Permit #2026010194

Permit Details

Status: INSPECT

Parcel Id: 03-12-31-1125-00000-0730
CONDITIONED SPACE: 1764 sqft
GARAGE: 424 sqft
OPENED PORCH (WITH ROOF) : 235 sqft
OPENED PORCH (WITH ROOF) : 259 sqft
Total Square Footage: 2682 sqft
Subdivision: 2112 - COLBERT LANDINGS PH 1
Job Phone: 813-917-1689
Location Address: 19 GEOSAM DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 03/25/2026
NOC: RECORDED
Applicant name: SCOTT EVAN KEUNING
Owner: TAYLOR MORRISON OF FLORIDA INC

Address

1275 W GRANADA BLVD

ORMOND BEACH, FL 32174

Address

SUITE 3B

ORMOND BEACH, FL 32174

Lot: 73
Contracted Stated Job Value: ¤151,575.00
Job Description: SINGLE FAMILY
Type: CN

Contractor

TAYLOR MORRISON OF FLORIDA INC
Status Location Address State License Number Phone
ACTIVE

7785 BAY MEADOWS WAY, SUITE 105

JACKSONVILLE, FL 32256

CBC1265083 (Exp: 08/31/2026) 813-917-1689

Sub Contractors

JOSEPH H STRADA JR
Status Location Address State License Number Phone
ACTIVE

3400 ST JOHNS PKWY

SANFORD, FL 32771

CAC043953 (Exp: 08/31/2026) 877-906-1113
JOSEPH HORATIO STRADA JR
Status Location Address State License Number Phone
ACTIVE

3400 ST JOHNS PARKWAY

SANFORD, FL 32771

EC13003715 (Exp: 08/31/2026) 877-906-1113
BENJAMIN MICHAEL RAY
Status Location Address Mailing Address State License Number Phone Fax
ACTIVE

6310 MABLETON PKWY

JACKSONVILLE, FL 32216

SUITE 1000

MABLETON, GA 30126

CFC1428415 (Exp: 08/31/2026) 904-861-5421 904-861-5426
CHASE RANDOLPH MASSEY
Status Location Address State License Number Phone
ACTIVE

10048 103RD ST

JACKSONVILLE, FL 32210

CCC1332486 (Exp: 08/31/2026) 904-248-1133

Inspection History

Type Request Date Result Inspector
LATH/BRICK/ WATER BARRIER 06/11/2026 CVANSTRAHLEN
Note: Inspector Notes from Inspection 2420 *** NOTES ADDED BY CVANSTRAHLEN 6/8/2026 9:37:34 AM *** #4--FBCR P2503.7-NEEDS WATER TEST ON DWV - 5 FT HEAD PRESSURE ABOVE HIGHEST FIXTURE - FILL TUB TO OVERFLOW Please fix items before next inspection #1-Required Fire blocking on areas mark on page S-4 , areas mark with green sharpie highlighter( master bedroom entrance right side , front door entrance left and right side , hallway entrance left and right side #2-FBCR 609.1-GAP AT WINDOW/DOOR REVEAL TOO LARGE > 1/4 " PER MANUFACTURERS SPECS ( front door -top , slidding door top and right side , windows next to slidding door top , mark with green flourescent highligter on page S-4 #3-NEC 300.4-NEEDS NAIL GUARDS pantry closet left side door top king stub Inspector Notes from Inspection 2467 Items from previous inspection will be check on next inspection Inspector Notes from Inspection 2460 Please fix items before next inspection #1-MIssing engineering on truss A21 #2-Garage header requred 3 Kings on each side #3-Missing 6x6 column on back portch 5/19/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1-FBC [A] 105.7-NEEDS PERMIT ON SITE #2-FBC [A]107.3.1-NEEDS APPROVED PLANS ON SITE (INCLUDING TRUSS LAYOUT AND TRUSS PACKET) #3-FBCR 319.1-NEEDS ADDRESS POSTED #4-permit box empty #5-Roof sheathing was inspecting go to go ( approved )
ALL ROUGH 06/08/2026 APPROVED - AS NOTED CVANSTRAHLEN
Note: *** NOTES ADDED BY CVANSTRAHLEN 6/8/2026 9:37:34 AM *** #4--FBCR P2503.7-NEEDS WATER TEST ON DWV - 5 FT HEAD PRESSURE ABOVE HIGHEST FIXTURE - FILL TUB TO OVERFLOW Please fix items before next inspection #1-Required Fire blocking on areas mark on page S-4 , areas mark with green sharpie highlighter( master bedroom entrance right side , front door entrance left and right side , hallway entrance left and right side #2-FBCR 609.1-GAP AT WINDOW/DOOR REVEAL TOO LARGE > 1/4 " PER MANUFACTURERS SPECS ( front door -top , slidding door top and right side , windows next to slidding door top , mark with green flourescent highligter on page S-4 #3-NEC 300.4-NEEDS NAIL GUARDS pantry closet left side door top king stub Inspector Notes from Inspection 2467 Items from previous inspection will be check on next inspection Inspector Notes from Inspection 2460 Please fix items before next inspection #1-MIssing engineering on truss A21 #2-Garage header requred 3 Kings on each side #3-Missing 6x6 column on back portch 5/19/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1-FBC [A] 105.7-NEEDS PERMIT ON SITE #2-FBC [A]107.3.1-NEEDS APPROVED PLANS ON SITE (INCLUDING TRUSS LAYOUT AND TRUSS PACKET) #3-FBCR 319.1-NEEDS ADDRESS POSTED #4-permit box empty #5-Roof sheathing was inspecting go to go ( approved )
ROOF VALLEY & METAL 05/21/2026 APPROVED - AS NOTED CVANSTRAHLEN
Note: Items from previous inspection will be check on next inspection Inspector Notes from Inspection 2460 Please fix items before next inspection #1-MIssing engineering on truss A21 #2-Garage header requred 3 Kings on each side #3-Missing 6x6 column on back portch 5/19/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1-FBC [A] 105.7-NEEDS PERMIT ON SITE #2-FBC [A]107.3.1-NEEDS APPROVED PLANS ON SITE (INCLUDING TRUSS LAYOUT AND TRUSS PACKET) #3-FBCR 319.1-NEEDS ADDRESS POSTED #4-permit box empty #5-Roof sheathing was inspecting go to go ( approved )
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/20/2026 APPROVED - AS NOTED CVANSTRAHLEN
Note: Please fix items before next inspection #1-MIssing engineering on truss A21 #2-Garage header requred 3 Kings on each side #3-Missing 6x6 column on back portch 5/19/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1-FBC [A] 105.7-NEEDS PERMIT ON SITE #2-FBC [A]107.3.1-NEEDS APPROVED PLANS ON SITE (INCLUDING TRUSS LAYOUT AND TRUSS PACKET) #3-FBCR 319.1-NEEDS ADDRESS POSTED #4-permit box empty #5-Roof sheathing was inspecting go to go ( approved )
ELECTRIC-TUG 05/20/2026 APPROVED - AS NOTED CVANSTRAHLEN
Note: Please fix item before next inspection #1-Electric tug outlet required to be fastened and secure
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/19/2026 Disapproved - NO FEE CVANSTRAHLEN
Note: Please fix items before next inspection #1-FBC [A] 105.7-NEEDS PERMIT ON SITE #2-FBC [A]107.3.1-NEEDS APPROVED PLANS ON SITE (INCLUDING TRUSS LAYOUT AND TRUSS PACKET) #3-FBCR 319.1-NEEDS ADDRESS POSTED #4-permit box empty
WALL SHEATHING 05/13/2026 APPROVED MCONTRYMAN
MONOLITHIC SLAB 04/28/2026 APPROVED CVANSTRAHLEN
Note: 4/27/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1-FBC-A.107.4-Footers not per plans #2-FBC R506.1 -SLAB MINIMUM THICKNESS 3 1/2 #3-Rebars need to be 3" clearance front soil per FL building code requirements #4-FBCRP2603-SLEEVE PLUMBING OR PROVIDE A RELIEVING ARCH THROUGH FOUNDATION WALL #5-Removed 6 Mill vapor barrier on ufer ground bar 6'
MONOLITHIC SLAB 04/27/2026 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: Please fix items before next inspection #1-FBC-A.107.4-Footers not per plans #2-FBC R506.1 -SLAB MINIMUM THICKNESS 3 1/2 #3-Rebars need to be 3" clearance front soil per FL building code requirements #4-FBCRP2603-SLEEVE PLUMBING OR PROVIDE A RELIEVING ARCH THROUGH FOUNDATION WALL #5-Removed 6 Mill vapor barrier on ufer ground bar 6'
WATER METER INSTALLATION REQUEST 04/24/2026 APPROVED ISANDERSON
PLUMBING 1ST ROUGH UNDERGROUND 04/23/2026 APPROVED CVANSTRAHLEN
FORMBOARD SURVEY (OFFICE USE ONLY) 04/22/2026 APPROVED RRICKS
GRAVITY SEWER TEST
SEWER TIE IN
ELECTRIC - EARLY POWER
INSULATION
DRYWALL NAILING
BLD - BUILDING FINAL
U-CROSS CONNECTION
ROW- PRE-APRON (PRE-POUR)
ROW - FINAL APRON (AFTER POUR)
ROW - FINAL INSPECTION
U -UTILITY RESIDENTIAL FINAL

Review History

Department Status Date In Date Out
SW1 COMPLETE 04/22/2026 04/22/2026
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 04/22/2026 04/22/2026
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
ZON COMPLETE 02/23/2026 02/23/2026
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
ZON HOLD 02/12/2026 02/12/2026
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Your still provide two different sq footage for the lot
SW1 COMPLETE 02/12/2026 02/17/2026
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ENGIN1 COMPLETE 02/12/2026 02/12/2026
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
BLD COMPLETE 01/08/2026 01/13/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
CUSVC COMPLETE 01/08/2026 01/14/2026
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 01/08/2026 01/13/2026
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 01/08/2026 01/09/2026
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS CANCEL 01/08/2026 01/12/2026
LOCATE COMPLETE 01/08/2026 01/14/2026
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 01/08/2026 01/12/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 HOLD 01/08/2026 01/14/2026
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM - Please provide 10' shots on adjacent lots on 20' grid. Approved as-built elevations are acceptable. - Grading plan does not match approved master plan along the side lot lines. - There is a proposed elevation in the back yard that does not agree with B-type drainage.
ZON HOLD 01/08/2026 01/09/2026
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Plat shows the lot square footage as 8176.67 site plan states 8225.
URB COMPLETE 01/08/2026 01/14/2026
Note: Released By: JOHN BEAUDET - (386)986-2456 - JBEAUDET@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
FC IMPACT FEE EMS ¤62.00 03/25/2026
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 03/25/2026
FC IMPACT FEE LIBRARY ¤268.00 03/25/2026
FIRE RES IMPACT FEE 10-25 ¤942.00 03/25/2026
WATER METER W/OUT TAP ¤965.03 03/25/2026
PARKS IMPACT FEE 10-25 ¤3,164.00 03/25/2026
RSI DRIVEWAY AFTER POUR ¤16.25 03/25/2026
RSE DRIVE PRE POUR INSPECTION ¤32.50 03/25/2026
RSI FIELD SURVEY INSPECTION ¤48.75 03/25/2026
RSI FORMBOARD REVIEW ¤16.25 03/25/2026
RSI PLAN REVIEW NEW ¤48.75 03/25/2026
RSI FNL SURVEY/GRADING CERT ¤48.75 03/25/2026
RSI ROW FINAL INSPECTION ¤16.25 03/25/2026
SURCHARGE FS 533.721 ¤13.22 03/25/2026
SURCHARGE - FS 468.631 ¤19.83 03/25/2026
TRANSP RES IMPACT FEE 10-25 ¤6,650.28 03/25/2026
WASTEWATER PERM INSPECTION ¤80.00 03/25/2026
WASTEWATER PERM REVIEW ¤25.00 03/25/2026
SEWER CAPITAL FACILITY ¤3,613.92 03/25/2026
WATER CAPITAL FACILITY FEE ¤3,039.48 03/25/2026
WATER PERMIT INSPECTION ¤40.00 03/25/2026
WATER PERMIT REVIEW ¤25.00 03/25/2026
SITE PLAN 30 ¤30.00 03/25/2026
WATER-METER ¤965.03 03/25/2026
WATER- TURN ON ¤50.00 03/25/2026
WATER- TURN ON ¤50.00 03/25/2026
ADMINISTRATIVE RESIDENTIAL ¤30.00 03/25/2026
INSPECTION - RESIDENTIAL ¤1,006.50 03/25/2026
PLAN REVIEW - RESIDENTIAL ¤285.48 03/25/2026
REINSPECTION RESIDENTIAL ¤40.00