I want to search for...

Permit #2026010147

Permit Details

Status: INSPECT

Parcel Id: 42-10-30-3210-00000-2490
CONDITIONED SPACE: 2327 sqft
GARAGE: 621 sqft
OPENED PORCH (WITH ROOF) : 285 sqft
Total Square Footage: 3233 sqft
Block: 00000
Subdivision: 2094 - CONSERVATORY AT HAMMOCK BEACH
Job Phone: 386-236-4133
Location Address: 163 ASPEN WAY
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 01/22/2026
NOC: RECORDED
Applicant name: LEONARDO CIRO SANCLEMENTE
Owner: MHK OF VOLUSIA COUNTY INC

Address

2379 BEVILLE ROAD

DAYTONA BEACH, FL 32119

Lot: 2490
Contracted Stated Job Value: ¤323,316.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

VOLUSIA RESIDENTIAL CONSTRUCTION, LLC
Status Location Address State License Number Phone
ACTIVE

2379 BEVILLE RD

DAYTONA BEACH, FL 32119

CBC1262114 (Exp: 08/31/2026) 386-236-4133

Sub Contractors

JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
TIMUR ISPARYAN
Status Location Address State License Number Phone Fax
ACTIVE

3665 SPRINK PARK ROAD

JACKSONVILLE , FL 32207

CMC1249968 (Exp: 08/31/2026) 904-245-1818 904-337-1910
HUGH MACDONALD
Status Location Address State License Number Phone
ACTIVE

10825 TOM FOLSOM ROAD, SUITE A

THONOTOSASSA, FL 33592

CCC1329562 (Exp: 08/31/2026) 813-986-4968
HARLEY M BRYAN
Status Location Address State License Number Phone
ACTIVE

5223 EDGEWOOD CT

ORMOND BEACH, FL 32174

LI26657 (Exp: 08/31/2028) 386-463-2700
JAMES M GREENSLADE
Status Location Address State License Number Phone Fax
ACTIVE

311 S BAY ST

BUNNELL, FL 32110

EC13006083 (Exp: 08/31/2026) 386-263-2960 386-263-2980

Inspection History

Type Request Date Result Inspector
ROW- PRE-APRON (PRE-POUR) 06/04/2026 APPROVED - AS NOTED EMADISON
Note: 06/04/26 READY TO SET PAVERS ** ** AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED ________________________________________________________________________________________________________________________ 5/22/2026 - PREVIOUS INSPECTION NOTES ** 05/22/26 READY TO POUR APRON AND PAVER RESTRAINTS ** At the time of the inspection all minimum city requirements were met. It is the builder’s responsibility to ensure that nothing changes after this Inspection is approved. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE ** SCHEDULE NEXT PRE-POUR ONCE PAVER BASE HAS BEEN SPREAD AND COMPACTED ** DO NOT SET PAVERS UNTIL NEXT PRE-POUR HAS BEEN APPROVED ____________________________________________________________________________________________________________________
ELECTRIC - EARLY POWER 05/27/2026 APPROVED RMARTIN
Note: Inspector Notes from Inspection 2200 4/6/26 Emailed FPL
ROW- PAVER RESTRAINTS 05/22/2026 APPROVED - AS NOTED EMADISON
Note: ** 05/22/26 READY TO POUR PAVER RESTRAINTS WITH APRON ** At the time of the inspection all minimum city requirements were met. It is the builder’s responsibility to ensure that nothing changes after this Inspection is approved. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE ** SCHEDULE NEXT PRE-POUR ONCE PAVER BASE HAS BEEN SPREAD AND COMPACTED ** DO NOT SET PAVERS UNTIL NEXT PRE-POUR HAS BEEN APPROVED ____________________________________________________________________________________________________________________
ROW- PRE-APRON (PRE-POUR) 05/22/2026 PARTIALLY APPROVED EMADISON
Note: ** 05/22/26 READY TO POUR APRON AND PAVER RESTRAINTS ** At the time of the inspection all minimum city requirements were met. It is the builder’s responsibility to ensure that nothing changes after this Inspection is approved. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE ** SCHEDULE NEXT PRE-POUR ONCE PAVER BASE HAS BEEN SPREAD AND COMPACTED ** DO NOT SET PAVERS UNTIL NEXT PRE-POUR HAS BEEN APPROVED ____________________________________________________________________________________________________________________
DRYWALL NAILING 04/15/2026 APPROVED MCONTRYMAN
Note: 4/14/2026 - PREVIOUS INSPECTION NOTES Cancelled via text @ 8:38am
DRYWALL NAILING 04/14/2026 CANCELLED BY APPLICANT MCONTRYMAN
Note: Cancelled via text @ 8:38am
INSULATION 04/09/2026 APPROVED MCONTRYMAN
GAS ROUGH 04/09/2026 APPROVED MCONTRYMAN
Note: 4/8/2026 - PREVIOUS INSPECTION NOTES 4/8/26 1. Stub out for kitchen still showing no pressure in test. Spoke with contractor last time 4/6/2026 - PREVIOUS INSPECTION NOTES 4/6/26 1. Not all gas stub outs are hooked into main gas line. If the stub outs are to be seperate, each line will need to be tested seperately, be bonded, and have its own LP connection. FBCR G2417.4.1
GAS ROUGH 04/08/2026 Disapproved -FEE REQUIRED MCONTRYMAN
Note: 4/8/26 1. Stub out for kitchen still showing no pressure in test. Spoke with contractor last time 4/6/2026 - PREVIOUS INSPECTION NOTES 4/6/26 1. Not all gas stub outs are hooked into main gas line. If the stub outs are to be seperate, each line will need to be tested seperately, be bonded, and have its own LP connection. FBCR G2417.4.1
LATH/BRICK/ WATER BARRIER 04/08/2026 APPROVED MCONTRYMAN
Note: Inspector Notes from Inspection 2420 4/2/26 1. Nail plate needed for front master shower hot water line 2. Duct layout needs to be changed and approved to show installed layout 3. Meter/Main not installed at time of inspection (Greenslade on site) 4. SGD panels not installed at time of inspection
ELECTRIC-TUG 04/06/2026 APPROVED - AS NOTED MCONTRYMAN
Note: 4/6/26 Emailed FPL
GAS ROUGH 04/06/2026 Disapproved - NO FEE MCONTRYMAN
Note: 4/6/26 1. Not all gas stub outs are hooked into main gas line. If the stub outs are to be seperate, each line will need to be tested seperately, be bonded, and have its own LP connection. FBCR G2417.4.1
ALL ROUGH 04/02/2026 APPROVED - AS NOTED MCONTRYMAN
Note: 4/2/26 1. Nail plate needed for front master shower hot water line 2. Duct layout needs to be changed and approved to show installed layout 3. Meter/Main not installed at time of inspection (Greenslade on site) 4. SGD panels not installed at time of inspection
ROOF VALLEY & METAL 03/25/2026 APPROVED JSTEWART
WALL SHEATHING 03/20/2026 APPROVED MCONTRYMAN
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/20/2026 APPROVED - AS NOTED MCONTRYMAN
Note: 3/20/26 1. Truss B3, web W6, is bowed and needs repair 2. Missing SDWC screws per plan on page S1 (highlighted)
TIE BEAM / LINTEL 03/09/2026 APPROVED MCONTRYMAN
MONOLITHIC SLAB 02/26/2026 APPROVED KSANDOE
PLUMBING 1ST ROUGH UNDERGROUND 02/23/2026 APPROVED MCONTRYMAN
FORMBOARD SURVEY (OFFICE USE ONLY) 02/20/2026 APPROVED PFLANAGAN
GRAVITY SEWER TEST 02/18/2026 APPROVED MKRASKI
SEWER TIE IN 02/18/2026 APPROVED MKRASKI
WATER METER INSTALLATION REQUEST 02/18/2026 APPROVED ISANDERSON
U-CROSS CONNECTION
ROW - FINAL APRON (AFTER POUR)
ROW - FINAL INSPECTION
U -UTILITY RESIDENTIAL FINAL
BLD - BUILDING FINAL

Review History

Department Status Date In Date Out
MECH COMPLETE 04/02/2026 04/06/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
GAS COMPLETE 03/30/2026 03/31/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 02/20/2026 02/20/2026
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 02/20/2026 02/20/2026
Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM
ENGIN1 COMPLETE 01/15/2026 01/16/2026
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
ZON COMPLETE 01/15/2026 01/15/2026
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
ZON HOLD 01/14/2026 01/14/2026
Note: Held By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM site plan uploaded cannot have drainage info
ENGIN1 COMPLETE 01/14/2026 01/15/2026
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
SW1 COMPLETE 01/14/2026 01/15/2026
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
BLD COMPLETE 01/07/2026 01/09/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
CUSVC COMPLETE 01/07/2026 01/14/2026
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 01/07/2026 01/12/2026
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 01/07/2026 01/08/2026
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS COMPLETE 01/07/2026 01/08/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
LOCATE COMPLETE 01/07/2026 01/14/2026
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 01/07/2026 01/09/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 HOLD 01/07/2026 01/08/2026
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Grading comments: - There are slopes greater than 4:1 on the left side of this property. In 3 feet, the maximum fall allowed from grade adjacent to foundation to the lot line is .75'. - Along both lot lines there is are flat spots. There shall be 0.1' fall every 20', which is considered positive flow. - There shall be existing elevations shots on adjacent lots to clearly depict where the stormwater is going. - Based on the information provided this lot is negatively impacting lot 248. Please feel free to call or email if there are any questions or concerns,
ZON HOLD 01/07/2026 01/09/2026
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Map panel number should be 0038E change plan accordingly
URB COMPLETE 01/07/2026 01/12/2026
Note: Released By: MATTHEW SIERRA - (386)286-2002 - MSIERRA@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
FC IMPACT FEE EMS ¤62.00 01/22/2026
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 01/22/2026
FC IMPACT FEE LIBRARY ¤268.00 01/22/2026
FIRE RES IMPACT FEE 10-25 ¤942.00 01/22/2026
WATER METER W/OUT TAP ¤965.03 01/22/2026
PARKS IMPACT FEE 10-25 ¤3,164.00 01/22/2026
RSI DRIVEWAY AFTER POUR ¤16.25 01/22/2026
RSE DRIVE PRE POUR INSPECTION ¤32.50 01/22/2026
RSI FIELD SURVEY INSPECTION ¤48.75 01/22/2026
RSI FORMBOARD REVIEW ¤16.25 01/22/2026
RSI PLAN REVIEW NEW ¤48.75 01/22/2026
RSI FNL SURVEY/GRADING CERT ¤48.75 01/22/2026
RSI ROW FINAL INSPECTION ¤16.25 01/22/2026
SCHOOL BOARD IMPACT FEE RES ¤5,450.00 01/22/2026
SURCHARGE FS 533.721 ¤16.57 01/22/2026
SURCHARGE - FS 468.631 ¤24.86 01/22/2026
TRANSP RES IMPACT FEE 10-25 ¤8,772.79 01/22/2026
WASTEWATER PERM INSPECTION ¤80.00 01/22/2026
WASTEWATER PERM REVIEW ¤25.00 01/22/2026
WATER PERMIT REVIEW ¤25.00 01/22/2026
SITE PLAN 30 ¤30.00 01/22/2026
WATER- TURN ON ¤50.00 01/22/2026
ADMINISTRATIVE RESIDENTIAL ¤30.00 01/22/2026
INSPECTION - RESIDENTIAL ¤1,267.75 01/22/2026
PLAN REVIEW - RESIDENTIAL ¤359.58 01/22/2026
PLAN REVIEW - REVISION ¤32.50
PLAN REVIEW - REVISION ¤32.50
REINSPECTION RESIDENTIAL ¤40.00
CONTRACTOR CHANGE ¤20.00