I want to search for...
Permit #2026010194
Permit Details
Status: INSPECT
| Parcel Id: 03-12-31-1125-00000-0730 |
| CONDITIONED SPACE: 1764 sqft |
| GARAGE: 424 sqft |
| OPENED PORCH (WITH ROOF) : 235 sqft |
| OPENED PORCH (WITH ROOF) : 259 sqft |
| Total Square Footage: 2682 sqft |
| Subdivision: 2112 - COLBERT LANDINGS PH 1 |
| Job Phone: 813-917-1689 |
| Location Address: 19 GEOSAM DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 03/25/2026 |
| NOC: RECORDED |
| Applicant name: SCOTT EVAN KEUNING |
| Owner: TAYLOR MORRISON OF FLORIDA INC |
|
Address 1275 W GRANADA BLVD ORMOND BEACH, FL 32174 |
|
Address SUITE 3B ORMOND BEACH, FL 32174 |
| Lot: 73 |
| Contracted Stated Job Value: ¤151,575.00 |
| Job Description: SINGLE FAMILY |
| Type: CN |
Contractor
TAYLOR MORRISON OF FLORIDA INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
7785 BAY MEADOWS WAY, SUITE 105 JACKSONVILLE, FL 32256 |
CBC1265083 (Exp: 08/31/2026) | 813-917-1689 |
Sub Contractors
JOSEPH H STRADA JR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3400 ST JOHNS PKWY SANFORD, FL 32771 |
CAC043953 (Exp: 08/31/2026) | 877-906-1113 |
JOSEPH HORATIO STRADA JR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3400 ST JOHNS PARKWAY SANFORD, FL 32771 |
EC13003715 (Exp: 08/31/2026) | 877-906-1113 |
BENJAMIN MICHAEL RAY
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| ACTIVE |
6310 MABLETON PKWY JACKSONVILLE, FL 32216 |
SUITE 1000 MABLETON, GA 30126 |
CFC1428415 (Exp: 08/31/2026) | 904-861-5421 | 904-861-5426 |
CHASE RANDOLPH MASSEY
| Status | Location Address | State License Number | Phone |
| ACTIVE |
10048 103RD ST JACKSONVILLE, FL 32210 |
CCC1332486 (Exp: 08/31/2026) | 904-248-1133 |
Inspection History
| Type | Request Date | Result | Inspector |
| LATH/BRICK/ WATER BARRIER | 06/11/2026 | CVANSTRAHLEN | |
| Note: Inspector Notes from Inspection 2420 *** NOTES ADDED BY CVANSTRAHLEN 6/8/2026 9:37:34 AM *** #4--FBCR P2503.7-NEEDS WATER TEST ON DWV - 5 FT HEAD PRESSURE ABOVE HIGHEST FIXTURE - FILL TUB TO OVERFLOW Please fix items before next inspection #1-Required Fire blocking on areas mark on page S-4 , areas mark with green sharpie highlighter( master bedroom entrance right side , front door entrance left and right side , hallway entrance left and right side #2-FBCR 609.1-GAP AT WINDOW/DOOR REVEAL TOO LARGE > 1/4 " PER MANUFACTURERS SPECS ( front door -top , slidding door top and right side , windows next to slidding door top , mark with green flourescent highligter on page S-4 #3-NEC 300.4-NEEDS NAIL GUARDS pantry closet left side door top king stub Inspector Notes from Inspection 2467 Items from previous inspection will be check on next inspection Inspector Notes from Inspection 2460 Please fix items before next inspection #1-MIssing engineering on truss A21 #2-Garage header requred 3 Kings on each side #3-Missing 6x6 column on back portch 5/19/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1-FBC [A] 105.7-NEEDS PERMIT ON SITE #2-FBC [A]107.3.1-NEEDS APPROVED PLANS ON SITE (INCLUDING TRUSS LAYOUT AND TRUSS PACKET) #3-FBCR 319.1-NEEDS ADDRESS POSTED #4-permit box empty #5-Roof sheathing was inspecting go to go ( approved ) | |||
| ALL ROUGH | 06/08/2026 | APPROVED - AS NOTED | CVANSTRAHLEN |
| Note: *** NOTES ADDED BY CVANSTRAHLEN 6/8/2026 9:37:34 AM *** #4--FBCR P2503.7-NEEDS WATER TEST ON DWV - 5 FT HEAD PRESSURE ABOVE HIGHEST FIXTURE - FILL TUB TO OVERFLOW Please fix items before next inspection #1-Required Fire blocking on areas mark on page S-4 , areas mark with green sharpie highlighter( master bedroom entrance right side , front door entrance left and right side , hallway entrance left and right side #2-FBCR 609.1-GAP AT WINDOW/DOOR REVEAL TOO LARGE > 1/4 " PER MANUFACTURERS SPECS ( front door -top , slidding door top and right side , windows next to slidding door top , mark with green flourescent highligter on page S-4 #3-NEC 300.4-NEEDS NAIL GUARDS pantry closet left side door top king stub Inspector Notes from Inspection 2467 Items from previous inspection will be check on next inspection Inspector Notes from Inspection 2460 Please fix items before next inspection #1-MIssing engineering on truss A21 #2-Garage header requred 3 Kings on each side #3-Missing 6x6 column on back portch 5/19/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1-FBC [A] 105.7-NEEDS PERMIT ON SITE #2-FBC [A]107.3.1-NEEDS APPROVED PLANS ON SITE (INCLUDING TRUSS LAYOUT AND TRUSS PACKET) #3-FBCR 319.1-NEEDS ADDRESS POSTED #4-permit box empty #5-Roof sheathing was inspecting go to go ( approved ) | |||
| ROOF VALLEY & METAL | 05/21/2026 | APPROVED - AS NOTED | CVANSTRAHLEN |
| Note: Items from previous inspection will be check on next inspection Inspector Notes from Inspection 2460 Please fix items before next inspection #1-MIssing engineering on truss A21 #2-Garage header requred 3 Kings on each side #3-Missing 6x6 column on back portch 5/19/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1-FBC [A] 105.7-NEEDS PERMIT ON SITE #2-FBC [A]107.3.1-NEEDS APPROVED PLANS ON SITE (INCLUDING TRUSS LAYOUT AND TRUSS PACKET) #3-FBCR 319.1-NEEDS ADDRESS POSTED #4-permit box empty #5-Roof sheathing was inspecting go to go ( approved ) | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/20/2026 | APPROVED - AS NOTED | CVANSTRAHLEN |
| Note: Please fix items before next inspection #1-MIssing engineering on truss A21 #2-Garage header requred 3 Kings on each side #3-Missing 6x6 column on back portch 5/19/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1-FBC [A] 105.7-NEEDS PERMIT ON SITE #2-FBC [A]107.3.1-NEEDS APPROVED PLANS ON SITE (INCLUDING TRUSS LAYOUT AND TRUSS PACKET) #3-FBCR 319.1-NEEDS ADDRESS POSTED #4-permit box empty #5-Roof sheathing was inspecting go to go ( approved ) | |||
| ELECTRIC-TUG | 05/20/2026 | APPROVED - AS NOTED | CVANSTRAHLEN |
| Note: Please fix item before next inspection #1-Electric tug outlet required to be fastened and secure | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/19/2026 | Disapproved - NO FEE | CVANSTRAHLEN |
| Note: Please fix items before next inspection #1-FBC [A] 105.7-NEEDS PERMIT ON SITE #2-FBC [A]107.3.1-NEEDS APPROVED PLANS ON SITE (INCLUDING TRUSS LAYOUT AND TRUSS PACKET) #3-FBCR 319.1-NEEDS ADDRESS POSTED #4-permit box empty | |||
| WALL SHEATHING | 05/13/2026 | APPROVED | MCONTRYMAN |
| MONOLITHIC SLAB | 04/28/2026 | APPROVED | CVANSTRAHLEN |
| Note: 4/27/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1-FBC-A.107.4-Footers not per plans #2-FBC R506.1 -SLAB MINIMUM THICKNESS 3 1/2 #3-Rebars need to be 3" clearance front soil per FL building code requirements #4-FBCRP2603-SLEEVE PLUMBING OR PROVIDE A RELIEVING ARCH THROUGH FOUNDATION WALL #5-Removed 6 Mill vapor barrier on ufer ground bar 6' | |||
| MONOLITHIC SLAB | 04/27/2026 | Disapproved -FEE REQUIRED | CVANSTRAHLEN |
| Note: Please fix items before next inspection #1-FBC-A.107.4-Footers not per plans #2-FBC R506.1 -SLAB MINIMUM THICKNESS 3 1/2 #3-Rebars need to be 3" clearance front soil per FL building code requirements #4-FBCRP2603-SLEEVE PLUMBING OR PROVIDE A RELIEVING ARCH THROUGH FOUNDATION WALL #5-Removed 6 Mill vapor barrier on ufer ground bar 6' | |||
| WATER METER INSTALLATION REQUEST | 04/24/2026 | APPROVED | ISANDERSON |
| PLUMBING 1ST ROUGH UNDERGROUND | 04/23/2026 | APPROVED | CVANSTRAHLEN |
| FORMBOARD SURVEY (OFFICE USE ONLY) | 04/22/2026 | APPROVED | RRICKS |
| GRAVITY SEWER TEST | |||
| SEWER TIE IN | |||
| ELECTRIC - EARLY POWER | |||
| INSULATION | |||
| DRYWALL NAILING | |||
| BLD - BUILDING FINAL | |||
| U-CROSS CONNECTION | |||
| ROW- PRE-APRON (PRE-POUR) | |||
| ROW - FINAL APRON (AFTER POUR) | |||
| ROW - FINAL INSPECTION | |||
| U -UTILITY RESIDENTIAL FINAL |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 04/22/2026 | 04/22/2026 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 04/22/2026 | 04/22/2026 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 02/23/2026 | 02/23/2026 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| ZON | HOLD | 02/12/2026 | 02/12/2026 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Your still provide two different sq footage for the lot | |||
| SW1 | COMPLETE | 02/12/2026 | 02/17/2026 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 02/12/2026 | 02/12/2026 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 01/08/2026 | 01/13/2026 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 01/08/2026 | 01/14/2026 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 01/08/2026 | 01/13/2026 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 01/08/2026 | 01/09/2026 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 01/08/2026 | 01/12/2026 |
| LOCATE | COMPLETE | 01/08/2026 | 01/14/2026 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 01/08/2026 | 01/12/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 01/08/2026 | 01/14/2026 |
| Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM - Please provide 10' shots on adjacent lots on 20' grid. Approved as-built elevations are acceptable. - Grading plan does not match approved master plan along the side lot lines. - There is a proposed elevation in the back yard that does not agree with B-type drainage. | |||
| ZON | HOLD | 01/08/2026 | 01/09/2026 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Plat shows the lot square footage as 8176.67 site plan states 8225. | |||
| URB | COMPLETE | 01/08/2026 | 01/14/2026 |
| Note: Released By: JOHN BEAUDET - (386)986-2456 - JBEAUDET@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| FC IMPACT FEE EMS | ¤62.00 | 03/25/2026 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 03/25/2026 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 03/25/2026 |
| FIRE RES IMPACT FEE 10-25 | ¤942.00 | 03/25/2026 |
| WATER METER W/OUT TAP | ¤965.03 | 03/25/2026 |
| PARKS IMPACT FEE 10-25 | ¤3,164.00 | 03/25/2026 |
| RSI DRIVEWAY AFTER POUR | ¤16.25 | 03/25/2026 |
| RSE DRIVE PRE POUR INSPECTION | ¤32.50 | 03/25/2026 |
| RSI FIELD SURVEY INSPECTION | ¤48.75 | 03/25/2026 |
| RSI FORMBOARD REVIEW | ¤16.25 | 03/25/2026 |
| RSI PLAN REVIEW NEW | ¤48.75 | 03/25/2026 |
| RSI FNL SURVEY/GRADING CERT | ¤48.75 | 03/25/2026 |
| RSI ROW FINAL INSPECTION | ¤16.25 | 03/25/2026 |
| SURCHARGE FS 533.721 | ¤13.22 | 03/25/2026 |
| SURCHARGE - FS 468.631 | ¤19.83 | 03/25/2026 |
| TRANSP RES IMPACT FEE 10-25 | ¤6,650.28 | 03/25/2026 |
| WASTEWATER PERM INSPECTION | ¤80.00 | 03/25/2026 |
| WASTEWATER PERM REVIEW | ¤25.00 | 03/25/2026 |
| SEWER CAPITAL FACILITY | ¤3,613.92 | 03/25/2026 |
| WATER CAPITAL FACILITY FEE | ¤3,039.48 | 03/25/2026 |
| WATER PERMIT INSPECTION | ¤40.00 | 03/25/2026 |
| WATER PERMIT REVIEW | ¤25.00 | 03/25/2026 |
| SITE PLAN 30 | ¤30.00 | 03/25/2026 |
| WATER-METER | ¤965.03 | 03/25/2026 |
| WATER- TURN ON | ¤50.00 | 03/25/2026 |
| WATER- TURN ON | ¤50.00 | 03/25/2026 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 03/25/2026 |
| INSPECTION - RESIDENTIAL | ¤1,006.50 | 03/25/2026 |
| PLAN REVIEW - RESIDENTIAL | ¤285.48 | 03/25/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | |
| Fees | Total Due: ¤40.00 | Total Paid: ¤21,770.27 |