I want to search for...
Permit #2026010193
Permit Details
Status: INSPECT
| Parcel Id: 03-12-31-1125-00000-0750 |
| CONDITIONED SPACE: 2113 sqft |
| GARAGE: 433 sqft |
| OPENED PORCH (WITH ROOF) : 76 sqft |
| OPENED PORCH (WITH ROOF) : 136 sqft |
| Total Square Footage: 2758 sqft |
| Subdivision: 2112 - COLBERT LANDINGS PH 1 |
| Job Phone: 813-917-1689 |
| Location Address: 15 GEOSAM DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 04/02/2026 |
| NOC: RECORDED |
| Applicant name: SCOTT EVAN KEUNING |
| Owner: TAYLOR MORRISON OF FLORIDA INC |
|
Address 1275 W GRANADA BLVD ORMOND BEACH, FL 32174 |
|
Address SUITE 3B ORMOND BEACH, FL 32174 |
| Lot: 75 |
| Contracted Stated Job Value: ¤216,244.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
TAYLOR MORRISON OF FLORIDA INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
7785 BAY MEADOWS WAY, SUITE 105 JACKSONVILLE, FL 32256 |
CBC1265083 (Exp: 08/31/2026) | 813-917-1689 |
Sub Contractors
JOSEPH H STRADA JR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3400 ST JOHNS PKWY SANFORD, FL 32771 |
CAC043953 (Exp: 08/31/2026) | 877-906-1113 |
JOSEPH HORATIO STRADA JR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3400 ST JOHNS PARKWAY SANFORD, FL 32771 |
EC13003715 (Exp: 08/31/2026) | 877-906-1113 |
BENJAMIN MICHAEL RAY
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| ACTIVE |
6310 MABLETON PKWY JACKSONVILLE, FL 32216 |
SUITE 1000 MABLETON, GA 30126 |
CFC1428415 (Exp: 08/31/2026) | 904-861-5421 | 904-861-5426 |
CHASE RANDOLPH MASSEY
| Status | Location Address | State License Number | Phone |
| ACTIVE |
10048 103RD ST JACKSONVILLE, FL 32210 |
CCC1332486 (Exp: 08/31/2026) | 904-248-1133 |
Inspection History
| Type | Request Date | Result | Inspector |
| LATH/BRICK/ WATER BARRIER | 06/11/2026 | CVANSTRAHLEN | |
| Note: Inspector Notes from Inspection 2420 Please fix items before next inspection #1-FBC [A] 105.7-NEEDS PERMIT ON SITE #2-FBC [A]107.3.1-NEEDS APPROVED PLANS ON SITE incluid E-cals #3-MIssing Fl Approval sheet #4-FBCR P2503.7-NEEDS WATER TEST ON DWV - 5 FT HEAD PRESSURE ABOVE HIGHEST FIXTURE - FILL TUB TO OVERFLOW #5-FBCR 609.1-GAP AT WINDOW/DOOR REVEAL TOO LARGE > 1/4 " PER MANUFACTURERS SPECS ( front door -top and slidding door top ) #6-SECURING & SUPPORTING -NEC 331.30 ( Electrical breaker panel securing and supporting required to be 12" fron edge of the panel Inspector Notes from Inspection 2467 items from previous inspection will check on next inspection Inspector Notes from Inspection 2460 Please fix items before next inspection n #1-Missing engineering on truss A4 #2- were required headers for windows missing 1/2" plywood #3-roof ginder back portch left wall , missing stud , plans call for qty 3 #4-missing bolt on garage floor plate right curve 5/19/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1-FBC [A] 105.7-NEEDS PERMIT ON SITE #2-FBC [A]107.3.1-NEEDS APPROVED PLANS ON SITE (INCLUDING TRUSS LAYOUT AND TRUSS PACKET) #3-FBCR 319.1-NEEDS ADDRESS POSTED #4-permit box empty #5-Roof sheathing was inspecting go to go ( Approved ) | |||
| ALL ROUGH | 06/03/2026 | APPROVED - AS NOTED | CVANSTRAHLEN |
| Note: Please fix items before next inspection #1-FBC [A] 105.7-NEEDS PERMIT ON SITE #2-FBC [A]107.3.1-NEEDS APPROVED PLANS ON SITE incluid E-cals #3-MIssing Fl Approval sheet #4-FBCR P2503.7-NEEDS WATER TEST ON DWV - 5 FT HEAD PRESSURE ABOVE HIGHEST FIXTURE - FILL TUB TO OVERFLOW #5-FBCR 609.1-GAP AT WINDOW/DOOR REVEAL TOO LARGE > 1/4 " PER MANUFACTURERS SPECS ( front door -top and slidding door top ) #6-SECURING & SUPPORTING -NEC 331.30 ( Electrical breaker panel securing and supporting required to be 12" fron edge of the panel Inspector Notes from Inspection 2467 items from previous inspection will check on next inspection Inspector Notes from Inspection 2460 Please fix items before next inspection n #1-Missing engineering on truss A4 #2- were required headers for windows missing 1/2" plywood #3-roof ginder back portch left wall , missing stud , plans call for qty 3 #4-missing bolt on garage floor plate right curve 5/19/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1-FBC [A] 105.7-NEEDS PERMIT ON SITE #2-FBC [A]107.3.1-NEEDS APPROVED PLANS ON SITE (INCLUDING TRUSS LAYOUT AND TRUSS PACKET) #3-FBCR 319.1-NEEDS ADDRESS POSTED #4-permit box empty #5-Roof sheathing was inspecting go to go ( Approved ) | |||
| ELECTRIC-TUG | 05/28/2026 | APPROVED | CVANSTRAHLEN |
| Note: 5/20/2026 - PREVIOUS INSPECTION NOTES FBC [A]107.4-NOT READY - WORK INCOMPLETE | |||
| ROOF VALLEY & METAL | 05/21/2026 | APPROVED - AS NOTED | CVANSTRAHLEN |
| Note: items from previous inspection will check on next inspection Inspector Notes from Inspection 2460 Please fix items before next inspection n #1-Missing engineering on truss A4 #2- were required headers for windows missing 1/2" plywood #3-roof ginder back portch left wall , missing stud , plans call for qty 3 #4-missing bolt on garage floor plate right curve 5/19/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1-FBC [A] 105.7-NEEDS PERMIT ON SITE #2-FBC [A]107.3.1-NEEDS APPROVED PLANS ON SITE (INCLUDING TRUSS LAYOUT AND TRUSS PACKET) #3-FBCR 319.1-NEEDS ADDRESS POSTED #4-permit box empty #5-Roof sheathing was inspecting go to go ( Approved ) | |||
| ELECTRIC-TUG | 05/20/2026 | Disapproved - NO FEE | CVANSTRAHLEN |
| Note: FBC [A]107.4-NOT READY - WORK INCOMPLETE | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/20/2026 | APPROVED - AS NOTED | CVANSTRAHLEN |
| Note: Please fix items before next inspection n #1-Missing engineering on truss A4 #2- were required headers for windows missing 1/2" plywood #3-roof ginder back portch left wall , missing stud , plans call for qty 3 #4-missing bolt on garage floor plate right curve 5/19/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1-FBC [A] 105.7-NEEDS PERMIT ON SITE #2-FBC [A]107.3.1-NEEDS APPROVED PLANS ON SITE (INCLUDING TRUSS LAYOUT AND TRUSS PACKET) #3-FBCR 319.1-NEEDS ADDRESS POSTED #4-permit box empty #5-Roof sheathing was inspecting go to go ( Approved ) | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/19/2026 | Disapproved - NO FEE | CVANSTRAHLEN |
| Note: Please fix items before next inspection #1-FBC [A] 105.7-NEEDS PERMIT ON SITE #2-FBC [A]107.3.1-NEEDS APPROVED PLANS ON SITE (INCLUDING TRUSS LAYOUT AND TRUSS PACKET) #3-FBCR 319.1-NEEDS ADDRESS POSTED #4-permit box empty | |||
| WALL SHEATHING | 05/18/2026 | APPROVED | CVANSTRAHLEN |
| Note: 5/14/2026 - PREVIOUS INSPECTION NOTES Please removed the nails that are not heating the studs , left wallgarage ( from previous inspection ) 5/13/2026 - PREVIOUS INSPECTION NOTES 5/13/26 1. Left side garage wall has too many fasteners that missed the studs. Needs to be knocked out and make sure all studs were hit correctly | |||
| WALL SHEATHING | 05/14/2026 | Disapproved -FEE REQUIRED | CVANSTRAHLEN |
| Note: Please removed the nails that are not heating the studs , left wallgarage ( from previous inspection ) 5/13/2026 - PREVIOUS INSPECTION NOTES 5/13/26 1. Left side garage wall has too many fasteners that missed the studs. Needs to be knocked out and make sure all studs were hit correctly | |||
| WALL SHEATHING | 05/13/2026 | Disapproved - NO FEE | MCONTRYMAN |
| Note: 5/13/26 1. Left side garage wall has too many fasteners that missed the studs. Needs to be knocked out and make sure all studs were hit correctly | |||
| MONOLITHIC SLAB | 04/27/2026 | APPROVED | CVANSTRAHLEN |
| PLUMBING 1ST ROUGH UNDERGROUND | 04/24/2026 | APPROVED | CVANSTRAHLEN |
| WATER METER INSTALLATION REQUEST | 04/24/2026 | APPROVED | ISANDERSON |
| FORMBOARD SURVEY (OFFICE USE ONLY) | 04/23/2026 | APPROVED | PFLANAGAN |
| GRAVITY SEWER TEST | |||
| SEWER TIE IN | |||
| ELECTRIC - EARLY POWER | |||
| INSULATION | |||
| DRYWALL NAILING | |||
| BLD - BUILDING FINAL | |||
| U-CROSS CONNECTION | |||
| ROW- PRE-APRON (PRE-POUR) | |||
| ROW - FINAL APRON (AFTER POUR) | |||
| ROW - FINAL INSPECTION | |||
| U -UTILITY RESIDENTIAL FINAL |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 04/22/2026 | 04/23/2026 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 04/22/2026 | 04/22/2026 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 03/30/2026 | 03/30/2026 |
| Note: Released By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 03/19/2026 | 03/25/2026 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | HOLD | 03/09/2026 | 03/09/2026 |
| Note: Held By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM ***REPEAT COMMENT*** 7 gallon screening required. Looks like you just change the screening plantings SUBMIT UPDATED LANDSCAPE PLAN | |||
| MECH | COMPLETE | 03/09/2026 | 03/10/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 03/09/2026 | 03/11/2026 |
| Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Lot lines along improved lots shall not be changed no more than 0.1' This ensure that as built grades and drainage is not negatively impacted. Please make revisions as needed. Please feel free to call or email if there are any questions or concerns. | |||
| ZON | HOLD | 02/13/2026 | 02/13/2026 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM 7 gallon screening required. Looks like you just change the screening plantings | |||
| MECH | HOLD | 02/12/2026 | 02/17/2026 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide updated state card | |||
| ELEC | COMPLETE | 02/12/2026 | 02/18/2026 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 02/12/2026 | 02/17/2026 |
| Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Please provide the 10' shots on adjacent lot to clearly depict whether this lot or adjacent lots are negatively impacted. Note: COPC has agreed to allow approved final survey for existing elevations. Please revise this proposed grading plan incorporating the existing elevation 10' beyond property line. Please feel free to call 386-986-4726 or email if there are any questions or concerns. | |||
| BLD | COMPLETE | 01/08/2026 | 01/13/2026 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 01/08/2026 | 01/14/2026 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 01/08/2026 | 01/13/2026 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. DW outlet can not be located behind the DW. NEC 2020 422.16 2. Dryer needs to be GFCI protected. NEC 2020 210.8 3. Need correct outlet spacing on kitchen island. NEC 2020 210.52 (B) | |||
| ENGIN1 | COMPLETE | 01/08/2026 | 01/09/2026 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 01/08/2026 | 01/12/2026 |
| LOCATE | COMPLETE | 01/08/2026 | 01/14/2026 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | HOLD | 01/08/2026 | 01/12/2026 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Design location on Energy Calcs and heatload need to be Daytona Beach. Provide updated state card when resubmitting | |||
| SW1 | HOLD | 01/08/2026 | 01/14/2026 |
| Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Please provide existing road centerline, edge of pavement elevations on 20' grid, this shall also include existing elevations 10' beyond the lot lines. Approved as-built eleavations are accpeptable. Please feel free to call or email if there are any questions or concerns. | |||
| ZON | COMPLETE | 01/08/2026 | 01/12/2026 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| URB | COMPLETE | 01/08/2026 | 01/14/2026 |
| Note: Released By: JOHN BEAUDET - (386)986-2456 - JBEAUDET@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| FC IMPACT FEE EMS | ¤62.00 | 04/02/2026 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 04/02/2026 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 04/02/2026 |
| FIRE RES IMPACT FEE 10-25 | ¤942.00 | 04/02/2026 |
| WATER METER W/OUT TAP | ¤965.03 | 04/02/2026 |
| PARKS IMPACT FEE 10-25 | ¤3,164.00 | 04/02/2026 |
| RSI DRIVEWAY AFTER POUR | ¤16.25 | 04/02/2026 |
| RSE DRIVE PRE POUR INSPECTION | ¤32.50 | 04/02/2026 |
| RSI FIELD SURVEY INSPECTION | ¤48.75 | 04/02/2026 |
| RSI FORMBOARD REVIEW | ¤16.25 | 04/02/2026 |
| RSI PLAN REVIEW NEW | ¤48.75 | 04/02/2026 |
| RSI FNL SURVEY/GRADING CERT | ¤48.75 | 04/02/2026 |
| RSI ROW FINAL INSPECTION | ¤16.25 | 04/02/2026 |
| SURCHARGE FS 533.721 | ¤14.63 | 04/02/2026 |
| SURCHARGE - FS 468.631 | ¤21.95 | 04/02/2026 |
| SW ENG RES REVIEW 240 | ¤240.00 | 04/02/2026 |
| TRANSP RES IMPACT FEE 10-25 | ¤7,966.01 | 04/02/2026 |
| WASTEWATER PERM INSPECTION | ¤80.00 | 04/02/2026 |
| WASTEWATER PERM REVIEW | ¤25.00 | 04/02/2026 |
| SEWER CAPITAL FACILITY | ¤3,613.92 | 04/02/2026 |
| WATER CAPITAL FACILITY FEE | ¤3,039.48 | 04/02/2026 |
| WATER PERMIT INSPECTION | ¤40.00 | 04/02/2026 |
| WATER PERMIT REVIEW | ¤25.00 | 04/02/2026 |
| SITE PLAN 30 | ¤30.00 | 04/02/2026 |
| WATER-METER | ¤965.03 | 04/02/2026 |
| WATER- TURN ON | ¤50.00 | 04/02/2026 |
| WATER- TURN ON | ¤50.00 | 04/02/2026 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 04/02/2026 |
| INSPECTION - RESIDENTIAL | ¤1,116.50 | 04/02/2026 |
| PLAN REVIEW - RESIDENTIAL | ¤316.68 | 04/02/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | |
| Fees | Total Due: ¤40.00 | Total Paid: ¤23,470.73 |