I want to search for...
Permit #2026010422
Permit Details
Status: INSPECT
| Parcel Id: 01-12-30-5550-00030-0030 |
| OPENED PORCH (WITH ROOF) : 705 sqft |
| Total Square Footage: 705 sqft |
| Block: 00030 |
| Subdivision: - |
| Job Phone: 386-237-5837 |
| Location Address: 4 ETNA WAY |
| Type: BA - BUILDING ADDITION |
| Issue Date: 02/04/2026 |
| NOC: RECORDED |
| Applicant name: MARSEL GILMANSHIN |
| Owner: LEONID LEVIT AND ELLA CHAGEYEVA |
|
Address 47 EDITH POPE DRIVE PALM COAST, FL 32164 |
| Lot: 0030 |
| Contracted Stated Job Value: ¤20,000.00 |
| Job Description: house addition |
| Type: CN |
Contractor
GILMANS DEVELOPMENT CORP
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4873 PALM COAST PARKWAY NW #4 PALM COAST, FL 32137 |
CBC1263180 (Exp: 08/31/2026) | 386-237-5837 |
Sub Contractors
WILLIAM TODD SIKES
| Status | Location Address | State License Number | Phone |
| ACTIVE |
83 PORT ROYAL DR ST AUGUSTINE, FL 32084 |
EC0002726 (Exp: 08/31/2026) | 904-762-8762 |
Inspection History
| Type | Request Date | Result | Inspector |
| ALL ROUGH | 05/20/2026 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 5/20/2026 3:58:18 PM *** Approved | |||
| LATH/BRICK/ WATER BARRIER | 05/12/2026 | APPROVED | HCAMACHO |
| ROOF VALLEY & METAL | 05/01/2026 | APPROVED | HCAMACHO |
| Note: Inspector Notes from Inspection 2460 4/28/26 4. The Wood Lam does not have any attachments to the block wall on both ends. Plans call for (2) Heta 20's at each end --If not completed by next inspection, failure and fee will occur 4/14/2026 - PREVIOUS INSPECTION NOTES 1. Need to remove wood from inspection holes on the block to verify concrete on the down cell. 2. Please take a look at the roof framing detail and valley framing detail on the plans. Allot of the hardware is missing on the rafters, ridge beam and collar ties. 3. The hardware used on the rafters to the Wood Lam is the wrong kind. It calls for MTS20 & using H2.5. 4. The Wood Lam does not have any attachments to the block wall on both ends. Inspector Notes from Inspection 2340 *** NOTES ADDED BY RSIMS 3/2/2026 9:40:12 AM *** 3/2/26: 1). Electrical feed conduit at the back wall will need to be located inside the wall or otherwise protected from damage. NEC 300.4 | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 04/28/2026 | APPROVED - AS NOTED | MCONTRYMAN |
| Note: 4/28/26 4. The Wood Lam does not have any attachments to the block wall on both ends. Plans call for (2) Heta 20's at each end --If not completed by next inspection, failure and fee will occur 4/14/2026 - PREVIOUS INSPECTION NOTES 1. Need to remove wood from inspection holes on the block to verify concrete on the down cell. 2. Please take a look at the roof framing detail and valley framing detail on the plans. Allot of the hardware is missing on the rafters, ridge beam and collar ties. 3. The hardware used on the rafters to the Wood Lam is the wrong kind. It calls for MTS20 & using H2.5. 4. The Wood Lam does not have any attachments to the block wall on both ends. Inspector Notes from Inspection 2340 *** NOTES ADDED BY RSIMS 3/2/2026 9:40:12 AM *** 3/2/26: 1). Electrical feed conduit at the back wall will need to be located inside the wall or otherwise protected from damage. NEC 300.4 | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 04/14/2026 | Disapproved - NO FEE | HCAMACHO |
| Note: 1. Need to remove wood from inspection holes on the block to verify concrete on the down cell. 2. Please take a look at the roof framing detail and valley framing detail on the plans. Allot of the hardware is missing on the rafters, ridge beam and collar ties. 3. The hardware used on the rafters to the Wood Lam is the wrong kind. It calls for MTS20 & using H2.5. 4. The Wood Lam does not have any attachments to the block wall on both ends. Inspector Notes from Inspection 2340 *** NOTES ADDED BY RSIMS 3/2/2026 9:40:12 AM *** 3/2/26: 1). Electrical feed conduit at the back wall will need to be located inside the wall or otherwise protected from damage. NEC 300.4 | |||
| TIE BEAM / LINTEL | 03/02/2026 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 3/2/2026 9:40:12 AM *** 3/2/26: 1). Electrical feed conduit at the back wall will need to be located inside the wall or otherwise protected from damage. NEC 300.4 | |||
| MONOLITHIC SLAB | 02/09/2026 | APPROVED | BTAYLOR |
| BLD - BUILDING FINAL | |||
| ROW - FINAL INSPECTION | |||
| U -UTILITY RESIDENTIAL FINAL |
Review History
| Department | Status | Date In | Date Out |
| PLENV | COMPLETE | 01/29/2026 | 02/03/2026 |
| Note: Released By: DYLAN RODRIGUEZ - (386)986-2320 - DRODRIGUEZ@PALMCOASTGOV.COM no comment. Gopher Tortoises on site were previously relocated and no new active burrows have been found. | |||
| ZON | COMPLETE | 01/29/2026 | 01/30/2026 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| RSI | COMPLETE | 01/29/2026 | 02/03/2026 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM NO NEED FOR FINAL SURVEY DUE TO SCREEN IS ON POOL DECK NO NEW ADDITION | |||
| ENGIN1 | COMPLETE | 01/29/2026 | 02/03/2026 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | HOLD | 01/16/2026 | 01/20/2026 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM repeat comment: No dimension provided. the proposed covered patio on the site plan and a provide the dimensions and the all the setbacks from the proposed addtion to property lines | |||
| BLD | COMPLETE | 01/15/2026 | 01/21/2026 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| ENGIN1 | HOLD | 01/15/2026 | 01/23/2026 |
| Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM The site plan must show where the new building addition and the sqft of the new addition. | |||
| RSI | HOLD | 01/15/2026 | 01/22/2026 |
| Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM The site plan must show where the new building addition and the sqft of the new addition. | |||
| ZON | HOLD | 01/15/2026 | 01/15/2026 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM add the proposed covered patio on the site plan and a provide the dimensions and the all the setbacks from the proposed addtion to property lines | |||
| PLENV | HOLD | 01/15/2026 | 01/16/2026 |
| Note: Held By: DYLAN RODRIGUEZ - (386)986-2320 - DRODRIGUEZ@PALMCOASTGOV.COM 1.0 The site plan provided shows potential Gopher Tortoise burrows with potential impacts from construction. Please provide an approved After-action report after relocation has been completed. 2.0It also appears the Gopher Tortoise survey has surpassed the 90 day period they are accepted for FWC. Please provide a updated Gopher Tortoise survey. | |||
| ELEC | COMPLETE | 01/15/2026 | 01/21/2026 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 02/04/2026 |
| INSPECTION - RESIDENTIAL | ¤137.50 | 02/04/2026 |
| PLAN REVIEW - RESIDENTIAL | ¤65.00 | 02/04/2026 |
| RSI PLAN REVIEW NEW | ¤48.75 | 02/04/2026 |
| RSI ROW FINAL INSPECTION | ¤16.25 | 02/04/2026 |
| SURCHARGE FS 533.721 | ¤2.33 | 02/04/2026 |
| SURCHARGE - FS 468.631 | ¤3.49 | 02/04/2026 |
| SITE PLAN 30 | ¤30.00 | 02/04/2026 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤333.32 |