026 | Disapproved - NO FEE | TPOLACEK |
| Note: 04-27-26 11:51AM TPOLACEK*** RANG DOORBELL THERE WAS NO ANSWER. INSPECTOR NEEDS TO BE GRANTED PERMISSION TO ENTER THROUGH FENCE TO COMPLETE INSPECTION. 4/7/2026 - PREVIOUS INSPECTION NOTES 4/7/26 PLEASE READ PREVIOUS INSPECTION NOTES. YOU STILL ARE NOT SHOWING ENOUGH OF A SWALE IN THE REAR OF POOL. 3 TENTHS IS THE COPC MINIMUM STANDARD FOR SWALES. SEE PHOTO FOR REFERENCE. YOUR SITE PLAN SHOWS YOUR POOL DRAINGE FLOWING RIGHT AND LEFT TO THE FRONT SWALE FROM REAR MIDDLE OF REAR OF POOL. YOU ARE REQUIRED TO A MINIMUM 3 TENTHS SWALE IN THE DRAINAGE CONVEYANCE. SEE PHOTO FOR REFERENCE. ________________________________________________________________________________________________________________________________ SWALE 3 TENTHS TOE TO SLOPE Section 300.01 D(6) V-17 6) The top of slope of swales along the property lines and drainage conveyances shall be a minimum of 0.30 of a foot higher than the toe of slope. 3/20/2026 - PREVIOUS INSPECTION NOTES 3/20/26 YOUR SITE PLAN SHOWS YOUR POOL DRAINGE FLOWING RIGHT AND LEFT TO THE FRONT SWALE FROM REAR MIDDLE OF REAR OF POOL. YOU ARE REQUIRED TO A MINIMUM 3 TENTHS SWALE IN THE DRAINAGE CONVEYANCE. SEE PHOTO FOR REFERENCE. SWALE 3 TENTHS TOE TO SLOPE Section 300.01 D(6) V-17 6) The top of slope of swales along the property lines and drainage conveyances shall be a minimum of 0.30 of a foot higher than the toe of slope. | |||
| ROW- PROJECT STATUS | 04/10/2026 | Status Check | PFLANAGAN |
| Note: MET WITH CONTRACTOR ON WHAT NEEDED TO BE DONE TO PASS. HE WILL NEED TO HAVE MORE OF A SWALE FOR THE DRAINAGE BEHIND POOL MINIMUM OF .30. ------------------------------------------------------------------------ meeting a 11am | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 04/07/2026 | Disapproved - NO FEE | FSLADISH |
| Note: 4/7/26 PLEASE READ PREVIOUS INSPECTION NOTES. YOU STILL ARE NOT SHOWING ENOUGH OF A SWALE IN THE REAR OF POOL. 3 TENTHS IS THE COPC MINIMUM STANDARD FOR SWALES. SEE PHOTO FOR REFERENCE. YOUR SITE PLAN SHOWS YOUR POOL DRAINGE FLOWING RIGHT AND LEFT TO THE FRONT SWALE FROM REAR MIDDLE OF REAR OF POOL. YOU ARE REQUIRED TO A MINIMUM 3 TENTHS SWALE IN THE DRAINAGE CONVEYANCE. SEE PHOTO FOR REFERENCE. ________________________________________________________________________________________________________________________________ SWALE 3 TENTHS TOE TO SLOPE Section 300.01 D(6) V-17 6) The top of slope of swales along the property lines and drainage conveyances shall be a minimum of 0.30 of a foot higher than the toe of slope. 3/20/2026 - PREVIOUS INSPECTION NOTES 3/20/26 YOUR SITE PLAN SHOWS YOUR POOL DRAINGE FLOWING RIGHT AND LEFT TO THE FRONT SWALE FROM REAR MIDDLE OF REAR OF POOL. YOU ARE REQUIRED TO A MINIMUM 3 TENTHS SWALE IN THE DRAINAGE CONVEYANCE. SEE PHOTO FOR REFERENCE. SWALE 3 TENTHS TOE TO SLOPE Section 300.01 D(6) V-17 6) The top of slope of swales along the property lines and drainage conveyances shall be a minimum of 0.30 of a foot higher than the toe of slope. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 03/20/2026 | Disapproved - NO FEE | FSLADISH |
| Note: 3/20/26 YOUR SITE PLAN SHOWS YOUR POOL DRAINGE FLOWING RIGHT AND LEFT TO THE FRONT SWALE FROM REAR MIDDLE OF REAR OF POOL. YOU ARE REQUIRED TO A MINIMUM 3 TENTHS SWALE IN THE DRAINAGE CONVEYANCE. SEE PHOTO FOR REFERENCE. SWALE 3 TENTHS TOE TO SLOPE Section 300.01 D(6) V-17 6) The top of slope of swales along the property lines and drainage conveyances shall be a minimum of 0.30 of a foot higher than the toe of slope. | |||
| ELECTRIC AND ALARM | 03/10/2026 | APPROVED - AS NOTED | HCAMACHO |
| Note: 1. The gates on both sides need to be self closing. The gates are not closing on their own. FBC R4501.17 *Will look at Final* | |||
| POOL DECK | 02/17/2026 | APPROVED | MKRASKI |
| STEEL AND GROUND | 01/27/2026 | APPROVED | MKRASKI |
Review History
| Department | Status | Date In | Date Out |
| BFLOOD | CANCEL | 12/23/2025 | 12/30/2025 |
| BLD | COMPLETE | 12/23/2025 | 12/30/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 12/23/2025 | 12/30/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 12/23/2025 | 01/07/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| RSI | COMPLETE | 12/23/2025 | 12/26/2025 |
| Note: Released By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 12/23/2025 | 12/23/2025 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| RSI GENERAL INSPECTION 32.50 | ¤32.50 | 04/24/2026 |
| RSI PLAN REVIEW NEW | ¤48.75 | 01/08/2026 |
| RSI FNL SURVEY/GRADING CERT | ¤48.75 | 01/08/2026 |
| RSI ROW FINAL INSPECTION | ¤16.25 | 01/08/2026 |
| SURCHARGE FS 533.721 | ¤2.55 | 01/08/2026 |
| SURCHARGE - FS 468.631 | ¤3.83 | 01/08/2026 |
| SITE PLAN 30 | ¤30.00 | 01/08/2026 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 01/08/2026 |
| INSPECTION- POOL | ¤160.00 | 01/08/2026 |
| PLAN REVIEW - RESIDENTIAL | ¤65.00 | 01/08/2026 |
| RSI FIELD SURVEY INSPECTION | ¤48.75 | 01/08/2026 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤486.38 |