I want to search for...

Permit #2026010120

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7022-00080-0140
Block: 00080
Subdivision: 7022 -
Job Phone: 386-931-9006
Location Address: 265 WESTHAMPTON DR
Type: DR - DRIVEWAY
Issue Date: 01/26/2026
NOC: Unknown
Applicant name: JOSE CARLOS AZEVEDO
Owner: DICKOVER WILLIAM F & BARBARA J H&W LIFE ESTATE

Address

265 WESTHAMPTON DRIVE

PALM COAST, FL 32164

Lot: 0140
Contracted Stated Job Value: ¤2,300.00
Job Description: REMOVE AND REPLACE 17X13' CONCRETE DRIVEWAY
Type: CN

Contractor

S & D CONSTRUCTION AND MAINTENANCE
Status Location Address Phone
ACTIVE

37 PRICE LANE

PALM COAST, FL 32164

386-931-9006

Inspection History

Type Request Date Result Inspector
ROW - FINAL INSPECTION 02/12/2026 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED New inspection due to canceled inspection 2/10/2026 - PREVIOUS INSPECTION NOTES 02-10-26 TPOLACEK*** 5 Compacted dirt and sod must Drawing 300-G-12 Drawing 300-G-12 -Compacted dirt and sod must be placed around all edges of the poured concrete including around the miter ends and the driveway shoulders to prevent washout-ALL DISTURBED AREAS SHALL BE STABILIZED WITH SOD. Inspector Notes from Inspection 9270 01-27-26 TPOLACEK*** BUILDER NEED TO RAISE THE MITERED END FORM BOARD TO ACHIEVE A MINIMUM OF 2" OVEWR THE OPEN MITER CUT AS SHOWN IN DETAIL ATTACHED TO PERMIT IN PHOTOS. APPROVING AS NOTED. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. WOOD CONTROL JOINTS ARE PROHIBITED IN THE RIGHT-OF-WAY. SAWCUT SHALL BE PROVIDED AT THE EDGE OF ROW AND EVERY 12' THEREAFTER, OR A MINIMUM OF 2 SAWCUTS WHICHEVER IS GREATER"
ROW - FINAL INSPECTION 02/11/2026 CANCELLED BY APPLICANT WEB
Note: 2/10/2026 - PREVIOUS INSPECTION NOTES 02-10-26 TPOLACEK*** 5 Compacted dirt and sod must Drawing 300-G-12 Drawing 300-G-12 -Compacted dirt and sod must be placed around all edges of the poured concrete including around the miter ends and the driveway shoulders to prevent washout-ALL DISTURBED AREAS SHALL BE STABILIZED WITH SOD. Inspector Notes from Inspection 9270 01-27-26 TPOLACEK*** BUILDER NEED TO RAISE THE MITERED END FORM BOARD TO ACHIEVE A MINIMUM OF 2" OVEWR THE OPEN MITER CUT AS SHOWN IN DETAIL ATTACHED TO PERMIT IN PHOTOS. APPROVING AS NOTED. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. WOOD CONTROL JOINTS ARE PROHIBITED IN THE RIGHT-OF-WAY. SAWCUT SHALL BE PROVIDED AT THE EDGE OF ROW AND EVERY 12' THEREAFTER, OR A MINIMUM OF 2 SAWCUTS WHICHEVER IS GREATER"
ROW - FINAL APRON (AFTER POUR) 02/10/2026 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED 01-27-26 TPOLACEK*** BUILDER NEED TO RAISE THE MITERED END FORM BOARD TO ACHIEVE A MINIMUM OF 2" OVEWR THE OPEN MITER CUT AS SHOWN IN DETAIL ATTACHED TO PERMIT IN PHOTOS. APPROVING AS NOTED. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. WOOD CONTROL JOINTS ARE PROHIBITED IN THE RIGHT-OF-WAY. SAWCUT SHALL BE PROVIDED AT THE EDGE OF ROW AND EVERY 12' THEREAFTER, OR A MINIMUM OF 2 SAWCUTS WHICHEVER IS GREATER"
ROW - FINAL INSPECTION 02/10/2026 Disapproved -FEE REQUIRED TPOLACEK
Note: 02-10-26 TPOLACEK*** 5 Compacted dirt and sod must Drawing 300-G-12 Drawing 300-G-12 -Compacted dirt and sod must be placed around all edges of the poured concrete including around the miter ends and the driveway shoulders to prevent washout-ALL DISTURBED AREAS SHALL BE STABILIZED WITH SOD. Inspector Notes from Inspection 9270 01-27-26 TPOLACEK*** BUILDER NEED TO RAISE THE MITERED END FORM BOARD TO ACHIEVE A MINIMUM OF 2" OVEWR THE OPEN MITER CUT AS SHOWN IN DETAIL ATTACHED TO PERMIT IN PHOTOS. APPROVING AS NOTED. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. WOOD CONTROL JOINTS ARE PROHIBITED IN THE RIGHT-OF-WAY. SAWCUT SHALL BE PROVIDED AT THE EDGE OF ROW AND EVERY 12' THEREAFTER, OR A MINIMUM OF 2 SAWCUTS WHICHEVER IS GREATER"
U -UTILITY RESIDENTIAL FINAL 02/10/2026 FINAL APPROVED BHAINES
ROW- PRE-APRON (PRE-POUR) 01/27/2026 APPROVED - AS NOTED TPOLACEK
Note: 01-27-26 TPOLACEK*** BUILDER NEED TO RAISE THE MITERED END FORM BOARD TO ACHIEVE A MINIMUM OF 2" OVEWR THE OPEN MITER CUT AS SHOWN IN DETAIL ATTACHED TO PERMIT IN PHOTOS. APPROVING AS NOTED. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. WOOD CONTROL JOINTS ARE PROHIBITED IN THE RIGHT-OF-WAY. SAWCUT SHALL BE PROVIDED AT THE EDGE OF ROW AND EVERY 12' THEREAFTER, OR A MINIMUM OF 2 SAWCUTS WHICHEVER IS GREATER"

Review History

Department Status Date In Date Out
SWALE COMPLETE 01/08/2026 01/16/2026
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
ENGIN1 COMPLETE 01/07/2026 01/16/2026
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
RSI COMPLETE 01/07/2026 01/12/2026
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
UTL COMPLETE 01/07/2026 01/08/2026
Note: Released By: LARRY FITZGERALD - (386)286-2041 - LFITZGERALD@PALMCOASTGOV.COM
ZON COMPLETE 01/07/2026 01/07/2026
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Repairs in row only. No zoning review needed

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
RSI REINSPECTION 1 ¤35.00 02/10/2026
RSI ROW FINAL INSPECTION ¤16.25 01/26/2026
RSI SITE PLAN REVIEW ¤16.25 01/26/2026
SW ENG RES REVIEW 240 ¤240.00 01/26/2026
SITE PLAN 15 ¤15.00 01/26/2026
ADMINISTRATIVE RESIDENTIAL ¤30.00 01/26/2026
RSI DRIVEWAY AFTER POUR ¤16.25 01/26/2026
RSE DRIVE PRE POUR INSPECTION ¤32.50 01/26/2026
Fees Total Due: ¤0.00 Total Paid: ¤401.25