Permit #2026010330
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7025-00410-0020 |
| Block: 00410 |
| Subdivision: 7025 - |
| Job Phone: 386-325-5095 |
| Location Address: 19 PARKVIEW DR |
| Type: ME - MECHANICAL |
| Issue Date: 01/20/2026 |
| NOC: RECORDED |
| Applicant name: JOHN ANTHONY BUCCA |
| Owner: COTHRAN CHARLENE ELIZABETH |
|
Address 19 PARKVIEW DRIVE PALM COAST, FL 32164 |
| Lot: 0020 |
| Contracted Stated Job Value: ¤18,000.00 |
| Job Description: Replace 3.5 Ton Split System, like for like |
| Type: CN |
Contractor
ARTIC AIR CONDITIONING & HOME SERVICES, LLC
| Status | Location Address | State License Number | Phone |
| INACTIVE |
342 S HWY 17 EAST PATLATKA, FL 32131 |
CAC1822567 (Exp: 08/31/2026) | 386-325-5095 |
Inspection History
| Type | Request Date | Result | Inspector |
| HVAC FINAL | 01/23/2026 | FINAL APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 1/23/2026 1:04:00 PM *** 1/21/2026 - PREVIOUS INSPECTION NOTES 1/21/26: A Virtual inspection will be available IF requested at the time of scheduling the re-inspection. If requesting a Virtual Re-inspection, please schedule the re-inspection for the same day that the deficiencies will be corrected and a FaceTime or Google Meet live virtual inspection can be completed. (Pictures are not approved). ------------------------------->>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> 1). Supply and Return ducts need to be sealed where they enter the ceiling. 2). hole in garage ceiling for lineset needs to be sealed with approved (fire rated) material FBC-R302.11(4). 3). Soffit where lineset enters needs to be sealed around linset as required. FBC-R806.1 4). Newly installed plywood behind AHU unit in garage needs to be covered or replaced with a fire retardent material to meet the garage separation requirements. FBC-R302.6 | |||
| HVAC FINAL | 01/21/2026 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 1/21/2026 12:53:22 PM *** 1/21/26: A Virtual inspection will be available IF requested at the time of scheduling the re-inspection. If requesting a Virtual Re-inspection, please schedule the re-inspection for the same day that the deficiencies will be corrected and a FaceTime or Google Meet live virtual inspection can be completed. (Pictures are not approved). ------------------------------->>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> 1). Supply and Return ducts need to be sealed where they enter the ceiling. 2). hole in garage ceiling for lineset needs to be sealed with approved (fire rated) material FBC-R302.11(4). 3). Soffit where lineset enters needs to be sealed around linset as required. FBC-R806.1 4). Newly installed plywood behind AHU unit in garage needs to be covered or replaced with a fire retardent material to meet the garage separation requirements. FBC-R302.6 |
Review History
| Department | Status | Date In | Date Out |
| BADMIN | COMPLETE | 01/14/2026 | 01/14/2026 |
| Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM | |||
| BADMIN | HOLD | 01/14/2026 | 01/14/2026 |
| Note: Held By: JAZMIN ROSARIO - - JROSARIO@PALMCOASTGOV.COM SUBMIT SIGNED & NOTARIZED LIEN LAW AFFIDAVIT AND RECORDED NOC | |||
| BADMIN | COMPLETE | 01/14/2026 | 01/14/2026 |
| Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM | |||
| BADMIN | HOLD | 01/13/2026 | 01/13/2026 |
| Note: Held By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM SUBMIT SIGNED & NOTARIZED LIEN LAW AFFIDAVIT |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 01/22/2026 |
| SURCHARGE FS 533.721 | ¤2.00 | 01/20/2026 |
| SURCHARGE - FS 468.631 | ¤2.00 | 01/20/2026 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 01/20/2026 |
| INSPECTION - MECHANICAL | ¤60.00 | 01/20/2026 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤134.00 |